HomeMy WebLinkAboutBrentwood (5152023)BRENTWOOD
LITTLE ROCK, ARKANSAS
5/15/23 5/15/23BRENTWOOD
GENERAL SITE NOTES:
1.
2.
3.
4.
GENERAL CONTRACTOR TO VERIFY THE EXISTING TOPOGRAPHIC
GRADE LEVELS, LOCATIONS OF TREES, AND THE PROPOSED
BUILDING LOCATIONS. CONTRACTOR TO NOTIFY DESIGNER OF
SITE CONDITIONS PRIOR TO START OF CONSTRUCTION.
GENERAL CONTRACTOR TO HAVE A LICENSED ENGINEER OR
LICENSED SURVEYOR STAKE OUT OR VERIFY THE BUILDING
LOCATION TO ENSURE THAT THE BUILDING DOES NOT ENCROACH
ON ANY SETBACKS OR EASEMENTS, UNLESS THE
ENCROACHMENT IS ALLOWED BY ZONING AND BUILDING CODES.
CONTRACTOR TO NOTIFY DESIGNER IF ANY ENCROACHMENT
ISSUES PRIOR TO START OF CONSTRUCTION.
GENERAL CONTRACTOR TO LOCATE ALL UTILITY SERVICES, I.E.
WATER, SEWER, GAS, ELECTRICAL, TELEPHONE, CABLE TV, AND
COORDINATE THE EXTENSIONS TO THE BUILDING WITH THE
APPROPRIATE INSTALLER.
GENERAL CONTRACTOR TO COORDINATE FINISH TOPOGRAPHIC
GRADING AND PAVING OF WALKS, DRIVEWAYS, PATIOS, ETC. AS
REQUIRED FOR POSITIVE DRAINAGE AWAY FROM THE BUILDING.
GENERAL CONSTRUCTION NOTES:
1.
2.
3.
4.
5.
6.
7.
GENERAL CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS.
GENERAL CONTRACTOR TO COORDINATE SITE GRADING &
DRAINAGE WITH OWNER & GEOTECH ENGINEER OR CIVIL ENGINEER.
GENERAL CONTRACTOR TO VERIFY ALL CABINETRY WITH OWNER
PRIOR TO INSTALLATION.
THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK
AND CONSTRUCTION MEETS OR EXCEEDS ALL CURRENT FEDERAL,
STATE AND LOCAL CODES, ORDINANCES AND REGULATIONS, ETC.
THESE ARE TO BE CONSIDERED AS PART OF THE SPECIFICATIONS OF
THIS BUILDING AND SHOULD BE ADHERED TO EVEN IF THEY ARE IN
VARIANCE WITH THE PLAN.
THE STRUCTURAL DATA SHOWN ON THE PLANS ARE FOR
REFERENCE ONLY. GENERAL CONTRACTOR IS TO HAVE A LICENSED
STRUCTURAL ENGINEER REVIEW ALL STRUCTURAL ELEMENTS SUCH
AS JOIST SIZE AND SPACING, BEAM & HEADER SIZES, BEAM
CONNECTIONS, ETC.
CONTRACTOR TO ENSURE THAT PRE-FAB FIREPLACE
CONSTRUCTION MEETS OR EXCEEDS ALL APPLICABLE CODES. FLUE
HEIGHT TO MEET NECESSARY HEIGHT TO COMPLY WITH LOCAL
CODES.
CONTRACTOR TO COORDINATE GAS SERVICE REQUIREMENTS WITH
THE CITY.
N
5'-6"
5'-6"25' FRONT SETBACK25' REAR SETBACK12' VARIANCE120'55'
55'120'3'-8"71'44'
BRENTWOOD
ROAD
FRONT YARD
8'X14' POOL
PROPOSED HOME SITE
3163 SQ FT
BACKYARD
WATERFALL
FEATURE
WALK
CONC STEPPING
STONES
GATE GATE
WOOD
FENCE
WOOD
FENCE
WOOD
FENCE
PROJECT TITLEA 1.0BRENTWOODCONTENTSSITE PLAN DATESHEET1 SITE PLAN
3/16" = 1'-0"5/15/23
BCB30LBCB30L
B33SB4021B6222B62223DB27LCB3638R
LCB3836L3DB20B27R SB27L3DB27B42B42SB30ICEMAKER3DB12B42BCB72
BCB66B48 B48SB33213DB2021SB3321B33SB363DB15DW3DB24B9912B33B33 B48B48B48B24LSB33GRIDDLE3DB15B27LBCB48RGRILLB30LSMOKERB33SB4021B6222B62223DB27LCB3638R
LCB3836L3DB20B27R SB27L3DB27B42B42SB30ICEMAKER3DB12B42BCB72
BCB66B48 B48SB33213DB2021SB3321B33SB363DB15DW3DB24B9912B33B33 B48B48B48B24LSB33GRIDDLE3DB15B27LBCB48RGRILLB30LSMOKER
U392090FREEZERU202793LSHELVINGBCW3436 W3636W2436RBCW2436LBCW3436
BCW2436RW3336W3336W3336W3336W362114100100100100100100 3060SC3060SC7040FX4020FX3020FX3020FX3020FX3060FX3040FX3080
FX
3080
FX
3080
FX 6080 3080
FX
4080 30802880
3080
3080
248028802480
2480GASFIREPLACE286828806080 3080
FX
3080
FX
3040FX3040FX6020FXWOOD BURNING
FIREPLACE
UP cLcLE1
10
E1
10Exterior Elevation Front
E2
11
E2
11
Exterior Elevation LeftE4
11
E4
11
Exterior Elevation RightBS1
12
BS1
12
BS1
12
BS1
12
Building Section 1BS2
12
BS2
12
BS2
12
BS2
12Building Section 2
WS1
14
WS1
14WALL DETAIL
3'-10"4'-2"2'-6"9'-4"17'2'-7 3/4"6'-8"11'-4"11'-4"6'-8"
36'
44'
4'-1 3/4"3'-10 1/4"
5'3'4'-6"4'-2"
16'-8"5'-6 1/2"21'-9 1/2"2'-7 3/4"5'-9"6'-8"5'-7"16'-2"8'11'-10"17'71'6'-6"8'8'9'-6"5'-2"4'-10"5'-8"5'-4"2'-10 1/2"12'-3"2'-10 1/2"32'10'11'18'71'20'-4"8'-4"4'-4"19'-8"
44'
8'10'23'-6"8'-6"2'-10"8'
2'-8"
6'-8"4'7'-4"3'-10"16'
9'-4"26'-4 1/2"
2'-2"4'-4"
6'-2"7'-2"7'-6"3'-6"2'-8"2'-8"5'-4"3'-8"6'-8"7'-8"12'-2"
2'-6"
5'-9 1/2"
6'-6"
4'7'12'-8"14'7'-8"7'-8"83'-8"91'-4"91'-4"71'91'-4"8'-3 1/2"
10'-4"
9'-4" X 13'-4"
1919 SQ FT
35'-4" X 31'-8"
7'-8" X 7'-8"
15'-4" X 9'-8"
3'-11" X 5'-9"
6'-0" X 3'-2"
18'-10" X 17'-6"16'-2" X 17'-4"
5'-0" X 6'-4"
7'-9" X 9'-8"
7'-8" X 11'-6"
14'-4" X 16'-0"
44'-1" X 9'-11"
10'-0" X 10'-8"
11'-8" X 13'-8"
LIVING AREA
PORCH
PORCH
THREE-CAR GARAGE
PANTRY
MUD
CLOSET
1/2
MASTER BDRM
BATH
SAFE
ROOM
MICROWAVEFOYERU/C REFDININGKITCHEN
LIVING
12' CEILING
12' CEILING
12' CEILING
12' CEILING
12' CEILING
12' CEILING
12' CEILING
12' CEILING
12' CEILING
OPEN TO ABOVE
12' CEILING
TLT.
8'X14' POOL
8" CMU
BLOCKS
1 1/2"
FURR
12' CEILING 2"X6" WALL2"X6" WALL2"X6" WALL2"X6" WALL
(CONDITIONED)WASHER
DRYER
6' TUB
5'X7'
SHOWER
OUTDOOR
LIVING
GENERATORFOLD DOWN
STAIRWAY
REF/ FREEZER
REF/FREEZER
PROJECT TITLECONTENTSFLOOR PLAN BASEMENT LEVELDATESHEETA 2.0GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS ONLY. IF DIMENSION
IS NOT CALLED OUT, VERIFY DIMENSION WITH DESIGNER.
ALL INTERIOR WALLS TO BE COVERED WITH 5/8" GYPSUM BOARD,
WITH METAL CORNERS REINFORCING. TAPE, FLOAT & SAND.
ALL BATH & TOILET AREA WALLS AND CEILINGS ADJACENT TO WET
AREAS TO HAVE WATER RESISTANT GYPSUM BOARD.
BEDROOM WINDOWS TO HAVE A MINIMUM NET CLEAR OPENING OF 4
SQ. FT., A MINIMUM NET CLEAR OPERABLE WIDTH OF 20", A MINIMUM
NET CLEAR OPERABLE HEIGHT OF 22" AND HAVE A MAXIMUM FINISH
SILL HEIGHT OF 44" FROM FINISH FLOOR.
ALL GLASS LOCATED WITHIN 18" OF FLOOR, 24" OF A DOOR OR
LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS OR
SHOWERS TO BE TEMPERED.
BATHROOMS, UTILITY ROOMS, AND RANGE HOODS TO BE VENTED TO
THE OUTSIDE AS REQUIRED BY CODE.
ALL INTERIOR & EXTERIOR STUDS TO BE 2X4.
ALL EXTERIOR WALLS CONTINUOUSLY SHEATHED W/ 1/2" OSB BOARD
AND VAPOR BARRIER. VENEER SHOULD BE BEHIND ALL SETBACK LINES.
GC TO COORDINATE ALL DOOR & WINDOW OPENING SIZES WITH
SELECTED MANUFACTURER(S).
GENERAL HVAC SYSTEM NOTES:
1.
2.
3.
4.
MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM
DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER. HVAC
SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWINGS
AND SUBMIT IT TO CONTRACTOR, OWNER AND EQUIPMENT
SUPPLIER FOR FINAL REVIEW AND APPROVAL
PROVIDE DUCTING FOR ALL EXHAUST FANS, THE VENT-A-HOOD,
AND THE DRYER VENT.
LOCATE UNITS AS SPECIFIED BY HVAC SUBCONTRACOR.
GENERAL PLUMBING NOTES:
1.
2.
3.
4.
5.
PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR
ADHERING TO ALL APPLICABLE CODES AND SAFETY
REQUIREMENTS.
PROVIDE GAS SERVICE TO ALL WATER HEATERS AND HVAC
EQUIPMENT AS REQUIRED.
IF WALL PLATES OR JOISTS ARE CUT DURING THE INSTALLATION
OF PLUMBING FIXTURES OR EQUIPMENT, PROVIDE BRACING TO
TIE FRAMING BACK TOGETHER.
ALL GAS WATER HEATERS TO BE VENTED ATO TOPOUT.
ALL PLUMBING AND MECHANICAL VENT STACKS TO BE LOACTED
BY LICENSED CONTRACTORS. IF CHASES ARE REQUIRED, NOTIFY
DESIGNER PRIOR TO START OF CONSTRUCTION.
1 LEVEL 1
1/4" = 1'-0"BRENTWOOD5/15/23
DN
FILE
CAB
3DB12213DB1221SB3221
3DB1221DESK3DB1221B5621B5621FILE
CAB
3DB12213DB1221SB3221
3DB1221DESK3DB1221B5621B5621BOOKSBOOKS26803040FX 3040FX 3040FX 3040FX 3040FX 3040FX
2880
5020FX 3060SC3060SC4012FX3060SC3060SC2680288026802680
2680
28803050FX 3050FX 3050FX
3040FX3040FX3040FX2'-10 1/2"12'-3"2'-10 1/2"2'-7 3/4"3'-10"16'-2"
4'-10"3'-2"20'16'
44'2'-7 3/4"5'-9"6'-8"19'-3"7'-4"39'2'-6"9'-9 1/2"2'-2 1/2"14'-6"6'-6"18'39'7'-7 3/4"
15'-4"7'21'-8"
44'8'-8"9'-4"12'-2"
11'-4"6'-4"4'-8"7'-4"7'-2"6'-6"2'-6"13'-11 1/2"7'4'-4"3'18'-10" X 17'-2"
1244 SQ FT
15'-4" X 14'-2"
6'-0" X 6'-10"
14'-8" X 17'-4"
4'-6" X 7'-0"
10'-8" X 6'-2"
21'-2" X 21'-0"
6'-8" X 8'-4"
6'-8" X 8'-8"
LIVING AREA
OPEN BELOW
BEDROOM 3
CLOSET
CLOSET
BEDROOM 2
BATH 2
LOFT/ STUDY
10' CEILING
10' CEILING
10' CEILING
RAILING
RAILING
CLOSET
CLOSET
2"X6" WALL
2"X6" WALL2"X6" WALLHVAC
PROJECT TITLECONTENTSFLOOR PLAN LEVEL 2DATESHEETA 2.0MAIN LEVEL H/C
SECOND LEVEL H/C
TOTAL H/C
PORCHES
1919 SF
1244 SF
3163 SF
658 SF
1068 SF
4889 SF
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS ONLY. IF DIMENSION
IS NOT CALLED OUT, VERIFY DIMENSION WITH DESIGNER.
ALL INTERIOR WALLS TO BE COVERED WITH 5/8" GYPSUM BOARD,
WITH METAL CORNERS REINFORCING. TAPE, FLOAT & SAND.
ALL BATH & TOILET AREA WALLS AND CEILINGS ADJACENT TO WET
AREAS TO HAVE WATER RESISTANT GYPSUM BOARD.
BEDROOM WINDOWS TO HAVE A MINIMUM NET CLEAR OPENING OF 4
SQ. FT., A MINIMUM NET CLEAR OPERABLE WIDTH OF 20", A MINIMUM
NET CLEAR OPERABLE HEIGHT OF 22" AND HAVE A MAXIMUM FINISH
SILL HEIGHT OF 44" FROM FINISH FLOOR.
ALL GLASS LOCATED WITHIN 18" OF FLOOR, 24" OF A DOOR OR
LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS OR
SHOWERS TO BE TEMPERED.
BATHROOMS, UTILITY ROOMS, AND RANGE HOODS TO BE VENTED TO
THE OUTSIDE AS REQUIRED BY CODE.
ALL INTERIOR & EXTERIOR STUDS TO BE 2X4.
ALL EXTERIOR WALLS CONTINUOUSLY SHEATHED W/ 1/2" OSB BOARD
AND VAPOR BARRIER. VENEER SHOULD BE BEHIND ALL SETBACK LINES.
GC TO COORDINATE ALL DOOR & WINDOW OPENING SIZES WITH
SELECTED MANUFACTURER(S).
GENERAL HVAC SYSTEM NOTES:
1.
2.
3.
4.
MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM
DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER. HVAC
SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWINGS
AND SUBMIT IT TO CONTRACTOR, OWNER AND EQUIPMENT
SUPPLIER FOR FINAL REVIEW AND APPROVAL
PROVIDE DUCTING FOR ALL EXHAUST FANS, THE VENT-A-HOOD,
AND THE DRYER VENT.
LOCATE UNITS AS SPECIFIED BY HVAC SUBCONTRACOR.
GENERAL PLUMBING NOTES:
1.
2.
3.
4.
5.
PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR
ADHERING TO ALL APPLICABLE CODES AND SAFETY
REQUIREMENTS.
PROVIDE GAS SERVICE TO ALL WATER HEATERS AND HVAC
EQUIPMENT AS REQUIRED.
IF WALL PLATES OR JOISTS ARE CUT DURING THE INSTALLATION
OF PLUMBING FIXTURES OR EQUIPMENT, PROVIDE BRACING TO
TIE FRAMING BACK TOGETHER.
ALL GAS WATER HEATERS TO BE VENTED ATO TOPOUT.
ALL PLUMBING AND MECHANICAL VENT STACKS TO BE LOACTED
BY LICENSED CONTRACTORS. IF CHASES ARE REQUIRED, NOTIFY
DESIGNER PRIOR TO START OF CONSTRUCTION.
1 LEVEL 2
1/4" = 1'-0"
3-CAR GARAGE
TOTAL UNDER ROOF BRENTWOOD5/15/23
UP
R6
R6R6
R6
R6 R6
R6
R6
R6
R6
R6R6
R6
R6
R6
R6
R6
R6
R6R6
R6
R6
R6
R6
R6 R6 R6
R6R6
R6
R4
R4R4
R4
R4R4
R6
R6
R6
R6
R6
R6
R6
R4R4
R4 R4
R4R4
R6
R6
R6
R6R6
R6
R6 R6
R6 R6
R4
R4
R4
R4 R4
R4 R4
R4
R6R6 R6R6
R6R6R6
R6 R6R6R6
R6R6 R6R6MICROWAVEU/C REF2"X6" WALL2"X6" WALL2"X6" WALL2"X6" WALL
(CONDITIONED)ELECTRICAL SCHEDULE
DESCRIPTION
2D
SYM
BOL
WROUGHT IRON CANDELABRA
GEOBOX SCONCE LARGE
TRADITIONAL FLUSH DOME
BRYANT SCONCE 3
CLASSIC CEILING FAN
RECESSED DOWN LIGHT 4
RECESSED DOWN LIGHT 6
R4
R6
R4
R6
RECESSED SOFFIT LIGHT
STAINED T&G SOFFIT
STAINGED T&G
WOOD CEILING
CEILING FAN
INT. RECESSED LIGHT
GYP. BOARD TYP.
INT. RECESSED LIGHT
SURFACE MOUNTED LIGHT
RECESSED SOFFIT LIGHT
STAINED T&G SOFFIT
GYP. BOARD TYP.
STAINED T&G CEILING
EXT. WALL SCONCE
RECESSED SOFFIT LIGHT
STAINED T&G SOFFIT
INT. RECESSED LIGHT
CEILING FAN
VANITY LIGHT
12'-0"
12'-0"
12'-0"
12'-0"
12'-0"
12'-0"
12'-0"
12'-0"
12'-0"
12'-0"
12'-0"PROJECT TITLECONTENTSREFLECTED CEILINGPLAN-LEVEL 1DATESHEETA 3.0GENERAL ELECTRICAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ELECTRICAL PLANS, IF INCLUDED, ILLUSTRATE BASIC DESIGN INTENT
ONLY. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
CONTRACTOR AND ELECTRICAL SUBCONTRACTOR TO REVIEW THE
PLANS AND WALK THROUGH THE JOB TO VERIFY THAT THE DESIGN
INTENT IS MAINTAINED. GENERAL CONTRACTOR TO NOTIFY DESIGNER
IF ANY ITEMS ARE DIFFERENT FROM THE ELECTRICAL PLANS BEFORE
THE INSTALLATION OF FIXTURES, SWITCHES, ETC.
GAS OR ELECTRICAL SERVICE TO BE PROVIDED AS REQUIRED FOR ALL
APPLIANCES AND EQUIPMENT SUCH AS REFRIGERATOR, DISHWASHER,
DISPOSAL, FREEZER, COOKTOP, WASHER, DRYER, OVENS, HVAC
EQUIPMENT, ALARM PANEL, ETC. PROVIDE OUTLET ABOVE RANGE FOR
MICROWAVE OR HOOD VENT IF FINAL KITCHEN LAYOUT REQUIRES.
ALL OUTLETS THAT ARE NEAR ANY WATER CONDITIONS TO BE G.F.C.I.
TYPE PER CODE.
SWITCHES AND OUTLETS TO BE COORDINATED WITH THE OWNER AND
COLOR MATCHED WITH THE INTERIOR TRIM.
CONTRACTOR TO VERY ALL LOCATIONS OF PHONE OUTLETS,
COMPUTER OUTLETS, AND ELECTRONIC DEVIDE OUTLETS. ALL
COMPUTER OUTLETS TO BE ON A DEDICATEDD CIRCUIT.
CONTRACTOR TO VERIFY THE LOCATIONS OF THE CABLE TV OUTLETS.
VERIFY TRIM SIZE FOR ALL DOORS AND WINDOWS BEFORE SWITCHES
ARE LOCATED. LOCATED SWITCHES CLOSE TO TRIM AND ALIGN WITH
EACH OTHER IF THERE ARE MULTIPLE SWITCHES.
CONTRACTOR TO VERIFY WITH DESIGNER ALL LANDSCAPE AND
EXTERIOR LIGHTING CIRCUITS AND SWITCHES.
PROVIDE HARDWIRED SMOKE DETECTORS, WITH BATTERY BACKUP,
ON ALL FLOORS. VERIFY WITH LOCAL CODE REQUIREMENTS.
G.C. TO VERIFY ALL LIGHTING & SWITCH LOCATIONS WITH OWNER.
1 LEVEL 1 RCP
1/4" = 1'-0"
REFLECTED CEILING LEGEND
BRENTWOOD5/15/23
DN
R4 R4
R4R4
R6R6 R6
R6R6R6
R6 R6
R6R6
R6 R6
R6R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6R6
R6
R6 R6
R6
R6 R6R6
R6
2"X6" WALL
2"X6" WALL2"X6" WALLRECESSED SOFFIT LIGHT
STAINED T&G SOFFIT
INT. RECESSED LIGHT
RECESSED SOFFIT LIGHT
STAINED T&G SOFFIT
CEILING FAN
INT. RECESSED LIGHT
VANITY LIGHT
SURFACE MOUNTED LIGHT
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
23'-7"
HVAC
ELECTRICAL SCHEDULE
DESCRIPTION
2D
SYM
BOL
WROUGHT IRON CANDELABRA
GEOBOX SCONCE LARGE
TRADITIONAL FLUSH DOME
BRYANT SCONCE 3
CLASSIC CEILING FAN
RECESSED DOWN LIGHT 4
RECESSED DOWN LIGHT 6
R4
R6
R4
R6
PROJECT TITLECONTENTSREFLECTED CEILINGPLAN-LEVEL 2DATESHEETA 3.1REFLECTED CEILING LEGEND
1 LEVEL 2 RCP
1/4" = 1'-0"
GENERAL ELECTRICAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ELECTRICAL PLANS, IF INCLUDED, ILLUSTRATE BASIC DESIGN INTENT
ONLY. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
CONTRACTOR AND ELECTRICAL SUBCONTRACTOR TO REVIEW THE
PLANS AND WALK THROUGH THE JOB TO VERIFY THAT THE DESIGN
INTENT IS MAINTAINED. GENERAL CONTRACTOR TO NOTIFY DESIGNER
IF ANY ITEMS ARE DIFFERENT FROM THE ELECTRICAL PLANS BEFORE
THE INSTALLATION OF FIXTURES, SWITCHES, ETC.
GAS OR ELECTRICAL SERVICE TO BE PROVIDED AS REQUIRED FOR ALL
APPLIANCES AND EQUIPMENT SUCH AS REFRIGERATOR, DISHWASHER,
DISPOSAL, FREEZER, COOKTOP, WASHER, DRYER, OVENS, HVAC
EQUIPMENT, ALARM PANEL, ETC. PROVIDE OUTLET ABOVE RANGE FOR
MICROWAVE OR HOOD VENT IF FINAL KITCHEN LAYOUT REQUIRES.
ALL OUTLETS THAT ARE NEAR ANY WATER CONDITIONS TO BE G.F.C.I.
TYPE PER CODE.
SWITCHES AND OUTLETS TO BE COORDINATED WITH THE OWNER AND
COLOR MATCHED WITH THE INTERIOR TRIM.
CONTRACTOR TO VERY ALL LOCATIONS OF PHONE OUTLETS,
COMPUTER OUTLETS, AND ELECTRONIC DEVIDE OUTLETS. ALL
COMPUTER OUTLETS TO BE ON A DEDICATEDD CIRCUIT.
CONTRACTOR TO VERIFY THE LOCATIONS OF THE CABLE TV OUTLETS.
VERIFY TRIM SIZE FOR ALL DOORS AND WINDOWS BEFORE SWITCHES
ARE LOCATED. LOCATED SWITCHES CLOSE TO TRIM AND ALIGN WITH
EACH OTHER IF THERE ARE MULTIPLE SWITCHES.
CONTRACTOR TO VERIFY WITH DESIGNER ALL LANDSCAPE AND
EXTERIOR LIGHTING CIRCUITS AND SWITCHES.
PROVIDE HARDWIRED SMOKE DETECTORS, WITH BATTERY BACKUP,
ON ALL FLOORS. VERIFY WITH LOCAL CODE REQUIREMENTS.
G.C. TO VERIFY ALL LIGHTING & SWITCH LOCATIONS WITH OWNER.BRENTWOOD5/15/23
4 : 124 : 124 : 124 : 12
4 : 12
4 : 12 4 : 124 : 124 : 124 : 124 : 124 : 12
4 : 124 : 12
4 : 124 : 12
CRICKET
CHIMNEY
ARCHITECTURAL ASPHALT
SHINGLES
42" OVERHANG TYP.
RIDGE CAP
ARCHITECTURAL ASPHALT
SHINGLES
42" OVERHANG PROJECT TITLECONTENTSROOF PLANDATESHEETA 4.0GENERAL ROOF NOTES:
1.
2.
3.
4.
5.
6.
TYPICAL 10:12 PITCH FRONT TO BACK, 12:12 PITCH SIDE TO
SIDE. ASPHALT SHINGLES UNLESS OTHERWISE STATED.
TYPICAL 3:12 PITCH AT STANDING SEAM METAL ROOF.
PROVIDE SCREENED VENTS @ EACH 3RD JOIST SPACE @
ALL ATTIC EAVES.
USE 1/2" EXTERIOR PLYWOOD AT ALL EXPOSED EAVES.
USE ARCHITECTURAL ASPHALT SHINGLE ROOFING AND
UNDERLAY PER MANUFACTURERS SPECIFICATIONS
UNLESS NOTED OTHERWISE.
LOCATE ALL ROOF PENETRATING PLUMBING PIPES ON
THE "BACK" OF THE HOUSE.
NEW GUTTERS & DOWNSPOUTS THROUGHOUT HOUSE -
VERIFY W/ OWNER.
PROVIDE ATTIC VENTILATION AS APPROVED BY OWNER &
REQUIRED BY CODE BASE ON ATTIC AREA.
1 ROOF PLAN
1/4" = 1'-0"
GENERAL INSULATION NOTES:
1.
2.
3.
FLOORS OVER UNHEATED SPACE TO HAVE R-30 MIN INSULATION
BETWEEN JOISTS.
HVAC DUCTS LOCATED IN UNHEATED SPACES TO BE INSULATED
WITH R-8. CONTRACTOR TO VERIFY WITH LOCAL CODES.
ALL EXPOSED INSULATION TO HAVE A FLAME SPREAD RATING OF
LESS THAN 25 AND A SMOKE DENSITY RATING OF LESS THAN 450.BRENTWOOD5/15/23
4
12
4
12
4
12 4
12
Top of Subfloor - 1st Floor
0'-0"
Top of Wall
12'-1 1/8"
Top of Subfloor - 2nd Floor
13'-5 7/8"
Header
21'-6 3/8"
Top of Wall
23'-7"
Highest Ridge
30'-6 13/16"
Top of Brick
1'-6"
Top of Wall
12'-1 1/8"10'-7 1/8"Top of Subfloor - 2nd Floor
13'-5 7/8"1'-4 3/4"Top of Wall
23'-7"10'-1 1/8"1'-6"Top of Subfloor
0'-0"
ARCHITECTURAL ASPHALT
SHINGLES
FRIEZE
JAMES HARDIE BOARD & BATTEN
VERTICAL SIDING
FASCIA
42" OVERHANG TYP.
BRICK VENEER ACCENT WALL
CUSTOM 4' ENTRY DOOR
4
12
4
12
4
12
4
12 4
12
Top of Slab
0'-0"
Top of Brick
1'-6"1'-6"Top of Wall
12'-1 1/8"10'-7 1/8"Top of Subfloor - 2nd Floor
13'-5 7/8"1'-4 3/4"Header
21'-6 3/8"8'-0 1/2"Top of Wall
23'-7"2'-0 5/8"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
12'-1 1/8"12'-1 1/8"Top of Subfloor - 2nd Floor
13'-5 7/8"1'-4 3/4"Top of Wall
23'-7"10'-1 1/8"Highest Ridge
30'-6 13/16"6'-11 13/16"PROJECT TITLECONTENTSELEVATIONSDATESHEETA 5.0GENERAL ELEVATION NOTES:
1.
2.
3.
EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT
ALL CHIMNEY CONNECTIONS BETWEEN ROOFS, WALLS,
CHIMNEYS, PROJECTIONS AND PENETRATIONS AS
REQUIRED BY APPROVED CONSTRUCTION PRACTICES.
ALL PLUMBING AND MECHANICAL VENTS TO BE
LOCATED CLOSE TOGETHER WITHIN THE PROVIDED
CHASE SPACE WHEN POSSIBLE TO MINIMIZE THE
NUMBER OF ROOF PENETRATIONS. ALL METAL AND PVC
VENTS AND PENETRATIONS TO BE PRIMED AND PAINTED
TO CLOSELY MATCH THE ROOF COLOR.
CONTRACTOR TO LOCATE GUTTERS AND DOWN SPOUTS
TO ALLOW POSITIVE DRAINAGE AWAY FROM THE
BUILDING. GUTTERS AND DOWN SPOUTS TO CLOSELY
MATCH TRIM COLOR. VERIFY WITH OWNER ON GUTTER
AND DOWN SPOUT NEEDS.
2 EAST ELEVATION
1/4" = 1'-0"
1 SOUTH ELEVATION
1/4" = 1'-0"BRENTWOODBRENTWOOD5/15/23
4
124
12
4
12
4
12
4
12
4
12
Top of Subfloor - 1st Floor
0'-0"
Top of Lower Pony Wall
1'-6"1'-6"Header
8'-0 1/2"6'-6 1/2"Top of Wall
12'-1 1/8"4'-0 5/8"Top of Subfloor - 2nd Floor
13'-5 7/8"1'-4 3/4"Header
21'-6 3/8"8'-0 1/2"Top of Wall
23'-7"2'-0 5/8"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
12'-1 1/8"12'-1 1/8"Top of Subfloor - 2nd Floor
13'-5 7/8"1'-4 3/4"Header
21'-6 3/8"8'-0 1/2"Top of Wall
23'-7"2'-0 5/8"Highest Ridge
30'-6 13/16"6'-11 13/16"4
12
4
12
4
12
4
12
4
12
4
12
Top of Subfloor - 1st Floor
0'-0"
Header
8'-0 1/2"8'-0 1/2"Top of Wall
12'-1 1/8"4'-0 5/8"Top of Subfloor - 2nd Floor
13'-5 7/8"1'-4 3/4"Header
21'-6 3/8"8'-0 1/2"Top of Wall
23'-7"2'-0 5/8"Highest Ridge
30'-6 13/16"6'-11 13/16"Top of Subfloor - 1st Floor
0'-0"
Top of Brick
1'-6"1'-6"Header
8'-0 1/2"6'-6 1/2"Top of Wall
12'-1 1/8"4'-0 5/8"Top of Subfloor - 2nd Floor
13'-5 7/8"1'-4 3/4"Header
21'-6 3/8"8'-0 1/2"Top of Wall
23'-7"2'-0 5/8"PROJECT TITLECONTENTSELEVATIONSDATESHEETA 5.1GENERAL ELEVATION NOTES:
1.
2.
3.
EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT
ALL CHIMNEY CONNECTIONS BETWEEN ROOFS, WALLS,
CHIMNEYS, PROJECTIONS AND PENETRATIONS AS
REQUIRED BY APPROVED CONSTRUCTION PRACTICES.
ALL PLUMBING AND MECHANICAL VENTS TO BE
LOCATED CLOSE TOGETHER WITHIN THE PROVIDED
CHASE SPACE WHEN POSSIBLE TO MINIMIZE THE
NUMBER OF ROOF PENETRATIONS. ALL METAL AND PVC
VENTS AND PENETRATIONS TO BE PRIMED AND PAINTED
TO CLOSELY MATCH THE ROOF COLOR.
CONTRACTOR TO LOCATE GUTTERS AND DOWN SPOUTS
TO ALLOW POSITIVE DRAINAGE AWAY FROM THE
BUILDING. GUTTERS AND DOWN SPOUTS TO CLOSELY
MATCH TRIM COLOR. VERIFY WITH OWNER ON GUTTER
AND DOWN SPOUT NEEDS.
2 WEST ELEVATION
1/4" = 1'-0"
1 NORTH ELEVATION
1/4" = 1'-0"BRENTWOOD5/15/23
Top of Slab
-0'-8"
Top of Subfloor - 1st Floor
0'-0"8"Top of Brick
1'-6"1'-6"Header
8'-0 1/2"6'-6 1/2"Top of Wall
12'-1 1/8"4'-0 5/8"Top of Subfloor - 2nd Floor
13'-5 7/8"1'-4 3/4"Rough Ceiling - 2nd Floor
23'-7"10'-1 1/8"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
12'-1 1/8"12'-1 1/8"Top of Subfloor - 2nd Floor
13'-5 7/8"1'-4 3/4"Header
21'-6 3/8"8'-0 1/2"Top of Wall
23'-7"2'-0 5/8"Highest Ridge
30'-6 13/16"6'-11 13/16"23'-7"GARAGE
DINING/KITCHEN
LIVING
LOFT/ STUDY
OUTDOOR LIVING
Top of Subfloor - 1st Floor
0'-0"
Header
21'-6 3/8"21'-6 3/8"Top of Wall
23'-7"2'-0 5/8"Top of Subfloor - 1st Floor
0'-0"
Header
8'-0 1/2"8'-0 1/2"Top of Wall
12'-1 1/8"4'-0 5/8"Top of Subfloor - 2nd Floor
13'-5 7/8"1'-4 3/4"Header
21'-6 3/8"8'-0 1/2"Top of Wall
23'-7"2'-0 5/8"MASTER
BEDROOM
BEDROOM #2
LIVING
SAFE
ROOM PROJECT TITLECONTENTSBUILDINGSECTIONDATESHEETA 6.0GENERAL ELEVATION NOTES:
1.
2.
3.
EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT
ALL CHIMNEY CONNECTIONS BETWEEN ROOFS, WALLS,
CHIMNEYS, PROJECTIONS AND PENETRATIONS AS
REQUIRED BY APPROVED CONSTRUCTION PRACTICES.
ALL PLUMBING AND MECHANICAL VENTS TO BE
LOCATED CLOSE TOGETHER WITHIN THE PROVIDED
CHASE SPACE WHEN POSSIBLE TO MINIMIZE THE
NUMBER OF ROOF PENETRATIONS. ALL METAL AND PVC
VENTS AND PENETRATIONS TO BE PRIMED AND PAINTED
TO CLOSELY MATCH THE ROOF COLOR.
CONTRACTOR TO LOCATE GUTTERS AND DOWN SPOUTS
TO ALLOW POSITIVE DRAINAGE AWAY FROM THE
BUILDING. GUTTERS AND DOWN SPOUTS TO CLOSELY
MATCH TRIM COLOR. VERIFY WITH OWNER ON GUTTER
AND DOWN SPOUT NEEDS.
2 BUILDING SECTION 2
1/4" = 1'-0"
1 BUILDING SECTION 1
1/4" = 1'-0"BRENTWOOD5/15/23
71'91'-4"10'7'54'20'-4"10'-4"19'-8"
44'
14'7'-8"4'-4"71'8'-4"83'-8"91'-4"36'
44'
8'
21'-9 1/2"5'-6 1/2"16'-8"7'-6 1/2"23'-6"8'-6"9'-4"26'-4 1/2"8'-3 1/2"
THICKENED SLAB FOOTING
W/ (2) #4 REBAR CONT. &
#4 REBAR @24" O.C. HORZ.
AT LOAD BEARING INT. WALLS
4" CONCRETE SLAB WITH 6"X6", #10/#10
W.W.M. OVER 15 MIL STEGO WRAP ON MIN.
4" COMPACTED FILL
PORCH SLAB
4" CONCRETE SLAB WITH 6"X6", #10/#10
W.W.M. OVER 15 MIL STEGO WRAP ON MIN.
4" COMPACTED FILL
HOUSE SLAB
GARAGE SLABPORCH SLAB
4" CONCRETE SLAB WITH 6"X6", #10/#10
W.W.M. OVER 15 MIL STEGO WRAP ON MIN.
4" COMPACTED FILL
4" CONCRETE SLAB WITH 6"X6", #10/#10
W.W.M. OVER 15 MIL STEGO WRAP ON MIN.
4" COMPACTED FILL
THICKENED SLAB FOOTING
W/ (2) #4 REBAR CONT. &
#4 REBAR @24" O.C. HORZ.
AT LOAD BEARING INT. WALLS
PROJECT TITLECONTENTSFOUNDATION PLANDATESHEETA 7.02 FOUNDATION PLAN
1/4" = 1'-0"
GENERAL FOUNDATION NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
CONTRACTOR TO INSPECT THE JOB SITE AND EXCAVATED
CONDITIONS PRIOR TO STARTING CONSTRUCTION.
CONTRACTOR TO NOTIFY DESIGNER AND ENGINEER OF ANY
CONDITIONS REGARDING SOILS, GROUND WATER, OR ANY
OTHER ISSUE WHICH MAY REQUIRE ADDITIONAL OR SPECIAL
ENGINEERING DESIGN BY A LICENSED STRUCTURAL
ENGINEER.
CONTRACTOR TO REVIEW PLANS, ELEVATIONS, AND DETAILS
FOR DIMENSION OF FINISH FLOOR ABOVE TYPICAL GRADE.
CONTRACTOR TO NOTIFY DESIGNER IF THERE ARE ANY SITE
CONDITIONS THAT REQUIRE MODIFICATIONS TO DIMENSIONS
INDICATED ON PLANS, SECTIONS, OR EXTERIOR ELEVATIONS.
CONTRACTOR TO VERIFY FOOTING DEPTHS WITH LOCAL
FROST REQUIREMENTS OR EXISTING SOIL CONDITIONS;
WHICH EVER IS MORE RESTRICTIVE.
ALL FOOTINGS TO REST ON UNDISTURBED SOIL.
CONTRACTOR TO COORDINATE WITH LICENSED, BONDED
INSTALLER TO PROVIDE TERMITE TREATMENT WHICH
COMPLIES WITH ALL LOCAL BUILDING CODES.
PROVIDE 1/2" EXPANSION JOINT MATERIAL BETWEEN ALL
CONCRETE SLABS ON ABUTTING CONCRETE OR MASONRY
WALL OCCURRING IN EXTERIOR OR UNHEATED INTERIOR
AREAS.
UNLESS OTHERWISE NOTED, ALL SLABS ON GRADE TO BE
3500 PSI CONCRETE ON 4" GRAVEL FILL MINIMUM, WITH
6x6-10/10 WIRE MESH REINFORCING. INTERIOR SLABS TO BE
PLACED ON 15 MIL. STABILIZED POLYETHYLENE VAPOR
BARRIER. THICKEN SLAB TO 12" AT LOAD BEARING WALLS.
PROVIDE 1/4" DEEP SCORE CONTROL JOINTS AT MID POINTS
OF ALL GARAGE SLABS, BOTH DIRECTIONS NOT MORE THAN
20' APART.BRENTWOOD5/15/23
12'-1 1/8"1'-4 3/4"10'-1 1/8"ARCHITECTURAL ASHPHALT SHINGLES
SYNTHETIC ROOFING UNDERLAYMENT
1/2" PLYWOOD SHEATHING
RAFTER
R-38 INSULATION
CEILING JOIST
SUB-FASCIA
FASCIA
2"X4" WALL PLATE
WINDOW HEADER
CASEMENT WINDOW
3 1/2" R-15 BATT INSULATION
7/16" SHEATHING
HOUSE WRAP
2"X4" SILL PLATE
3/4" T&G SUBFLOOR
16" FLOOR TRUSS
JAMES HARDIE BOARD & BATTEN VERTICAL SIDING
WINDOW HEADER
CASEMENT WINDOW
3 1/2" BATT INSULATION
BRICK ROWLOCK
2"X4" SILL PLATE
BRICK VENEER
SLOPE FOR DRAINAGE
CMU BLOCK FOUNDATION WALL
CONCRETE FOOTING 24"W X 16"D
VERIFY W/STRUCTURAL AND SOILS
ENGINEERS
CONTINOUS REBAR AS REQ.
BEDROOM
BEDROOM
1/2" GYP. BOARD
WINDOW TRIM
BASEBOARD
FINISH FLOORING
3/4" T&G SUBFLOOR
1/2" GYP. BOARD
WINDOW TRIM
BASEBOARD
FINISH FLOORING
4" CONCRETE SLAB
15 MIL STEGO WRAP
VAPOR BARRIER
CRUSHED STONE FILL
COMPACTED SOIL PROJECT TITLECONTENTSDETAILSDATESHEETA 7.1GENERAL FRAMING NOTES:
1.
2.
THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL
WORK AND CONSTRUCTION MEETS OR EXCEEDS ALL CURRENT
FEDERAL, STATE & LOCAL CODES, ORDINANCES AND
REGULATIONS, ETC. THESE ARE TO BE CONSIDERED AS PART OF
THE SPECIFICATIONS OF THE BUILDING AND SHOULD BE ADHERED
TO EVEN IF THEY ARE IN VARIANCE WITH THE PLAN.
THE STRUCTURAL DATA SHOWN ON THE PLAN IS FOR REFERENCE
ONLY. GENERAL CONTRACTOR IS TO HAVE A LICENSED
STRUCTURAL ENGINEER REVIEW ALL STRUCTURAL ELEMENTS
SUCH AS JOIST SIZE & SPACING, BEAM AND HEADER SIZES, BEAM
CONNECTIONS, ETC.
*VERIFY FINAL SIZES WITH JOIST & BEAM MANUFACTURER.
GENERAL FRAMING NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL WOOD FRAMING IN CONTACT WITH CONCRETE OR
MASONRY TO BE PRESSURE TREATED.
ALL STUD WALLS TO BE FRAMED 16" O.C.
ALL ANGLED WALLS TO BE FRAMED AT 45 DEGREE ANGLE
UNLESS OTHERWISE NOTED.
MINIMUM HEADER SIZE AT SECOND AND THIRD FLOORS TO
BE (2) 2x6'S UNLESS OTHERWISE NOTED.
PROVIDE FULL SOLID BEARING OR STUD BEARING UNDER ALL
BEAM BEARING POINTS.
ALL BEAMS TO HAVE TRIPLE STUD BEARING AT EACH END.
ALL STRUCTURAL STEEL TO CONFORM WITH ASTM
SPECIFICATIONS A-36.
STAIR CONSTRUCTION TO CONSIST OF (3) 2x12 STRINGERS,
5/4" OR 2x THICK TREADS & 3/4" THICK RISERS OR MATERIALS
FABRICATED BY A COMPONENT MANUFACTURER.
HANDRAILS TO BE MOUNTED 32"-34" ABOVE STAIR NOSING.
GUARDRAILS TO BE MOUNTED AT 36" HEIGHT.
FLOOR FRAMING LAYOUT TO BE COORDINATED WITH THE
GENERAL AND HVAC CONTRACTORS TO PROVIDE ACCESS
CHASES AND UNOBSTRUCTED RUNS FOR HVAC DUCT WORK.BRENTWOOD5/15/23TYPICAL WALL SECTION
3/8"=1'