HomeMy WebLinkAboutZ-6808 Staff AnalysisFILE NO.: Z-6808
NAME: Robertson - Short -Form POD
LOCATION: 14109 Taylor Loop Road
DEVELOPER: ENGINEER:
Robertson Properties, LLC. Terry Burruss, Architects
109 Oak Lane 1202 Main Street, Suite 230
Little Rock, AR 72205 Little Rock, AR 72202
AREA: 0.93 acre NUMBER OF LOTS: 1 FT. NEW STREET: 0
ZONING: R-2 ALLOWED USES:
PROPOSED USE:
Single -Family Residential
General/Professional Office
VARIANCES/WAIVERS REQUESTED: None requested.
A. PROPOSAL/REQUEST:
The applicant proposes to rezone the property at 14109
Taylor Loop Road from R-2 to POD in order to utilize the
existing 2,069 square foot single family residential
structure as general/professional offices. The applicant
also proposes to make a 1,008 square foot addition on the
east side of the existing structure for additional office
space. This building addition will be "Phase II" of the
project.
The applicant proposes to remove the existing concrete
drive at the southwest corner of the property and construct
a new asphalt drive near the northwest corner of the
property which will extend along the north side of the
building and access a small parking area in the rear yard.
The proposed parking area contains 11 spaces. The
applicant has designed the parking area so that two (2)
existing oak trees can be preserved. The applicant is also
proposing one (1) parking space on the west side of the
building.
FILE NO.: Z-6808 (Cont.)
The applicant is proposing no development within the east
245 feet of the property. The existing trees within this
area will be preserved.
The applicant proposes to utilize the building for
general/professional offices. The proposed hours of
operation are from 8:30 a.m. - 5:30 p.m., Monday -Friday.
One (1) ground -mounted sign is proposed to be located near
the southwest corner of the building. The sign will be a
monument -type sign, with a maximum height of 6 feet and a
maximum area of 64 square feet.
No dumpster/trash receptacle area is proposed on the site.
B. EXISTING CONDITIONS:
C.
i�
There is an existing one-story brick and frame single
family residential structure on the site, with an existing
driveway at the southwest corner of the property. There
are single family residences to the north and south, along
the east side of Taylor Loop Road, and to the east. There
is an animal clinic (PD -O) and a beauty salon (PCD) across
Taylor Loop Road to the west, with additional single family
residences to the southwest.
NEIGHBORHOOD COMMENTS:
As of this writing, staff has received two (2) phone calls
from persons requesting information on this application.
The Westchester/Heatherbrae, Secluded Hills and Westbury
Neighborhood Associations were notified of the public
hearing.
ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Taylor Loop Road is listed on the Master Street Plan as a
minor arterial. A dedication of right-of-way to 45 feet
from centerline is required.
2. Provide design of street conforming to "MSP" (Master
Street Plan). Construct one-half street improvements to
this street including 5 -foot sidewalk with planned
development.
3. Plans of all work in right-of-way shall be submitted for
approval prior to start of work.
4. Stormwater detention ordinance applies to this property.
5. Prepare a letter of pending development addressing street
lights as required by Section 31-403 of the Little Rock
Code. All requests should be forwarded to Traffic
Engineering.
E
FILE NO.: Z-6808 (Cont.)
6. Taylor Loop has a 1996 average daily traffic count of
4,400.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available, not adversely affected.
AP&L: No Comment received.
Arkla: No Comment.
Southwestern Bell: No Comment received.
Water: An acreage charge of $300 per acre applies in
addition to normal charglas if additional water service is
required.
Fire Department: No Comment.
County Planning: No Comment received.
CATA: No Comment received.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division:
This request is located in the River Mountain Planning
District. The Land Use Plan shows Transition at this
location. The proposed zone change from R-2 Single Family
Residential to a Planned Office, with the use and design
proposed, is consistent with the Land Use Plan.
City Recognized Neighborhood Action Plan: This area is
covered by the River Mountain Neighborhood Action Plan.
The neighborhood plan does not provide any recommendation
relevant to this application.
Landscape Issues:
Unless a co -access is provided along the northern
perimeter, the buffer should not drop below a width of five
feet. A portion of this buffer is only 2 feet wide.
A six foot high opaque screen is required along the
northern, eastern and southern perimeters. This screen may
be a wooden fence with its face side directed outward or
dense evergreen plantings. Credit toward fulfilling this
requirement can be given when preserving existing trees.
The City Beautiful Commission recommends preserving as many
trees as feasible.
3
FILE NO.: Z-6808 (Cont.)
G. ANALYSIS:
The applicant submitted a revised site plan and additional
information to staff on February 2, 2000. The revised site
plan shows the sign location and additional right-of-way
dedication as required. The proposed driveway has been
shifted slightly to the south to provide an increased
buffer area along the north property line. The applicant
will use a combination of opaque fencing and dense
evergreen plantings as screening along the north property
line and dense evergreen plantings along the south property
line.
The proposed site plan provides for 12 on-site parking
spaces. The ordinance would typically require 7 spaces for
an office development of this size. Staff supports the
parking plan as proposed.
As noted, the revised site plan shows the required right-
of-way dedication. The applicant is proposing to make in -
lieu contribution for the required street improvements.
Staff feels that the applicant has done a good job in
addressing the outstanding issues as raised by the
Subdivision Committee review. The proposed site plan and
use of the property is very similar to the recently
approved planned development for Steve Pinter Century 21
Realty along the east side of Jerry Drive to the northeast.
The proposed POD should prove to be a very good development
within this area of Transition along the east side of
Taylor Loop Road.
H. STAFF RECOMMENDATIONS:
Staff recommends approval of the proposed POD rezoning
subject to the following conditions:
1. Compliance with the requirements as noted in paragraphs
D, E and F of this report.
2. The POD will be for general/professional office uses
only.
3. Any site lighting should be low-level and directed away
from adjacent property.
4. The existing trees within the east 245 feet of the
property will be preserved.
5. The ground mounted sign shall be monument type, with a
maximum height of 6 feet and a maximum area of 64 square
feet.
4
FILE NO.: Z-6808 (Cont.
SUBDIVISION COMMITTEE COMMENT: (JANUARY 27, 2000)
Terry Burruss and Al Robertson were present, representing the
application. Staff described the POD site plan, noting that
hours of operation and signage details needed to be provided.
Staff noted that the two (2) parking spaces shown on the west
side of the building might have to be eliminated with the
additional right-of-way dedication for Taylor Loop Road. Mr.
Burruss stated that he would like to maintain one (1) space on
the west side of the building.
The Public Works requirements were briefly discussed. Mr.
Burruss noted that the requirements would be complied with. He
stated that he would like to do an in -lieu contribution for the
street improvements to Taylor Loop Road.
The landscape and buffer requirements were briefly discussed.
Bob Brown, Site Plan Review Specialist, noted that the northern
buffer needed to be increased to five (5) feet. Mr. Burruss
noted that the driveway from the street to the front building
line would be shifted to provide a larger buffer. He noted that
the two (2) foot buffer along the north side of the building
could be made up with additional landscaping. He stated that he
would meet with Mr. Brown on this issue.
After the discussion, the POD was forwarded to the full
Commission for resolution.
PLANNING COMMISSION ACTION:
(FEBRUARY 17, 2000)
Terry Burruss and Al Robertson were present, representing the
application. Staff briefly described the proposed POD, with a
recommendation of approval with conditions.
Chairman Berry asked to hear from the one (1) person present who
opposed the application.
Diana Armstrong addressed the Commission in opposition to the
application. She stated that the proposed development will
adversely effect the value of her property.
There was a general discussion of the Land Use Plan in this
area, specifically the area of Transition.
5
FILE NO.: Z-6808 (Cont.)
Jim Lawson, Director of Planning and Development, explained the
Transition designation, noting that single-family, multifamily
and office uses would be appropriate uses in Transition.
There was a motion to approve the application as recommended by
Staff. The motion passed by a vote of 9 ayes, 0 nays and 2
absent.
11
February 17, 2000
ITEM NO.: 8
NAME: Robertson - Short -Form POD
LOCATION: 14109 Taylor Loop Road
DEVELOPER: ENGINEER:
FILE NO.: Z-6808
Robertson Properties, LLC. Terry Burruss, Architects
109 Oak Lane 1202 Main Street, Suite 230
Little Rock, AR 72205 Little Rock, AR 72202
AREA: 0.93 acre NUMBER OF LOTS: 1 FT. NEW STREET: 0
ZONING: R-2 ALLOWED USES: Single -Family Residential
PROPOSED USE: General/Professional Office
VARIANCES/WAIVERS REQUESTED: None requested.
A. PROPOSAL/REQUEST:
The applicant proposes to rezone the property at 14109
Taylor Loop Road from R-2 to POD in order to utilize the
existing 2,069 square foot single family residential
structure as general/professional offices. The applicant
also proposes to make a 1,008 square foot addition on the
east side of the existing structure for additional office
space. This building addition will be "Phase II" of the
project.
The applicant proposes to remove the existing concrete
drive at the southwest corner of the property and construct
a new asphalt drive near the northwest corner of the
property which will extend along the north side of the
building and access a small parking area in the rear yard.
The proposed parking area contains 11 spaces. The
applicant has designed the parking area so that two (2)
February 17, 2000
SUBDIVISION
ITEM NO.: 8 (Cont.)
FILE NO.: Z-6808
existing oak trees can be preserved. The applicant is also
proposing one (1) parking space on the west side of the
building.
The applicant is proposing no development within the east
245 feet of the property. The existing trees within this
area will be preserved.
The applicant proposes to utilize the building for
general/professional offices. The proposed hours of
operation are from 8:30 a.m. - 5:30 p.m., Monday -Friday.
One (1) ground -mounted sign is proposed to be located near
the southwest corner of the building. The sign will be a
monument -type sign, with a maximum height of 6 feet and a
maximum area of 64 square feet.
No dumpster/trash receptacle area is proposed on the site.
B. EXISTING CONDITIONS:
There is an existing one-story brick and frame single
family residential structure on the site, with an existing
driveway at the southwest corner of the property. There
are single family residences to the north and south, along
the east side of Taylor Loop Road, and to the east. There
is an animal clinic (PD -O) and a beauty salon (PCD) across
Taylor Loop Road to the west, with additional single family
residences to the southwest.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received two (2) phone calls
from persons requesting information on this application.
The Westchester/Heatherbrae, Secluded Hills and Westbury
Neighborhood Associations were notified of the public
hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Taylor Loop Road is listed on the Master Street Plan as a
minor arterial. A dedication of right-of-way to 45 feet
from centerline is required.
2
February 17, 2000
SUBDIVISION
ITEM NO.: 8 (Cont.
FILE NO.: Z-6808
2. Provide design of street conforming to " MSP" (Master
Street Plan). Construct one-half street improvements to
this street including 5 -foot sidewalk with planned
development.
3. Plans of all work in right-of-way shall be submitted for
approval prior to start of work.
4. Stormwater detention ordinance applies to this property.
5. Prepare a letter of pending development addressing street
lights as required by Section 31-403 of the Little Rock
Code. All requests should be forwarded to Traffic
Engineering.
6. Taylor Loop has a 1996 average daily traffic count of
4,400.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available, not adversely affected.
AP&L: No Comment received.
Arkla : No Comment.
Southwestern Bell: No Comment received.
Water: An acreage charge of $300 per acre applies in
addition to normal charges if additional water service is
required.
Fire Department: No Comment.
County Planning: No Comment received.
LATA: No Comment received.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division:
This request is located in the River Mountain Planning
District. The Land Use Plan shows Transition at this
location. The proposed zone change from R-2 Single Family
Residential to a Planned Office, with the use and design
proposed, is consistent with the Land Use Plan.
City Recognized Neighborhood Action Plan: This area is
covered by the River Mountain Neighborhood Action Plan.
The neighborhood plan does not provide any recommendation
relevant to this application.
W
February 17, 2000
SUBDIVISION
ITEM NO.: 8 (Cont.)
Landscape Issues:
FILE NO.: Z-6808
Unless a co -access is provided along the northern
perimeter, the buffer should not drop below a width of five
feet. A portion of this buffer is only 2 feet wide.
A six foot high opaque screen is required along the
northern, eastern and southern perimeters. This screen may
be a wooden fence with its face side directed outward or
dense evergreen plantings. Credit toward fulfilling this
requirement can be given when preserving existing trees.
The City Beautiful Commission recommends preserving as many
trees as feasible.
G. ANALYSIS:
The applicant submitted a revised site plan and additional
information to staff on February 2, 2000. The revised site
plan shows the sign location and additional right-of-way
dedication as required. The proposed driveway has been
shifted slightly to the south to provide an increased
buffer area along the north property line. The applicant
will use a combination of opaque fencing and dense
evergreen plantings as screening along the north property
line and dense evergreen plantings along the south property
line.
The proposed site plan provides for 12 on-site parking
spaces. The ordinance would typically require 7 spaces for
an office development of this size. Staff supports the
parking plan as proposed.
As noted, the revised site plan shows the required right-
of-way dedication. The applicant is proposing to make in -
lieu contribution for the required street improvements.
Staff feels that the applicant has done a good job in
addressing the outstanding issues as raised by the
Subdivision Committee review. The proposed site plan and
use of the property is very similar to the recently
approved planned development for Steve Pinter Century 21
Realty along the east side of Jerry Drive to the northeast.
The proposed POD should prove to be a very good development
within this area of Transition along the east side of
Taylor Loop Road.
4
February 17, 2000
SUBDIVISION
ITEM NO.: 8 (Cont.) FILE NO.: Z-6808
H. STAFF RECOMMENDATIONS:
Staff recommends approval of the proposed POD rezoning
subject to the following conditions:
1. Compliance with the requirements as noted in paragraphs
D, E and F of this report.
2. The POD will be for general/professional office uses
only.
3. Any site lighting should be low-level and directed away
from adjacent property.
4. The existing trees within the east 245 feet of the
property will be preserved.
5. The ground mounted sign shall be monument type, with a
maximum height of 6 feet and a maximum area of 64 square
feet.
SUBDIVISION COMMITTEE COMMENT: (JANUARY 271 2000)
Terry Burruss and Al Robertson were present, representing the
application. Staff described the POD site plan, noting that
hours of operation and signage details needed to be provided.
Staff noted that the two (2) parking spaces shown on the west
side of the building might have to be eliminated with the
additional right-of-way dedication for Taylor Loop Road. Mr.
Burruss stated that he would like to maintain one (1) space on
the west side of the building.
The Public Works requirements were briefly discussed. Mr.
Burruss noted that the requirements would be complied with. He
stated that he would like to do an in -lieu contribution for the
street improvements to Taylor Loop Road.
The landscape and buffer requirements were briefly discussed.
Bob Brown, Site Plan Review Specialist, noted that the northern
buffer needed to be increased to five (5) feet. Mr. Burruss
noted that the driveway from the street to the front building
line would be shifted to provide a larger buffer. He noted that
the two (2) foot buffer along the north side of the building
could be made up with additional landscaping. He stated that he
would meet with Mr. Brown on this issue.
After the discussion, the POD was forwarded to the full
Commission for resolution.
5
February 17, 2000
SUBDIVISION
ITEM NO.: 8 (Cont.)
FILE NO.: Z-6808
PLANNING COMMISSION ACTION: (FEBRUARY 17, 2000)
Terry Burruss and Al Robertson were present, representing the
application. Staff briefly described the proposed POD, with a
recommendation of approval with conditions.
Chairman Berry asked to hear from the one (1) person present who
opposed the application.
Diana Armstrong addressed the Commission in opposition to the
application. She stated that the proposed development will
adversely effect the value of her property.
There was a general discussion of the Land Use Plan in this
area, specifically the area of Transition.
Jim Lawson, Director of Planning and Development, explained the
Transition designation, noting that single-family, multifamily
and office uses would be appropriate uses in Transition.
There was a motion to approve the application as recommended by
Staff. The motion passed by a vote of 9 ayes, 0 nays and 2
absent.
C