HomeMy WebLinkAboutZ-6748-A Staff AnalysisSeptember 30, 1999
ITEM NO.: 16.1
NAME:
LOCATION:
OWNER/APPLICANT:
FILE NO: Z -6748-A
McCormack - Conditional Use Permit
12001 Kanis Road, southwest corner of Kanis
and Bowman Roads
Direct Jewelry Wholesale/Merlin Seamon
Associates
PROPOSAL: To obtain a conditional use permit to
construct a laundry/dry-clean drop-off
business with a small separate office in the
same building at 12001 Kanis Road on
property currently Zoned R-2, Single Family
Residential. There is an accompanying item
on this agenda, Item 16, to change the
zoning to C-1.
ORDINANCE DESIGN STANDARDS:
1. SITE LOCATION:
This site is located at the southwest corner of the
intersection of Kanis and Bowman Roads.
2. COMPATIBILITY WITH NEIGHBORHOOD:
This site is currently Zoned R-2, Single Family
Residential, but there is an accompanying action on this
agenda, item 16, to rezone the property to C-1,
Neighborhood Commercial. The property to the north across
Kanis is Zoned C-3, and contains a nursery. To the east
across Bowman the zoning is R-2, but contains a non-
conforming liquor store. A mini -storage exists to the west
on property zoned C-3. To the south the adjacent zoning is
R-2, with PDC, Planned Development Commercial, just to the
south of that.
Staff believes the proposed use would be compatible with
the surrounding area.
The Gibralter/Point West/Timber Ridge Neighborhood
Association was notified of the Public Hearing.
September 30, 1999
SUBDIVISION
ITEM NO.: 16.1 (Cont.)
3. ON SITE DRIVES AND PARKING:
FILE NO: Z -6748-A
The proposal includes one driveway from both Kanis and
Bowman. A variance is required for driveway spacing caused
by the small size of the lot.
Parking is based on 1 space per 300 square feet of gross
floor area for commercial, and 1 per 400 sq. ft. for
office. At this site that would result in 8 and 3 spaces
respectively, or 11 spaces total, including 1 handicapped
accessible space. The drive through service would require a
minimum of 3 spaces. Parking requirements would be met as
proposed.
4. SCREENING AND BUFFERS:
The revised proposed site plan meets ordinance
requirements.
5. PUBLIC WORKS COMMENTS:
1. Kanis Road and Bowman Road are listed on the Master
Street Plan as a minor arterial. A dedication of right-
of-way to 45 feet from centerline is required.
(Additional 10 feet of right-of-way on Kanis Road is
required for turn lane.)
2. A 20 feet radial dedication of right-of-way is required
at the corner of Kanis and Bowman.
3. Provide design of streets conforming to "MSP" (Master
Street Plan). Construct one-half street improvements to
these streets including 5 -foot sidewalks with planned
development.
4. Plans of all work in right-of-way shall be submitted for
approval prior to start of work.
5. A Sketch Grading and Drainage Plan per Sec. 29-186(e) is
required.
6. Driveway on Kanis Road must be right in and right out
only. Construct island and 2 feet wide median to prevent
left turns.
7. Driveway on Bowman Road is too close to property line.
Relocate 25 feet from property line.
2
September 30, 1999
SUBDIVISION
ITEM NO.: 16.1 (Cont.) FILE NO: Z -6748-A
6. UTILITY AND FIRE DEPT. COMMENTS:
Water: Contact the Water Works if additional water service
is needed.
Wastewater: Sewer available, not adversely affected.
Southwestern Bell: No comments received.
ARKLA: Approved as submitted.
Entergy: No comments received.
Fire Department: Approved as submitted.
CATA: No Comments received.
7. STAFF ANALYSIS:
The applicant is requesting a conditional use permit to
construct a 2,500 square foot laundry/dry-clean drop-off
business with a 1,356 square foot separate office in the
same building on the southwest corner of Kanis and Bowman.
The property is currently Zoned R-2, Single Family
Residential, but on this same agenda is a request to rezone
it to C-1, which would allow for this use under a
conditional use permit.
Access would be provided by single driveways from both
Kanis and Bowman Roads. The parking proposed meets
ordinance requirement.
One of the setbacks proposed, however, does not meet
standards and would require a variance. The applicant is
asking for a 52 foot front setback, and a 8 foot rear
setback versus 25 feet required in both cases. The extra
space in the front would accommodate the parking area.
However, this is a corner lot and so if an exterior side
yard of 25 feet is provided, then the rear can be reduced
to 8 feet. The side yard adjacent to Kanis is only 15 feet
due to the dedication of additional right-of-way for a turn
lane on Kanis. The side setback to the south is 10 feet
versus the required 8 foot minimum. This is the side
adjacent to residential zoning.
3
September 30, 1999
SUBDIVISION
ITEM NO.: 16.1 (Cont.) FILE NO: Z -6748-A
While this site layout would be a rather tight fit, Staff
believes it is a reasonable use of this property, and
acknowledges that the applicant has worked closely with
Staff to make it work within ordinance requirements.
8. STAFF RECOMMENDATION:
Staff recommends approval of the conditional use permit
subject to compliance with the following conditions:
a. Comply with the City's Landscape and Buffer Ordinances.
b. Comply with Public Works Comments.
Staff also recommends approval of the variances for
driveway spacing and reduced setback on the north side of
the property.
The applicant has requested a 5 year deferral for street
improvements. Public Works recommends an in -lieu
contribution for half of the applicant's cost of current
street improvements and supports deferral of the remaining
street improvement cost. They would also support an in -lieu
payment of 15% of the total development cost now.
SUBDIVISION COMMITTEE COMMENT:
(SEPTEMBER 9, 1999)
Merlin Seamon and Mr. McCormack were present representing the
application. Staff gave a brief description of the proposal.
Public Works reviewed their comments and clarified for the
applicant what was required and why, plus explained the various
options for meeting the obligations.
The applicant provided the following additional information: the
construction style would be Dryvit and glass exterior finishing
with a peaked standing seam roof, and they would meet C-1 sign
standards.
There being no further issues, the Committee accepted the
proposal and forwarded the item to the full Commission for final
action.
4
September 30, 1999
SUBDIVISION
ITEM NO.: 16.1 (Cont.) FILE NO: Z -6748-A
PLANNING COMMISSION ACTION:
(SEPTEMBER 30, 1999)
Merlin Seamon was present representing the application. There
were no registered objectors present. Staff presented the item
with a recommendation for approval subject to compliance with
the conditions listed under "Staff Recommendation."
The item was placed on the Consent Agenda and approved as
recommended by Staff. The vote was 11 ayes, 0 nays, and 0 absent.
5