HomeMy WebLinkAboutZ-6721 Staff AnalysisFILE NO.: Z-6721
NAME: Lands - Short -Form PCD
LOCATION: North side of Colonel Glenn Road, at Rocky Lane
DEVELOPER: ENGINEER:
Sammie and Susie Lands White-Daters and Associates
17201 Colonel Glenn Road 401 S. Victory Street
Little Rock, AR 72210 Little Rock, AR 72201
AREA: 2.7 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0
ZONING: R-2 ALLOWED USES:
PROPOSED USE:
VARIANCES/WAIVERS REQUESTED:
Single-family residential,
nonconforming convenience store
with gas pumps
Convenience store with gas
pumps, car wash, mini -warehouses
1. Deferral of street improvements to Colonel Glenn Road.
2. Variance from the ordinance requirements for driveway spacing.
3. Deferral of right-of-way dedication under existing gas pumps
until Phase 2.
BACKGROUND:
The property along the north side of Colonel Glenn Road at Rocky
Lane is zoned R-2 and has a nonconforming commercial status.
There is an existing convenience store with gas pumps on the
site.
A. PROPOSAL/REQUEST:
The applicant proposes to rezone the property from R-2 to
PCD to allow for a complete redevelopment of the site. The
FILE NO.: Z-6721 (Cont.)
proposed redevelopment includes the following as noted on
the attached site plan:
1. A new 2,400 square foot convenience store building.
2. Relocation of existing gas pumps.
3. An automated and self -serve car wash building with vacuum
stations.
4. Two (2) mini -warehouse buildings.
5. Associated drives and parking areas.
The applicant has noted that the building heights will not
exceed 25 feet. The applicant has also noted that the
hours of operation will be from 6:00 a.m. to 10:00 p.m.,
daily.
B. EXISTING CONDITIONS:
There is an existing convenience store with gas and diesel
pumps on the site, as noted on the attached site plan. The
property to the north is vacant and wooded. There is another
convenience store with gas pumps to the southwest at the
corner of Colonel Glenn Road and Rocky Lane. Single-family
residences on larger lots are located to the south across
Colonel Glenn Road and to the east along Colonel Glenn.
There is a beauty shop, a pet grooming/boarding business and
single-family residences to the west along Colonel Glenn
Road.
C. NEIGHBORHOOD CONMNTS:
As of this writing, staff has received no comment from the
neighborhood. There was no established neighborhood
association to notify.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1.Dedication of right-of-way to 55 feet on Colonel Glenn Road.
Clearance of soils from APCE required prior to dedication.
2. Driveways must conform to #18,031 (spacing and width).
3. Construct half -street improvements as per Master Street Plan.
4. Existing topographic information at maximum five-foot contour
interval 10 feet base flood elevation is required.
5.A Sketch Grading and Drainage Plan per Sec. 29-186(e) is
required.
6. A Grading Permit per Secs. 29-186(c)(d) is required.
2
FILE NO.: Z-6721 (Cont.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Outside service boundary, no comment.
AP&L: No Comment received.
Arkla: No Comment.
Southwestern Bell: No Comment received.
Water: Contact the Water Works if service is needed. If
this property does not have existing water service,
execution of a pre -annexation agreement will be required.
Installation of an outside city fire hydrant is
recommended.
Fire Department: Outside city limits. If property is ever
annexed, private fire hydrants may be required.
County Planning:
1. Remove gas tanks from right-of-way.
2. Provide proper water control for car wash to prevent
water from flowing onto Colonel Glenn Road.
3. Septic system must be approved by the Pulaski County
Health Department.
CATA: Not currently in CATA service area. No comment.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division:
This request is in the Ellis Mountain Planning District.
The use of a convenience store and other uses are
consistent with the existing Business Node and the overall
size of the parcel is consistent. Concerns are buffers on
all three sides to Single Family areas; Signage locations
and size; Topography differences and cuts into the
hillside.
City Recognized Neighborhood Action Plan: There is not a
neighborhood plan for this area at this time.
Landsca a Issues:
The land use and street buffers now conform to ordinance
standards.
A six foot high opaque screen, either a wooden fence with
its face side directed outward or dense evergreen plantings
3
FILE NO.: Z-6721 (Cont.
will be required adjacent to residential properties to the
north, east and west.
A small amount of building landscaping will be required
between the public parking areas and building they serve.
At least 605 of the land use buffers must remain in its
natural state.
The City Beautiful Commission recommends preserving as many
trees as are feasible. Extra credit toward fulfilling
Landscape Ordinance requirements can be given when
preserving trees of 6 inch caliper or larger.
Prior to a building permit being issued, a detailed
landscape plan must be approved by the Plans Review
Specialist.
G. ANALYSIS:
There are several design related issues associated with the
proposed site plan which need to be addressed and resolved
by the applicant. The issues which need to be resolved
include, but are not limited to: building locations,
driveway locations, landscape and buffer areas, vehicular
circulation and phasing plan.
Given the amount of site plan redesign work that needs to
be done, staff suggested to the applicant at the
Subdivision Committee meeting that this item be deferred.
A deferral will allow staff and the Subdivision Committee
adequate time to review a revised plan. The applicant
submitted a letter to staff on August 4, 1999 requesting
deferral of this item to the September 30, 1999 agenda.
H. STAFF RECOMMENDATIONS:
Staff recommends approval of the requested deferral of this
item to the September 30, 1999 Planning Commission agenda.
SUBDIVISION COMMITTEE COMMENT: (JULY 29, 1999)
Joe White was present, representing the application. Staff gave
a brief description of the PDC site plan, noting a number of
concerns with the proposed site design. Staff noted that the
site plan should be totally redesigned to provide for improved
vehicular circulation and use of the property. Staff suggested
4
FILE NO.: Z-6721 (Cont.)
that the application be deferred to allow adequate time to
review a revised site plan and bring the revised site plan to
the Subdivision Committee. Mr. White agreed with the deferral
as suggested by staff.
PLANNING COMMISSION ACTION: (AUGUST 19, 1999)
Staff informed the Commission that the applicant submitted a
letter to staff on August 4, 1999 requesting that this item be
deferred to the September 30, 1999 agenda. Staff supported the
deferral request.
The Chairman placed the item before the Commission for inclusion
within the Consent Agenda for deferral to September 30, 1999. A
motion to that effect was made. The motion passed by a vote of
6 ayes, 0 nays and 5 absent.
STAFF UPDATE:
The applicant submitted a revised site plan to staff on
September 14, 1999. The revised plan addresses the.concerns as
raised by staff and the Subdivision Committee. A six foot high
screening fence has been shown along the north, east and west
property lines, the proposed phase lines have been shown on the
plan and the new sign location has been shown. The ground sign
will need to be at least five (5) feet back from the front
property line (after right-of-way dedication). The applicant
notes that the existing sign will remain within the right-of-way
for Colonel Glenn Road until it is relocated with Phase 2
construction.
The revised plan also shows increased buffers as required. The
land use buffers along the east and west property lines as well
as the street side buffer conform to the full buffer width
requirements. The north land use buffer has been increased to
25 feet, 9.5 feet beyond the full buffer requirement of 15.5
feet.
The relocated gas pumps have been turned to allow better
vehicular circulation within the area in front of the new
convenience store building. The northernmost mini -warehouse
building has been redesigned to allow access only from the south
side, as recommended by staff. There will be no doors or
driveway on the north side of this building.
�1
FILE NO.: Z-6721 (Cont.
The ordinance would typically require 12 parking spaces for a
convenience store of this size. There are 20 parking spaces on
the proposed site plan which are located around the proposed
building. There are also 12 truck parking spaces located along
the west property line. Staff is comfortable with the parking
design as proposed.
The following phases are noted on the site plan:
Phase 1 - construction of car wash building
Phase 2 - construction of 2,400 convenience store building,
removal of existing building, relocation of gas pumps and
canopy, additional parking areas
Phase 3 - construction of two (2) mini -warehouse buildings
The applicant is requesting deferral of street improvements,
including driveway construction, to Colonel Glenn Road for five
(5) years, until adjacent development or until a public project,
whichever occurs first. The applicant noted at the Subdivision
Committee meeting that the right-of-way for Colonel Glenn Road
would be dedicated with the exception of the right-of-way under
the existing gas pumps, which is requested to be deferred until
phase 2 construction, at which time the gas pumps will be
relocated. Public Works recommends approval of the deferrals as
requested.
The applicant is also requesting a variance from the ordinance
requirement for minimum driveway spacing. The ordinance
requires that driveways along arterial streets be separated by
at least 300 feet and be spaced at least 150 feet from property
lines. A lot requires a minimum frontage of 750 feet for two
(2) drives.
The two proposed drives are separated by approximately 205 feet.
The easternmost drive is located 94 feet from the east property
line, with the west drive being approximately 110 feet from the
west property line. All measurements are from centerline of
drives. The property has 414 feet of street frontage. Public
Works recommends approval of this variance request, as two (2)
drives would provide the best circulation for this convenience
store with gas pumps.
Otherwise, to staff's knowledge, there are no outstanding issues
associated with the PCD site plan. Staff is satisfied with the
revised site plan and feels that the revised plan adequately
6
FILE NO.: Z-6721 (Cont.
addresses the issues raised by staff and that this site
development plan will have no adverse effect on the general
area.
SUBDIVISION COMMITTEE COMMENT:
Joe White was present, representing the
a brief description of the revised site
screening fences and phase lines needed
Staff noted an overall satisfaction wit
h
(SEPTEMBER 9, 1999)
application. Staff gave
plan, noting that
to be shown on the plan.
the revised plan.
Staff also noted that the existing ground -mounted sign would
need to be relocated out of the right-of-way and shown on the
site plan. Mr. White stated that the sign would be left in the
right-of-way until Phase 2 construction at which time it would
be relocated. Bob Turner, of Public Works indicated support of
this request.
The deferrals and variance associated with this rezoning were
briefly discussed. Mr. White noted that the right-of-way for
Colonel Glenn Road could be dedicated except for that portion
under the existing gas pumps. He noted that this portion of
right-of-way would need to be deferred until Phase 2.
The proposed driveway locations were briefly discussed. Mr.
White noted that the request for deferral of street improvements
would include new driveway construction.
After the discussion, the Committee forwarded the proposed PCD
zoning to the full Commission for final action.
STAFF RECOMMENDATIONS:
Staff recommends approval of the PCD zoning subject to the
following conditions:
1. Compliance with the requirements as noted in paragraphs D,
and F of this report.
2. Staff recommends approval of the deferral of street
improvements, including driveway construction, to Colonel
Glenn Road for five (5) years, until adjacent development
until a public project, whichever occurs first.
3. Staff recommends approval of the deferral of right-of-way
dedication for that portion under the existing gas pumps
until Phase 2 construction.
7
E
or
FILE NO.: Z-6721 (Cont.)
4. Staff recommends approval of the requested variance for
driveway spacing.
5. There are to be no doors, drives or access on the north side
of the northernmost mini -warehouse building.
6. Any site lighting shall be low-level and directed away from
adjacent property.
PLANNING COMMISSION ACTION: (SEPTEMBER 30, 1999)
The staff presented a positive recommendation on this
application, as there were no further issues for resolution.
There were no objectors to this matter.
The Chairman placed the item before the commission for inclusion
within the Consent Agenda for approval as recommended by staff.
A motion to that effect was made. The motion passed by a vote
of 11 ayes and 0 nays.
8
September 30, 1999
ITEM NO.: C
NAME: Lands - Short -Form PCD
FILE NO.: Z-6721
LOCATION: North side of Colonel Glenn Road, at Rocky Lane
DEVELOPER=
ENGINEER:
Sammie and Susie Lands White-Daters and Associates
17201 Colonel Glenn Road 401 S. Victory Street
Little Rock, AR 72210 Little Rock, AR 72201
AREA: 2.7 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0
ZONING: R-2 ALLOWED USES:
Single-family residential,
nonconforming convenience store
with gas pumps
PROPOSED USE: Convenience store with gas
pumps, car wash, mini -warehouses
VARIANCES/WAIVERS REQUESTED:
1. Deferral of street improvements to Colonel Glenn Road.
2. Variance from the ordinance requirements for driveway spacing.
3.Deferral of right-of-way dedication under existing gas pumps
until Phase 2.
BACKGROUND:
The property along the north side of Colonel Glenn Road at Rocky
Lane is zoned R-2 and has a nonconforming commercial status.
There is an existing convenience store with gas pumps on the
site.
A. PROPOSAL/REQUEST:
The applicant proposes to rezone the property from R-2 to
PCD to allow for a complete redevelopment of the site. The
September 30, 1999
SUBDIVISION
ITEM NO.: C (Cont.) FILE NO.: Z-6721
proposed redevelopment includes the following as noted on
the attached site plan:
1. A new 2,400 square foot convenience store building.
2. Relocation of existing gas pumps.
3. An automated and self -serve: car wash building with vacuum
stations.
4. Two (2) mini -warehouse buildings.
5. Associated drives and parking areas.
The applicant has noted that the building heights will not
exceed 25 feet. The applicant has also noted that the
hours of operation will be from 6:00 a.m. to 10:00 p.m.,
daily.
B. EXISTING CONDITIONS:
There is an existing convenience store with gas and diesel
pumps on the site, as noted on the attached site plan. The
property to the north is vacant and wooded. There is another
convenience store with gas pumps to the southwest at the
corner of Colonel Glenn Road and Rocky Lane. Single-family
residences on larger lots are located to the south across
Colonel Glenn Road and to the east along Colonel Glenn.
There is a beauty shop, a pet grooming/boarding business and
single-family residences to the west along Colonel Glenn
Road.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received no comment from the
neighborhood. There was no established neighborhood
association to notify.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Dedication of right-of-way to 55 feet on Colonel Glenn
Road. Clearance of soils from APCE required prior to
dedication.
2. Driveways must conform to #18,031 (spacing and width).
3. Construct half -street improvements as per Master Street
Plan.
4. Existing topographic information at maximum five-foot
contour interval 10 feet base flood elevation is
required.
2
September 30, 1999
SUBDIVISION
ITEM NO.: C (Cont.) FILE NO.: Z-6721
5. A Sketch Grading and Drainage Plan per Sec. 29-186(e) is
required.
6.A Grading Permit per Secs. 29-186(c)(d) is required.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Outside service boundary, no comment.
AP&L: No Comment received.
Arkla: No Comment.
Southwestern Bell: No Comment received.
Water: Contact the Water Works if service is needed. If
this property does not have existing water service,
execution of a pre -annexation agreement will be required.
Installation of an outside city fire hydrant is
recommended.
Fire Department: Outside city limits. If property is ever
annexed, private fire hydrants may be required.
County Plannin :
1. Remove gas tanks from right-of-way.
2.Provide proper water control for car wash to prevent
water from flowing onto Colonel Glenn Road.
3. Septic system must be approved by the Pulaski County
Health Department.
CATA: Not currently in CATA service area. No comment.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division:
This request is in the Ellis Mountain Planning District.
The use of a convenience store and other uses are
consistent with the existing Business Node and the overall
size of the parcel is consistent. Concerns are buffers on
all three sides to Single Family areas; Signage locations
and size; Topography differences and cuts into the
hillside.
City Recognized Neighborhood Action Plan: There is not a
neighborhood plan for this area at this time.
3
September 30, 1999
SUBDIVISION
ITEM NO.• C (Cont.) FILE NO.: Z-6721
Landscape Issues:
The land use and street buffers now conform to ordinance
standards.
A six foot high opaque screen, either a wooden fence with
its face side directed outward or dense evergreen plantings
will be required adjacent to residential properties to the
north, east and west.
A small amount of building landscaping will be required
between the public parking areas and building they serve.
At least 60% of the land use buffers must remain in its
natural state.
The City Beautiful Commission recommends preserving as many
trees as are feasible. Extra credit toward fulfilling
Landscape Ordinance requirements can be given when
preserving trees of 6 inch caliper or larger.
Prior to a building permit being issued, a detailed
landscape plan must be approved by the Plans Review
Specialist.
G. ANALYSIS:
There are several design related issues associated with the
proposed site plan which need to be addressed and resolved
by the applicant. The issues which need to be resolved
include, but are not limited to: building locations,
driveway locations, landscape and buffer areas, vehicular
circulation and phasing plan.
Given the amount of site plan redesign work that needs to
be done, staff suggested to the applicant at the
Subdivision Committee meeting that this item be deferred.
A deferral will allow staff and the Subdivision Committee
adequate time to review a revised plan. The applicant
submitted a letter to staff on August 4, 1999 requesting
deferral of this item to the September 30, 1999 agenda.
4
September 30, 1999
SUBDIVISION
ITEM NO.: C (Cont.) FILE NO.: Z-6721
H. STAFF RECObMENDATIONS :
Staff recommends approval of the requested deferral of this
item to the September 30, 1999 Planning Commission agenda.
SUBDIVISION COMMITTEE COMMENT: (JULY 29, 1999)
Joe White was present, representing the application. Staff gave
a brief description of the PDC site plan, noting a number of
concerns with the proposed site design. Staff noted that the
site plan should be totally redesigned to provide for improved
vehicular circulation and use of the property. Staff suggested
that the application be deferred to allow adequate time to
review a revised site plan and bring the revised site plan to
the Subdivision Committee. Mr. White agreed with the deferral
as suggested by staff.
PLANNING COMMISSION ACTION:
(AUGUST 19, 1999)
Staff informed the Commission that the applicant submitted a
letter to staff on August 4, 1999 requesting that this item be
deferred to the September 30, 1999 agenda. Staff supported the
deferral request.
The Chairman placed the item before the Commission for inclusion
within the Consent Agenda for deferral to September 30, 1999. A
motion to that effect was made. The motion passed by a vote of
6 ayes, 0 nays and 5 absent.
STAFF UPDATE:
The applicant submitted a revised site plan to staff on
September 14, 1999. The revised plan addresses the concerns as
raised by staff and the Subdivision Committee. A six foot high
screening fence has been shown along the north, east and west
property lines, the proposed phase lines have been shown on the
plan and the new sign location has been shown. The ground sign
will need to be at least five (5) feet back from the front
property line (after right-of-way dedication). The applicant
notes that the existing sign will remain within the right-of-way
for Colonel Glenn Road until it is relocated with Phase 2
construction.
5
September 30, 1999
SUBDIVISION
ITEM NO.: C (Cont.) FILE NO.: Z-6721
The revised plan also shows increased buffers as required. The
land use buffers along the east and west property lines as well
as the street side buffer conform to the full buffer width
requirements. The north land use buffer has been increased to
25 feet, 9.5 feet beyond the full buffer requirement of 15.5
feet.
The relocated gas pumps have been turned to allow better
vehicular circulation within the area in front of the new
convenience store building. The northernmost mini -warehouse
building has been redesigned to allow access only from the south
side, as recommended by staff. There will be no doors or
driveway on the north side of this building.
The ordinance would typically require 12 parking spaces for a
convenience store of this size. There are 20 parking spaces on
the proposed site plan which are located around the proposed
building. There are also 12 truck parking spaces located along
the west property line. Staff is comfortable with the parking
design as proposed.
The following phases are noted on the site plan:
Phase 1 - construction of car wash building
Phase 2 - construction of 2,400 convenience store building,
removal of existing building, relocation of gas pumps and
canopy, additional parking areas
Phase 3 - construction of two (2) mini -warehouse buildings
The applicant is requesting deferral of street improvements,
including driveway construction, to Colonel Glenn Road for five
(5) years, until adjacent development or until a public project,
whichever occurs first. The applicant noted at the Subdivision
Committee meeting that the right-of-way for Colonel Glenn Road
would be dedicated with the exception of the right-of-way under
the existing gas pumps, which is requested to be deferred until
phase 2 construction, at which time the gas pumps will be
relocated. Public Works recommends approval of the deferrals as
requested.
The applicant is also requesting a variance from the ordinance
requirement for minimum driveway spacing. The ordinance
requires that driveways along arterial streets be separated by
6
September 30, 1999
SUBDIVISION
ITEM NO.: C (Cont.) FILE NO.: Z-6721
at least 300 feet and be spaced at least 150 feet from property
lines. A lot requires a minimum frontage of 750 feet for two
(2) drives.
The two proposed drives are separated by approximately 205 feet.
The easternmost drive is located 94 feet from the east property
line, with the west drive being approximately 110 feet from the
west property line. All measurements are from centerline of
drives. The property has 414 feet of street frontage. Public
Works recommends approval of this variance request, as two (2)
drives would provide the best circulation for this convenience
store with gas pumps.
Otherwise, to staff's knowledge, there are no outstanding issues
associated with the PCD site plan. Staff is satisfied with the
revised site plan and feels that the revised plan adequately
addresses the issues raised by staff and that this site
development plan will have no adverse effect on the general
area.
SUBDIVISION COMMITTEE COMMENT:
Joe White was present, representing the
a brief description of the revised site
screening fences and phase lines needed
Staff noted an overall satisfaction wit
h
(SEPTEMBER 9, 1999)
application. Staff gave
plan, noting that
to be shown on the plan.
the revised plan.
Staff also noted that the existing ground -mounted sign would
need to be relocated out of the right-of-way and shown on the
site plan. Mr. White stated that the sign would be left in the
right-of-way until Phase 2 construction at which time it would
be relocated. Bob Turner, of Public Works indicated support of
this request.
The deferrals and variance associated with this rezoning were
briefly discussed. Mr. White noted that the right-of-way for
Colonel Glenn Road could be dedicated except for that portion
under the existing gas pumps. He noted that this portion of
right-of-way would need to be deferred until Phase 2.
The proposed driveway locations were briefly discussed. Mr.
White noted that the request for deferral of street improvements
would include new driveway construction.
7
September 30, 1999
SUBDIVISION
ITEM NO.: C (Cont.)
FILE NO.: Z-6721
After the discussion, the Committee forwarded the proposed PCD
zoning to the full Commission for final action.
STAFF RECOMMENDATIONS:
Staff recommends approval of the PCD zoning subject to the
following conditions:
1. Compliance with the requirements as noted in paragraphs D, E
and F of this report.
2. Staff recommends approval of the deferral of street
improvements, including driveway construction, to Colonel
Glenn Road for five (5) years, until adjacent development or
until a public project, whichever occurs first.
3. Staff recommends approval of the deferral of right-of-way
dedication for that portion under the existing gas pumps
until Phase 2 construction.
4. Staff recommends approval of the requested variance for
driveway spacing.
5_ There are to be no doors, drives or access on the north side
of the northernmost mini -warehouse building.
6. Any site lighting shall be low-level and directed away from
adjacent property.
PLANNING COMMISSION ACTION: (SEPTEMBER 30, 1999)
The staff presented a positive recommendation on this
application, as there were no further issues for resolution.
There were no objectors to this matter.
The Chairman placed the item before the Commission for inclusion
within the Consent Agenda for approval as recommended by staff.
A motion to that effect was made. The motion passed by a vote
of 11 ayes and 0 nays.
8