Loading...
HomeMy WebLinkAboutZ-6661-A Map 8103�Q I I O O 4 4 -UWEB STiFGENEf2 - t,foT .SH OU/�I POT; ITEM 10 _63/I cps END VIEW co "/I Ic'� r4TEFi NOTES: I. ALL STRUCTURAL- STEEL WORK IS TO BE PER THE BEST PRACTICE OF THE,,MANUAL OF STEEL CONSTRUCTION, LATEST EDITION', AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISE). 2. ALL STRUCTURAL STEEL IS TO BE ASTM A36. FULL LENGTH MEMBERS, NO SPLICES ALLOWED EXCEPT AS DETAILED. 3. ALL BOLTS ARE TO BE 3/4" DIAMETER A 325X. 4. ALL WELDING IS TO BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS) SPECIFICATIONS USING E70XX EL.ETRODE. ALL WELDERS SHALL BE CURRENTLY AWS CERTIFIED TO PERFORM WELDS BEING MADE. PAINT SPECIFICATIONS: I. SURFACE PREPARATION: WHITE METAL BLAST SSPC-SPS ORNACEI. 2. PRR,4F COAT: ARMOR SEAL 33 EPDXY, PRIMER BY SHERWIN WILLIAMS. 3. TOPCOAT: 2 COATS SHERWINwa LIAMS ARMOR SEAL IOOOHS BY SHERWIN WILLIAMS- ALL WORK AND MATERIALS IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. el TOWER SUPPORT DETAIL PLAN �4! L_ PLAN J* RRCIIS'I'ERED PROFESSR)NAI. HOPE ENGINEERS, Inc. 406 W. South Street Benton, Arkansas 72015 AGI"� (501) 315-0786 FAX (501) 315-0'700 ....._.. i DATE: 9-8-2000 el TOWER SUPPORT DETAIL PLAN �4! L_ PLAN J* RRCIIS'I'ERED PROFESSR)NAI. Y S y�3 d 6^°S 54zl C11 'YS N4 8 r r s ROOF OF BUILDING NO. 2, RIVERCLIFF APARTMENTS SCALE 1",= 10 EAST ELEVATION NORTH ELEVATION NOTES: 1a)TESSCO 25G TOWER 0 TESSCO EB2525G EAVE BRACKET (2 Req'd ) O3 TESSCO BPC25G BASE PLATE OMC 6X 12 HRS CHANNEL O 12" X 1/4" X 1'6" HRS PLATE �2 1/2" X 2 1/2" X 3/16" NRS ANGLE O6" X 6" X 3/6"X 1'4" HRS ANGLE 11/16" DRILL 4 HOLES @ 2" CTRS. Fasten to existing Roof Beam by welding or with 2 @ 5/8" structural bolts. ( 2 REQUIRED ) O EXISTING STEEL ROOF BEAM O9 BASE PLATE. 10" X 1/4" X 1'3" HRS PLATE WITH 11/16" X 1- 9/16" SLOTTED HOLE. (2 REQ'D ) 10 5/8" GALVANIZED ANCHOR BOLT SET IN CONCRETE WITH EPDXY PER MFG. RECOMMENDATIONS 11 EXISTING CONCRETE ROOF BEAM 12 6" X 10-3/4" X 3/8" HRS PLATE WEBB STIFFENER WELD ALL AROUND. NOTE: ALL BOLTS TO BE 5/8" GALVANIZED STEEL STRUCTURAL BOLTS. HOPE ENGINEERS, Inc. 406 W. South Street Benton, Arkansas 72015 AGI"� (501) 315-0786 FAX (501) 315-0'700 ....._.. Y}i. 1" DATE: 9-8-2000 C.A.D. BY: ,w DRAWINGNUMBER: SHEET: 00-733 1 of 1 - �— Y S y�3 d 6^°S 54zl C11 'YS N4 8 r r s ROOF OF BUILDING NO. 2, RIVERCLIFF APARTMENTS SCALE 1",= 10 EAST ELEVATION NORTH ELEVATION NOTES: 1a)TESSCO 25G TOWER 0 TESSCO EB2525G EAVE BRACKET (2 Req'd ) O3 TESSCO BPC25G BASE PLATE OMC 6X 12 HRS CHANNEL O 12" X 1/4" X 1'6" HRS PLATE �2 1/2" X 2 1/2" X 3/16" NRS ANGLE O6" X 6" X 3/6"X 1'4" HRS ANGLE 11/16" DRILL 4 HOLES @ 2" CTRS. Fasten to existing Roof Beam by welding or with 2 @ 5/8" structural bolts. ( 2 REQUIRED ) O EXISTING STEEL ROOF BEAM O9 BASE PLATE. 10" X 1/4" X 1'3" HRS PLATE WITH 11/16" X 1- 9/16" SLOTTED HOLE. (2 REQ'D ) 10 5/8" GALVANIZED ANCHOR BOLT SET IN CONCRETE WITH EPDXY PER MFG. RECOMMENDATIONS 11 EXISTING CONCRETE ROOF BEAM 12 6" X 10-3/4" X 3/8" HRS PLATE WEBB STIFFENER WELD ALL AROUND. NOTE: ALL BOLTS TO BE 5/8" GALVANIZED STEEL STRUCTURAL BOLTS. HOPE ENGINEERS, Inc. 406 W. South Street Benton, Arkansas 72015 AGI"� (501) 315-0786 FAX (501) 315-0'700 FOR USE AND BENEFIT OF, Cricket Communications, Inc. ROOF MOUNT TOWER SUPPORTS LIT 040C RIVER FRONT DATE: 9-8-2000 C.A.D. BY: ,w DRAWINGNUMBER: SHEET: 00-733 1 of 1 - �— REVISED: CHECKED BY: 1 /1 e -- SCALE: Noted p� 6 t M. 3 j qp �/yip e y pq. yqry� F � EUl yy y ' F 1 Y l nr t r r x` qq 1 1 r a ._,.._ .., t b s � Y S y�3 d 6^°S 54zl C11 'YS N4 8 r r s ROOF OF BUILDING NO. 2, RIVERCLIFF APARTMENTS SCALE 1",= 10 EAST ELEVATION NORTH ELEVATION NOTES: 1a)TESSCO 25G TOWER 0 TESSCO EB2525G EAVE BRACKET (2 Req'd ) O3 TESSCO BPC25G BASE PLATE OMC 6X 12 HRS CHANNEL O 12" X 1/4" X 1'6" HRS PLATE �2 1/2" X 2 1/2" X 3/16" NRS ANGLE O6" X 6" X 3/6"X 1'4" HRS ANGLE 11/16" DRILL 4 HOLES @ 2" CTRS. Fasten to existing Roof Beam by welding or with 2 @ 5/8" structural bolts. ( 2 REQUIRED ) O EXISTING STEEL ROOF BEAM O9 BASE PLATE. 10" X 1/4" X 1'3" HRS PLATE WITH 11/16" X 1- 9/16" SLOTTED HOLE. (2 REQ'D ) 10 5/8" GALVANIZED ANCHOR BOLT SET IN CONCRETE WITH EPDXY PER MFG. RECOMMENDATIONS 11 EXISTING CONCRETE ROOF BEAM 12 6" X 10-3/4" X 3/8" HRS PLATE WEBB STIFFENER WELD ALL AROUND. NOTE: ALL BOLTS TO BE 5/8" GALVANIZED STEEL STRUCTURAL BOLTS. HOPE ENGINEERS, Inc. 406 W. South Street Benton, Arkansas 72015 AGI"� (501) 315-0786 FAX (501) 315-0'700 FOR USE AND BENEFIT OF, Cricket Communications, Inc. ROOF MOUNT TOWER SUPPORTS LIT 040C RIVER FRONT DATE: 9-8-2000 C.A.D. BY: ,w DRAWINGNUMBER: SHEET: 00-733 1 of 1 - �— REVISED: CHECKED BY: 1 /1 e -- SCALE: Noted