HomeMy WebLinkAboutZ-6661 Map 5BUILDING ROOF (N) EQUIPMENT IN ROOM BELOW ON 5th FLOOR F I EQUIPMENT ROOM.\ ON 5th FLOOR F— --I LJ L (N) DISCONNECT OUTSIDE THE BUILDING AT GROUND LEVEL (N) 5" X 18" FLASHING FROM ROOF PARAPET TO 5th FLOOR WINDOW AND TO GROUND LEVEL FOR UTILITIES (TYPE TO BE SIMILAR TO (E) FLASHING) (N) POWER METER OUTSIDE THE BUILDING AT GROUND LEVEL L(E) POWER METER W/DISCONNECT OUTSIDE THE BUILDING AT GROUND LEVEL (E) TELCO BOX OUTSIDE THE BUILDING AT GROUND LEVEL (N) COAX CABLES —' ON SLEEPER C S�C�OR2$0 P C-2 4'-8" 7'-1" r(E) ROOF A c� C-1 'r) CHIMNEY (E) ANTENNA (TYP OF 4) (E) PENTHOUSE (E) 4"O PIPE ROOF PLAN SCALE: 3/16" = l'-0" EVAPORATOR 4'-4!' 5'- 7" 1 00 00 -IIB-- 2 A-1 SECTOR ANT.TYPE COAX SIZE RAD CENTER AZIMUTH EST. CAB. LENGTH RX/TX DOWN TILT DEGREES COLOR CODE JUMPER SIZE JUMPER LENGTH Al DB 978H65T2—M 1 1/4" TBD 10' 100'-0" RX 0° RW 1/2"0 6'-0" A2 DB 978H65T2—M 1 1 /4" TBD 1 C' '00'-0" TX 0° RRY 1/2"0 6'-0" B1 DB 978H65T2—M 7/8" TBD 130° 90'-0" RX 0° BW 1/2"0 6'-0" B2 DB 978H65T2—M 7/8" TBD 130' 90'—O" TX 00 BBY 1/2"0 6'-0" Cl DB 978H65T2—M 7/8" TBD 280' 60'-0" RX 0° GW 1/2"0 6'-0" C2 DB 978H65T2—M 7/8" TBD 280° 60'-0" TX 0° GGY 1/2"4 6'-0" (E) DOUBLE PIPE HOLDER FOR 2 4"0 PIPES (TYP OF 2) (E) 4!'0 PIPE (E) PIPE HOLDER FOR 4!'0 PIPE (TYP OF 4) (E) ROOF PENETRATION FOR 4" O PIPE SECTOR 8 AZ = 130° (N) COAX CABLES ON SLEEPER A-2 —3" ---(N) MICROFLECT FRAME MODEL # 99541 WITH 2 ANTENNAS (TYP OF 3) (E) 3/4!'0 PIPE AND ROOF PENETRATION (E) CABLES (E) ROOF PENETRATION FOR 2-4" O PIPE ROOF PENETRATION FOR CABLES NOTE: NORTH TO BE VERIFIED EQUIPMENT LAYOUT 2 A-1 SOUTH SHACKLEFORD SUITE 600 LITTLE ROCK, AR 72211 OFFICE- (501) 312-2455 x242 & GEM ENGINEERING COMPANY 10970 Stancliff Houston, Texas 77099-4206 Phone(281)561-9225 Fax 281 561-9399 71 PROJECT NOR LTR01OA DRAWN BY1 JC CHECKED BY- TA/HM SUBMITTALS DATE DESCRIPTION REV. 5-06-98 CONSTRUCTION REVIEW 5-08-98 PERMIT SCALE - 0 1/2 1 2 111 mill I I GRAPHIC SCALE IN INCHES LTRO10A RIVERCLIFF 2000 MAGNOLIA AVE. LITTLE ROCK, AR 72202 SHEET TITLE ROOF AND EQUIPMENT PLAN SHEET NUMBER A-1 SHEET 2 OF 7 SHEETS SCALE: 1/2" = l'-0" NOTES: 1. TYPE AND SIZES OF THE ANTENNA CABLES ARE BASED ON ESTIMATED LENGTH, PRIOR TO ORDERINGCABLE, CONTRACTOR TO VERIFY ACTUAL LENGTH BASED ON CONSTRUCTION LAYOUT AND NOTIFY ENGINEER IF ACTUAL LENGTH EXCEEDS ESTIMATED LENGTHS. 2. AS -BUILT DRAWINGS TO BE COMPLETED BY FIELD ENGINEER WITH ACTUAL LENGTHS. 3. AZIMUTHS ARE ORIENTED CLOCKWISE FROM TRUE NORTH. 2 A-1 SOUTH SHACKLEFORD SUITE 600 LITTLE ROCK, AR 72211 OFFICE- (501) 312-2455 x242 & GEM ENGINEERING COMPANY 10970 Stancliff Houston, Texas 77099-4206 Phone(281)561-9225 Fax 281 561-9399 71 PROJECT NOR LTR01OA DRAWN BY1 JC CHECKED BY- TA/HM SUBMITTALS DATE DESCRIPTION REV. 5-06-98 CONSTRUCTION REVIEW 5-08-98 PERMIT SCALE - 0 1/2 1 2 111 mill I I GRAPHIC SCALE IN INCHES LTRO10A RIVERCLIFF 2000 MAGNOLIA AVE. LITTLE ROCK, AR 72202 SHEET TITLE ROOF AND EQUIPMENT PLAN SHEET NUMBER A-1 SHEET 2 OF 7 SHEETS