Loading...
HomeMy WebLinkAboutZ-6659 Map 3(E) POWER \ SERVICE @ INTERSECTION OF 6TH & FERRY STREETS E) BUILDING CORNER Y=148854.21 34°44'31.19" LAT. ELEV - 369' @ TOP OF PARAPET WALL X=1233093.92 92015'49.45" LONG. 292.30' @ GROUND (E) SIGN (E) SIGN POSTS & BRACES (TYP) (E) SMALL VENT (TYP) (E) A/C DUCTS (E) ELEVATOR SHAFT (E) EQUIPMENT ROOM BELOW Y = 148718.15 34°44'29.83" LAT X = 1233082.50 92°15'49.58" LONG. ELEV = 374 BOTTOM OF PENTHOUSE OVERHANG 294.10 @ GROUND 0 (E) ELECTRIC CONDUITS Q ®# O p O O O EN a❑ (E) DRAIN/ \-(E) ASPHALT GATE (TYP.) ROOFING O O 0 ® O ET O p � O O ON N L•• GAS LI N E 293.72' @ GROUND O O ® O 0 ® O 0 O O miltI � I I I 0 L I Lj- (N) COAX GABLES v O�(N) ANTENNAS (TYP OF 6) O ® O O (E) ELECTRIC CONDUITS -(E) ACCESS HATCH ROOF PLAN SCALE: 1 (E) EXHAUST FAN (TYP) (E) CORRUGATED METAL SIDING Y = 148731.56 34°44'29.97" LAT ELEV = 374' BOTTOM OF PENTHOUSE OVERHANG X = 12331 12.70 92'15'49.22" LONG ,-293.62 @ GROUND 7' EAST OF CORNER I I � I I I t I - I E A C ( ) / I I I _ I I ELEVATOR I SHAFT � 1 2`-10" I FUTURE I I I I I GROWTH �% _ — I=zz: = — :N I CABINET I I (E) CEILING I PRIMARY I HEIGHT I CABINETI I I L_J I I I I I I I CAOBINET I LI I I L --I I I (E) OPENINGI C-2 } TO ROOF OF -\ F_ PENTHOUSE 0� (E) METER I & PANEL �iI I - (E) LADDER 7'-9" — �-- -- �G I / — — O i 7' C-1 -4 �G / EQUIPMENT LAYOUT SCALE: 3/8" = 1'-C" NOTES: 1. TYPE AND SIZES OF THE ANTENNA CABLES ARE BASED ON ESTIMATED LENGTH, PRIOR TO ORDERING CABLE, CONTRACTOR TO VERIFY ACTUAL LENGTH BASED ON CONSTRUCTION LAYOUT AND NOTIFY ENGINEER IF ACTUAL LENGTH EXCEEDS ESTIMATED LENGTHS. 2. AS -BUILT DRAWINGS TO BE COMPLETED BY FIELD ENGINEER WITH ACTUAL LENGTHS. 3. AZIMUTHS ARE ORIENTED CLOCKWISE FROM TRUE NORTH. (E) MICROFLECT PORTS MOUNTED ® CEILING HEIGHT B-1_ (N) ANTENNAS (TYP OF 6) �J SEE S-1 SHEET .s�l qZ TOR 6 7 2p. SECTOR ANT.TYPE COAX RAD SIZE CENTER AZIMUTH EST. CAB. LENGTH RX/TX DOWN TILT DEGREES COLOR CODE JUMPER SIZE JUMPER LENGTH Al DB978H90T2-M 1 5/8" 86'-6" O' 200'-0" RX 00 RW 1/2"o 6'-0" A2 DB978H90T2-M 1 5/8" 86'-6" 0' 200'-0" TX 00 RRY 11270 6'-0" B1 DB978H90T2-M 7/8" 90'-0" 120' 40'-O" RX 0° BW 1/2"0 6'-0" B2 DB978H90T2-M 7/8" 90'-O" 120' 50'-0" TX 00 BBY 1/2"0 6'-0" C1 DB978H90T2-M 7/8" 90'-0" 240' 70'-0" RX 00 GW 1/2"4 6'-0" C2 DB978H90T2-M 7/8" 90'-O" 240' 80'-0" TX 0° GGY 1/2"0 6'-0" TELECORP 900 S. SHACKLEFORD SUITE 800 LITTLE ROCK, AR 72211 OFFICE- (501) 312-2455 GEM ENGINEERING COMPANY 10970 Stoncliff Houston, Texas 77099-4206 Phone(281)561-9225 Fax 281 561-9399 PROJECT NO- LTR00 B DRAWN BY- GVS CHECKED BY- TA/HM SUBMITTALS DATE DESCRIPTION REV. 4-29-98'1 PERMIT �0 ARKANSAS •IL i_1 IL ♦ EGIS* RED R F ♦ �•� �Y No. 8768 SCALE - 0 1/2 1 2 I I 1 GRAPHIC SCALE IN INCHES LTRO02B INNTOWNE 600 INTERSTATE 30 LITTLE ROCK, AR 72202 SHEET TITLE ROOF PLAN SHEET NUMBER SHEET 2 OF 6 SHEETS