HomeMy WebLinkAboutZ-6610-A Staff AnalysisFILE NO.: Z -6610-A
NAME: Fitness for Life Short -form PD -O
LOCATION: Located at 9414 Colonel Glenn Road
DEVELOPER:
Curtis White
5911 Timber Side Road
Little Rock, AR 72204
SURVEYOR:
Blaylock Threet Engineers, Inc.
1510 South Broadway
Little Rock, AR 72202
A P'f /11 1 1 _r - /1 T.
Woods Group
Attn. Ron Woods
2200 Main Street
Little Rock, AR 72206
AREA: 1.136 acres
CURRENT ZONING:
ALLOWED USES:
PROPOSED ZONING
PROPOSED USE
NUMBER OF LOTS: 1
-m
Office
Revised PD -O
Health studio or spa
VARIANCEMAIVERS: None requested.
BACKGROUND:
FT. NEW STREET: 0 LF
Ordinance No. 17,490 adopted by the Little Rock Board of Directors on
February 16, 1999, rezoned the site from R-3, Single-family to PD -O. The approval
allowed the use of an existing one story frame residential structure as an office use.
FILE NO_: Z -6610-A (Cont_
The approval also allowed the construction of a 50 -foot by 60 -foot frame accessory
building immediately north of and behind the existing structure. It does not appear the
accessory structure was constructed on this site.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The applicant is requesting a revision to the previously approved PD -O to allow
the redevelopment of the site with a new fitness center. The structure is
approximately 9,800 square feet and is comprised of a training room, equipment
room, 1/2 gym floor, men and women restrooms with locker areas and showers,
office and a small cafe. No cooking will occur on the premises and only
pre-packaged food items will be sold. The site plan includes 20 parking spaces.
The owner is a trainer and his clients are scheduled to use the facility by
appointments. The facility is not open to the general public as a typical health
studio spa may be.
B. EXISTING CONDITIONS:
This area along Colonel Glenn Road contains a mixture of uses and zoning.
There is a church located immediately east of the proposed site, with
single-family residences to the west and south across Colonel Glenn Road.
A utility contracting business is located further west along the south side of
Colonel Glenn Road, with the Farmer's Association farm supply business located
across Colonel Glenn Road to the southwest.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received a few informational phone calls from area
residents. All owners of property located within 200 -feet of the site along with the
John Barrow, the Tall Timber, the West Heights Place and the Westwood
Neighborhood Associations were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Colonel Glenn Road is classified on the Master Street Plan as a principal
arterial. Dedication of right-of-way to 55 feet from centerline will be required.
2. With site development, provide the design of street conforming to the Master
Street Plan. Construct one-half street improvement to the street including
5 -foot sidewalks with the planned development. The new back of curb should
be located 29.5 feet from centerline. AHTD denied the proposed street
improvements as proposed by Public Works staff. A payment in -lieu of
construction for the widening of Colonel Glenn Road for the local contribution
to a future AHTD widening project should be provided. If the in -lieu payment
is not used in 10 years, the applicant can request the payment returned, with
interest.
2
FILE NO.: Z -6610-A (Cont.
3. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other than
residential subdivisions, site grading and drainage plans must be submitted
and approved prior to the start of construction.
4. Stormwater detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan.
5. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit
from the Arkansas Department of Environmental Quality prior to the start of
construction.
6. Street Improvement plans shall include signage and striping. Public Works
must approve completed plans prior to construction.
7. Streetlights are required by Section 31-403 of the Little Rock code. Provide
plans for approval to Traffic Engineering. Streetlights must be installed prior
to platting/certificate of occupancy. Contact Traffic Engineering, Greg
Simmons, gsimmons@littlerock.org or 501.379.1813 for more information.
8. How is the adjacent property to the west proposed to take access? The
neighbor's driveway appears to take access from the subject property.
9. Provide a letter prepared by a registered engineer certifying the sight distance
at the intersection(s) comply with 2004 AASHTO Green Book standards.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available to this project. Contact Little Rock Wastewater
Utility for additional information.
Entergy: Entergy does not object to this proposal. A three phase power line
exists on the north side of Colonel Glenn Road along the south side of the
property. Contact Entergy in advance regarding future service requirements and
additional facilities location(s) as this project proceeds.
CenterPoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. The Little Rock Fire Department needs to evaluate this site to determine
whether additional public and/or private fire hydrant(s) will be required.
If additional fire hydrant(s) are required, they will be installed at the
Developer's expense.
9
FILE NO.: Z -6610-A
3. Please submit plans for water facilities and/or fire protection system to
Central Arkansas Water for review. Plan revisions may be required after
additional review. Contact Central Arkansas Water regarding procedures
for installation of water facilities and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering Division and the Little Rock
Fire Department is required.
4. A Capital Investment Charge based on the size of meter connection(s) will
apply to this project in addition to normal charges. This fee will apply to all
connections including metered connections off the private fire system.
5. If there are facilities that need to be adjusted and/or relocated, contact
Central Arkansas Water. That work would be done at the expense of the
developer.
6. Contact Central Arkansas Water regarding the size and location of water
meter.
7. Due to the nature of this facility, installation of an approved reduced
pressure zone backflow preventer assembly (RPZA) is required on the
domestic water service. This assembly must be installed prior to the first
point of use. Central Arkansas Water requires that upon installation of the
RPZA, successful tests of the assembly must be completed by a Certified
Assembly Tester licensed by the State of Arkansas and approved by
Central Arkansas Water. The test results must be sent to Central Arkansas
Water's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 501.377.1226
if you would like to discuss backflow prevention requirements for this
project.
8. The facilities on-site will be private. When meters are planned off private
lines, private facilities shall be installed to Central Arkansas Water's
materials and construction specifications and installation will be inspected
by an engineer, licensed to practice in the State of Arkansas. Execution of
a Customer Owned Line Agreement is required.
9. Fire sprinkler systems which do not contain additives such as antifreeze
shall be isolated with a double detector check valve assembly. If additives
area used, a reduced pressure zone back flow preventer shall be required.
10. This development will have minor impact on the existing water distribution
system. Proposed water facilities will be sized to provide adequate
pressure and fire protection.
Fire Department: Maintain Access.
Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as
per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is located on a
fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
4
FILE NO_: Z -6610-A
Grade. Maintain fire apparatus access roads as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire
apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
Loading. Maintain fire apparatus access road design as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and
loading. Facilities, buildings or portions of buildings hereafter constructed shall
be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000
pounds.
30' Tali Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D105.1 — D105.4
D105.1 Where Required. Where the vertical distance between the grade
plane and the highest roof surface exceed 30', approved aerial fire apparatus
access roads shall be provided. For the purposes of this section the highest roof
surfaces shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls,
whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes
meeting this condition shall be located within a minimum of 15 feet and a
maximum of 30 feet from the building, and shall be positioned parallel to one
entire side of the building. The side of the building on which the aerial fire
apparatus access road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be
located over the aerial fire apparatus access road or between the aerial fire
apparatus road and the building. Other obstructions shall be permitted to be
places with the approval of the fire code official.
Dead Ends. Maintain fire apparatus access roads at dead end locations as
per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet
shall be provided with width and turnaround provisions in accordance with Table
D103.4. Requirements for Dead-end fire apparatus access roads.
Fire Hydrants. Locate Fire Hydrants as per Appendix C of the
2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction
with Central Arkansas Water (Jason Lowder 501-377-1245) and the Little Rock
Fire Marshal's Office (Captain Tony Rhodes 501-918-3757). Number and
Distribution of Fire Hydrants as per Table C105.1.
61
FILE NO.: Z -6610-A
Parks and Recreation: No comment received.
Counly Planning: No comment.
CATA: The site is located on CATA Bus Route #14 —the Rosedale Route.
F. ISSUES/TECHNICAL/DESIGN:
Building Code: Project is subject to full commercial plan review and approval
prior to issuance of a building permit. For information on submittal requirements
and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; cricheyCcD_1itt1erock.orq or
Mark Alderfer at 501.371.4875; malderfer ._littlerock.orq.
Planning Division: This request is located in the 1-430 Planning District. The
Land Use Plan shows Office (0) for this property. The Office (0) category
represents services provided directly to consumers (e.g., legal, financial,
medical) as well as general offices which support more basic economic activities.
The applicant has applied for a rezoning from PDO (Planned District Office) to
PDO (Planned District Office) to allow the construction of a physical fitness
center on the site.
Master Street Plan: Colonel Glenn Road is shown as a Principal Arterial on the
Master Street Plan. The primary function of a Principal Arterial Street is to serve
through traffic and to connect major traffic generator or activity centers within an
urbanized area. Entrances and exits should be limited to minimize negative
effects of traffic and pedestrians on Colonel Glenn Road since it is a Principal
Arterial. This street may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
Bicycle Plan: A Class II Bike Lane is shown along Colonel Glenn Road. Bike
Lanes provide a portion of the pavement for the sole use of bicycles.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements.
2. Screening requirements will need to be met for the vehicular use areas
adjacent to street right-of-ways. Provide screening shrubs with an average
linear spacing of not less at three (3) feet within the required landscape area.
Provide trees with an average linear spacing of not less than thirty (30) feet.
3. Trees and shrubs are required to be placed adjacent to street right-of-way.
Plant material is to be provided at the rate of one (1) tree and three (3) shrubs
for every 30 linear feet. Existing trees and vegetation can be used to satisfy
landscape requirements.
FILE NO.: Z -6610-A (Co
4. Eight percent (8%) of the vehicular use area must be designated for green
space; this green space needs to be evenly distributed throughout the parking
area(s). The minimum size of an interior landscape area shall be one hundred
fifty (150) square feet for developments with one hundred fifty (150) or fewer
parking spaces. Interior islands must be a minimum of seven and one half
(7 1/2) feet in width.
5. There is approximately seven thousand five hundred (7,500) square feet of
vehicular use area. Approximately six hundred (600) square feet of interior
landscape area will be required.
6. Trees shall be included in the interior landscape areas at the rate of
one (1) tree for every twelve (12) parking spaces.
7. An irrigation system shall be required for developments of one (1) acre or
larger.
8. For developments of less than one (1) acre there shall be a water source
within seventy-five (75) feet of the plants to be irrigated.
9. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
G. SUBDIVISION COMMITTEE COMMENT: (June 24, 2015)
The applicant was present. Staff presented an overview of the development
stating there were additional items necessary to complete the review process.
Staff requested additional information concerning the proposed use of the
property. Staff requested the applicant provide the proposed signage plan, the
days and hours of operation and the location of any proposed dumpster facilities
and the days and hours of dumpster service.
Public Works comments were addressed. Staff stated a dedication of right of
way was required to meet the master street plan requirement. Staff stated the
property was located on a State Highway. Staff stated the Highway Department
had denied staff's request for widening of Colonel Glenn Road. Staff stated
in -lieu of widening they were requesting a payment equal to the cost of the
widening to be held by the City for a match should the State widen the street.
Staff stated the property to the east appeared to take access across this
property. Staff stated an access easement should be granted to allow their
driveway to remain as currently configured. Staff stated moving the driveway on
this site and to the west was a concern due to the sight distance to the west
along Colonel Glenn Road.
Landscaping comments were addressed. Staff stated buffers would be required
around the site's perimeters. Staff stated eight percent (8%) of the vehicular use
area must be designated for green space. Staff stated for developments less
7
FILE NO.: Z -6610-A Cont_
than one (1) acre irrigation was not required but a water source within 75 -feet
was to be provided.
Staff noted the comments from the various other agencies. There were no more
issues for discussion. The Committee then forwarded the item to the full
Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to staff addressing most of the issues
raised at the June 24, 2015 Subdivision Committee meeting. The applicant has
provided the proposed signage plan, the days and hours of operation proposed
use of the property and noted there will not be a dumpster located on the site.
The structure is approximately 9,800 square feet. Within the building is a training
room, equipment room, 1/2 gym floor, men and women restrooms with locker
areas and showers, office and a small cafe. No cooking will occur on the
premises and only pre-packaged food items will be sold. The facility is not open
to general public on a walk in basis. The fitness center owner trains one on one
and fitness Glasses. Outdoor activities may occur with the fitness center. Any
area of outdoor activity will be screened by a wood fence. The hours of
operation are Monday through Saturday from 5:00 am to 9:00 pm and Sunday
from 2:00 pm to 6:00 pm.
The applicant has indicated a single ground sign will be placed along Colonel
Glenn Road. The sign will comply with signage allowed in office zones or a
maximum of 6 -feet in height and 72 square feet in area. Building signage will be
placed on the front facades of the building and along the south side with frontage
on Colonel Glenn Road. Signage is proposed to comply with signage allowed in
office zones or a maximum of ten (10) percent of the fagade area.
The building will be a combination of brick, masonry and EFIS with aluminum
fascia trim. The maximum building height is 29 -feet for all the buildings.
The applicant has indicated a payment in -lieu of street construction will be
provided along Colonel Glenn Road. The applicant has indicated a dedication of
right of way as per the Master Street Plan will be provided. The applicant has
indicated an easement will be provided to the adjacent property owner to allow
their existing driveway to remain.
Staff is supportive of the applicant's request. The applicant is proposing a
revision to the previously approved Planned Development to allow a fitness
trainer, health studio or spa, to construct a new building on the site. The
applicant has indicated compliance with the landscape and buffer ordinances will
be adhered to upon redevelopment of the site. To staff's knowledge there are no
remaining outstanding technical issues associated with the request.
0
FILE NO.: Z -6610-A (Cont.
STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda
staff report.
Staff recommends the applicant provide an in -lieu payment for the cost of street
construction to Colonel Glenn Road.
PLANNING COMMISSION ACTION:
(JULY 16, 2015)
The applicant was present. There were no registered objectors present. Staff
presented the item with a recommendation of approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E and F of
the agenda staff report. Staff presented a recommendation the applicant provide an
in -lieu payment for the cost of street construction to Colonel Glenn Road. There was no
further discussion. The item was placed on the consent agenda and approved as
recommended by staff by a vote of 11 ayes, 0 noes and 0 absent.
E
ITEM NO.: 11. Z
NAME: Fitness for Life Short -form PD -O
LOCATION: located at 9414 Colonel Glenn Road
Planning Staff Comments:
1. Provide notification of the property owners located within 200 -feet of the
development including the certified abstract list, notice form with affidavit executed
and proof of mailing. The notice must be mailed no later than July 1, 2015. The
Office of Planning and Development must receive the proof of notice no later than
July 10, 2015.
2. Provide the days and hours of operation for the proposed fitness center.
3. Provide the proposed signage plan including building and ground signage. Provide
the total height and total sign area for ground signage. Provide the percentage of
the fagade proposed from building signage.
4. Provide the location of any proposed dumpster and a note concerning the screening.
Will the hours of dumpster service be limited to daylight hours? If so note the hours
of dumpster service.
5. Provide a note on the site plan indicating the total square footage of the proposed
building.
6. Provide the proposed building materials for the proposed structure.
7. Provide the maximum building height proposed for the new construction.
8. Provide details of any proposed fencing. Include the location, total height and
construction materials.
9. All site lighting must be low level and directional, directed downward and into the
site.
10. Provide the percentage of building coverage, the percentage of paved area and the
percentage of landscaped area in the general notes of the site plan.
11. Provide details of the proposed activities that will take place on the site. Will there
be multiple clients or is this a one on one client to trainer.
12. Will there be any outdoor activities taking place as a part of the exercise/training? If
so provide details of the outdoor training.
Variance/Waivers- None requested.
Public Works Conditions:
1. Colonel Glenn Road is classified on the Master Street Plan as a principal arterial.
Dedication of right-of-way to 55 feet from centerline will be required.
2. With site development, provide the design of street conforming to the Master Street
Plan. Construct one-half street improvement to the street including 5 -foot sidewalks
with the planned development. The new back of curb should be located 29.5 feet
from centerline. AHTD denied the proposed street improvements as proposed by
Public Works staff. A payment in -lieu of construction for the widening of Colonel
Glenn Road for the local contribution to a future AHTD widening project should be
provided. If the in -lieu payment is not used in 10 years, the applicant can request
the payment returned, with interest.
3. Obtain permits for improvements within State Highway right-of-way from AHTD,
District VI. AHTD is being contacted for approval of street widening and information
will be provided to applicant.
4. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction.
5. Stormwater detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan.
6. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
7. Street Improvement plans shall include signage and striping. Public Works must
approve completed plans prior to construction.
8. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans
for approval to Traffic Engineering. Streetlights must be installed prior to
platting/certificate of occupancy. Contact Traffic Engineering, Greg Simmons,
gsimmions@littlerock.org or 501.379.1813 for more information.
9. How is the adjacent property to the west proposed to take access? The neighbor's
driveway appears to take access from the subject property.
10. Provide a letter prepared by a registered engineer certifying the sight distance at the
intersection(s) comply with 2004 AASHTO Green Book standards.
Utilities and Fire Department/County Planning:
Wastewater: Sewer available to this project. Contact Little Rock Wastewater Utility
for additional information.
Entergy: Entergy does not object to this proposal. A three phase power line exists on
the north side of Colonel Glenn Road along the south side of the property. Contact
Entergy in advance regarding future service requirements and additional facilities
location(s) as this project proceeds.
CenterPoint Energ No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for water
service must be met.
2. The Little Rock Fire Department needs to evaluate this site to determine whether
additional public and/or private fire hydrant(s) will be required. If additional fire
hydrant(s) are required, they will be installed at the Developer's expense.
3. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional review.
Contact Central Arkansas Water regarding procedures for installation of water
facilities and/or fire service. Approval of plans by the Arkansas Department of
Health Engineering Division and the Little Rock Fire Department is required.
4. A Capital Investment Charge based on the size of meter connection(s) will apply to
this project in addition to normal charges. This fee will apply to all connections
including metered connections off the private fire system.
5. If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
6. Contact Central Arkansas Water regarding the size and location of water meter.
7. Due to the nature of this facility, installation of an approved reduced pressure zone
backflow preventer assembly (RPZA) is required on the domestic water service.
This assembly must be installed prior to the first point of use. Central Arkansas
Water requires that upon installation of the RPZA, successful tests of the assembly
must be completed by a Certified Assembly Tester licensed by the State of Arkansas
and approved by Central Arkansas Water. The test results must be sent to Central
Arkansas Water's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 501.377.1226 if you
would like to discuss backflow prevention requirements for this project.
8. The facilities on-site will be private. When meters are planned off private lines,
private facilities shall be installed to Central Arkansas Water's materials and
construction specifications and installation will be inspected by an engineer, licensed
to practice in the State of Arkansas. Execution of a Customer Owned Line
Agreement is required.
9. Fire sprinkler systems which do not contain additives such as antifreeze shall be
isolated with a double detector check valve assembly. If additives area used, a
reduced pressure zone back flow preventer shall be required.
10. This development will have minor impact on the existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire
protection.
Fire Department: Maintain Access.
Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access
road width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall
not exceed 10 percent in grade except as approved by the fire chief.
Loading. Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities,
buildings or portions of buildings hereafter constructed shall be accessible to fire
department apparatus by way of an approved fire apparatus access road with an
asphalt, concrete or other approved driving surface capable of supporting the imposed
load of fire apparatus weighing at least 75,000 pounds.
30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1 — D105.4
D105.1 Where Required. Where the vertical distance between the grade plane
and the highest roof surface exceed 30', approved aerial fire apparatus access roads
shall be provided. For the purposes of this section the highest roof surfaces shall be
determined by measurement to the eave of a pitched roof, the intersection of a roof to
the exterior wall, or the top of the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the building
or portion thereof.
D105.3 Proximity to building. At least one of the required access routes
meeting this condition shall be located within a minimum of 15 feet and a maximum of
30 feet from the building, and shall be positioned parallel to one entire side of the
building. The side of the building on which the aerial fire apparatus access road is
positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over
the aerial fire apparatus access road or between the aerial fire apparatus road and the
building. Other obstructions shall be permitted to be places with the approval of the fire
code official.
Dead Ends. Maintain fire apparatus access roads at dead end locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4
Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water
(Jason Lowder 501-377-1245) and the Little Rock Fire Marshal's Office (Captain Tony
Rhodes 501-918-3757). Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comment received.
County Planning: No comment.
CATA: The site is located on CATA Bus Route #14 — the Rosedale Route.
Building Code: Project is subject to full commercial plan review and approval prior to
issuance of a building permit. For information on submittal requirements and the review
process, contact a commercial plans examiner: Curtis Richey at 501.371.4724;
cricheya-littlerock.org or Mark Alderfer at 501.371.4875; malderfer. @,littlerock.org.
Planning Division: This request is located in the 1-430 Planning District. The Land Use
Plan shows Office (0) for this property. The Office (0) category represents services
provided directly to consumers (e.g., legal, financial, medical) as well as general offices
which support more basic economic activities. The applicant has applied for a rezoning
from PDO (Planned District Office) to PDO (Planned District Office) to allow the
construction of a physical fitness center on the site.
Master Street Plan: Colonel Glenn Road is shown as a Principal Arterial on the Master
Street Plan. The primary function of a Principal Arterial Street is to serve through traffic
and to connect major traffic generator or activity centers within an urbanized area.
Entrances and exits should be limited to minimize negative effects of traffic and
pedestrians on Colonel Glenn Road since it is a Principal Arterial. This street may
require dedication of right-of-way and may require street improvements for entrances
and exits to the site.
Bicvcle Plan: A Class II Bike Lane is shown along Colonel Glenn Road. Bike
Lanes provide a portion of the pavement for the sole use of bicycles.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements.
2. Screening requirements will need to be met for the vehicular use areas adjacent
to street right-of-ways. Provide screening shrubs with an average linear spacing
of not less at three (3) feet within the required landscape area. Provide trees with
an average linear spacing of not less than thirty (30) feet.
3. Trees and shrubs are required to be placed adjacent to street right-of-way. Plant
material is to be provided at the rate of 1 tree and 3 shrubs for every 30 linear
feet. Existing trees and vegetation can be used to satisfy landscape
requirements.
4. Eight percent (8%) of the vehicular use area must be designated for green
space; this green space needs to be evenly distributed throughout the parking
area(s). The minimum size of an interior landscape area shall be one hundred
fifty (150) square feet for developments with one hundred fifty (150) or fewer
parking spaces. Interior islands must be a minimum of seven and one half (7 1/2)
feet in width.
5. There is approximately seven thousand five hundred (7500) square feet of
vehicular use area. Approximately six hundred (600) square feet of interior
landscape area will be required.
6. Trees shall be included in the interior landscape areas at the rate of one (1) tree
for every twelve (12) parking spaces.
7. An irrigation system shall be required for developments of one (1) acre or larger.
8. For developments of less than one (1) acre a there shall be a water source within
seventy-five (75) feet of the plants to be irrigated.
9. The City Beautiful Commission recommends preserving as many existing trees
as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or larger.
Revisedplat/plan'. Submit four (4) copies of a revised preliminary plat/plan (to include