Loading...
HomeMy WebLinkAboutZ-6572-C Map� r T"g.a ate, PROJECT INFORMATION SCOPE OF WORK: UNMANNED TELECOMMUNICATIONS FACILITY MODIFICATIONS SITE ADDRESS: 8200 FLINT RIDGE ROAD LITTLE ROCK, ARKANSAS 72210-4014 LATITUDE 34' 40' 43.7' N LONGITUDE 92' 24' 36.71' W JURISDICTION: PULASKI COUNTY, ARKANSAS CURRENT USE: TELECOMMUNICATIONS FACILITY PROPOSED USE TELECOMMUNICATIONS FACILITY A/E DOCUMENT REVIEW STATUS Butum pods REV 24782 -LTR -0024-01 ►�eepted - ■ith minor or no comments con—cuon I 24782 -LTR -0024-02 m� 8 24782 -LTR -0024-03 Not ieoepfad - Please reaohe oomments and resubmit ►coeptence doer not eapetltnb epprurel o[ drd� dntane. alcolatisne. 4 teat m.l er metariils dsrrioped or r-.�-w019 br the enbocetracler end roe ani rollers suboeatractar truce Poll compliance wltL oeetreatma ahltpHcae. tte�errd Date ]4PGD11�ft p CANS1• UCFl9N GD'ICaIJR NOTES 1. SEE THEFOLLOWINGSYMBOLS BOF THIS DOCUMENT DRAWING INDEX REV 24782 -LTR -0024-01 TITLE SHEET 0 24782 -LTR -0024-02 SITE PLAN 0 24782 -LTR -0024-03 ELEVATION VIEW AND RF NOTES 0 24782 -LTR -0024-04 SLAB DETAILS 0 24782 -LTR -0024-05 CONSTRUCTION NOTES 0 24782 -LTR -0024-06 GPS MOUNTING DETAILS 0 24782 -LTR -0024-07 CONSTRUCTION DETAILS 0 24782 -LTR -0024-08 ELECTRICAL NOTES AND DETAILS 0 24782 -LTR -0024-09 GROUNDING DETAILS 0 24782-011-0024-10 GROUNDING DETAILS 0 24782 -LTR -002411 GROUNDING PLAN 0 24782 -LTR -0024-12 COAX COLOR CODING 0 24782 -LTR -0024-13 RISER DIAGRAM 0 24782 -LTR -0024-14 TELCO CONNECTION DIAGRAM 0 24782 -LTR -0024-15 RF AUTOMATIC DOWNTILT SCHEMATIC 0 24782 -LTR -0024-16 SHELTER LAYOUT AND CABINET DETAILS 0 NOTES 1. SEE THEFOLLOWINGSYMBOLS BOF THIS DOCUMENT 24782-000-A3 FOR IMPLEMENTATION SITE DESIGN PACKAGE CONCRETE AND REINFORCING STEEL NOTES DETAIL 102 APPLICABLE BUILDING CODES AND STANDARDS DETAIL 103 RF NOTES DETAIL 116 DETAIL SITE WORK GENERAL NOTES STRUCTURAL STEEL NOTES r DETAIL 620 ELECTRICAL INSTALLATION NOTES DETAIL 622 GENERAL NOTES DETAIL 6x3 1 ICE BRIDGE DETAILT"� DIRECT BURIED CONDUIT DETAIL 105 ANTENNA CABLE GROUNDING MONOPOLE AIL 16132 GROUND ROD INSTALLATION OF GROUND WARE TO GROUND BAR DETAIL 118 REFERENCE GRDUND BAR (RGB) DETAIL DETAILETAIL 119 DETAIL 122 CONNECTION OF GROUND WARE TO GROUNDING BAR DETAIL 644 GROUND ROD WITH ACCESS AREA DETAIL 636 COAK COLoR CODING AND 10 DETAIL FOR GREENF7EDS DETAIL 112 A88REVIATIONS AND SYMBOLS CONNECTION OF CABLE GROUND KIT TO ANTENNA CABLE DETAIL S 21 ANTENNA CABLE GROUNDING. a SURGE ARRESTORS AT SHELTER DETAIL 129 WAMNCR DESIGN GROUP 2775 Villa Creek Dr., Suite 150, Dallas, Texas 75234 Phone: (972) 484-6855 Pax: (972) 484-6830 WDG PROJECT 4050502 6 ASBU [LT REDLINE THE MARK-UP ON THIS DRAWING REFLECTS THE AS -BUILT INSTALLATION. Subcontractor Date Field CoordiDafnr Date Market Engineer Sharif Review Redline Drawings 7D Enwre Charges M Not Alter The OriCmf Design Intent And/or Are Code Co runt 3LTcet Lead I aglneer Date VICINITY MAP '-/4/6Z- I bZ-H l A0K ' 1V is fM cingular WIRELESS ARKANSAS INTEGRATION SITE NUMBER: AR1524 SITE NAME: STAGECOACH (L-024) DIRECTIONS: FROM LITTLE ROCK, GO WEST ON 1-630 TO 1-430, GO SOUTH ON 1-430 TO STAGECOACH ROAD. TAKE THE EXIT AND GO RIGHT AND TAKE THE IMMEDIATE RIGHT ROAD (FUNTRIDGE ROAD) ON RR SITE IS LOCATED BEHIND CHURCH. t •,} rf ~� N APPLICABLE BUILDING CODES AND STANDARDS SUBCONiRACTDR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF WNTRAGT AWARD SHALL GOVERN THE DESIGN. BUILDING CODE/ FIRE PRIM NlION/ SAFETY/ ACCESSIBILTY CODE: 2000 INTERNATIONAL BUILDING CODE (18C) 2o0o INTERNATIONAL FIRE CODE (IFC) APT-, MECHANICAL CODE., cITTTsI'-TCS l:[ +�:L'i u.t� 2003 ARKANSAS MECHANICAL CODE ELECTRICAL CODE. 2005 NA 0M ELECTRICAL CODE (NEC) Date: GAS CODE Yii`� 1v1','s isi FRO �'�iO�/s� 1995 ARKANSAS STATE GAS CODE rY. c. i S -` • v - `1ff FAWr � VaIDS L. _' �C: &I ' SUBCONTRACTOR'S WORK SHALL COMPLY WITH EDITION OF THE FOLLOWING STANDARDS. AMERICAN CONCRETE INSTITUTE 11 318, BUILDING CODE REQUIREMENTS FOR SiRUCTI]RAL CONCRETE AMERICAN INSTTTUTE OF STEEL CONSTRUCTION (RISC), MANUAL OF STEEL CONSTRUCTION, ASD- NiNM EDITION TELECOMMUNICATIONS INDUSTRY ASSOCIATTON [ITA] 222-F, STRUCTURAL. STANDARDS FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES: TLA 607, COMMERCIAL BUILDING GROUNDING AND BONDING REOUIREMENTS FOR TELECOMMUNICATIONS INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81. GUIDE FOR MEASURING EARTH RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC EQUIPMENT IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION CATEGORY "C3' AND 'HIGH SYSTEM EXPOSURE'] TELCORDIA GR -1275, GENERAL INSTALLATION REQUIREMENTS TELCORDIA GR -1503. COAXIAL CABLE CONNECTIONS ANSI T1.311, FOR TELECOM - DC POWER SYSTEMS - TELECOM, ENVIRONMENTAL PROTECTION FOR ANY CONFLICTS BETWEEN SECTIONS OF LI&,THE STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIEM ST RESTRICTIVE REQUIREMENT SHALL GOVERN. WHERE THERE LS CDNL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFICREOUIfA IN C N. A v IYT CINGULAR WIRELESS STAGECOACH (L-024)' SITE NO. AR1524 Xcin g u l a t' Q TITLE SHEET 13200 FLINT RIDGE RD ROCK, ARKANSAS 72210 J ,M�� D 02/14/06 LS�VFA FOR COX57ROCi1Dlf n cr c PRL >U- fir] DATE R610NS 9Y CHK NCC EV WE Pzu�vane wnr.Px P= LITTLE .7 7f12 LTR -024 24782 -LTR -024-01 0 sCAM As SHOWN DES"ED gµ A DRAWN BY, It 3 2 17 5 4 /PSa 5 ;L 1.1 r< PLACE (N) 11--5- SLAB FOR (N (RE PLACE (N) ERIC 2106 GSM & 3 CABINETS IN (N MOON ANTENNA 1 (RE (N) II (FtE (E) EQU BE RE (E) (6) 1-5/8' C( REUSED & (N) ( COAX TO (E) I (E) 18W A7'_R, WA CE DES I CA+ C ROUP 2775 Villa Creek Dr., Suite 150, Dallas, Texas 75234 Phone (972) 484-6855 Fax-. (472) 484.6830 WDG PROJECT #OS0502 6 5 SITE PLAN 1 SCALE: 3/16"=1'—O' � STAGECOACH (L-024) SITE NO. AR1524 8200 FLINT RIDGE RD LITTLE ROCK, ARKANSAS 72210 n N ' PVC SCHEDULE 40 CONDUIT TELCO WITH 1800 LB MULE L STRINGS AND CAPS & 105/08) NO. MATE RENSIONS BY CNx AND (1) 16 GROUND IN 2' PVC `4 $*i 40 PIPE FOR (N) U.G. POWER 4 3 2 71X34 92E Frsr— tel fl do 105/08) STAGECOACH (L-024) BOK SBA Siff j: AR05003 POINT OF FCC REGISTRATaON NO. 1228474 )N) Z PANEL NOTE' POINT OF OPTIONAL POWER AND T1 — PLACEMENT OF H—FRAME )N) STAND—OFF FROM POWER SOURCE AND UNDERGROUND CONDUITING FROM TRANSFORMER POLE FOR POWER AND T1. CONDUITING FROM H—FRAME TO EQUIPMENT FOR POWER AND T1. C (RE: 1/13 do 1/14) GENERAL NATE SCALE NOTED APPLIES TO 22"x34' SHEET SIZE IF PRINT SIZE IS 11707'. THEN ACTUAL SCALE IS ONE HALF OF SCALE NOTED. EXAMPLE 1/2' = 1'--0' BECOMES 1/4' — 1'-0' ON 11'x17' SHEET SIZE). THIS NOTE APPLIES TO ALL DRAWING SHEETS. i3 LEGEND EXISTING EQUIPMENT 0 NEW EQUIPMENT r----, FUTURE EQUIPMENT EXISTING CABLE TRAY/ BRIDGE NEW CABLE TRAY/ BRIDGE CONDUCTORS AND RACEWAY TO BE FURNISHED & INSTALLED BY SUBCONTRACTOR N ')41s4-.. InnrlAI7f7nte► A c ng u E ar MHELESS CINGULAR WIRELESS 4 ��' * SITE PLAN j> '+' j �S S��. Ae WJLW SrE �R�RER neuwu+� i, L'vt rtR• J o 02/14/06MSMFOR �N ,: t� a NO. MATE RENSIONS BY CNx SCALe AS sNowN DESIGNM BY T� Dwrne eK n `4 $*i LTR -024 24782—LTR-024-02 0 4 3 2 71X34 92E Frsr— tel I. TOP OF TOWER ELEV ** 180=_6— % ANTENNA CENTER_ ELEV 1 175 —0 NOTE: (E) TMAs TO BE REPLACED (N) (6) EMS WIRELESS MB48RRSOVDPL2 WITH (N) (12) TMAs MODEL ANTENNAS TO REPLACE (E) ANTENNAS III LGP17205 (2) PER SECTOR (IE)_ANTENNA EI.EV 144 =D � -- (E) 180'-0' MONOPOLE (E) (5) 1 5/8' COAX & (N) (6) 1 5/8' COAX INSIDE MONOPOLE (E) ICE BRIDGE (N) ICE BRIDGE (RE 155/07) (N) SHELTER FINISHED GRADE ELEV f 0 ,4 NOTE: STRUCTURAL ANALYSIS OF TOWER PROVIDED BY OTHERS. REPLACE (E) SURGE ARRESTORS WITH HUBER- SUMER HS3409-41-0048 TOWER ELEVATION 1 SCALE- WALLACE DESK;N CROUP 2775 Villa Crock Dr, Suitt 150, Dallas, T=aa 75234 Phone: (9721 484.6855 Fax: (972) 484.6830 IDG PROJECT #OS0502 2 5 STAGECOACH (L-024) SITE NO. AR1524 6200 FLINT RIDGE RD LITTLE ROCK, ARKANSAS 72210 Z� (E) MONOPOLE T 1 Cz m' b [N) (6) EMS WIRELESS. �I MB48RRBOVOPL2 ANTENNAS. (2) ANTENNAS PER SECTOR TWO ANTENNA CONFIGURATION TOWER MOUNTING (PLAN VIEW DETAIL 2 NTS ()� XCingular WIRFI.ESS 4 4 3 RF NOTES 1. ACTUAL LENGTHS SHALL BE DETERMINED PER SITE CONDITION BY SUBCONTRACTOR. 2. THE DESIGN IS BASED ON RF DATA SHEETS, SIGNED AND APPROVED. 3. RADIO SIGNAL CABLE AND RACEWAY SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC, NFPA 70), CHAPTER 8. 4. ALL SPECIFIED MATERIAL FOR EACH LOCATION (E.G., OUTDOORS, INDOORS -OCCUPIED, INDOORS -UNOCCUPIED. PLENUMS. RISER SHAFTS, ETC.) SHALL BE APPROVED, LISTED, OR LABELED AS REQUIRED BY THE NEC. 5. RADIO SIGNAL CABLE SHALL BE SUPPORTED AT MINIMUM OF EVERY THREE (3) FEET EXCEPT INSIDE MONOPOLES OR LATTACE TOWERS WHERE CABLE AND CONNECTOR MANUFACTURERS SUPPORT RECOMMENDATIONS SHALL BE FOLLOWED. MANUFACTURER RECOMMENDED CABLE SUPPORT ACCESSORIES SHALL BE USED. S. THE OUTDOOR CABLE SUPPORT SYSTEM SHALL BE PROVIDED WITH AN ICE SHIELD TO SUPPORT AND PROTECT ANTENNA CABLE RUNS. 7. DRIP LOOPS SHALL BE REQUIRED ON ALL OUTSIDE CABLES. CABLES SHALL BE SLOPED AWAY FROM THE BUILDING OR OUTDOOR BTS CABINETS TO PREVENT WATER FROM ENTERING THROUGH THE COAXIAL CABLE PORT. S. ALL FEEDER LINE AND JUMPER CONNECTORS FOR CINGULAR GSM SHALL BE CINGULAR APPROVED 7/16 DIN CABLE CONNECTORS THAT MEET IPG8 STANDARDS. F��7a4giy�7 10. 7/16 DIN CONNECTORS REQUIRE NO ADDITIONAL WEATHER PROOFING IN INDOOR APPLICATIONS IF INSTALLED AND TORQUED PROPERLY. IN OUTDOOR APPLICATIONS WEATHER PROOFING IS REQUIRED AND THE FOLLOWING PROCEDURE SHOULD BE FOLLOWED: APPLY A 'COURTESY WRAP OF ONE LAYER OF 7MIL THICK VINYL ELECTRICAL TAPE EXTENDING APPROXIMATELY ONE (1) INCH ON EACH SIDE OF THE COAX CABLE/ CONNECTOR JUNCTURE USING WEATHERPROOFING KIT APPROVED BY CABLE MANUFACTURE AND CONTRACTOR. START TAPE APPROXIMATELY 5 INCHES FROM THE CONNECTOR AND WRAP 2 INCHES TOWARD THE CONNECTOR. THEN REVERSE THE TAPE SO THAT THE STICKY SIDE IS UP. TAPE OVER THE CONNECTOR OR SURGE ARRESTOR UNTIL THREE (3) TO FOUR (4) INCHES BEYOND THE CONNECTOR AND REVERSE AGAIN WITH THE STICKY SIDE DOWN FOR ANOTHER INCH OR TWO. ADD THE BUM RUBBER AND FINISH WITH A FINAL LAYER OF TAPE. f M1];IIF3gj;I 12. ANTENNAS SHALL BE PAINTED. WHEN REQUIRED, BY THE LANDLORD OR AUTHORITY HAVING JURISDICTION IN ACCORDANCE WITH ANTENNA MANUFACTURERS' SURFACE PREPARATION AND PAINTING REQUIREMENTS. 13. CABLE SHIELDS, AND TOWER CONDUITS SHALL BE GROUNDED AT THE TOP OF THE TOWER, WITHIN 10 FEET OF THEIR CONNECTORS, AND AT THE BOTTOM OF THE TOWER ABOUT 6 INCHES BEFORE THEY TURN TOWARD THE FACILITY. THEY SHALL BE GROUNDED AT THE MIDPOINT OF TOWERS THAT ARE BETWEEN 100 FEET AND 200 FEET HIGH, AND AT INTERVALS OF 100 FEET OR LESS ON TOWERS THAT ARE HIGHER THAN 200 FEET. 14. APPROVED GROUNDING KITS, WHICH INCLUDE GROUNDING STRAPS, SHALL BE USED TO GROUND THE COAXIAL CABLE SHIELDS, AND CONDUITS. THE GROUND CONDUCTORS FOR THE KITS AT THE TOP OF THE TOWER, AND IN THE MIDDLE SECTION OF THE TOWER, ARE BONDED DIRECTLY TO TOWER STEEL USING EXOTHERMIC, BOLTED, OR APPROVED CLAMP CONNECTIONS. 15. ALL RADIO SIGNAL CABLE SHALL BE LABELED PER MARKET REQUIREMENTS 16. DELETED 17. DELETED 1B. MHA/TMA'S TO BE INSTALLED AT TOWER TOP, SHALL BE SUPPLIED TO THE SUBCONTRACTOR (WERE REWIRED) AND INSTALLED BY THE SUBCONTRACTOR. THE GROUND CONDUCTORS OF THE TMA MAY BE BONDED DIRECTLY TO THE TOWER STEEL USING EXOTHERMIC, BOLTED, OR APPROVED CLAMP CONNECTIONS. 19. ANTENNA FEED LINE SYSTEM SWEEP TESTING SHALL. BE PERFORMED AND REPORTED iN ACCORDANCE WITH THE REQUIREMENTS OF CENGULAR-GSM SERVICES PROJECT DOCUMENT NO. 24782-000-3PS-MO--00001. CONTRACTOR WILL NOT ACCEPT A MID SIGNAL CABLE 26TALUI.TION WITH UNSATISFACPURY SWEEP TEST RESULTS. !/14/081 WOED FOR CONSFiH1MN DATE REVISIONS AS SHOWN I DESIGNED aY: TL DRAWN sw TL CINGULAR WIRELESS * % -- f L'CJZO J ALEVATION VIEW AND RF NOTES LTR -0241 24782 -LTR -024-03 PSI u C B A