HomeMy WebLinkAboutZ-6560-B Map 4~ 1 (N) CABLE- TIE (N) CABLES TO (E) POLE USING PER THE FOLLOWING INSTRUCTION: o S-1 BRIDGE �TRANSMISSION BRACKET \\ 1. LOCATION: MARKINGS SHALL BE MADE USING B2336 OR EQUAL, COLOR TAPE W/3" OF COVERAGE AFFIXED AT z4'-0" APPART (N) GPS WITH 1/2 \ THREE PLACES ON THE COAX CABLE RUN AS Ld FOAM CABLE, 12' FOLLOWS: o ABOVE GROUND Q FIRST- ON THE COAX AT THE CONNECTOR n 1 (N) T -MOBILE -- NEAREST THE ANTENNA (WHERE THE COAX AND MONOPOLE C-5 CITYTALK EQUIPMENT JUMPER ARE CONNECTED). -MINIMUM ONE SECOND- AT THE BASE OF THE TOWER BAND REQUIRED 6 (N) PPC AND- STRUCTURE (FOR TOWERS ONLY). SNAP -IN- AT TOP. SECOND E-4 TELCO RACK HANGERS BAND MAY BE THIRD- AT A POINT OUTSIDE THE BTS (JUST MICROFLECT USED FOR PRIOR TO MGB) 1562 OR ADDITIONAL -(E) WOODEN FENCE EQUAL SUPPORT. 2. SECTOR IDENTIFICATION: NORMALLY A SITE MONOPOLE WILL HAVE UP TO THREE SECTORS. SECTORS TRANSMISSION VBANDING SHALL BE DESIGNATED IN A CLOCKWISE LINE BRACKET MICROFLECT MANNER; THE ALPHA SECTOR IS CLOSEST MICROFLECT B1769 OR -\ - GROUND ELEVATION 302' TO ZERO DEGREES (NORTH) THE BETA B2336 OR EQUAL AND GAMMA FOLLOW CLOCKWISE IN EQUAL \ (N) CONCRETE---// ONCRETE (E) MONOPOLE SEQUENCE. S-1 PAD FOUNDATION TRANSMISSION ANTENNA AND COAXIAL CABLE SCHEDULE COAX ANTENNA AZIMUTH DOWNTILT ASSEMBLY REQUIRED COAXIAL CABLE (SIX RED) (FIVE RED) MARK ANTENNA ARE FOR ALL PANEL TYPE ANTENNAS A-1 rn L ANALYSIS AND DESIGN OF TOWER ANTENNA MOUNTING DESIGNED TO MEET LOCAL BUILDING c,4 RR65-19-OODP (FOUR RED) (TWO RED ) (ONE RED) (THREE RED) o AND FOUNDATION BY OTHERS. REFER CODES AND ANSI\IA/EIA-222-F ®� o 00 a A-3 TO APPROPRIATE SHEETS NO ERECTION OR FOR MORE INFORMATION. MODIFICATION TOWER STRUCTURAL STANDARDS FOR STEEL (1) - 1-5/8" 0 _DOWNTILT ASSEMBLY LDIVERSITY] J 105' AND FOUNDATION E SHALL BE MADE WITHOUT ANTENNA SUPPORTING STRUCTURES, IS ANTENNA PIPE REQUIRED FOR ALL z -FUTURC -_MAIN - A-2 A--3 A-1 APPROVAL OF STRUCTURAL ENGINEER THE DESIGN WIND SPEED \ PANEL TYPE CD 105' 135' (1) - 1-5/8" 0 90 MPH (3 SECOND GUST SPEED) ANTENNAS 105' Ep �? (1) - 1-5/8" 0 RR65-19-OODP 120" TNA/LNA COMBINER \ (THREE BLUE) SECTOR 1 (FOUR YELLOW) - B-3 (OUTLETS TO FACE \ C-1 ALPHA B-2 (1) - 1-5/8" 0 B-2 DOWN -VERTICAL) -------- (ONE BLUE) (TWO YELLOW) RR65-19-OODP 120 #6 SHIELD 0° (TYPICAL) L 3-4 (MECHANICAL 135' -MAIN---J -DIVERSITY 105' 135' GROUND VIA ROUND RR65-19-OODP 240' 120° MEMBER ADAPTER)- C-3 105' 135' (1) - 1-5/8" 0 C-2 (FIVE BLUE) SIX YELLOW ) 165' 135' (1) - 1-5/8" 0 RR65-19-OODP 240 0, SECTOR 3 SECTOR 2 No. 6 STANDARD - �t C-3 \1 GAMMA BETA v*B- 3 105' 135' (1) - 1-5/8" 0 GREEN INSULATED 0 j CONTRACTOR TO FIELD VERIFY (SIX BLUE) (FIVE YELLOW) GROUND WIRE TO FUTURE UPPER ANTENNA FUTUREJ GROUND BAR (2 HOLE LUGS EA. END)-- (TWO BLUE) (ONE YELLOW) JUMPERS TO BE C-2 B-1 (E) ANTENNAS SECURED WITH (FOUR BLUE) (THREE YELLOW) ANDREWS BUTTERFLY RFL - - -- HANGERS W/ 1" STANDOFFS- DIVE RSITYMAIN (E) ANTENNAS RR65-19-OODP \ 112" FOAM COAX JUMPER ----I ANTENNA (MAX LENGTH 6') 12 -LINE COLOR CODING TRANSMISSION_ NOTE: ALL DOWN TILT, LINES TO BTS -�- -� AZIMUTHS AND LNA'S PROPOSED T -MOBILE 2,3 - -- C-3 TO BE VERIFIED BY RF NOTE: ANTENNAS CL @ 105'-0" SITE DATA SHEET. SEE 1- AZIMUTHS SHOWN ARE TYPICAL. ---- - -- -----PROJECT PANEL ANTENNA MOUNTING MANAGER SEE REDS FOR A (2+1 FUTURE ANTENNAS PER SECTOR) 6 FOR INFORMATION. 2- AZIMUTH WILLCTUAL BE PLACED BYAZIMUTHS. AZIMUTH 0" @ 105' RAD CENTER MIN_ MAGNETIC NORTH ONLY Lu J 5 (N) COAX CABLES- AZIMUTH 120° @ 105' RAD CENTER a- c-3 TO RUN OUTSIDE AZIMUTH 240` @ 105' RAD CENTER oz OF EXISTING POLE ' - BIPOLAR PANEL ANTENNA 3 TYPICAL ANTENNA PLAN 2 AND LNA MOUNTING DETAIL 0 (E) 130'-0" MONOPOLE oC-3 SCALE: N.T.S. o Q z I z o w I- � z w COAX CABLE IDENTIFICATION m CONTRACTOR MUST PROVIDE EASY IDENTIFICATION AND UNIFORM MARKING OF ANTENNA CABLING ~ 1 (N) CABLE- TIE (N) CABLES TO (E) POLE USING PER THE FOLLOWING INSTRUCTION: o S-1 BRIDGE �TRANSMISSION BRACKET \\ 1. LOCATION: MARKINGS SHALL BE MADE USING B2336 OR EQUAL, COLOR TAPE W/3" OF COVERAGE AFFIXED AT z4'-0" APPART (N) GPS WITH 1/2 \ THREE PLACES ON THE COAX CABLE RUN AS Ld FOAM CABLE, 12' FOLLOWS: o ABOVE GROUND Q FIRST- ON THE COAX AT THE CONNECTOR n 1 (N) T -MOBILE -- NEAREST THE ANTENNA (WHERE THE COAX AND MONOPOLE C-5 CITYTALK EQUIPMENT JUMPER ARE CONNECTED). -MINIMUM ONE SECOND- AT THE BASE OF THE TOWER BAND REQUIRED 6 (N) PPC AND- STRUCTURE (FOR TOWERS ONLY). SNAP -IN- AT TOP. SECOND E-4 TELCO RACK HANGERS BAND MAY BE THIRD- AT A POINT OUTSIDE THE BTS (JUST MICROFLECT USED FOR PRIOR TO MGB) 1562 OR ADDITIONAL -(E) WOODEN FENCE EQUAL SUPPORT. 2. SECTOR IDENTIFICATION: NORMALLY A SITE MONOPOLE WILL HAVE UP TO THREE SECTORS. SECTORS TRANSMISSION VBANDING SHALL BE DESIGNATED IN A CLOCKWISE LINE BRACKET MICROFLECT MANNER; THE ALPHA SECTOR IS CLOSEST MICROFLECT B1769 OR -\ - GROUND ELEVATION 302' TO ZERO DEGREES (NORTH) THE BETA B2336 OR EQUAL AND GAMMA FOLLOW CLOCKWISE IN EQUAL \ (N) CONCRETE---// ONCRETE (E) MONOPOLE SEQUENCE. S-1 PAD FOUNDATION TRANSMISSION ANTENNA AND COAXIAL CABLE SCHEDULE COAX ANTENNA AZIMUTH RAD COAXIAL CABLE COAXIAL CABLE MARK CENTER LENGTH ** J\' REVIEW A-1 rn L W 105' 135' (1} - 1-5/8" 0 c,4 RR65-19-OODP 0• a o w ®� o 00 a A-3 �C a 105 135' (1) - 1-5/8" 0 A-2 o m o 105' 135' (1) - 1-5/8" 4 RR65-19-OODP 0. z C:3= v U z I A-4 CD 105' 135' (1) - 1-5/8" 0 B-1 105' 135' (1) - 1-5/8" 0 RR65-19-OODP 120" C/) Q - B-3 105' 135' (1) - 1-5/8" 0 B-2 105' 135' (1) - 1-5/8" 0 RR65-19-OODP 120 3-4 105' 135' (1) - 1-5/8" 6 C-1 105' 135' (1) - 1-5/8" 0 RR65-19-OODP 240 C-3 105' 135' (1) - 1-5/8" 0 C-2 165' 135' (1) - 1-5/8" 0 RR65-19-OODP 240 C-4 105' 135' (1) - 1-5/8" 0 TOTAL LENGTH: 1620' ** ESTIMATED LENGTH CONTRACTOR TO FIELD VERIFY ALPHA SECTOR -RED BRACKET DETAIL BETA SECTOR -YELLOW GAMMA SECTOR - BLUE C-3 N.T.S. 4 COAX AND ANTENNA SCHEDULE 1 TOWER ELEVATION C-3 C-3 N.T.S. REVISIONS BY W \0 CONST. AD J\' REVIEW AD rn N ® Lr DRAWN BY: TT CHECKED BY VD/HM DATE 11/26/02 PLOT SCALE 1:1 DRAWING NAME 0-C3.dwg SHEET No. (\���/--��' �L / o W rn N ® rn L W Q cc x�� c,4 u a Ir a o w ®� o 00 a x cu �C a = a- u_ o m o a Lr DRAWN BY: TT CHECKED BY VD/HM DATE 11/26/02 PLOT SCALE 1:1 DRAWING NAME 0-C3.dwg SHEET No. (\���/--��' �L / o W o N W Q c,4 d' o ®� 8d cl� w o a z C:3= v U z I I CD z C/) Q J Lr DRAWN BY: TT CHECKED BY VD/HM DATE 11/26/02 PLOT SCALE 1:1 DRAWING NAME 0-C3.dwg SHEET No. (\���/--��' �L / o