Loading...
HomeMy WebLinkAboutZ-6560-A Map 18I TOWER SHOWN IS SCHEMATIC ONLYTINNED CU GROUND VIRE - CONNECT TO GROUND LOOP AT GROUND RODS CADWELD (TYPICAL) (CADWELD TO EACH TOWER GROUNDING LEADS FROM LEG - 3 LEADS TOTAL) ANTENNABL ES TO BE A CABLES ED BUSS BAR ---PROVIDE 2" x 14" COPPER GROUND BAR PER SPECS. OUTIINE EXISTING MOUNT BUSS BAR APPROX. TOWER 12'-0" ABOVE FI IISH GRADE CONNECT AS LOW PROVIDE ISOLATED CONNECTION AND AT EACH SET OF ANTENNA AS POSSIBLE FOR GROUND BAR GROUND LEADS. FINISH GRADE EXISTING TOWER GROUND LOOP _ lIIIIIII �I - Ilillilllll! ELECTRICAL POWER POLE PER DETAIL G" THIS SHEET. " CADWELD (TYPICAL) SEE SHEET 4 FOR LOCATION (METER TO BE READABLE THRU NOTES: TEST WELL (SEE DET. "C" THIS SHT.) ( 5 FENCE) GENERAL NOTES: —y-- ALL BENDS IN GROUNDING i I LEADS SHALL BE GRADUAL, 4 -� 1. CONTRACTOR SHALL PROVIDE #2 SOLID TINNED MINIMUM 8" TYPICAL COPPER WIRE 'GROUNDING LEADS" PER SPECS' SHELTER GROUND LEAD AT LOCATIONS INDICATED ON PLAN. ALL LEADS,' TOWER SHOWN IS SCHEMATIC SEE DET "E" THIS SHEET 6 3 EXTERIOR BLDG TO BUILDING GROUND SUBSYSTEM HALO GROUND HALO GROUND GROUND ROD AS PART -� ONLY. FOR SPECIFIC TOWER TYPE SEE SHEET 1. ATTACH LEAD TO GROUND RING 8 LOOP SHALL BE PART OF THE HALO GROUND SYSTEM GROUND BAR AND SHALL BE ATTACHED TO THE TOWER, SHELTER "D` LOOP LEADS OF HALO GROUND LOOP 2' I).. M► (TYP) NOTE: SCHEMATIC ONLY PER THIS DETAIL AND FENCE UPON COMPLETION OF THEIR CONSTRUCTION. SHEET SEE ELECTRICAL SHEET' - - ALL UNDERGROUND LEADS TO BE BURIED 2'-6" DEEP PER FOR MORE INFORMATION SEE SHEETS 4 & 6 FOR SPECS. LENGTH OF LEADS TO BE FIELD DETERMINED. AND LOCATION OF TOWER AT'T'ACH GROUND LEAD - FROM TOWER BASE TO AND EQUIPMENT SHELTER 2. PROVIDE GROUNDING LEAD FROM INTERIOR HALO FOUNDATION REBAR � - GROUNDING RING AT EA CORNER OF SHELTER. 4 REQ'D) ( CAGE (TYP.) / 2 g 3. PROVIDE GROUNDING LEAD FROM TELCO BOARD (1 REQ'D) A TOWER BASE GROUNDING_ B_ TYPICAL TOWER GROUND ' 1 4. PROVIDE GROUNDING LEAD FROM EXISTING TOWER, 7 NOT TOa ALE 7 NOT TO SCALE 5 5 8" x 8'-0" GROUND ROD PER 5. PROVIDE GROUNDING LEAD FROM POWER POLE. (1 REQ'D) TEST WELT. (SEE DET. C THIS SHEET) SPECS AT W-0" OC MAX. DRIVE 2'-6" MIN BELOW GRADE TYPICAL. 6. PROVIDE GROUNDING LEAD FROM EXTERIOR BUILDING GROUND BAR. (1 REQ'D) RF COAXIAL 7. PROVIDE GROUNDING LEAD FROM WAVE GUIDE BRIDGE. ATTACH TO WAVE GUIDE SUPPORTS AS REQ'D. (.1 REQ'D) PORT (TYP) 000 000 1z 000 8. PROVIDE GROUNDING LEAD FROM 200A PANEL BOARD - FINISH GRAD O O O O O O� (1 REQ'D) -- 000 000 PEEP GROUNDING 000 9. PROVIDE GROUNDING LEAD FROM INTERIOR MASTER GROUND BAR. (1 REQ'D) — VIII—!IIII IIIII�IIIII STRAPS (T`YP) = IIII- -IIIA- PMFG. IIII VIII= BAR PROVIDED C\I 8" x 2'-10" FVC SOIL. - PIPE WITH THREADED CAP ATTACH SANDWICH BUILDING PERIMETER GROUND LOOP I BAR 2'-r" BELOW FINISH GR� DE I I FIN. GRAip..; INTO .. GROUND LOOP VCQI� TOWER COMPOUND PL - ELECTRICAL / GROUNDING CADWELD HALO GROUND LEADS NOT TO SCALE ��---- -- CADWELD TO EA END �' OF SANDWICH BAR i_ �- GROUND ROD PER PLAN INSTALLATION INSTRUCTIONS ARE INCLUDED WITH "PEEP" KIT CONTRACTOR TO FOLLOW MFG'S SPECIFICATIONS C POLYPHASER EARTHED ENTRANCE PANEL I CQ C TEST WELL DETAIL D _EXTERIOR GROUNDING DEVICE CLASS 5 POLE ENTRANCE CAP ----/ (PER SPECS) 2 HOLE CONDUIT STRAPS AT T-0" OC TYPICAL PROTECTIVE CAPACITOR7 (PER SPECS) 0 TOWER LEG CADWELD y2 COPPER TO TOWER LEG BASEPLATE 1 200A METER BASE 0 (PER SPECS) 2" RIGID GALVANIZED CONDUIT CUT PVC ON CAULK — ANGLE TO MATCH FIN GRADE — _ _ _ M TOWER COMPOUND SURGE ARRESTOR (PER SPECS) I I (I h I FENCE 200A DISCONNECTSEiELTER 1/2" PVC PIPE ap (PER SPECS) 2 BARE TINNED SOLID j _ FINISH GRADE I I I I CADWELD (TYPICAL) -o., ( o 0ROUND CI/2 ROA OPLASTICCOVER / oao 0000 OO o o Do -I ( j— CQ O o I —I1 a h FjN[SH GRAD TAMPED II— I z _C12 �I CONCENTRIC c N EARTH _fl ll- RINGS 6" APART - I I TIE WIRE EACH e" 1 2" PVC COATED MIN IL ATTACH GROUNDING LEAD To GROUNDING 2 I I I CROSSING POINT 28 'PIES USE 2 (' ) N COPPER FOR CADWELD ALL CONNECTIONS UNDERGROUND (SEE GROUNDING 3'-0" I RIGID CONDUIT FOR SLAB PENETRATION LOCATION SEE SHEET 6 M BILE SYSTEM PER PLAN I SUPPORT SPEC FOR MORE INFORMATION) ##2 AWG BARE TINNED CU WIRE TO itfAINTAIN GROUND RING ONE ALLIED DRiVE Little Rock, Arkansas BOTTOM OF —1 5/8" DIA x 8'-0"-� GROUND ROD A 6" SEPARATION BETWEEN AND CONDUIT IF INSTALLED IN SAME GROUNDING LEAD TRENCH Office: (501) 905-8500 Fax: (501) 905-fi243 43 I i 0 LE NOTE: TYPICAL PROJECT: CHICOT RD. & MABELVALE CUTOFF, A2KANSAS . 42 42" OF ALL LEGS EXISTING MONOPOLE COLLOCATION E BUILDING GROUND DETAIL ELEVATION PLAN VIEW G POWER SERVICE ENTRANCE SHEET TITLE: ELECTRICAL/GROUNDING .. i NOT TO SCAL DESIGNEDBY: ALLTEL REVISIONS CELL BITE' 7 scALE: 3 4 =1 -0 SELF SUPPORT/ I� MONOPOLE c^ MSA DRAWN BY: ALLTEL GROUNDING CHECKED BY: SHEET NO. f�7�OT"FOUNDATION TO SCALE, woRkORDERNo. DATE: 08 SEPT 99 FILENAME 9907507 OF: 7