Loading...
HomeMy WebLinkAboutZ-6554-H Map 41weI:4►1�: -- BOUNDARY LINE ❑M EX. ELECT. METER -- -- RIGHT OF WAY LINE Q PROP. ELECT. METER ------ EASEMENT LINE _ _ = EXISTING CONCRETE CURB AND GUTTER 7 c EX. AIR CONDITIONER PROPOSED CONCRETE CURB AND GUTTER I EX. SIGNAGE PROPOSED FIRE LANE STRIPING EX. LIGHT POLE OHE OVERHEAD ELECTRIC UGE UNDERGROUND ELECTRIC 00 PROP. LIGHT POLE GAS GAS LINE GP o EX. BOLLARD UGT UNDERGROUND TELEPHONE EX. SS MANHOLE FO UNDERGROUND FIBER OPTIC © 8"SS SANITARY SEWER PROP. SS MANHOLE 8"W WATERLINE 4 EX. GAS METER ® BENCHMARK PROP. GAS METER b FIRE HYDRANT 0 EX. POWER POLE © EX. ELECT. MANHOLE Z WATER VALVE # PROP. POWER POLE Os EX. STORM MANHOLE "'MP EX. WATER METER PIT ❑ c EX. TELEPHONE PED. 0 EX. WATER METER OT EX. TELEPHONE MANHOLE MIM .1 PROP. INLETS (SEE GRADING PLAN FOR TYPE) PROP. WATER METER Q TSL EX. TRAFFIC SIGNAL LIGHTvs VERTICAL SEPARATION REQUIREMENT ®cv ce EX. SPRINKLER VALVE ® EX. TRAFFIC CONTROL BOX ® ®S EX. AUTO SPRINKLER P EX. FLAG POLE ` PROP. FIRE LANE EX. ELECT. PEDESTAL ® EX. YARD LIGHT \ ET ❑ EX. EL T. TR&NSFORMER © EX. GREASE TRAP F- PROP. FIRE HYDRANT PROP. 10" WATERLINE U O w Z N N PROP. FIRE HYDRANT 6„ 1 — 40 FIRE LANE STRIPING SHALL BE 6" RED BACKGROUND STRIPE WITH 4" INCH HIGH WHITE LETTERS USING %" STROKE STATING "FIRE LANE NO PARKING" OR "NO PARKING FIRE LANE" TO BE PAINTED UPON THE RED STRIPE EVERY FORTY (40) FEET ALONG THE ENTIRE LENGTH OF THE FIRE LANE. WORDING MUST BE GROUPED TOGETHER AS A PHRASE. FIRE LANE MARKING NOT TO SCALE — 0 GUARDRAIL t r- - IIIII� �� PROP. 10" WATERLINE i P_RELOCATEDj FIRE HYDRANT 300' FT. HOSE LAY i I 30�F HOSELAY' I — LIMITS OF CIVIL DESIGN. FOR COORDINATION WITHIN SOF THE BUILDING AND IN TYPICAL j BUILDING AREAS, SEE ARCH. PLANS. 250' FT HOSE LAY �FEl \300'FT. H SE LAY PROP. FDC — 300' FT. HOSE LAY' I PROP, FIRE HYDRANT I 300' FT. HOSE LAY WeIF01 HANK'S FURNITURE LOT 1, BOWMAN KANIS COMMERCIAL ADDITION P.B. I, PG. 120 ZONE PCD EX. FIRE HYDRANT TO BE RELOCATED PROP. FIRE HYDRANT I o PROP. FIRE LANE STRIPING (TYP) PROP. 10" WATERLINE 251,V1 NC SETBACK bD FIRE_— F EX � Q FIYDRANTC� < < — I 37E B13I N I j I I C M E MHoi 8" WATERLINE BL= I $�Iv I It1 — I WALL 45- Rfa w WI I I'I I I I I jl II EX FIRE I I HYDRANT III I EAST I I Ld 'I I I i S'' I oll� L9 I'I ® I I I I I I I I lu I I (I 0 I III Q I a l III 0 R I Q 'I I j I zl l I- 50, I I I III I III Om VIII � II III ' ' III III �� I I II III � I III I �IIN �i III I 91 EAST R.0 OH RHFAD Pumper Fire Truck Overall Length Overall Width Overall Body Height Min Body Ground Clearance Track Width Lock—to—lock time Max Wheel Angle FIRE CONTACT MR. DON BRADLEY ASSISTANT FIRE CHIEF LITTLE ROCK FIRE DEPARTMENT 624 CHESTER STREET LITTLE ROCK, AR 72201 PHONE: (501)918-3700 EMAIL: DBRADLEY@LITTLEROCK. ORG 480.67 Oft 7.745ft 0.656ft 8.167ft 5.00s 45.00' II N I N II o I i I z I f I N ,..-...°._"' 0�'F C R E y0 � G Q \(� O \�Q 91P �5�5 S ONE C A�� N SCALE IN FEET 0 40' 60' Bo' LOCATION MAP: R 13 W T O 1------------ N N PROJECT LOCATION (/\ NOT TO SCALE PROJECT: LOWE'V LITTLE ROCK, ARKANSAS PROJECT NUMBER: 15011 DRAWING DATE: 03.22.1E ISSUE DATE: 03.22.1E SEAL: SUBMITTAL: ISSUED FOR REVIEW REVISIONS: IT, _L, 1.11 4 THESE PLANS AND DRAWINGS ARE NOT TO B REPRODUCED CHANGED OR COPIED IN ANY FORI OR MANNER WHATSOEVER WITHOUT FIRS OBTAINING THE WRITTEN PERMISSION AND CONSEN OF CEDAR CREEK CONSULTING INC. THIS SHEET I NOT To BE USED FOR CONSTRUCTION UNLESS TH ISSUE DATE IN THE TITLE BLOCK COINCIDES WITH O' POST DATES THE DRAWING DATE. ANY CHANGE MADE FROM THESE PLANS WITHOUT CONSENT 0 CEDAR CREEK CONSULTING INC. AR UNAUTHORIZED, AND SHALL RELIEVE CEDAR CREE CONSULTING OF RESPONSIBILITY FOR AL CONSEQUENCES ARRIVING OUT OF SUCH CHANGE: DRAWING TITLE: FIRE PROTECTION PLAN SHEET: C1.03