HomeMy WebLinkAboutZ-6522-B Map 4NOTE : THE TOWER DRAWING IS ONLY A GRAPHIC REPRESENTATION OF THE STRUCTURE. THE ACTUAL TOWER IN THE FIELD MAY VARY. HATCH PENETRATION, SEE DETAIL 2/S-2 - ROUTE COAX. WITHIN EXISTING ACCESS TUBE, USE ACCESS TUBE EXPANSION BRACKETS ® 8'-0" O.C. MAX., (MTS PART NO. WT-EB60) RISER PENETRATIONS, SEE DETAIL 1/S-2 NEW COAX, CABLES ATTACHED TO EXISTING RISER WITH STAINLESS STEEL BANDING AND CABLE BRACKETS (TYP.) 8'-0" O.C. MAX. (MTS PART NO. RM-USBG) COAX CABLE LENGTH NOTE : ANTENNA ATTACHMENTS ARE DESIGNED TO MEET LOCAL BUILDING CODES AND ANSI EIA TIA-222-F STRUCTURAL STANDARDS FOR STEEL ANTENNA SUPPORTING STRUCTURES. THE DESIGN WINDSPEED IS 90 MILES PER HOUR. MAINTAIN 1't CLEARANCE FROM LADDER 1 TOWER ELEVATION TOWER NOTES PROPOSED T -MOBILE SECTOR ANTENNAS (TYP. 6) EXISTING ANTENNAS (TYP.) EXISTING 170' WATER TANK 1. FOR DETAILED TOWER INFORMATION REFER TO TOWER ERECTION DRAWINGS BY OTHERS. THE TOWER ON THIS SHEET IS SHOWN FOR GENERAL CONFIGURATION PURPOSES ONLY. 2. ANTENNA CONFIGURATION IS SUBJECT TO CHANGE. VERIFY ANTENNA HEIGHT, DOWN TILT, AND AZIMUTH WITH PROJECT MANAGER PRIOR TO CONSTRUCTION. r` d ANTENNA PIPE----,,--,-.DOWNTILT ASSEMBY REQUIRED FOR ALL PANEL TYPE ANTENNAS TNA/LNA COMBINER (OUTLETS TO FACE DOWN -VERTICAL) #6 SHIELD (MECHANICAL GROUND VIA ROUND MEMBER ADAPTER) No. 6 STANDARD GREEN INSULATED GROUND WIRE TO UPPER ANTENNA GROUND BAR (2 HOLE LUGS EA. END) JUMPER TO BE SECURED WITH 1/2" ANDREWS BUTTERFLY HANGERS W/1" STANDOFFS 1/2" COAX JUMPER-`� I II - RR65-19-OODP (MAX. LENGTH 4') I ANTENNA NOTE: ALL DOWNTILT, AZIMUTHS AND LNA'S TO BE VERIFIED BY RF TRANSMISSION6„ SITE DATA SHEET. SEE PROJECT LINES TO BTS MANAGER FOR INFORMATION. MIN. BIPOLAR PANEL ANTENNA L 1AND LNA MOUNTING DETAIL BACK OF BACK OF ANTENNA ANTENNA PORT 1 � PORT 2 PORT 1 � PORT 2 SLANT LT SLANT RT SLANT LT SLANT RT M M M M 1 /2 _,1 /2" 1 /2'� 1 /2" 3' 3' M M" F F LNA LNA t 6 F F _..- 6 M M---- 3'- 1/2" 1 /2'�_, - 3' F / F F� F M —M M — M 5 DUAL POLE EMS ANTENNA LAYOUT C-3 SCALE:NTS NOTE: DETAIL FOR SECTORS A (RED), B (YELLOW), AND G (BLUE) USING 12 LINES. (EXAMPLE SHOWN IS FOR SECTOR ONE) ANTENNA MOUNTING POSTS (MTS PART NO. WT -TMA -96) ATTACHED TO TANK TOP SURFACE WITH EPDXY ADHESIVE, ANCHOR TO RISER WITH SAFETY CABLE, SEE DETAIL 2/S-2 (4 R� (�ED) MAIN 10' A-1 I(1 RED) (3 RED) DIVERSITY J A-2 Ily I / �Pp • � BLUE) (1 BLUE) DIVERSITY J C_22��ii / ti! 'a z-1 (2 BLUE) L(4 BLUE) MAIN J EXISTING HANDRAIL I/ (4 YELLOW) �° (2 YELLOW) L MAIN B-1 .moo 8-2 (1 YELLOW) (3 YELLOW L DIVERSITY] i EXISTING ANTENNAS (TYP. 2) 3 ATYPICAL ANTENNA PLAN NOTE: ALL AZIMUTHS ARE REFERENCED TO MAGNETIC NORTH. w z Brookfield Corporate Center EXISTING AND ANTENNAS Suite 200 (TYP.) Greenville, S.C. 29607 ANTENNA MARK ¢ AZIMUTH Z Z COAX CABLE LENGTH COAX CABLE MECHANICAL DOWNTILT z EXISTING 170' WATER TANK 1. FOR DETAILED TOWER INFORMATION REFER TO TOWER ERECTION DRAWINGS BY OTHERS. THE TOWER ON THIS SHEET IS SHOWN FOR GENERAL CONFIGURATION PURPOSES ONLY. 2. ANTENNA CONFIGURATION IS SUBJECT TO CHANGE. VERIFY ANTENNA HEIGHT, DOWN TILT, AND AZIMUTH WITH PROJECT MANAGER PRIOR TO CONSTRUCTION. r` d ANTENNA PIPE----,,--,-.DOWNTILT ASSEMBY REQUIRED FOR ALL PANEL TYPE ANTENNAS TNA/LNA COMBINER (OUTLETS TO FACE DOWN -VERTICAL) #6 SHIELD (MECHANICAL GROUND VIA ROUND MEMBER ADAPTER) No. 6 STANDARD GREEN INSULATED GROUND WIRE TO UPPER ANTENNA GROUND BAR (2 HOLE LUGS EA. END) JUMPER TO BE SECURED WITH 1/2" ANDREWS BUTTERFLY HANGERS W/1" STANDOFFS 1/2" COAX JUMPER-`� I II - RR65-19-OODP (MAX. LENGTH 4') I ANTENNA NOTE: ALL DOWNTILT, AZIMUTHS AND LNA'S TO BE VERIFIED BY RF TRANSMISSION6„ SITE DATA SHEET. SEE PROJECT LINES TO BTS MANAGER FOR INFORMATION. MIN. BIPOLAR PANEL ANTENNA L 1AND LNA MOUNTING DETAIL BACK OF BACK OF ANTENNA ANTENNA PORT 1 � PORT 2 PORT 1 � PORT 2 SLANT LT SLANT RT SLANT LT SLANT RT M M M M 1 /2 _,1 /2" 1 /2'� 1 /2" 3' 3' M M" F F LNA LNA t 6 F F _..- 6 M M---- 3'- 1/2" 1 /2'�_, - 3' F / F F� F M —M M — M 5 DUAL POLE EMS ANTENNA LAYOUT C-3 SCALE:NTS NOTE: DETAIL FOR SECTORS A (RED), B (YELLOW), AND G (BLUE) USING 12 LINES. (EXAMPLE SHOWN IS FOR SECTOR ONE) ANTENNA MOUNTING POSTS (MTS PART NO. WT -TMA -96) ATTACHED TO TANK TOP SURFACE WITH EPDXY ADHESIVE, ANCHOR TO RISER WITH SAFETY CABLE, SEE DETAIL 2/S-2 (4 R� (�ED) MAIN 10' A-1 I(1 RED) (3 RED) DIVERSITY J A-2 Ily I / �Pp • � BLUE) (1 BLUE) DIVERSITY J C_22��ii / ti! 'a z-1 (2 BLUE) L(4 BLUE) MAIN J EXISTING HANDRAIL I/ (4 YELLOW) �° (2 YELLOW) L MAIN B-1 .moo 8-2 (1 YELLOW) (3 YELLOW L DIVERSITY] i EXISTING ANTENNAS (TYP. 2) 3 ATYPICAL ANTENNA PLAN NOTE: ALL AZIMUTHS ARE REFERENCED TO MAGNETIC NORTH. 4 '� ANTENNA SCHEDULE COAX CABLE INDE 'IFICATION NOTE: CONTRACTOR MUST PROVIDE EASY IDENTIFICATION AND UNIFORM MARKING OF ANTENNA LABELING, PER THE FOLLOWING INSTRUCTION. 1. LOCATION: MARKINGS SHALL BE MADE USING COLOR TAPE W/3" OF COVERAGE AFFIXED AT THREE PLACES ON THE COAX CABLE RUN AS FOLLOW: FIRST - ON THE COAX AT THE CONNECTOR NEAREST THE ANTENNA (WHERE THE COAX AND JUMPER ARE CONNECTED) SECOND - AT THE BASE OF THE TOWER STRUCTURE (FOR TOWERS ONLY) THIRD - AT A POINT OUTSIDE THE BTS (JUST PRIOR TO MGB) 2. SECTOR IDENTIFICATION: NORMALLY A SITE WILL HAVE UP TO THREE SECTORS. SECTORS SHALL BE DESIGNATED IN A CLOCKWISE MANNER; THE ALPHA SECTOR IS CLOSEST TO ZERO DEGREES (NORTH), THE BETA AND GAMMA FOLLOW CLOCKWISE IN SEQUENCE. ALPHA SECTOR - RED BETA SECTOR - YELLOW GAMMA SECTOR - BLUE CarterABurgess CARTER & BURGESS, INC. Brookfield Corporate Center ANTENNA AND COAXIAL CABLE SCHEDULE Suite 200 Greenville, S.C. 29607 ANTENNA MARK ANTENNA AZIMUTH RAD CENTER COAX CABLE LENGTH COAX CABLE MECHANICAL DOWNTILT A-1 RR65-19-OODP PROFESSIONAL 10' 171' TBD' (2) 1 5/8" 0 0' A-2 RR65-19-OODP dP O 10' 171' TBD' (2) 1 5/8" 0 0' B-1 RR65-19-OODP ......................... W 130' 171' TBD' (2) 1 5/8" 0 0' B-2 RR65-19-OODP 130' 171' TBD' (2) 1 5/8" 0 0' C-1 o� QinLU RR65-19-OODP 230' 171' TBD' (2) 1 5/8" 0 0' C-2 r RR65-19-OODP C&B JOB NUMBER: 1 230' 1 171' TBD' (2) 1 5/8" 0 1 0' * FUTURE ANTENNAS A ISSUE FOR REVIEW 10/08/02 I TOTAL LENGTH = TBD' ** ESTIMATED LENGTH - CONTRACTOR TO VERIFY 4 '� ANTENNA SCHEDULE COAX CABLE INDE 'IFICATION NOTE: CONTRACTOR MUST PROVIDE EASY IDENTIFICATION AND UNIFORM MARKING OF ANTENNA LABELING, PER THE FOLLOWING INSTRUCTION. 1. LOCATION: MARKINGS SHALL BE MADE USING COLOR TAPE W/3" OF COVERAGE AFFIXED AT THREE PLACES ON THE COAX CABLE RUN AS FOLLOW: FIRST - ON THE COAX AT THE CONNECTOR NEAREST THE ANTENNA (WHERE THE COAX AND JUMPER ARE CONNECTED) SECOND - AT THE BASE OF THE TOWER STRUCTURE (FOR TOWERS ONLY) THIRD - AT A POINT OUTSIDE THE BTS (JUST PRIOR TO MGB) 2. SECTOR IDENTIFICATION: NORMALLY A SITE WILL HAVE UP TO THREE SECTORS. SECTORS SHALL BE DESIGNATED IN A CLOCKWISE MANNER; THE ALPHA SECTOR IS CLOSEST TO ZERO DEGREES (NORTH), THE BETA AND GAMMA FOLLOW CLOCKWISE IN SEQUENCE. ALPHA SECTOR - RED BETA SECTOR - YELLOW GAMMA SECTOR - BLUE CarterABurgess CARTER & BURGESS, INC. Brookfield Corporate Center 201 Brookfield Parkway Suite 200 Greenville, S.C. 29607 (864) 329-8500 i S(ATE OF X10, ARAA AS REGISTERED PROFESSIONAL ENGINEER L!p NO. 10534 � <<S.HLi1 �......, ......................... ............. 0F AV y.., T . dP O 8 •...........• ......................... W Y C0 N WC W Hao~Z W NWcna0 V oH_ cno�zQvY r Q��YOcn o� QinLU J LV aO J m IL m J r C&B JOB NUMBER: 350099.011.1 DATE ISSUED: 10/16/02 INITIAL ISSUE ISSUES/REVISIONS: A ISSUE FOR REVIEW 10/08/02 0 INITIAL ISSUE 10/16/02 1 REVISED PER 10/23/02 OWNER COMMENTS SHEET CONTENTS: TOWER ELEVATION AND ANTENNA DETAILS SHEET NUMBER: C-3 0.0 COPMGHT®2002 by Carter 8 Burgess, Inc Wd 9b 9Z 9 Z018ZlDl -X110-M-M