Loading...
HomeMy WebLinkAboutZ-6275-D Map 1t GENERAL NOTES � —1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: g CONTRACTOR - BECHTEL s SUBCONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) OWNER - AT&T WIRELESS SERVICES. 2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND PROJECT '- SPECIFICATIONS. 3. DRAWINGS PROVIDED HERE ARE NOT TO BE SCALED AND ARE INTENDED TO SHOW OUTLINE ONLY. $ 4, ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE a CODES. REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES F AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY g PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK, ALL WORK SHALL COMPLYMUNICIPAL AND UTILITY COMPAN i SPECIFICATIONSRIED AND OUT CL JURISDICTIONALITCODES,ALLAORDINANCES ANO APPLICABLE R GE ULATIO SY 5 UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. i WITH ¢ 6. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE L MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 7, IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE CONTRACTOR. % 8. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDscAPING THE SATISFACTION OF OWNER. ED PART SHALL BE REPAIRED AT SU8CONTRACTOR'S EXPENSE 9. THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. e 10, ALL -EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER DifLITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES. AND WHERE'REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE SUBCONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND # OR NEAR UTILITIES. SUBCONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. € THIS WILL INCLUDE BUT NOT 9E LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING & EXCAVATION. 11. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES. WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK. AS DIRECTED BY THE RESPONSIBLE ENGINEER, AND SUBJEC-17 TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 12 QI.UMENT OR . RIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABTHE WORK AND NOT ILIZED TOWER, THE AREAS OF THE OWNER'S PROPERTY DISTURBED DTO PREVENT EROSION. 13, SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION. SHALL BE IN CONFORMANCE WITH THE LOCAL. GUIDELINES FOR EROSION AND SEDIMENT CONTROL 14 FILL OR CELSNOT BEPLACED SHALL MATE-MAL HN ANY FILLED ON FROZEN OR EMBANKMENT. FROZEN MATERIALS, SNOWOR 15. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION_ 16, THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE BTS EQUIPMENT AND TOWER AREAS. n 0 � 17, IF NEGESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL B REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. w 18. THE SUBCONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE. z m 19. SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. r in w z Uj PROJECT INFORMATION SCOPE OF WORK: UNMANNED TELECOMMUNICATIONS FACILITY MODIFICATIONS SITE ADDRESS: 2700 BOOKER STREET 0 LITTLE ROCK, AR 72203 LATTITUDE: 34' 43' 33.16" N (NAD83) LONGITUDE: 92- 18' 27.61" W (NAD83) JURISDICTION: CITY OF LITTLE ROCK, PULASKI COUNTY CURRENT USE: TELECOMMUNICATIONS FACILITY PROPOSED USE: TELECOMMUNICATIONS FACILITY DRAWING INDEX REV 24897-LTRO07-01 TITLE SHEET 0 24897-LTRO07-02 EQUIPMENT LOCATION PLAN 0 24897-LTRO07-03 NOTES 0 24897-LTRO07-04 ANTENNA CONFIGURATION 0 24897-LTRO07-04A RF NOTES AND BILL OF MATERIALS 0 24897-LTRO07-05 FOUNDATION NOTES AND DETAILS 0 24897-LTRO07-06 POWER AND GROUNDING SCHEMATIC 0 24897-LTRO07-07 GROUNDING DETAILS 0 24897-LTRO07-08 ALARM ASSIGNMENT DETAILS -- 0 24897-LTRO07-09 DETAILS 0 24897-LTRO07-10 TOWER ELEVATION 0 VICINITY MAP TAKE 1-630 EAST TO UNIVERSITY, GO SOUTH ON UNIVERSITY TO ASHER, GO EAST .ON ASHER UNTIL INTERSECTION WITH ROOSEVELT, VEER RIGHT ONTO ROOSEVELT TO BOOKER, SITE WILL BE ON THE LEFT AT&T AT&T WDiELF.58 '00 S. p — wrrc so y n MKV6 ]1741 3 E D —� ❑ L'- LU u � c J �.� C ,.t AT&T WIRELESS cz c � o SITE NUMBER: LTRO07 C SITE NAME: ROOSEVELT � . a. > �, ro Z � co M a ¢ (n APPLICABLE BUILDING CODES SITE NAME. ROOSEVELT , CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. o' D E A NEW YORK DALLAS , SITE NUMBER. LTRO07 fL Y N C H 4230 LEI Freeway, Suite 625, Dallas, TX 75244 C v 2700 BOOKER STREET R \y ` 1 tel 972.239.6100 fax 972.239.6102 LITTLE ROCK, AR 72203 0 1 ABBATT1STA w .Olacexom CONCRETE_ AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, Ld r NINTH EDITION TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222-F, STRUCTURAL STANDARD FOR CONSULTING ENGINEERS STRUCTURAL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH _ RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM 4 A 1 5 j AT&T AT&T WDiELF.58 '00 S. p — wrrc so y n MKV6 ]1741 3 E D —� ❑ L'- LU u � c J �.� C ,.t AT&T WIRELESS cz c � o SITE NUMBER: LTRO07 C SITE NAME: ROOSEVELT � . a. > �, ro Z � co M a ¢ (n APPLICABLE BUILDING CODES SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL , CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF , CONTRACT AWARD SHALL GOVERN THE DESIGN. BUILDING CODE:* STANDARD BUILDING CODE (SBC), 1997. C v ELECTRICAL CODE: NATIONAL. FIRE PROTECTION ASSOCIATION (NEPA) 70-2002 NATIONAL ELECTRICAL CODE. R \y LIGHTNING PROTECTION CODE: 1 NFPA 101 - 2003, UNIFORM FIRE CODE V SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS. AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE_ AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, NINTH EDITION TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222-F, STRUCTURAL STANDARD FOR STRUCTURAL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1I00 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC EQUIPMENT IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION CATEGORY "C3" AND "HIGH SYSTEM EXPOSURE") B TIA 607 COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS TELCORDIA GR -63 NETWORK EQUIPMENT -BUILDING SYSTEM (NESS): PHYSICAL PROTECTION TELCORDIA GR -347 CENTRAL OFFICE POWER WIRING TELCORDIA GR -1275 GENERAL INSTALLATION REQUIREMENTS TELCORDIA GR -1503 COAXIAL CABLE CONNECTIONS FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. A 03/n/04ISSUED FOR REAEW NO. DATE RENSIONS BY I CHK P' SCALE: AS SHOWN DESIGNED BY JHR DRAWN BY: DS 2 108g4 J A D.L.A. PROJECT NUMBER, TBECO341 TASK 007 TITLE SHEET sae xo. art Ha Bv�wac >nn+Bae IVLv 24897 LTRO07 01 A � 1l : 11 U 51It Psi_ I � s z 7 s` 9 a W Z W t O' D E A I NEW YORK • DALLAS L Y N C H 4230 L R; F,cc-o y, Suite 625, Dolcs, TX 7524A tel 972.239,6100 Tax 972.239.6102 c0i A B B A T T I S T A www.oloce.com W m CONSULTING ENGINEERS 6 f 5 SITE NAME: ROOSEVELT SITE NUMBER, !_T.ROU7 2700 BOOKER _5'REET LITTLE ROCK, AR ?2263 _ N AT&T WIREL856.� • 40n 5:�,-RSV,"JvSjiE�,'bOG'• -EXISTING ANTENNAS TO REMAIN -EXISTING ANTENNAS TO REMAIN -EXISTING ANTENNA PLATFORM '(6)—EXISTING ANTENNAS TO BE REPLACED W/ (6) NEW OLIADPOLE ANTENNAS AT 120'-0" A.G.L. (TYP 2 PER SECTOR) EXISTING ANTENNAS TO REMAIN vasnNG 150'-0' MONOPOLE TOWER 0 I I f TOWER ELEVATION SCALE N.T.S. A 00/22/04 ISSUED FOR REVIEW REVISIONS or CHK We SCIV. F• AS SHO' >aESIGNW FN: I.R. DRAWN ED': 05 2 NOTE NO STRUCTURAL ANALYSIS HAS BEEN PERFORMED BY O'DEA, LUNCH ABBATTISTA CONSULTING ENGINEERS, PC. TO VERIFY THE CAPACITY OF THE TOWER WITH THE PROPOSO NEW ANTENNA LOADS. CONSTRUCTION SHALL NOT PROCEED UNTIL ANALYSIS HAS BEEN PERFORMED. I C C 1.9 A O.L.A. PROJECT NUMBERr TBECO341 TASK 007 TOWER ELEVATION Joe N0. sm w on" In CJI ACV 24897 LTRO07 10 A T 11 z 1 a I e n 0 0 e— J W CONSTRUCTION NOTES m. Z1. FIELD VERIRCATJON: SUBCONTRACTOR SHALL FIELD VERIFY SCOPE OF WORK, AT&T ANTENNA PLATFORM LOCATION Uj H AND ANTENNAS TO BE REPLACED. In 2. COORDINATION OF WORK. SUBCONTRACTOR SHOULD COORDINATE RF WORK AND PROCEDURES WITH CONTRACTOR. 1 r 3. CABLE LADDER RACK: W SUBCONTRACTOR SMALL FURNISH AND INSTILL CABLE LADDER RACK, CABLE TRAY, AND CONDUIT AS REOUIRED TO SUPPORT CABLES TO THE NEW BTS - C:ATION. 0 0 0 z z L) Ln ^!'DEA 1 NEW YORK - DALLAS L Y N C H 42310 LBI FNeewoy, Suite 625, Dallas, TX 75244 ntel 972.239.6100 fox 973.239.6102 L) A B B A T T I S T A www.oloce.com m CONSULTING ENGINEERS 6 5 EXISTING CABINET NEW COI NEW C01 RELOCAT ULTRASIT NEW NO CABINET NEW COI EXTENSK SHEET C NEW NOI SUPPOR' EXISTING POWER/TELCO SERVICE BACKBOARD SITE NAME ROOSEVELT SITE NUMBERS LTRO07 2700 BOOKER STREET LITTLE ROCK, AR 72203 4 AT&T •T WIRELESS 900 is. _ owniim mmi SUITE 600 iTTNL acm AWANMS MIM 3 EXISTING MONOPOLE EXISTING ICE BRIDGE EXISTING BUILDING EQUIPMENT LOCATION PLAN SCALE: N.T.S. NOTE: CONTRACTOR TO FIELD ROUTE NEW ELECTRK'JU. AND TELCO CONDUITS FROM NEW : EQUIPMENT CABINETS TO TELCO EIJCLOSURE AND TO DESIGNATED ELEC SOURCE PER ONE—UNE DIAGRAM. A O]/27/W 6SUED FOR REHEM PATE REVISIONS BY CHK ti SCALE AS SHOWN DESIGNED BY: Ji DRAWN BY: DS 2 ,I—A. PROJECT NUMBERm TEECO341 TASK 007 EQUIPMENT LOCATION PLAN ,Ipg eq, SOC Nu. WA—G N—eax jNCV 24897 LTRO07 02 A ID C A EXISTING CONCRETE PAD EXISTING LUCENT TDMA EQUIPMENT CABINETS EXISTING LUCENT 24V DC LOW- POWER POWERPLANT EQUIPMENT LOCATION PLAN SCALE: N.T.S. NOTE: CONTRACTOR TO FIELD ROUTE NEW ELECTRK'JU. AND TELCO CONDUITS FROM NEW : EQUIPMENT CABINETS TO TELCO EIJCLOSURE AND TO DESIGNATED ELEC SOURCE PER ONE—UNE DIAGRAM. A O]/27/W 6SUED FOR REHEM PATE REVISIONS BY CHK ti SCALE AS SHOWN DESIGNED BY: Ji DRAWN BY: DS 2 ,I—A. PROJECT NUMBERm TEECO341 TASK 007 EQUIPMENT LOCATION PLAN ,Ipg eq, SOC Nu. WA—G N—eax jNCV 24897 LTRO07 02 A ID C A