HomeMy WebLinkAboutZ-6240-B Map 11GRAPHIC I E
CONTROLLER NOTES:
1. MOUNT CONTROLLER
ON OUTSIDE WALL OF
BUILDING.
2. MOUNT RAIN SENSOR
ON EAVE OF BUILDING.
3. IRRIGATION
CONTRACTOR TO VERIFY
POWER TO CONTROLLER
(ONE (1) - `I VMC: lbw. `
SOURCE PER:"
CONTROLLER):;;
tI
IN
F.F.E. = 429.00
m w m
° -' t. K - '
5 3/4" PVC STUB UP FOR l
CZ100 )i" FLEXIBLE 2 1 3
DISTRIBUTION TUBE 1" CZ100
4.20 ` CONNECTION, 9.50 7.94 CZ100
TYPICAL - SEE 9.57
z.DETAIL 'I IPI
Nk
,.i
5,
a
i
:
:s
'.;--
>
s 4"
,. is i . n t ^^ ; L,... ;/ ) / ^ • 3/ ,
S
/
r
3 4
S t
INN
6
...._................................................_.._..........._......_..........................._...._..................__..__._...__............_............. .....................:•
4 POINT OF CONNECTION
CZt00 SET NEW 1" TAP AND METER. J9a
I
SERVICE LINE TO METER TO BE
8 fi4 1" MINIMUM (POLY OR PVC)
...........:................
..........
. ..........
..
IRRIGATION NOTES: -----------
1. LOCATE ALL UTILITIES BEFORE DIGGING. PROTECT ALL UTIU11ES FROM DAMAGE DURING CONSTRUCTION.
2. PIPE ROUTING IS DIAGRAMMATIC. PLACE IRRIGATION LINES WITHIN PLANTING AREAS UNLESS SLEEVING IS INDICATED. ROUTE PIPING TO AVOID TREE LOCATIONS.
LOCATE MAINLINE AND VALVE BOXES WITHIN PROPERTY LINES.
3. SYSTEM IS DESIGNED TO OPERATE AT 10 GPM AT 60 PSI.
4. PROCURE ALL NECESSARY PERMITS TO COMPLETE INSTALLATION OF IRRIGATION SYSTEM PER STATE AND LOCAL CODES.
5. JET OR BORE FOR SLEEVING WHERE NECESSARY TO ACCOMMODATE LATERAL LINES, MAIN LINES, OR CONTROL WIRE.
6. PROVIDE A MINIMUM 8" COVER OVER LATERAL LINES AND A MINIMUM OF 12" COVER OVER MAINLINES.
7. INSTALL ALL ELECTRICAL SERVICE TO MEET LOCAL CODES.
8. INSTALL VALVES IN MEDIUM RECTANGULAR BOXES WITH TAMPER RESISTANT LIDS.
9. ALL IRRIGATION CONTROL WIRE TO BE 14 -GAUGE WIRE, PROVIDE WHITE FOR COMMON, RED FOR HOT, AND A SPARE BLUE WIRE PARALLEL TO COMMON
THROUGHOUT THE ENTIRE SYSTEM.
10. MAKE ALL WIRE SPLICES WITH WATERPROOF SPLICE KITS RATED FOR DIRECT BURIAL NEATLY COIL 30" OF SLACK WIRE IN VALVE BOX.
11. PROVIDE PRESSURE COMPENSATING DRIP EMITTERS FOR ALL TREES, SHRUBS, AND GROUNDCOVERS. SEE CHART FOR EMITTER SIZE AND QUANTITY.
SECTION VIEW
MAINLINE, LATERAL, MAINLINE LATERAL WIRING IN
AND WIRING IN PIPE PIPE CONDUIT
THE SAME TRENCH
WIRE W/O CONDUIT
RUN WIRING BENEATH ALL SOLVENT WELD-' TIE A 24 -INCH LOOP IN
AND BESIDE MAINLINE. PLASTIC PIPING TO ALL WIRING AT CHANGES
TAPE AND BUNDLE AT BE SNAKED IN OF DIRECTION OF 30'
10 -FOOT INTERVALS. TRENCH AS SHOWN. OR GREATER. UNTIE
AFTER ALL CONNECTIONS
HAVE BEEN MADE.
5 PIPE & WIRE
IPI SCALE: N.T.S.
BUG CAP
RAIN BIRD DBC -025
Y4" TUBING STAKE
RAIN BIRD TS -025
Y4" DISTRIBUTION TUBING
RAIN BIRD DT -025
TOP OF MULCH
SELF -PIERCING BARB CONNECTOR
RAINBIRD XB-xx OR PC-xx
Ys" DISTRIBUTION TUBING
TORO AG BLUE STRIPE TUBING
FINISH GRADE
NOTE:
1. USE RA!tr BIRD BUG GUN (MODEL EMA-'{/BGX) OR XERIMAN TOOL (MODEL XM -TOOL) TO
INSERT BARB CONNECTOR DIRECTLY INTO /j" DISTRIBUTION TUBING.
r
4�DRIP COMPONENT DETAIL
SCALE; N.T.S.
e
•
•
EMITTER SIZING CHART
GALLON
SIZE
QUANTITY &
GPH EMITTER
1 GAL. & UNDER
1 ® 1.0 GPH
3 GAL.
2 0 2.0 GPH
7 GAL. - 15 GAL
2 0 7.0 GPH
30 GAL & UP
2 0 12.0 GPH
PALMS
12 0 7.0 GPH
CAP (TYPICAL)
+- PAVING
18" MIN. F-
24"' MIN. TO
FINISH GRADE
.
K,
18" MIN.
24",MAX.
CAP
NOTES:
1. ALL PVC IRRIGATION SLEEVES TO BE SCHEDULE 40 PIPE.
2. ALL JOINTS TO BE SOLVENT WELDED AND WATERTIGHT.
3. WHERE THERE IS MORE THAN ONE SLEEVE, EXTEND THE SMALLER SLEEVE
TO 24 -INCHES MINIMUM ABOVE FINISH GRADE.
4. MECHANICALLY TAMP TO 957a PROCTOR.
\SLEEVING DETAIL
P1 /SCALE: N.T.S.
DRIP VALVE
W-11
IRRIGATION SCHEDULE
( IN T'Ela"P )
I inch =, 30 St.
ZONING: 0-3 GENERAL OFFICE WITH
CONDITIONAL USE (CASE ##Z -6240-B)
IRRIGATION LEGEND
-- SCH. 40 MAINLINE,
1.
CLASS 200 LATERALS,
3/4"
® 3CH. 40 SLEEVE,
1 ZONE NUMBER
1-1/2" VALVE SIZE
L 35 J GALLONS PER MINUTE
QUANTITY
KEY
MODEL (RAINBIRD UNLESS OTHERWISE NOTED)
4
® XCZ
1" DRIP VALVE KIT
XCZ-100
H-" a n d
1" ELECTRIC REMOTE CONTROL VALVE
1
PGA -100
1
1-1/4" BACKFLOW PREVENTER
_
FEBCO 825Y
19
�
1400 SERIES BUBBLER .5 GPM AT 30 PSI
1®
8 STATION BASE CONTROLLER
ESPLXM
1
A
MINI-CUK RAIN SENSOR
PVC SCH 40 ELL
PVC SCH 40 COUPLING
30 -INCH LINEAR LENGTH OF
WIRE, COILED
WATER PROOF CONNECTION
(1 OF 2)
ID TAG
VALVE BOX WITH COVER
PVC SCH 80 NIPPLE (CLOSE)
-f-TOP OF MULCH
-a--FINISH GRADE
3" MIN PVC SCH 80 UNION FOR
SERVICING ASSEMBLY
PVC SCH 40 MALE ADAPTER
LICK (1 OF 4)
IC MAINLINE
)NTROL ZONE KIT: RAIN BIRD
MODEL XCZ-xxx
D -INCH MINIMUM DEPTH OF
3/4 -INCH WASHED GRAVEL
fC SCH 80 NIPPLE (LENGTH
AS REQUIRED, 1 OF 2)
fC SCH 40 TEE OR ELL
fC SCH 80 NIPPLE (2 -INCH
LENGTH, HIDDEN) AND
PVC SCH 40 EU_
LINE CONNECTION DETAIL
3/4» - 1,-0»
TERMINATING REDUCING ELL
WITH 1/2" THREADS
MULCH
MIDSTREAM TEE WITH TWO 1/2"
THREADED REDUCER BUSHINGS
BARB FOR DRIP LINE CONNECTION
(TORO EZ DRIP 1/2" MALE ADAPTER
##FMA -050)
FLEXIBLE DRIP LINE
BEGINNING REDUCING ELL
WITH 1/2" THREADS
EXISTING SUBGRADE
SUPPLY LINE FROM VALVE
(DEPTH OF COVER TO MATCH
LATERAL LINE SPECIFICATIONS,
SIZE PER PLAN)
NOTE: DO NOT EXCEED
A 50' RUN OF FLEXIBLE
DRIP LINE WITHOUT
ADDING A MIDSTREAM
SUPPLY STUB.
TEN N ESSEE
ESIGN
H-" a n d
NGINE.ERING
I Ne ARCHITECTS
STRUCTURAL AND CIVIL ENGINEERS
_
5105 Maryland Way Suite 200
Brentwood , Tennessee 37027
615.370-1779 fax: 370-9108
www.dandeint.us
-
WREDCID_
ED
�r 40n
La mf*
V
z
a_
z
V)
00
W z
8Q
a
'' E
z
x
i
Job Nintiff:
67-0080
Fbvidom
02/21/08 PER NEW BASE
7
Irr'
,
S �` „