HomeMy WebLinkAboutZ-6178-K ApplicationO'pzd.duc
APPLICATION FOR
PLANNED ZONING DEVELOPMENT - SHORT FORM
03/01/10
CASE FILE NO. Z- 6
PLN
A,' NG OMNVSSION MEETING DOCKETED FOP, `��
tit t. ,-p.m.
Application is hereby made to the Board of Directors of Little Rock, Arkansas through the Planning
Commission pursuant to Arkansas law on City planning, Act 186 of 1957, Acts of Arkansas, and Section
36 of the Little Rock Code of Ordinances as amended, petitioning for classification of the following
described area as a Short Form Planned 'Zoning DeNvIupn>,ent.
Legal
Tide to this property is vested in: L �L
If an individual other than the title holder tiles this application, attachment of a letter is required
authorizing this person to act on behalf of the title holder.
It is desired that the boundaries shown on the Districtbe amended and that this area be amended
-.
and t at this area Lid rue tixstrd from the present lll �._ District
to.[.L District.
Present Use of Property: r�
Desired Use of Property:
It is understood that notice of the public hearing hereon before the Little Rock Planning Commission
will be published at least fifteen (15) days prior to said hearing in a daily newspaper as required by Act
186 of the 1957 Acts of Arkansas and Section 23 of said Ordinance, and that notice of preliminary
hearing before the Commission must be circulated by the applicant u, all other parties in interest,
including owners of land within 200 feet of the boundary of the area under consideration as required by
the rules of the Commission, and that the cost of these notices shall be borne by the applicant. }�
(OWNER I.��4 (�t]•�c� V tkACk4,e_ -tMAIL ADDRESS: 0 l It -t-V
or (AGENT) HOME PHONE: �� ( �{ I I. `►�� �'fl$
BUSINESS PHONE:? of " fle fl
FILING FEE: P.C. APPROVED:
Collectors P.C. I)E4\1 IED: ---+
w 0 paid stamp BD. OF DIR. APPROVED: 14
here ORDINANCE titer r� �..f Al
Signature of SecrelarV i� C ornnnsstan or
Authorized Agent V
sfpzd.doc
INFORMATION SHEET FOR
SUBDIVISION PZD's ZONING
OR SUBDIVISION SITE 6AN REVIEWS
ITEM NO. DATE
FILE NO. Z " 4c: � l � y i
NAME: 1. Vr L.LL Gl &I 1 �� �� �C l�
C '} 7
LOCATION: I
03/01/10
DEVELOPER:
STREET ADDRESS
CITY/STATE/ZIP
TELEPHONE NO.
ENGINEER:
STREET ADDRESS
CITY/STATE/ZIP
TELEPHONE NO.
AREA NUMBER OF LOTS
FT. NEW STREET
ZONING PROPOSED USES
PLANNING DISTRICT CENSUS TRACT
VARIANCES REQUESTED
1.)
2.)
3.)
4.)
Moses Tucker Partners
Department of Planning and Development
723 West Markham
Little Rock, Arkansas
501-371-4790
RE: Rezoning Application (Short -Form) for Lot 1 at 9222 Stagecoach Road
To whom it may concern,
This letter is to serve as the cover letter supplement to the PZD rezoning application for Lot 1 located at
9222 Stagecoach Road in Pulaski County, Little Rock, Arkansas.
The development rationale for this property is to use the existing structure for multi -tenant use, which
would include a Papa John's restaurant, and additional space for light commercial or retail use. The
current zoning of the property is MOD, and the Planned Use of the property is MX.
Attached with this cover letter is the following:
• Legal description of Lot 1
• 2014 survey of Lot 1
• Existing site plan that shows existing state of the Lot 1 and surrounding land
■ Rezoing PZD Short -Form Application
• Affidavit from current property owner
No proposed changes to the property are requested, except for the change in use to include restaurant
and light retail.
Eric Nelson
Newmark Moses Tucker Partners
Senior Commercial Agent
200 River Market Avenue, Suite 501 Little Rock, AR T 501.951.1802
www.newmarkmtp.com Independently owned and operated
sfpcd.doe
AFFIDAVIT
L Y-1 ►� _ _ certify by my signature below that l herehv
authorize
Property described as:
Signature of Title Ho dcr
yG t•oCy[[.�+��-
Suhscr:hed and sworn to me a 4'otary Puhlic on this
KATHY J. NORMAN
Notary Public -Arkansas
Saline County
My Commission Expires 04-03.2027
CommltflQn 0 12700550
My Commission Expires:
to act as my agent regarding the
of the below described property.
It -5, I
Date
I/1
day of
Not• Public
03/01/10
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
July 6, 2018
Eric Nelson
Newman Moses Tucker Partners
200 River market Avenue Suite 501
Little Rock, AR 72201
Re: Z -6178-K - Stagecoach Village Lot 1 Revised Short -form POD, located at
9222 Stagecoach Road
Dear Sir or Madam:
Enclosed please find a copy of an Ordinance adopted by the Board of Directors at their
June 19, 2018, Public Hearing approving the above referenced development.
If you have any questions concerning this ordinance, please feel free to call me at 371-
6821.
Sincerely,
Donna James, AICP
Subdivision Administrator
IIIIIIIIIII�IIIII�II�I�IIII��IIIII�II�II 2018038319
PRESENTED: M20-201810:02:37 AM RECORDED: 06-20-201810:05:07 AM
In Official Records of Larry Crane Circuit/County Clerk
1 ORDINANCE NO. 21,593 PULASKI CO, AR FEE $20.00
2
3 AN ORDINANCE TO APPROVE A PLANNED ZONING DEVELOPMENT
4 AND ESTABLISH A PLANNED OFFICE DISTRICT TITLED
5 STAGECOACH VILLAGE LOT 1 REVISED SHORT -FORM POD,
6 LOCATED AT 9222 STAGECOACH ROAD (Z -6178-K), LITTLE ROCK,
7 ARKANSAS, AMENDING THE OFFICIAL ZONING MAP OF THE CITY
8 OF LITTLE ROCK, ARKANSAS; AND FOR OTHER PURPOSES.
9
10 BE IT ORDAINED BY THE BOARD OF DIRECTORS OF THE CITY OF LITTLE ROCK,
11 ARKANSAS.
12 Section 1. That the zoning classification of the following described property be changed from Revised
13 POD, Planned Office Development, to Revised POD, Planned Office Development:
14
Z -6178-K: Part of the N V2, NE %, Section 5, T -1-S, R -13-W, Little Rock, Pulaski
F1111 ,
15
�,oWI
�i
County, Arkansas, more particularly described as: commencing at the southwa l I- CUi
16
corner of the N'/s, NE 1/4, of said Section 5; thence NO2°24'49"E along the west line � u-
17
17
said N '/Z, NE '/4, 792.50 feet; thence S86°50'23"E, 850.0 feet; thence S07°51'A�
18
131.19 feet to the point of beginning; thence S45°01'58"E, 291.40 feet; tlEe
=Z
19
S19°43'11"W, 54.48 feet; thence S65°55'46"E.182.33 feet to a point on the west rig #;,�`�
COUN t,i, P�;,�•°
20
of -way line of Arkansas State Highway No. 5 (Stagecoach Road); thence in a
21
southwesterly direction along the west right-of-way line of said highway the following
22
courses: S66°06142"W, 28.75 feet; S20°1310111W, 44.72 feet; S31°24149"W, 218.10
23
feet; thence N58°35'01"W along the north right-of-way line of Stagecoach Village
24
Drive 159.88 feet; thence northwesterly along the arc of a 100.00 foot radius curve to
25 the right having a chord bearing and distance of N47°06'02"W, 51.14 feet; thence
26 northwesterly along the arc of a 185.68 foot radius curve to the left having a chord
27 bearing and distance of N44°34'28"W, 82.99 feet; thence northwesterly along the arc
28 of a 50.0 -foot radius curve to the right having a chord bearing and distance of
29 N41053'08"W, 26.89 feet; thence northwesterly along the arc of a 55.0 -foot radius
30 curve to the left having a chord bearing and distance of N78°36142"W, 87.07 feet;
31 thence southwesterly along the arc of a 25.0 -foot radius curve to the right having a
32 chord bearing and distance of S76°25144"W, 18.15 feet; thence leaving said northerly
33 right-of-way N04021'37'E, 130.03 feet; thence N31°57111"E, 272.77 feet to the point
34 of beginning containing 3.23 acres, more or less.
[Page 1 of 21
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
Section 2. That the preliminary site development plan/plat be approved as recommended by the Little
Rock Planning Commission.
Section 3. That the change in zoning classification contemplated for Stagecoach Village Lot 1
Revised Short -Form POD, located at 9222 Stagecoach Road (Z -6178-K), is conditioned upon obtaining
final plan approval within the time specified by Chapter 36, Article VII, Section 36-454 (e) of the Code of
Ordinances.
Section 4. That this ordinance shall not take effect and be in full force until the final plan approval.
Section 5. That the map referred to in Chapter 36 of the Code of Ordinances of the City of Little Rock,
Arkansas, and Designated District Map be and is hereby amended to the extent and in the respects necessary
to affect and designate the change provided for in Section 1 hereof.
Section 6. Severability. In the event any title, section, paragraph, item, sentence, clause, phrase, or
word of this ordinance is declared or adjudged to be invalid or unconstitutional, such declaration or
adjudication shall not affect the remaining portions of the ordinance which shall remain in full force and
effect as if the portion so declared or adjudged invalid or unconstitutional was not originally a part of the
ordinance.
Section 7. Repealer. All laws, ordinances, resolutions, or parts of the same that are inconsistent with
the provisions of this ordinance are hereby repealed to the extent of such inconsistency.
jSEJ 2018
APPROVE. v. 't� Clerk Mark Stodola, Mayor
TO LEGAL FORM:
Thomas M. Carpenter, ity Atto ey
//
//
//
//
//
//
[Page 2 of 21
f
55 MF6 I IRE NR I CUP k 211 PCD
ED R2- 1:�:p
C2
G
a% moo
IS PRD N1, 341
B
V) LA PRD QQ R71,
04
El
ry
PCD
no HEC336�2;9 M�P 3
7ROSEWALLINO CQ PCD
TZIC2 A
da d n Q ��
20
MF12
01
X
UIDU3
ID U
R 2'
OR2
CUP
MFIB
CUP
NEW
PCD
PCOO
F
1)0
THIS SITE
calUELD-DR 01
R2
12/ CUP
Area Zoning
City of Little Rock Planning & Development
Case: Z -6178-K
Location: 9222 Stagecoach Road
Ward: 7
PD: 16
CT 42.20
TRS: TI S R1 3W 6
N
A
0 200 400
Feet
so
rh9li PIP4K,' 1 10
WOO
C
60,46 w
como
C
Q :8 -
Ogg
C! E.- E2
EL
4,
EZ
Mx
MDR to Q's's Fly,
Olt,
13
ROSEWACONO Ca
<jE@4Z
Q
Lu
vY0
NfEs.THELD_OR
Land Use Plan
City of Little Rock Planning & Development
E:RD=
THIS SITE
City of Little Rock Planning & Development
Case No: Z -6178-K
Name: Stagecoach Village
Location: 9222 Stagecoach Rd.
Title: Revised Short -form POD
N
A
Iz
MF8
CUP 0 t
MF6 I n
o CUP }R2 PCD
aEl
❑� o R2 = v
x �o Q A o d
w� LvirMIT
a ,U �-" nf1� ] - c�
PRnti� 1 1� VLJ L
°IL
0 ° L3 � I TO
a L
Q w o S�� PRD
a�7L�aEJ
CIDS
�7 f PCD
�gGapp
ROSEWALU LN' PCD v
1�1aQ
D R M
Q a� �:j C
�oC71
Q 01
Q as
'D pia
EIgC�C�aG�gC�
r Q WESTFfELD-OR 01
w �7 Q gaapdagd
R2
MF12 CUP
O R2'
n <0
OCUP
MF18
CUP
DJ
PCD
Area Zoning
City of Little Rock Planning & Development
WOMM Ox, !IR!
WIN
low
�� 4 Via w�LtNIAM
arr�rti� y��
n.
�r
THIS SITE
R2
Case: Z -6178-K
Location: 9222 Stagecoach Road
Ward: 7
PD: 16
CT 42.20
TRS: T1 S R1 3W 5
N
0 200 400
Feet
Land Use Plan
City of Little Rock Planning & Development
Case: Z -6178-K
Location: 9222 Stagecoach Road
Ward: 7
N
PD: 16
CT 42.20 0
200 400
TRS: T1 S R1 3W 5
Feet
Proposed Buildings
\\
LOT 1
/ C-3 USES /
IXiSr BLOC
HE G
�nL0T 2 A
-3 & 0-3 Us
Sketch
City of Little Rock Planning &Development
Case No: Z -6178-K
Name: Stagecoach Village
Location: 9222 Stagecoach Rd.
Title: Revised Short -form POD
N
A
LOT 1 (UNRECORDED)
PART OF THE NEU4 OF SECTION 5, T -1-S, R -13-W, LITTLE ROCK, PULASKI
COUNTY, ARKANSAS, MORE PARTICULARLY DESCRIBED AS FOLLOWS:
COMMENCING AT THE SOUTHEAST CORNER OF LOT 62, STAGECOACH
VILLAGE, TRACT A, PHASE 1, AN ADDITION TO THE CITY OF LITTLE ROCK,
ARKANSAS; THENCE N04°21'37"E ALONG THE EAST LINE OF SAID LOT 62
AND ALONG THE EAST LINE OF LOT 60, SAID STAGECOACH VILLAGE,
TRACT A, PHASE 1, 130.03 FT.; THENCE N32°33'27"E ALONG THE EAST LINE
OF SAID LOT 60 AND ALONG THE EAST LINE OF LOTS 59, 58, 56 AND 54, SAID
STAGECOACH VILLAGE, TRACT A, PHASE 1, 273.93 FT.; THENCE S44°52' 13 "E,
291.40 FT.; THENCE S22°31'20"W, 54.48 FT.; TO THE POINT OF BEGINNING;
THENCE S65057'58"E, 182.33 FT, TO A POINT ON THE WEST RIGHT-OF-WAY
LINE OF ARKANSAS STATE HIGHWAY NO. 5, (STAGECOACH ROAD);
THENCE S66005'41 "W ALONG SAID WEST RIGHT-OF-WAY LINE, 28.72 FT.;
THENCE 520036'30"W CONTINUING ALONG SAID WEST RIGHT-OF-WAY LINE,
44.58 FT.; THENCE S3 1'22'37"W CONTINUING ALONG SAID WEST RIGHT-OF-
WAY LINE, 87.51 FT.; THENCE N58°37'23"W, 192.0 FT.; THENCE N39°40'28"E,
133.0 FT. TO THE POINT OF BEGINNING, CONTAINING 0.5909 ACRES MORE
OR LESS.
City of Little Rock
LIOMIDepartment of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
May 21, 2018
Eric Nelson
Newman Moses Tucker Partners
200 River market Avenue Suite 501
Little Rock, AR 72201
Re: Z -6178-K - Stagecoach Village Lot 1 Revised Short -form POD, located at 9222
Stagecoach Road
Dear Sirs:
This is to advise you that in connection with your request concerning the above referenced
file number the following action was taken by the Planning Commission at its meeting on May
17, 2018:
Approved with conditions.
X Recommended approval with conditions.
Recommended approval as submitted.
Denied your request as submitted.
Deferred to the
Other:
Meeting.
This item will be forwarded to the Little Rock Board of Directors for final action. You or your
representative will need to be present at the Board of Directors meeting to address
any questions which may arise. The meeting date has tentatively been set for June 19,
2018. The meeting begins at 6:00 pm and is held in the Board of Directors Chambers, 500
West Markham Street, 2nd floor. If you have any questions please do not hesitate to contact
me at 371-6821.
Respectfully,
Donna James, AICP
Subdivision Administrator
OFFICE OF THE CITY MANAGER
LITTLE ROCK, ARKANSAS
BOARD OF DIRECTORS COMMUNICATION
JUNE 19, 2018 AGENDA
Subject I Action Required I Approved By
An Ordinance establishing 40rdinance
a Planned Zoning District Resolution
titled Stagecoach Village Approval
Lot 1 Revised Short -form Information Report
POD, located at 9222
Stagecoach Road. (Z -6178-
K)
Submitted by:
Department of Planning
and Development
Bruce T. Moore
SYNOPSIS The applicant is proposing to utilize a portion of the existing
building as restaurant use with pick-up service only. The
applicant is proposing a Papa John's restaurant which will
occupy 1,200 square feet of the existing 3,182 square foot
building.
FISCAL IMPACT None.
RECOMMENDATION Staff recommends approval of the requested POD zoning.
The Planning Commission voted to recommend approval of
the POD zoning by a vote of 8 ayes, 0 noes and 3 absent.
BACKGROUND On September 5, 2000, the Board of Directors approved
Ordinance No. 18,342 establishing Stagecoach Village (Lot
4) Short -form PCD. The applicant proposed to construct a
3,600 square foot branch bank building and a 9,000 square
foot commercial building and 54 parking spaces. At the time
of approval, the applicant proposed to convert the bank
building into a commercial building (C-2, Shopping Center
District uses) if a bank tenant could not be secured.
Along with the approved PCD a preliminary plat was created
BACKGROUND
CONTINUED
containing four (4) lots. Only Lot 4 was rezoned to PCD with
the approval. The remaining lots were to be reviewed at the
time of development. The site plan for Lot 4 was later
revised (June 26, 2001) at staff level to remove the bank
building from the site plan and the commercial
building square footage was increased to 10,800 square feet.
The applicant proposed the building to be used as 80%
commercial (C-2, Shopping Center District uses) and 20%
office (general and professional).
Ordinance No. 20,297 adopted by the Little Rock Board of
Directors on August 2, 2010, allowed a revision to the POD,
Planned Office Development. The approval was to allow
Lots 1, 2, and 3 to be reconfigured and developed in a
different development pattern than previously approved.
Lot 1 was proposed developed with a future commercial use
as allowed per the C-2, Shopping Center Zoning District.
The request was to allow Lot 2 to remain as is with the
existing office building and be allowed 0-3, General Office
District uses as allowable uses. Lot 3 was proposed
containing four (4) office buildings each containing from
5,000 to 6,000 square feet. Drives and parking areas were
indicated as cross access and parking.
A daycare and office use have occupied the building located
on Lot 2 which established the POD, Planned Office
Development, zoning. The development plan for Lots 1 and
3 were not completed.
The applicant is now proposing to utilize a portion of the
existing building as restaurant use with pick-up service only.
The applicant is proposing a Papa John's restaurant which
will occupy 1,200 square feet of the existing 3,182 square
foot building. The applicant states there will be no tables for
dining in at the restaurant. The hours of operation are from
10:00 am to 9:30 pm Monday through Thursday and from
10:00 am to 10:30 pm Friday, Saturday and Sunday.
The Planning Commission reviewed the proposed POD
request at its May 17, 2018, meeting and there were no
registered objectors present. The Bentley Court Property
Owners Association, the Chateaus on Stagecoach Property
Owners Association, the Crystal Valley Property
Owners Association, the Wedgewood Creek Homeowners
2
BACKGROUND
CONTINUED
Association and Southwest Little Rock United for Progress
and all property owners located within 200 -feet of the site
were notified of the public hearing. Please see the attached
Planning Commission minute record and site plan for the
applicant's specific development proposal and the staff
analysis and recommendation.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
ORDINANCE NO.
AN ORDINANCE APPROVING A PLANNED ZONING
DEVELOPMENT AND ESTABLISHING A PLANNED OFFICE
DISTRICT TITLED STAGECOACH VILLAGE LOT 1 REVISED
SHORT -FORM POD, LOCATED AT 9222 STAGECOACH ROAD
(Z -6178-K), CITY OF LITTLE ROCK, PULASKI COUNTY,
ARKANSAS, AMENDING THE OFFICIAL ZONING MAP OF THE
CITY OF LITTLE ROCK; AND FOR OTHER PURPOSES.
BE IT ORDAINED BY THE BOARD OF DIRECTORS OF THE CITY OF LITTLE
ROCK, ARKANSAS.
SECTION 1. That the zoning classification of the following described property be
changed from Revised POD, Planned Office Development District to Revised POD, Planned
Office Development District:
Part of the N 1/Z, NE 1/4, Section 5, T -1-S, R -13-W, Little Rock, Pulaski
County, Arkansas, more particularly described as: commencing at the
Southwest corner of the N %, NE 1/4, of said Section 5; thence
NO2°24'49"E along the west line of said N'/Z, NE'/4, 792.50 feet; thence
S86°50123"E, 850.0 feet; thence S07°51'38"W, 131.19 feet to the point
of beginning; thence S45°01'58"E, 291.40 feet; thence S19°43'11"W,
54.48 feet; thence S65°55'46"E. 182.33 feet to a point on the west right
of way line of Arkansas State Highway #5 (Stagecoach Road); thence
in a southwesterly direction along the west right of way line of said
Highway the following courses: S66°06142"W, 28.75 feet; S20°13'01"W,
44.72 feet; S31°24'49"W, 218.10 feet; thence N58°35'01"W along the
north right of way line of Stagecoach Village Drive 159.88 feet; thence
northwesterly along the arc of a 100.00 foot radius curve to the right
having a chord bearing and distance of N47°06'02"W, 51.14 feet;
Page 1 of 3
I thence northwesterly along the arc of a 185.68 foot radius curve to the
2 left having a chord bearing and distance of N44°34'28"W, 82.99 feet;
3 thence northwesterly along the arc of a 50.0 foot radius curve to the
4 right having a chord bearing and distance of N41°53108"W, 26.89 feet;
5 thence northwesterly along the arc of a 55.0 foot radius curve to the left
6 having a chord bearing and distance of N78036'42"W, 87.07 feet;
7 thence southwesterly along the are of a 25.0 foot radius curve to the
8 right having a chord bearing and distance of S76°25'44"W, 18.15 feet;
9 thence leaving said northerly right of way N04021'37'E, 130.03 feet;
10 thence N31°57'11"E, 272.77 feet to the point of beginning containing
11 3.23 acres more or less.
12
13 SECTION 2. That the preliminary site development plan/plat be approved as
14 recommended by the Little Rock Planning Commission.
15
16 SECTION 3. That the change in zoning classification contemplated for
17 Stagecoach Village Lot 1 Revised Short -form POD, located at 9222 Stagecoach Road (Z-6178-
18 K) is conditioned upon obtaining final plan approval within the time specified by Chapter 36,
19 Article VII, Section 36-454 (e) of the Code of Ordinances.
20
21 SECTION 4. That this Ordinance shall not take effect and be in full force until the
22 final plan approval.
23
24 SECTION 5. That the map referred to in Chapter 36 of the Code of Ordinances of
25 the City of Little Rock, Arkansas, and designated district map be and is hereby amended to the
26 extent and in the respects necessary to affect and designate the change provided for in Section
27 1 hereof.
28
29 SECTION 6. Severability. In the event any title, section, paragraph, item,
30 sentence, clause, phrase, or word of this ordinance is declared or adjudged to be invalid or
31 unconstitutional, such declaration or adjudication shall not affect the remaining portions of the
Page 2 of 3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
ordinance which shall remain in full force and effect as if the portion so declared or adjudged
invalid or unconstitutional was not originally a part of the ordinance.
SECTION 7. Repealer. All laws, ordinances, resolutions, or parts of the same
that are inconsistent with the provisions of this ordinance are hereby repealed to the extent of
such inconsistency.
PASSED:
ATTEST:
City Clerk
APPROVED AS TO FORM:
City Attorney
H
H
H
H
H
APPROVED:
Mayor
Page 3 of 3
Z Ix
MF6�1]MF6
CUP W l L2o CUP r2
� J I
q uo E? o CI
ti p� PRD D"-'�! fj L!vj C' C
q PN
3 �� ~
El
W LEI
p ZA .�
L Via¢
lzj F
r PCD
-ROSEWALL LN,—) PCD
�b�da
4,
t� MF12
ED �lLXLu
Lu
WEST
PCD
C2
O R2'
0 r
r--
POD Gp�
PCD
�r
R2
r ` CUP
MF18
CUP
r
U
'C3
I
PCD �,
N Q F#ELD.f]R 01
2CLI R2
MF12 .• CUP
Area Zoning
City of Little Rock Planning & Development
Vicinity Map
Rev: 4/10/2018
THIS SITE
R2
Case: Z -6178-K
Location: 9222 Stagecoach Road
Ward: 7
PD: 16
CT: 42.20
TRS: T1 S R1 3W 5
N
0 200 400
Feet
o
01 —J, TIMIT 1. 1
so c
c
c
ul
PI
Land Use Plan
City of Little Rock Planning & Development
I Vicinity Map
Ll=� —P,
E J
,�; I
Rev: 4/10/2018
THIS SITE
Case: Z -6178-K
Location: 9222 Stagecoach Road
Ward: 7
PD: 16
CT 42.20
TRS: T1 S R1 3W 5
N
4
0 200 400
MMME=��
Feet
fl- 111
� Z
E) BE
M
'0'1
T—W Bp
Lu
U,
UJV/
r
D
0—;�.
-1
F I
F I
D
(uqj
') r7
C
��
L7 IRL
o
01 —J, TIMIT 1. 1
so c
c
c
ul
PI
Land Use Plan
City of Little Rock Planning & Development
I Vicinity Map
Ll=� —P,
E J
,�; I
Rev: 4/10/2018
THIS SITE
Case: Z -6178-K
Location: 9222 Stagecoach Road
Ward: 7
PD: 16
CT 42.20
TRS: T1 S R1 3W 5
N
4
0 200 400
MMME=��
Feet
Proposed Buildings
r � �
I LOT 30
LOT 3e
}/ \
C-3 USES
i:Frf 3A / �,,\ �
r . ,
Irf
LOT .2.
`.-3 & 0-3 us sur I
Sketch
City of Little Rock Planning &Development
Case No: Z -6178-K
Name: Stagecoach Village
Location: 9222 Stagecoach Rd.
Title: Revised Short -form POD
N
A
PART OF THE N 1/2 NE 1/4 OF SECTION 5, TOWNSHIP 1 SOUTH, RANGE 13 WEST, LITTLE
ROCK, PULASKI COUNTY, ARKANSAS, MORE PARTICULARLY DESCRIBED AS:
COMMENCING AT THE SW CORNER OF THE N 1/2 NE 1/4 OF SECTION 5, THENCE NORTH 00
DEGREES 06 MINUTES 15 SECONDS WEST 792.90 FEET; THENCE SOUTH 89 DEGREES 21
MINUTES 24 SECONDS EAST 850.00 FEET; THENCE SOUTH 05 DEGREES 20 MINUTE 34
SECONDS WEST 131.19 FEET; THENCE SOUTH 47 DEGREES 33 MINUTES 02 SECONDS EAST
291.40 FEET; THENCE SOUTH 17 DEGREES 12 MINUTES 07 SECONDS WEST 54.48 FEET;
THENCE SOUTH 68 DEGREES 26 MINUTES 50 SECONDS EAST 182.33 FEET TO A POINT ON
THE WEST RIGHT OF WAY LINE OF ARKANSAS HIGHWAY 5 (STAGECOACH ROAD; THENCE
IN A SOUTHERLY DIRECTION ALONG THE WEST RIGHT OF WAY LINE OF SAID HIGHWAY
THE FOLLOWING COURSES: SOUTH 63 DEGREES 35 MINUTES 38 SECONDS WEST 28.73 FEET;
THENCE SOUTH 17 DEGREES 41 MINUTES 57 SECONDS WEST 44.72 FEET; THENCE SOUTH 28
DEGREES 53 MINUTES 45 SECONDS WEST 88.10 FEET TO THE POINT OF BEGINNING;
THENCE CONTINUE SOUTH 28 DEGREES 53 MINUTES 45 SECONDS WEST ALONG THE WEST
RIGHT OF WAY LINE OF SAID HIGHWAY 130.0 FEET; THENCE NORTH 61 DEGREES 06
MINUTES 15 SECONDS WEST 70.78 FEET TO THE POINT OF CURVATURE OF A CURVE TOT
HE LEFT HAVING A RADIUS OF 460 FEET; THENCE IN A NORTHWESTERLY DIRECTION
ALONG THE ARC OF SAID CURVE TO THE LEFT TO A POINT WHICH IS NORTH 69 DEGREES
54 MINUTES 45 SECONDS WEST 140.88 FEET FROM THE POINT OF CURVATURE THEREOF;
THENCE NORTH 28 DEGREES 53 MINUTES 45 SECONDS EAST 151.57 FEET; THENCE SOUTH
61 DEGREES 06 MINUTES 15 SECONDS EAST 210.0 FEET TO THE POINT OF BEGINNING.
LESS AND EXCEPT PART OF THE NE 1/4 OF SECTION 5, TOWNSHIP 1 SOUTH, RANGE 13
WEST, LITTLE ROCK, PULASKI COUNTY, ARKANSAS, MORE PARTICULARLY DESCRIBED
AS: COMMENCING AT THE SW CORNER OF THE N 1/2 NE 1/4 OF SECTION 5, THENCE SOUTH
85 DEGREES 57 MINUTES 00 SECONDS EAST ALONG THE SOUTH LINE OF SAID N 1/2 NE 1/4
689.05 FEET TO THE POINT OF BEGINNING; THENCE NORTH 01 DEGREE 50 MINUTES 33
SECONDS EAST 374.02 FEET; THENCE SOUTH 88 DEGREES 09 MINUTES 37 SECONDS EAST
30.17 FEET TO THE POINT OF CURVATURE OF A CURVE TO THE RIGHT HAVING A CENTRAL
ANGLE OF 56 DEGREES 20 MINUTES 19 SECONDS AND A RADIUS OF 125.69 FEET; THENCE
IN A SOUTHEASTERLY DIRECTION ALONG AN ARC OF SAID CURVE TO THE RIGHT TO THE
POINT OF TANGENCY THEREOF (SAID CURVE SEGMENT HAVING A CHORD BEARING AND
DISTANCE OF SOUTH 62 DEGREES 11 MINUTES 10 SECONDS EAST 118.67 FEET; SAID POINT
ALSO BEING THE POINT OF CURVATURE OF A CURVE TO THE LEFT HAVING A CENTRAL
ANGLE OF 27 DEGREES 02 MINUTES 25 SECONDS AND A RADIUS OF 175.66 FEET; THENCE
IN A SOUTHEASTERLY DIRECTION ALONG THE ARC OF SAID CURVE TO THE LEFT TO THE
POINT OF TANGENCY THEREOF (SAID CURVE SEGMENT HAVING A CHORD BEARING AND
DISTANCE OF SOUTH 48 DEGREES 40 MINUTES 06 SECONDS EAST 1.83 FEET; THENCE
SOUTH 61 DEGREES 06 MINUTES 15 SECONDS EAST 124.29 FEET TO THE POINT OF
CURVATURE OF A CURVE TO THE RIGHT HAVING A RADIUS OF 15.0 FEET; THENCE IN A
SOUTHEASTERLY DIRECTION ALONG THE ARC OF SAID CURVE TO THE RIGHT TO THE
POINT OF TANGENCY THEREOF (SAID CURVE SEGMENT HAVING A CHORD BEARING AND
DISTANCE OF SOUTH 16 DEGREES 06 MINUTES 15 SECONDS EAST 35.36 FEET); THENCE
SOUTH 28 DEGREES 53 MINUTES 45 SECONDS WEST 18.90 FEET TO A POINT ON THE
NORTHWESTERLY RIGHT OF WAY LINE OF ARKANSAS HIGHWAY 5 (STAGECOACH ROAD);
THENCE IN A SOUTHERLY DIRECTION ALONG SAID HIGHWAY RIGHT OF WAY THE
FOLLOWING COURSES: SOUTH 53 MINUTES 20 SECONDS 13 MINUTES WEST 36.25 FEET;
SOUTH 06 DEGREES 12 MINUTES 54 SECONDS WEST 64.83 FEET; THENCE NORTH 85
DEGREES 47 MINUTES 00 SECONDS WEST 62.47 FEET; THENCE NORTH 86 DEGREES 13
MINUTES 00 SECONDS WEST 100.0 FEET; THENCE NORTH 86 DEGREES 26 MINUTES 00
SECONDS WEST 100.0 FEET; THENCE NORTH 86 DEGREES 15 MINUTES 00 SECONDS WEST
16.28 FEET; THENCE NORTH 01 DEGREE 50 MINUTES 23 SECONDS EAST 14.40 FEET TO THE
POINT OF BEGINNING.
LESS AND EXCEPT LOT 4, STAGECOACH VILLAGE, LITTLE ROCK, PULASKI COUNTY,
ARKANSAS, AS SHOWN 1N PLAT OF RECORD IN PLAT BOOK G PAGE 201, RECORDS OF
PULASKI COUNTY, ARKANSAS.
LESS AND EXCEPT THAT PORTION LYING WITHIN THE RIGHT OF WAY OF STAGECOACH
DRIVE AS SHOWN IN PLAT OF RECORD IN PLAT BOOK G PAGE 201, RECORDS OF PULASKI
COUNTY, ARKANSAS.
PART OF THE N 1/2 NE 1/4 OF SECTION 5, TOWNSHIP 1 SOUTH, RANGE 13 WEST, LITTLE
ROCK, PULASKI COUNTY, ARKANSAS, MORE PARTICULARLY DESCRIBED AS:
COMMENCING AT THE SW CORER OF THE N 1/2 NE 1/4 OF SECTION 5; THENCE NORTH 00
DEGREES 06 MINUTES 15 SECONDS WEST ALONG THE WEST LINE OF SAID N 1/2 NE 1/4
792.90 FEET; THENCE SOUTH 89 DEGREES 21 MINUTES 24 SECONDS EAST 850.00 FEET;
THENCE SOUTH 05 DEGREES 20 MINUTES 34 SECONDS WEST 131.19 FEET TO THE POINT OF
BEGINNING; THENCE SOUTH 47 DEGREES 33 MINUTES 02 SECONDS EAST 291.40 FEET;
THENCE SOUTH 17 DEGREES 12 MINUTES 07 SECONDS WEST 54.48 FEET; THENCE NORTH 68
DEGREES 26 MINUTES 50 SECONDS WEST 37.14 FEET; THENCE SOUTH 28 DEGREES 53
MINUTES 45 SECONDS WEST 279.11 FEET TO A POINT ON THE ARC OF A CURVE TO THE
LEFT HAVING A RADIUS OF 460 FEET; THENCE IN A NORTHWESTERLY DIRECTION ALONG
THE ARC OF SAID CURVE TO THE LEFT TO THE POINT OF TANGENCY THEREOF (SAID
CURVE SEGMENT HAVING A CHORD BEARING AND DISTANCE OF NORTH 84 DEGREES 24
MINUTES 45 SECONDS WEST 91.4 FEET); THENCE SOUTH 89 DEGREES 53 MINUTES 45
SECONDS WEST 80.24 FEET; THENCE NORTH 01 DEGREE 50 MINUTES 23 SECONDS EAST
74.76 FEET; THENCE NORTH 19 DEGREES 21 MINUTES 45 SECONDS EAST 419.72 FEET TO
THE POINT OF BEGINNING.
LESS AND EXCEPT PART OF THE NE 1/4 OF SECTION 5, TOWNSHIP 1 SOUTH, RANGE 13
WEST, LITTLE ROCK, PULASKI COUNTY, ARKANSAS, MORE PARTICULARLY DESCRIBED
AS: COMMENCING AT THE SW CORNER OF THE N 1/2 NE 1/4 OF SECTION 5, THENCE SOUTH
85 DEGREES 57 MINUTES 00 SECONDS EAST ALONG THE SOUTH LINE OF SAID N 1/2 NE 1/4
689.05 FEET TO THE POINT OF BEGINNING; THENCE NORTH 01 DEGREE 50 MINUTES 33
SECONDS EAST 374.02 FEET; THENCE SOUTH 88 DEGREES 09 MINUTES 37 SECONDS EAST
30.17 FEET TO THE POINT OF CURVATURE OF A CURVE TO THE RIGHT HAVING A CENTRAL
ANGLE OF 56 DEGREES 20 MINUTES 19 SECONDS AND A RADIUS OF 125.69 FEET; THENCE
IN A SOUTHEASTERLY DIRECTION ALONG AN ARC OF SAID CURVE TO THE RIGHT TO THE
POINT OF TANGENCY THEREOF (SAID CURVE SEGMENT HAVING A CHORD BEARING AND
DISTANCE OF SOUTH 62 DEGREES 11 MINUTES 10 SECONDS EAST 118.67 FEET; SAID POINT
ALSO BEING THE POINT OF CURVATURE OF A CURVE TO THE LEFT HAVING A CENTRAL
ANGLE OF 27 DEGREES 02 MINUTES 25 SECONDS AND A RADIUS OF 175.66 FEET IN A
SOUTHERLY DIRECTION ALONG THE ARC OF SAID CURVE TO THE LEFT TO THE POINT OF
TANGENCY THEREOF (SAID CURVE SEGMENT HAVING A CHORD BEARING AND DISTANCE
OF SOUTH 48 DEGREES 40 MINUTES 06 SECONDS EAST 1.83 FEET; THENCE SOUTH 61
DEGREES 06 MINUTES 15 SECONDS EAST 124.29 FEET TO THE POINT OF CURVATURE OF A
CURVE TO THE RIGHT HAVING A RADIUS OF 15.0 FEET; THENCE IN A SOUTHEASTERLY
DIRECTION ALONG THE ARC OF SAID CURVE TO THE RIGHT TO THE POINT OF TANGENCY
THEREOF (SAID CURVE SEGMENT HAVING A CHORD BEARING AND DISTANCE OF SOUTH
16 DEGREES 06 MINUTES 15 SECONDS EAST 35.36 FEET); THENCE SOUTH 28 DEGREES 53
MINUTES 45 SECONDS WEST 18.90 FEET TO A POINT ON THE NORTHWESTERLY RIGHT OF
WAY LINE OF ARKANSAS HIGHWAY 5 (STAGECOACH ROAD); THENCE IN A SOUTHERLY
DIRECTION ALONG SAID HIGHWAY RIGHT OF WAY THE FOLLOWING COURSES: SOUTH 53
MINUTES 20 SECONDS 13 MINUTES WEST 36.25 FEET; SOUTH 06 DEGREES 12 MINUTES 54
SECONDS WEST 64.83 FEET; THENCE NORTH 85 DEGREES 47 MINUTES 00 SECONDS WEST
62.47 FEET; THENCE NORTH 86 DEGREES 13 MINUTES 00 SECONDS WEST 100.0 FEET;
THENCE NORTH 86 DEGREES 26 MINUTES 00 SECONDS WEST 100.0 FEET; THENCE NORTH 86
DEGREES 15 MINUTES 00 SECONDS WEST 16.28 FEET; THENCE NORTH 01 DEGREE 50
MINUTES 23 SECONDS EAST 14.40 FEET TO THE POINT OF BEGINNING.
LESS AND EXCEPT LOT 4, STAGECOACH VILLAGE, LITTLE ROCK, PULASKI COUNTY,
ARKANSAS, AS SHOWN IN PLAT OF RECORD IN PLAT BOOK G PAGE 201, RECORDS OF
PULASKI COUNTY, ARKANSAS,
LESS AND EXCEPT THAT PORTION LYING WITHIN THE RIGHT OF WAY OF STAGECOACH
DRIVE AS SHOWN IN PLAT OF RECORD IN PLAT BOOK G PAGE 201, RECORDS OF PULASKI
COUNTY,ARKANSAS.
LESS AND EXCEPT: PART OF THE NE %4 OF SECTION 5, TOWNSHIP 1 SOUTH, RANGE 13
WEST, IN THE CITY OF LITTLE ROCK, PULASKI COUNTY, ARKANSAS, MORE
PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE SOUTHEAST CORNER OF
LOT 62, STAGECOACH VILLAGE, TRACT A, PHASE 1, AN ADDITION TO THE CITY OF LITTLE
ROCK, ARKANSAS; THENCE NORTH 04 DEGREES 21 MINUTES 37 SECONDS EAST ALONG
THE EAST LINE OF SAID LOT 62 AND ALONG THE EAST LINE OF LOT 60, SAID STAGECOACH
VILLAGE, TRACT A, PHASE 1, 130.03 FEET; THENCE NORTH 32 DEGREES 33 MINUTES 27
SECONDS EAST ALONG THE EAST LINE OF SAID LOT 60 AND ALONG THE EAST LINE OF
LOTS 59, 58, 56, AND 54, SAID STAGECOACH VILLAGE TRACT A, PHASE 1, 273.93 FEET;
THENCE SOUTH 44 DEGREES 52 MINUTES 13 SECONDS EAST, 291.40 FEET; THENCE SOUTH
22 DEGREES 31 MINUTES 20 SECONDS WEST 54.48 FEET; THENCE SOUTH 65 DEGREES 57
MINUTES 58 SECONDS EAST, 182.33 FEET TO POINT ON THE WEST RIGHT OF WAY LINE OF
ARKANSAS STATE HIGHWAY NO. 5 (STAGECOACH ROAD); THENCE SOUTH 66 DEGREES 05
MINUTES 41 SECONDS WEST ALONG SAID WEST RIGHT OF WAY LINE, 28.72 FEET; THENCE
SOUTH 20 DEGREES 36 MINUTES 30 SECONDS WEST, CONTINUING ALONG SAID WEST
RIGHT OF WAY LINE, 44.58 FEET; THENCE SOUTH 31 DEGREES 22 MINUTES 37 SECONDS
WEST, CONTINUING ALONG SAID WEST RIGHT OF WAY LINE, 87.51 FEET TO THE POINT OF
BEGINNING; THENCE SOUTH 31 DEGREES 22 MINUTES 37 SECONDS WEST, CONTINUING
ALONG SAID WEST RIGHT OF WAY LINE, 105.59 FEET TO A POINT ON THE NORTH RIGHT OF
WAY LINE OF STAGECOACH VILLAGE DRIVE; THENCE WESTERLY ALONG SAID NORTH
RIGHT OF WAY LINE THE FOLLOWING: (1) NORTH 58 DEGREES 37 MINUTES 23 SECONDS
WEST, 10.00 FEET; (2) WESTERLY ALONG THE ARC OF A 25.00 FOOT RADIUS CURVE TO THE
RIGHT, A CHORD BEARING AND DISTANCE OF SOUTH 76 DEGREES 14 MINUTES 08
SECONDS WEST, 35.29 FEET; (3) NORTH 58 DEGREES 35 MINUTES 01 SECOND WEST, 124.88
FEET AND (4) WESTERLY ALONG THE ARC OF A 115.66 FOOT RADIUS CURVE TO THE RIGHT
A CHORD BEARING AND DISTANCE OF NORTH 46 DEGREE 32 MINUTES 46 SECONDS WEST
53.32 FEET; THENCE NORTH 40 DEGREES 50 MINUTES 48 SECONDS EAST 121.01 FEET;
THENCE SOUTH 58 DEGREES 37 MINUTES 23 SECONDS EAST 192.00 FEET TO THE POINT OF
BEGINNING.
STAGECOACH VILLAGE, LLC
601 STAGECOACH VILLAGE CIR.
LITTLE ROCK, AR 72210
LOT 1, STAGECOACH VILLAGE, TRACT A, PHASE 1, AN ADDITION TO THE CITY OF LITTLE
ROCK, PULASKI COUNTY, ARKANSAS.
MARCY N. WALLACE
9 STAGECOACH VILLAGE DR.
LITTLE ROCK, AR 72210
LOT 62, STAGECOACH VILLAGE, TRACT A, PHASE I, AN ADDITION TO THE CITY OF LITTLE
ROCK, PULASKI COUNTY, ARKANSAS.
PATRICIA M. ROSS
416 PEPPERBUSH BEND
CANTON, GA 30114
LOT 4, STAGECOACH VILLAGE, LITTLE ROCK, PULASKI COUNTY, ARKANSAS.
STAGE PARTNERS, LLC
2100 RIVERDALE RD., STE. 100
LITTLE ROCK, AR 72202
LOT 1, GRANDPA'S CATFISH SUBDIVISION, LITTLE ROCK, PULASKI COUNTY, ARKANSAS.
TMT INVESTMENTS, LLC
P.O. BOX 1066
BRYANT, AR 72089
LOT 1, AUTOZONE AT STAGECOACH SUBDIVISION, AN ADDITION TO THE CITY OF LITTLE
ROCK, PULASKI COUNTY, ARKANSAS.
AUTOZONE DEVELOPMENT, LLC
123 S. FRONT ST., 3RD FLOOR
MEMPHIS, TN 38103
PART OF THE NE %4 OF SECTION 5, TOWNSHIP I SOUTH, RANGE 13 WEST, PULASKI COUNTY,
ARKANSAS, MORE PARTICULARLY DESCRIBED AS FOLLOWS, TO -WIT: BEGINNING AT THE
NORTHEAST CORNER OF SECTION 5; RUN THENCE WEST ALONG THE NORTH LINE OF
SECTION 5 A DISTANCE OF 814 FEET TO THE EAST LINE OF HOT SPRINGS HIGHWAY;
THENCE SOUTH 22 DEGREES 45 MINUTES WEST 985 FEET ALONG THE EAST LINE OF
HIGHWAY TO A POINT; THENCE SOUTH 30 DEGREES WEST 407 FEET ALONG EAST LINE OF
HIGHWAY TOA POINT, AND BEING THE POINT OF BEGINNING; THENCE SOUTH 30 DEGREES
WEST 278 FEET ALONG THE EAST LINE OF HIGHWAY; THENCE SOUTH 86 DEGREES EAST
360 FEET TO THE CENTER OF FOURCHE CREEK; THENCE NORTHEASTERLY ALONG THE
CENTER OF FOURCHE CREEK TO A POINT, WHICH IS DUE EAST OF THE POINT OF
BEGINNING; THENCE WEST 395 FEET TO THE POINT OF BEGINNING.
DAVID B. HENNING AND
KIMBERLY S. HENNING
934 PARKSIDE DR.
REDFIELD, AR 72132
PART OF THE S 1.2 N''h NE 114 OF SECTION 5, TOWNSHIP 1 SOUTH, RANGE 13 WEST, LYING
WEST, LYING WEST OF STAGECOACH ROAD, MORE PARTICULARLY DESCRIBED AS
FOLLOWS: COMMENCING AT THE SOUTHEAST CORNER OF THE N'/z NE 1/4 SAID SECTION 5,
THENCE NORTH 85 DEGREES 57 MINUTES WEST 1576 FEET TO A POINT ON THE WEST
RIGHT OF WAY LINE OF SAID STAGECOACH ROAD; THENCE NORTH 28 DEGREES 56
MINUTES EAST 449.8 FEET ALONG SAID WEST RIGHT OF WAY LINE TO AN IRON PIN AND
THE POINT OF BEGINNING; THENCE NORTH 68 DEGREES 27 MINUTES WEST 228.25 FEET;
THENCE NORTH 20 DEGREES 27 MINUTES EAST 55 FEET TO A POINT; THENCE NORTH 47
DEGREES 33 MINUTES WEST 141.5 FEET; THENCE NORTH 79 DEGREES 27 MINUTES EAST
152.4 FEET; THENCE NORTH 20 DEGREES 10 MINUTES EAST 50 FEET; THENCE SOUTH 8
DEGREES 09 MINUTES EAST 268.4 FEET TO THE WEST RIGHT OF WAY LINE OF
STAGECOACH ROAD; THENCE SOUTH 22 DEGREES 27 MINUTES WEST 36.3 FEET; THENCE
SOUTH 28 DEGREES 39 MINUTES WEST 247.6 FEET TO THE POINT OF BEGINNING.
BILLY JEAN BARCLAY
9202 STAGECOACH RD.
LITTLE ROCK, AR 72210
CERTIFIED THIS THE 2ND DAY OF APRIL, 2018 @ 6:00 A.M.
THIS IS A LIMITED SEARCH OF THE RECORDS AND IS NOT TO BE CONSTRUED AS A
TITLE INSURANCE POLICY, LEGAL OPINION OR COMMITMENT TO INSURE. LIABILITY IS
LIMITED TO THE AMOUNT CHARGED FOR THIS SEARCH.
SINGER Y,
iLLIAM G. LETZ
RTA NO.16876100
PTLAi-ll
COUNTY TITLE
8114 CANTRELL ROAD STE 300
LITTLE ROCK, ARKANSAS 72227
501-537-3700 FAX 501-537-3701
18 APRIL, 2018
RE: PART OF THE NE %, OF SECTION 5, TOWNSHIP 1 SOUTH, RANGE 13 WEST, IN THE CITY OF LITTLE ROCK,
PULASKI COUNTY, ARKANSAS, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE
SOUTHEAST CORNER OF LOT 62, STAGECOACH VILLAGE, TRACT A, PHASE 1, AN ADDITION TO THE
CITY OF LITTLE ROCK, ARKANSAS; THENCE NORTH 04 DEGREES 21 MINUTES 37 SECONDS EAST ALONG
THE EAST LINE OF SAID LOT 62 AND ALONG THE EAST LINE OF LOT 60, SAID STAGECOACH VILLAGE,
TRACT A, PHASE 1, 130.03 FEET; THENCE NORTH 32 DEGREES 33 MINUTES 27 SECONDS EAST ALONG THE
EAST LINE OF SAID LOT 60 AND ALONG THE EAST LINE OF LOTS 59, 58, 56, AND 54, SAID STAGECOACH
VILLAGE TRACT A, PHASE 1, 273.93 FEET; THENCE SOUTH 44 DEGREES 52 MINUTES 13 SECONDS EAST,
291.40 FEET; THENCE SOUTH 22 DEGREES 31 MINUTES 20 SECONDS WEST 54.48 FEET; THENCE SOUTH 65
DEGREES 57 MINUTES 58 SECONDS EAST, 182.33 FEET TO POINT ON THE WEST RIGHT OF WAY LINE OF
ARKANSAS STATE HIGHWAY NO. 5 (STAGECOACH ROAD); THENCE SOUTH 66 DEGREES 05 MINUTES 41
SECONDS WEST ALONG SAID WEST RIGHT OF WAY LINE, 28.72 FEET; THENCE SOUTH 20 DEGREES 36
MINUTES 30 SECONDS WEST, CONTINUING ALONG SAID WEST RIGHT OF WAY LINE, 44.58 FEET; THENCE
SOUTH 31 DEGREES 22 MINUTES 37 SECONDS WEST, CONTINUING ALONG SAID WEST RIGHT OF WAY
LINE, 87.51 FEET TO THE POINT OF BEGINNING; THENCE SOUTH 31 DEGREES 22 MINUTES 37 SECONDS
WEST, CONTINUING ALONG SAID WEST RIGHT OF WAY LINE, 105.59 FEET TO A POINT ON THE NORTH
RIGHT OF WAY LINE OF STAGECOACH VILLAGE DRIVE; THENCE WESTERLY ALONG SAID NORTH
RIGHT OF WAY LINE THE FOLLOWING: (1) NORTH 58 DEGREES 37 MINUTES 23 SECONDS WEST, 10.00
FEET; (2) WESTERLY ALONG THE ARC OF A 25.00 FOOT RADIUS CURVE TO THE RIGHT, A CHORD
BEARING AND DISTANCE OF SOUTH 76 DEGREES 14 MINUTES 08 SECONDS WEST, 35.29 FEET; (3) NORTH
58 DEGREES 35 MINUTES 01 SECOND WEST, 124.88 FEET AND (4) WESTERLY ALONG THE ARC OF A 115.66
FOOT RADIUS CURVE TO THE RIGHT A CHORD BEARING AND DISTANCE OF NORTH 46 DEGREE 32
MINUTES 46 SECONDS WEST 53.32 FEET; THENCE NORTH 40 DEGREES 50 MINUTES 48 SECONDS EAST
121.01 FEET; THENCE SOUTH 58 DEGREES 37 MINUTES 23 SECONDS EAST 192.00 FEET TO THE POINT OF
BEGINNING.
THE FOLLOWING IS A LIST OF THE APPARENT PROPERTY
OWNERS LYING WITHIN 200 FEET OF THE ABOVE DESCRIBED LAND:
PART OF THE N 1/2 NE 1/4, SECTION 5, TOWNSHIP 1 SOUTH, RANGE 13 WEST, LITTLE ROCK,
PULASKI COUNTY, ARKANSAS, MORE PARTICULARLY DESCRIBED AS: COMMENCING AT
THE SW CORNER OF THE N 1/2 NE 1/4 OF SECTION 5; THENCE NORTH 00 DEGREES 06
MINUTES 15 SECONDS WEST 792.90 FEET; THENCE SOUTH 89 21 MINUTES 24 SECONDS EAST
850.0 FEET; THENCE SOUTH 05 DEGREES 20 MINUTES 34 SECONDS WEST 121.13 FEET;
THENCE SOUTH 47 DEGREES 33 MINUTES 07 SECONDS 291.40; THENCE SOUTH 17 DEGREES
12 MINUTES 07 SECONDS WEST 54.48 FEET TO THE POINT OF BEGINNING; THENCE SOUTH
68 DEGREES 26 MINUTES 50 SECONDS EAST 182.33 FEET TO A POINT ON THE WEST RIGHT
OF WAY LINE OF ARKANSAS HIGHWAY 5 (STAGECOACH ROAD); THENCE IN A
SOUTHWESTERLY DIRECTION ALONG THE WEST RIGHT OF WAY LINE OF SAID HIGHWAY
THE FOLLOWING COURSES: SOUTH 63 DEGREES 35 MINUTES 38 SECONDS WEST 28.73 FEET;
THENCE SOUTH 17 DEGREES 41 MINUTES 57 SECONDS WEST 44.72 FEET; THENCE SOUTH 28
DEGREES 53 MINUTES 45 SECONDS WEST 88.10 FEET; THENCE NORTH 61 DEGREES 06
MINUTES 15 SECONDS WEST 210.0 FEET; THENCE NORTH 28 DEGREES 53 MINUTES 45
SECONDS EAST 127.54 FEET; THENCE SOUTH 68 DEGREES 26 MINUTES 50 SECONDS EAST
37.14 FEET TO THE POINT OF BEGINNING.
AND
sfpzd.doc
NOTICE OF PUBLIC HEARING BEFORE
THE LITTLE ROCK PLANNING COMMISSION
ON AN APPLICATION TO ESTABLISH A
SHORT -FORM PLANNED ZONING DEVELOPMENT
To ALL owners of land lying within 200 feet of the boundary of the property located at:
03/01/10
Address: VI' s iLAU aLS
r. r -r;,,,, -1 . k . ,c ... �A —P 4.k. s., f, Lc ,.,.}
Owned by: " g 1i
i 16u LL
NOTICE IS HEREBY GIVEN THAT an application for a Planned Zoning Deveiopment of the abov�
property requesting a change of classification from District to f
oy has been filed with the Department of Planning and Development. A public
hearing on said application will be held by the Little Rock Planning Commission in the Board of
Directors Chamber, Second Floor, City Hall, on "�' 0� _,at ' Sy M
p.m.
ALL PARTIES INT INTEREST MAY APPEAR and be heard at said time and place, or may notify the
Planning Commission of their views on this matter by letter. All persons interested in this request are
invited to call or visit the Department of Planning and Development, 723 W. Markham, 371-4790, and
to review the application and discuss same with the Planning staff.
AFFIDAVIT
I hereby certify that I have notified all the pry rty owners of record within 200 feet of the above
property that subject property is being considered [or rezoning�d that a Public Hearing will be held by
the Little Rock Planning Commission at the time d place ries bed above.
Applicant (owner or authorized agent)l
(Nome) .
(Date)
mm��-0
A. IMMICUMIN
L
.. L
mk;www
Ul k
N/27-,-T�T ti 00 5e
W.W &
ru
ca
nA
CH rn
C�
L7'
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF
LAND
April 12, 2018
Bentley Court POA
Christopher Henry
P.O. Box 30934
Little Rock, AR 72260
REQUEST: Stagecoach Village Lot 1 Revised Short -form POD Z -6178-K . a
request to allow the conversion of a portion of the existing building into a restaurant use
and allow for the remainder of the buildinq to be used as offices ace.
GENERAL LOCATION OR ADDRESS: 9222 Stagecoach Road
OWNED BY/APPLICANT: Eric Nelson, Moses Tucker Partners Agent 501.951.1802)
NOTICE IS HEREBY GIVEN THAT an application for a Planned Zoning Development of
the above property has been filed with the Department of Planning and Development. A
public hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on May 17,
2018 at 4:00 P.M. This notice is provided in order to assure that neighborhood
associations are aware of issues that may affect their neighborhood. Information
requests should be directed to the Planning staff at 371-4790.
Jamie Collins
Director of Planning and Development
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF
LAND
April 12, 2018
Chateaus on Stagecoach
Christye Walker
59 Chateaus Lane
Little Rock, AR 72210
REQUEST: Stagecoach Village Lot 1 Revised Short -form POD Z -6178-K a
request to allow the conversion of a 12ortion of the existing building into a restaurant use
and allow for the remainder of the building to be used as offices ace.
GENERAL LOCATION OR ADDRESS: 9222 Stagecoach Road
OWNED BY/APPLICANT: Eric Nelson. Moses, Tucker Partners Agent 501.951.1802
NOTICE IS HEREBY GIVEN THAT an application for a Planned Zoning Development of
the above property has been filed with the Department of Planning and Development. A
public hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on May 17,
2018 at 4:00 P.M. This notice is provided in order to assure that neighborhood
associations are aware of issues that may affect their neighborhood. Information
requests should be directed to the Planning staff at 371-4790.
Jamie Collins
Director of Planning and Development
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF
LAND
April 12, 2018
Crystal Valley Property Owners Association
Larry Welch
16001 Crystal Valley Rd.
Little Rock, AR 72210
REQUEST: Stagecoach Village Lot 1 Revised Short -form POD Z -6178-K a
reguest to allow the conversion of a portion of the existing building into a restaurant use
and allow for the remainder of the building to be used as offices ace.
GENERAL LOCATION OR ADDRESS: 9222 Stagecoach Road
OWNED BY/APPLICANT: Eric Nelson Moses, Tucker Partners Agent 501.951.1802
NOTICE IS HEREBY GIVEN THAT an application for a Planned Zoning Development of
the above property has been filed with the Department of Planning and Development. A
public hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on May 17,
2018 at 4:00 P.M. This notice is provided in order to assure that neighborhood
associations are aware of issues that may affect their neighborhood. Information
requests should be directed to the Planning staff at 371-4790.
Jamie Collins
Director of Planning and Development
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF
LAND
April 12, 2018
Wedgewood Creek Homeowners Association
Floyd Cooper
76 Wedgeside Dr
Little Rock, AR 72210
REQUEST: Stagecoach Village Lot 1 Revised Short -form POD Z -6178-K a
request to allow the conversion of a portion of the existing building into a restaurant use
and allow for the remainder of the building to be used as offices ace.
GENERAL LOCATION OR ADDRESS: 9222 Stagecoach Road
OWNED BY/APPLICANT: Eric Nelson. Moses. Tucker Partners Agent 501.951.1802
NOTICE IS HEREBY GIVEN THAT an application for a Planned Zoning Develo ment of
the above property has been filed with the Department of Planning and Development. A
public hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on May 17,
2018 at 4:00 P.M. This notice is provided in order to assure that neighborhood
associations are aware of issues that may affect their neighborhood. Information
requests should be directed to the Planning staff at 371-4790.
Jamie Collins
Director of Planning and Development
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF
LAND
April 12, 2018
South West Little Rock United for Progress
Troy Laha
6602 Baseline Rd, Ste E
Little Rock, AR 72209
REQUEST: Stagecoach Village Lot 1 Revised Short -form POD Z -6178-K a
request to allow the conversion of a portion of the existing building into a restaurant use
and allow for the remainder of the building to be usod as office space.
GENERAL LOCATION OR ADDRESS: 9222 Stagecoach Road
OWNED BY/APPLICANT: Eric Nelson. Moses. Tucker Partners Agent 501.951.1802)
NOTICE IS HEREBY GIVEN THAT an application for a Planned Zoning Development of
the above property has been filed with the Department of Planning and Development. A
public hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on May 17,
2018 at 4:00 P.M. This notice is provided in order to assure that neighborhood
associations are aware of issues that may affect their neighborhood. Information
requests should be directed to the Planning staff at 371-4790.
Jamie Collins
Director of Planning and Development
Public Works Review Comments
Planning Commission Board of Adjustment
Agenda Date: 5-17-18
Z File Number S-1811
LaMarche Village Pre Plat 16307 Taylor Loop Road at LaMarche Drive
1 A 20 feet radial dedication of right-of-way is required at the intersection of LaMarche Drive and Taylor
Loop Road.
2 Taylor Loop Road is classified on the Master Street Plan as a collector street. A dedication of right-
of-way 30 feet from centerline or to the back of the sidewalk, whichever is larger, will be required.
3 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
4 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
5 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
6 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan. Maintenance of the detention pond and all private drainage
improvements is the responsibility of the developer and/or property owner association.
7 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
8 The driveway should be configured to intersect Taylor Loop Road at a right angle.
9 If gates are proposed show location of gates and call box with turnaround.
10 Hauling of fill material on or off site over municipal streets and roads requires approval prior to a
grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501)
379-1805 (Travis Herbner) for more information.
11 Garbage collection trucks cannot maneuver the proposed radiuses for pick up. The radiuses should be
revised to pass a SU -30 vehicle. No residential waste collection service will be provided on private
streets unless the property owners association provides a waiver of damage claims for operations on
private property.
12 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
13 Alteration of the water course will require approval from the Little Rock District of the US Army
Corps of Engineers prior to start of work.
14 A portion of lot 11 shows to extend over the public sidewalk. Lot 11 should be moved further south
to provide additional unobstructed sight distance at the intersection.
15 The plat should reflect On -Street Parking restricted on the eastside of LaMarche Drive adjacent to the
subdivision.
Monday, April 23, 2018 Page I of 9
16 The construction and water easement labeling are not correct on the site plan.
17 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. The proposed driveway should be located at least 250 ft from the LaMarche
Drive/Taylor Loop Road intersection.
Z File Number 5-1812
Rowanwood Subdivision Site Plan Review 2700-3300 S. Shackleford Rd
1 Shackleford Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-
way 45 feet from centerline or back of the new sidewalk will be required.
2 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Shackleford Rd including 5 -foot sidewalks with planned development.
The new back of curb should be located 59 ft from west curb line. Striping should be provided
for
a lane shift and left turn lane into site and Shackleford Pass with tapers Additional paving and
striping beyond the property line maybe needed for turn lane tapers to meet AASHTO and
MUTCD standards. Half street improvements should be made to Shackleford Rd adjacent to
the
subject property. The existing culvert under Shackleford Road should be lengthened. Provide a
revised plan showing the existing and proposed street and drainage improvements, driveways,
intersecting streets, and striping.
3 Private access is proposed for these lots. In accordance with section 31-207, private streets must be
designed to the same standards as public streets. A minimum access easement width of 45' is
required and street width of 24' from back of curb to back
4 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction. Is an advanced
grading permit being requested to grade and clear Phase 2 with the issuance of a grading permit for
5 Provide a grading and drainage plan showing the centerline of the creek, label elevations, and provide
clearer labeling text. Slopes show to exceed 3:1. A variance should be requested for slopes that
exceed 3:1. Clearly show the areas in need of a slope variance. What is the proposed stabilization
method for slopes that exceed 3:1.
6 Storm water detention ordinance applies to this property. Maintenance of the detention pond and all
private drainage improvements is the responsibility of the developer and/or property owner. Concrete
trickle channels are suggested to be constructed within the detention pond for ease of maintenance
and to reduce ponding.
7 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
8 Alteration of the water course will require approval from the Little Rock District of the US Army
Corps of Engineers prior to start of work.
9 Show locations of streets and driveways on the west side of Shackleford Road.
10 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Greg Simmons) for more info.
11 Hauling of fill material on or off site over municipal streets and roads requires approval prior to a
grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501)
379-1805 (Travis Herbner) for more information.
12 The private street shall be constructed with a concrete apron.
Page 2 of 9
Monday, April 23, 2018
13 In accordance with Section 32-8, no obstruction to visibility shall be located within a triangular area
from the intersecting right-of-way line (or intersecting tangent lines for radial dedications) at the
intersection of Rowanwood Drive with Shackleford Road. This intersection is less than a 90 degree
angle.
14 Per the Master Street Plan, parking is restricted to one side of the street on a 24 ft wide street. Show
on the plan now and on the final plat and bill of assurance, the area along the private streets where
parking is restricted.
15 No residential waste collection service will be provided on private streets unless the property owners
association provides a waiver of damage claims for operations on private property. For collection
service in the rear alleys, the alley pavement must be at least 20 ft wide and the receptacles taken to 1
side of the alley.
16 Traffic calming devices are required for long straight streets to discourage speeding. Traffic circles,
round -a -bouts, speed tables, and narrowing are suggested at regular intervals and at main
intersections. Contact Travis Herbner, Traffic Engr. At 379-1805 for additional info. Show the
proposed devices and locations.
17 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
18 Retaining walls designed to exceed 15 ft in height are required to seek a variance for construction.
Provide proposed wall elevations.
19 Prior to construction of retaining walls, a engineer's certification of design and plans must be
submitted to Public Works for approval. After construction, an as -built certification is required for
construction of the retaining wall.
20 A minimum undisturbed strip 25 ft wide except for reasonable access shall be provided along each
side of streams having a 10 yr storm >150 cfs. The undisturbed strip should be measured from the
top of the bank. Provide the 10 storm flow.
21 The owner and/or manager of each multi -family residence of 100 or more dwelling units shall provide
recycling and encourage participation by the tenants, renters, or owners of each unit. Contact
Melinda Glasgow at 371-4646 for more information.
22 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
23 Show proposed location(s) of USPS cluster box units in conformance with USPS and City of Little
Rock policy design standards.
24 Submit a Traffic Impact Study for the proposed project. Study should address trip generation and trip
distribution for the development and also should take into account existing and projected traffic
growth.
25 Show driveway location for Phase 2.
Z File Number S-1813
Giving In Kindness in Ark Subd Site Plan Review 5816 Geyer Springs Cutoff
1 Geyer Springs Road is classified on the Master Street Plan as a minor arterial. A dedication of right-
of-way 45 feet from centerline will be required.
2 Geyer Springs Cutoff is classified on the Master Street Plan as a minor arterial. A dedication of right-
of-way 45 feet from centerline will be required.
Monday, April 23, 2018 Page 3 of 9
3 A 75 feet radial dedication of right-of-way is required at the intersection of Geyer Springs Rd and
Geyer Springs Cutoff per the Master Street Plan.
4 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Geyer Springs Road including 5 -foot sidewalks with planned
development. The new back of curb should be located 29.5 ft from centerline. A left turn lane and
taper section may be required to be provided with construction.
5 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Geyer Springs Cutoff including 5 -foot sidewalks with planned
development. The new back of curb should be located 29.5 ft from centerline.
6 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan. Maintenance of the detention pond and all private drainage
improvements is the responsibility of the developer and/or land owner to maintain.
All driveways shall be concrete aprons per City Ordinance.
8 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Greg Simmons) for more info.
9 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. Driveways should be located at least 150 ft from side property lines and 300 ft
from arterial/arterial intersections. Neither driveway location conforms with code. Variances must be
requested for the driveway locations. The width of driveway must not exceed 36 feet.
10 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the
driveways comply with 2004 AASHTO Green Book standards. The sight distance appears to be
insufficient at the Geyer Springs Cutoff driveway.
Z File Number 5-1814
4624 Willow Springs Road Subdivision Site Plan 4624 Willow Springs Road
1 Willows Springs Road is classified on the Master Street Plan as a collector street. A dedication of
right-of-way 30 feet from centerline will be required.
2 Show the proposed driveway location for the new home if separate from the existing driveway.
Z File Number S-1815
Akins Subdivision Site Plan Review - Acc. Building 4004 Frazier Pike - College Station
1 Frazier Pike is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way
45 feet from centerline will be required.
2 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Frazier Pike including 5 -foot sidewalks with planned development.
The new back of curb should be located 29.5 ft from centerline.
Z File Number Z -5309-A
2712 Kavanaugh PCD
2712 Kavanaugh Blvd & 703 Beechwood St.
1 Due to the proposed use of the property, the Master Street Plan specifies that Beechwood Street for
the frontage of this property must meet commercial street standards. Dedicate right-of-way to 30 feet
from centerline.
Monday, April 23, 2018 Page 4 of 9
2 A 20 feet radial dedication of right-of-way is required at the intersection of Beechwood St. and
Kavanaugh St.
3 Repair or replace any curb and gutter or sidewalk that is damaged and not in compliance with ADA
recommendations in the public right-of-way prior to occupancy.
4 Parking off alley should be at 45 degrees due to the lack of width in the alley.
5 The existing curb cuts on Kavanaugh Blvd should be closed with new curb and gutter as shown on
plan.
6 Along the property frontage, sidewalks and access ramps should be brought up to the current ADA
standards.
7 A healthy elm tree identied in the Beechwood St. right-of-way off the subject property is targeted to
be removed as a result of this project. The CLR Urban Forester objects to the removal of this tree.
With the driveway being moved to accommodate the tree, considerations should be given to
protecting the tree including the roots during construction.
8 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
9 The existing alley should be overlaid with asphalt adjacent to subject property.
10 Show on plan the parking pad for the food truck. Provide detail of the proposed food truck driveway
for more clarification.
11 The intersection of Kavanaugh Ave/Beechwood St. should be improved by providing a 10 ft radius
with the replacement of the access ramps and installation of new curb.
Z File Number Z -6178-K
Stagecoach Village Lot 1 POD
9222 Stagecoach Road
1 Repair or replace any curb and gutter or sidewalk that is damaged and not in compliance with ADA
recommendations in the public right-of-way prior to occupancy.
2 A the time lot 1 develops, the driveway off Stagecoach Rd should be relocated to the shared property
line between lots 1 and 2. The 2nd driveway is off Stagecoach Village Drive.
3 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan. Maintenance of the detention pond and all private drainage
improvements is the responsibility of the developer and/or land owner.
4 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI.
5 Sidewalks with appropriate handicap ramps are required to be constructed along the entire Stagecoach
Road frontage adjacent to lots 1 and 2 with the relocation of the driveway in accordance with Sec. 31-
175 of the Little Rock Code and the Master Street Plan.
Z File Number Z -8278-A
The District at Midtown PCD
NWC University Ave and I-630
1 Due to the proposed use of the property, the Master Street Plan specifies that Midtown Ave for the
frontage of this property must meet commercial street standards. Dedicate right-of-way to 30 feet from
centerline.
2 University Ave. is classified on the Master Street Plan as a principal arterial. Dedication of right-of-
way to 55 feet from centerline will be required.
Monday, April 23, 2018 Page 5 of 9
3 The proposed private streets should be constructed with concrete aprons per City Ordinance.
4 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
5 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI.
6 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
7 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e). Show location of existing
stormwater piping across the property.
8 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
9 Street Improvement plans shall include signage and striping. Public Works must approve completed
plans prior to construction.
10 Hauling of fill material on or off site over municipal streets and roads requires approval prior to a
grading permit being issued. Contact Public Works Traffic. Engineering at 621 S. Broadway, (501)
379-1805 (Travis Herbner) for more information.
11 Due to the disconnection of Sixth Street, another name should be used instead. Street names and
street naming conventions must be approved by Public Works. Contact Glenn Haley at (501) 371-
4537.
12 Coordinate design of traffic signal upgrade with proposed street improvements. Plans to be forwarded
to Traffic Engineering for approval.
13 Submit a Traffic Impact Study for the proposed project. Study should address trip generation and trip
distribution for the development and also should take into account existing and projected traffic
growth.
14 Traffic calming devices are required for long straight streets to discourage speeding. Traffic circles,
round -abouts, pedestrian tables, and narrowing are suggested at regular intervals and at main
intersections. Contact Travis Herbner, Traffic Engr. at 379-1805 for additional info. Provide detail of
proposed traffic calming devices proposed to be used.
15 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
16 Retaining walls designed to exceed 15 ft in height are required to seek a variance for construction.
Provide proposed wall elevations.
17 Prior to construction of retaining walls, a engineer's certification of design and plans must be
submitted to Public Works for approval. After construction, an as -built certification is required for
construction of the retaining wall.
18 Show proposed location(s) of USPS cluster box units in conformance with USPS and City of Little
Rock policy design standards.
Z File Number Z-9319
PB General Holdings, LR Col Glenn PCD 9601 Colonel Glenn Road
1 Colonel Glenn Road is classified on the Master Street Plan as a principal arterial. Dedication of right-
of-way to 55 feet from centerline will be required.
Monday, April 23, 2018 Page 6 of 9
2 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to these streets including 5 -foot sidewalks with planned development.
The new back of curb should be located 29.5 ft from centerline. A payment should be made in -lieu of
construction with Colonel Glenn Rd being controlled by ARDOT.
3 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
4 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI.
5 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
6 Storm water detention ordinance applies to this property.
7 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
8 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the
intersection(s) comply with 2004 AASHTO Green Book standards.
9 Identify the bold red line on the site plan.
10 Show the delivery truck maneuvering route on site.
Z File Number Z-9320
Gramercy Park PD -R 6400 W. Markham St. -NWC Markham & McKinley St.
1 W. Markham St. is classified on the Master Street Plan as a minor arterial. A dedication of right-of-
way 45 feet from centerline will be required.
2 A 20 feet radial dedication of right-of-way is required at the intersection of W. Markham St. and
McKinley St.
3 Sidewalks with appropriate handicap ramps are required to be installed adjacent to McKinley St. in
accordance with Sec. 31-175 of the Little Rock Code and the Master Street Plan.
4 Repair or replace any curb and gutter or sidewalk that is damaged and not within ADA compliance in
the public right-of-way prior to occupancy.
5 No residential waste collection service will be provided on private streets unless the property owners
association provides a waiver of damage claims for operations on private property. Due to an
insufficient turnaround provided within the site, the waste receptacle should be taken to McKinley St.
6 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
7 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. Driveway/access easement spacing on commercial streets is 250 ft from
intersections and other driveways and 125 ft from side property lines. Staff believes the proposed
access easement is located to close to the signalize Markham St./McKinley St. intersection (100 ft).
A variance should be requested for the driveway/access easement location.
8 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. Driveway/access easement spacing on commercial streets is 250 ft from
intersections and other driveways and 125 ft from side property lines. Staff believes the proposed
access easement located to close to the signalize Markham St./McKinley St. intersection (100 ft). A
variance should be requested for the driveway/access easement location.
Monday, April 23, 2018 Page 7 of 9
9 All driveways/access easements shall be constructed with concrete aprons per City Ordinance.
10 No residential waste collection service will be provided on private streets unless the property owners
association provides a waiver of damage claims for operations on private property.
11 Show proposed location(s) of USPS cluster box units in conformance with USPS and City of Little
Rock policy design standards.
12 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
13 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
14 Remove existing curb cuts not planned to be used with proposed development.
15 Are gates proposed to be erected?
Z File Number Z-9321
Calhoun PD -R 4208 Fairview Road
0 No comments
Z File Number Z-9322
Townhouse Apartments PD -R 15901 Taylor Loop Road
1 Taylor Loop Road is classified on the Master Street Plan as a collector street. A, dedication of right-
of-way 30 feet from centerline will be required.
2 Due to the proposed use of the property, the Master Street Plan specifies that Gooch Road for the
frontage of this property must meet commercial street standards. Dedicate right-of-way to 30 feet from
centerline.
3 A 20 feet radial dedication of right-of-way is required at the intersection of Taylor Loop Road and
Gooch Road.
4 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
5 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e). The subject property floods several
times per year. The recently completed Taylor Loop Road Street Widening project did not alleviate
the flooding of this property.
6 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Gooch Road including 5 -foot sidewalks with planned development.
The new back of curb should be located 15.5 ft from centerline.
7 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
8 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan. Maintenance of the detention pond and all private drainage
improvements is the responsibility of the developer and/or property owner's association.
9 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
Monday, April 23, 2018 Page 8 of 9
10 Hauling of fill material on or off site over municipal streets and roads requires approval prior to a
grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501)
379-1805 (Travis Herbner) for more information.
11 No residential waste collection service will be provided on private streets unless the property owners
association provides a waiver of damage claims for operations on private property. For City of Little
Rock service within the site a turnaround must be provided of sufficient size for CLR trash trucks or
the trash receptacles should be taken to Gooch Road.
12 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
13 Show proposed location(s) of USPS cluster box units in conformance with USPS and City of Little
Rock policy design standards.
Z File Number Z-9323
818 W Capitol PCD 818 W. Capitol Ave.
1 A 20 feet radial dedication of right-of-way is required at the intersection of W. Capitol Ave and Izard
St.
2 Repair or replace any curb and gutter or sidewalk that is damaged and not in compliance with ADA
recommendations in the public right-of-way prior to occupancy.
Monday, April 23, 2018 Page 9 of 9
NAME
PLANNING COMMISSION REVIEW
CENTRAL ARKANSAS WATER
17 May 2018
TYPEISSUE
COMMENTS
THE DISTRICT AT MIDTOOWN Z -8278-A All Central Arkansas Water requirements in
LONG -FORM PCD effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
NAME TYPE ISSUE COMMENTS
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
2
NAME TYPE ISSUE COMMENTS
2712 KAVANAUGH SHORT- Z -5309-A
FORM PCD
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review,
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges_ This
fee will apply to all connections including
metered connections off the private fire
system.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
3
NAME TYPE ISSUE COMMENTS
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
4
NAME
TYPE ISSUE COMMENTS
STAGECOACH VILLAGE LOT 1 Z -6178-G
REVISED SHORT FORM POD
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public anti/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZ4,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
5
NAME TYPE ISSUE COMMENTS
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
6
NAME
PB GENERAL HOLDINGS, LR
COLONEL GLENN, SHORT -
FORM PCD
TYPEISSUE
A-9319
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
7
NAME TYPE ISSUE
GRAMMERCY PARK SHORT- Z-9320
FORM PD -R
COMMENTS
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Please submit plans for water facilities to
Central Arkansas Water for review. Plan
revisions may be required after additional
review. Contact Central Arkansas Water
regarding procedures for installation of water
facilities. Approval of plans by Central
Arkansas Water, the Arkansas Department
of Health Engineering Division and Little
Rock Fire Department is required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to
obtain information regarding the required
placement of the hydrant(s) and contact
Central Arkansas Water regarding
procedures for installation of the hydrant(s).
h
NAME TYPE ISSUE COMMENTS
TOWNHOUSE APARTMENTS Z-9322 All Central Arkansas Water requirements in
SHORT -FORM PD -R effect at the time of request for water service
must be met.
Please submit plans for water facilities to
Central Arkansas Water for review. Plan
revisions may be required after additional
review. Contact Central Arkansas Water
regarding procedures for installation of water
facilities_ Approval of plans by Central
Arkansas Water, the Arkansas Department
of Health Engineering Division and Little
Rock Fire Department is required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to
obtain information regarding the required
placement of the hydrant(s) and contact
Central Arkansas Water regarding
procedures for installation of the hydrant(s).
NAME
818 WEST CAPITOL SHORT -
FORM PCD
TYPE ISSUE COMMENTS
Z-9323 All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
10
NAME TYPE ISSUE COMMENTS
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow, preventer shall be
required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
CALHOUN SHORT -FORM PDR Z-9321 All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Please submit plans for water facilities to
Central Arkansas Water for review. Plan
revisions may be required after additional
review. Contact Central Arkansas Water
regarding procedures for installation of water
facilities. Approval of plans by Central
Arkansas Water, the Arkansas Department
of Health Engineering Division and Little
Rock Fire Department is required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to
obtain information regarding the required
placement of the hydrant(s) and contact
Central Arkansas Water regarding
procedures for installation of the hydrant(s).
AKINS SUBDIVISION SITE PLAN S-1815 NO OBJECTION
REVIEW
11
NAME
4264 WILLOW SPRINGS ROAD
SUBDIVISION SITE PLAN
REVIEW
TYPE ISSUE COMMENTS
S-1814 All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Please submit plans for water facilities to
Central Arkansas Water for review. Plan
revisions may be required after additional
review. Contact Central Arkansas Water
regarding procedures for installation of water
facilities. Approval of plans by Central
Arkansas Water, the Arkansas Department
of Health Engineering Division and Little
Rock Fire Department is required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to
obtain information regarding the required
placement of the hydrant(s) and contact
Central Arkansas Water regarding
procedures for installation of the hydrant(s).
12
NAME TYPEISSUE
GIVING IN KINDNESS IN S-1813
ARKANSAS SUPDIVISION SITE
PLAN REVIEW
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A main extension will be required for this
project.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZ4,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
13
NAME
ROWANWOOD SUBDIVISION
SITE PLAN REVIEW
TYPE ISSUE COMMENTS
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
S-1812 All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Please submit plans for water facilities to
Central Arkansas Water for review. Plan
revisions may be required after additional
review. Contact Central Arkansas Water
regarding procedures for installation of water
facilities. Approval of plans by Central
Arkansas Water, the Arkansas Department
of Health Engineering Division and Little
Rock Fire Department is required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to
obtain information regarding the required
placement of the hydrant(s) and contact
Central Arkansas Water regarding
procedures for installation of the hydrant(s).
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges.
14
NAME TYPE ISSUE COMMENTS
LAMARCHE VILLAGE S-1811 All Central Arkansas Water requirements in
PRELIMINARY PLAT effect at the time of request for water service
must be met.
Please submit plans for water facilities to
Central Arkansas Water for review. Plan
revisions may be required after additional
review. Contact Central Arkansas Water
regarding procedures for installation of water
facilities. Approval of plans by Central
Arkansas Water, the Arkansas Department
of Health Engineering Division and Little
Rock Fire Department is required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to
obtain information regarding the required
placement of the hydrant(s) and contact
Central Arkansas Water regarding
procedures for installation of the hydrant(s).
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges.
15
Rock Region METRO comments
The District at Midtown
METRO requests including transit into the design of the project as a means of improving service to our
residents as well as improved transportation options to the District at Midtown and the Midtown area
as a whole. We are concerned about the impacts of this project on our routes and our Midtown bus hub.
METRO is excited to see significant measures have been taken to include pedestrian infrastructure in
this project. Still, we have questions about the nature of the sidewalk and crosswalk plans.
METRO's second largest hub, which had 121,769 boardings in 2017 (339 per day), is located on Midtown
Ave, adjacent to the project site. Five routes serve the hub, including the 3 -Baptist Medical Center, 5 -
West Markham, 8 -Rodney Parham, 9 West Central/ John Barrow Rd, and 22- University Avenue/
Mabelvale routes. 305 buses pass through the hub every weekday.
We at METRO see this project as an excellent opportunity to reenvision our second busiest location as
an integral part of the Midtown area. The creation of a regional bus hub in Midtown will bring significant
economic, social, and environmental benefits to this project, including providing a geographically fixed
customer base, increased amounts of physical activity among residents, and decreased per capita on-
site emissions.
The current plan causes us great concern over potential impacts to transit service. Three METRO routes
(3, 9, and 22) are aligned along 6th Street through the proposed project site. Not only would construction
disrupt these routes, according to current plans there is no provision for buses along 6th St after the
completion of construction. METRO requests that the plans be amended to allow continued service
through the site for these routes.
METRO greatly appreciates the project's inclusion of sidewalks leading from Midtown Ave into the
property. We are concerned about the steep slope of the landscape between Midtown Ave and the
properties, and in particular how people with wheelchairs will be able to navigate this slope.
METRO suggests improving upon the current plan by adding striping at all pedestrian crossings. It is
great to see striping included at some crossings, but comprehensive striping throughout the site is
preferable.
We would like to suggest, as well, an expansion of the pavement of the proposed 5 -foot sidewalk along
the south side of the new 6th St to include the 4 feet currently reserved for grass. Creating a pedestrian
through -route through the property would allow for an extension of the pedestrian/bike path that
already abuts the western edge of the property. Having a direct pedestrian path from areas to the west,
including Kanis Park, to areas to the east, including St. Vincent's hospital, would be a huge asset to the
neighborhood.
9601 Colonel Glenn Rd:
Suggest adding a sidewalk along Colonel Glenn, as well as one connecting the road to the proposed
business
6400 W Markham St:
Suggest improving sidewalk on Markham, including a new sidewalk on McKinley, as well as sidewalk
access to individual homes
15901 Taylor Loop Rd:
Suggest constructing sidewalk on Gooch Rd
818 W Capitol:
Suggest improving cracked sidewalk on Capitol Ave
16307 Taylor Loop Rd:
Suggest including sidewalk on Lamarche Dr
James, Donna
From: Jim Cranor <jcranor@pulaskicounty.net>
Sent: Friday, April 20, 2018 8:30 AM
To: James, Donna
Cc: Van McClendon
Subject: County comments for 5-1813, 5-1814, and 5-1815
Donna,
Pulaski County comments as follows:
S-1813 -Dedicate Right of Way to meet the Little Rock Master Street Plan on both Geyer Springs Road and
Geyer Springs Cut-off.
-Provide perc test prior to Pulaski County Planning prior to requesting a 911 address if the new facility
has restroom facilities.
-Show FEMA flood panel on survey
-Provide approval letter from the N.E. Saline Volunteer Fire Department.
5-1814 -Dedicate Right of Way to meet the Little Rock Master Street Plan for Willow Springs Road.
-Provide perc test prior to Pulaski County Planning prior to requesting a 911 address.
-Provide approval letter from the Arch Street Volunteer Fire Department.
5-1815 -Dedicate Right of Way to meet the Little Rock Master Street Plan for Frazier Pike.
-Proposed building is within the platted building setback line and is also over the property line.
- Provide approval letter from the Sweet Home Volunteer Fire Department.
Feel free to call if you have any further questions.
Thanks,
Jim
Jim Cranor RLA, CFM
Pulaski County Planning and Development
3200 Brown Street
Little Rock, AR 72204
501-340-8265
MEMORANDUM
TO: DONNA JAMES, SUBDIVISION ADMINISTRATOR
FROM: TRACY SPILLMAN, PLANS DEVELOPMENT ADMINISTRATOR
SUBJECT: REVIEW OF THE BUFFER AND LANDSCAPE REQUIREMENTS OF
THE APRIL 25, 2018, SUBDIVISION COMMITTEE MEETING
CC: DANA CARNEY, ZONING & SUBDIVISION MANAGER
DATE: APRIL 20, 2018
1. 16307 Ta for Loop Road$ -1811
No comment.
2. 2700 —3300 Block of South Shackleford Road S-1812
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
The City Beautiful Commission recominends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
3. 5816 Geyer S rin s Road S-1813
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
4. 4624 Willow S rin s Road S-1814
No comment.
5. 4004 Frazier Park S-1815
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
6. 2712 Kavanaugh Blvd and 703_ Beachwood Street (,Z -5309-A)
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements and the requirements of the Hillcrest Design Overlay District.
Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half ('/2) the full width requirement but in no case less
than nine (9) feet. In addition to the required screening, buffers are to be landscaped at
the rate of one (1) tree and three (3) shrubs for every thirty (30) linear feet. The property
is located in the City's designated mature area. A twenty-five (25%) percent reduction of
the buffer width requirements is acceptable.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
A land use buffer six (6) percent of the average width / depth of the lot will be required
when an adjacent property has a dissimilar use of a more restrictive nature. The property
to the north is zoned PD -R. As a component of all land use buffer requirements, opaque
screening, whether a fence or other device, a minimum of six (6) feet in height shall be
required upon the property line side of the buffer. In addition to the required screening,
buffers are to be landscaped at the rate of one (1) tree and three (3) shrubs for every
thirty (30) linear feet.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property, or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30)
linear feet of perimeter planting strip. A twenty-five (25%) percent reduction of the
perimeter width requirements is acceptable. The minimum perimeter width adjacent to
the north property line shall be six (6) feet nine (9) inches. The north perimeter is
deficient and may require a variance from the City Beautiful Commission.
Building landscape areas shall be provided at the rate equivalent to planter strip three (3)
feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in
the building landscape areas for each forty (40) linear feet of vehicular use area abutting
the building.
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The minimum
size of an interior landscape area shall be one hundred fifty (15 0) square feet for
developments with one hundred fifty (15 0) or fewer parking spaces. Interior islands must
be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in the
interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces.
A landscape irrigation system shall be required for developments of one (1) acre or
larger.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
7. 9222 Sta ecoach Road Z -6178-K
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements.
Any new building rehabilitation or expansion may require the existing landscaping,
buffer, or vehicular use areas not meeting the current code requirements to be
brought into compliance.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
8. 600 South University (Z -7278-A
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements.
Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half ('/2) the full width requirement but in no case less
than nine (9) feet.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property, or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. The perimeter planting strip adjacent to freeways or expressways shall be at
least thirty (30) feet wide One (1) tree and three (3) shrubs or vines shall be planted for
every thirty (30) linear feet of perimeter planting strip. Perimeter plantings are to be
provided from the property line adjacent to the street right-of-way up to the front
building line in industrial properties. The perimeter planting strip adjacent to the I-630
right-of-way is deficient.
Land use buffers are to be maintained adjacent to the west R-5 zoned properties. As a
component of all land use buffer requirements, opaque screening, whether a fence or
other device, a minimum of six (6) feet in height shall be required upon the property line
side of the buffer. A minimum of seventy (70) percent of the land use buffer shall be
undisturbed. Easements cannot count toward fulfilling this requirement. In addition to
the required screening, buffers are to be landscaped at the rate of one (1) tree and three
(3) shrubs for every thirty (30) linear feet. Existing plant material can be used to meet
these minimum requirements.
Building landscape areas shall be provided at the rate equivalent to planter strip three (3)
feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in
the building landscape areas for each forty (40) linear feet of vehicular use area abutting
the building.
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The minimum
size of an interior landscape area shall be one hundred fifty (15 0) square feet for
developments with one hundred fifty (15 0) or fewer parking spaces. Interior islands must
be a minimum seven and one half (7 1/2) feet in width. Trees shall be included in the
interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces.
A landscape irrigation system shall be required for developments of one (1) acre or
larger.
The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
9. 9601 Colonel Glenn Road Z-9319
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half (1/2) the full width requirement but in no case less
than nine (9) feet.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street, highway or freeway. This strip shall
be at least nine (9) feet wide. Provide trees with an average linear spacing of not less than
thirty (30) feet within the perimeter planting strip. Provide three (3) shrubs or vines for
every thirty (30) linear feet of perimeter planting strip. A portion of the west perimeter
planting strip is deficient.
Landscape areas shall be provided between the vehicular use area used for public parking
and the general vicinity of the building, excluding truck loading or service areas not open
to public parking. These areas shall be equal to an equivalent planter strip three (3) feet
wide along the vehicular use area.
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The minimum
size of an interior landscape area shall be one hundred fifty (150) square feet for
developments with one hundred fifty (150) or fewer parking spaces. Interior islands must
be a minimum seven and one half (7 1/2) feet in width. Trees shall be included in the
interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces.
Land use buffers are to be maintained adjacent to the south and east R-2 zoned
properties. As a component of all land use buffer requirements, opaque screening,
whether a fence or other device, a minimum of six (6) feet in height shall be required
upon the property line side of the buffer. A minimum of seventy (70) percent of the
land use buffer shall be undisturbed. Easements cannot count toward fulfilling this
requirement. In addition to the required screening, buffers are to be landscaped at the
rate of one (1) tree and three (3) shrubs for every thirty (30) linear feet. Existing plant
material can be used to meet these minimum requirements.
A landscape irrigation system shall be required for developments of one (1) acre or
larger.
The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
10. 6400 West Markham St NWC Markham and McKinley Streets Z-9320
No comment.
11.4208 Fairview Rd Z-9321
No comment.
12. 15 901 Ta for Lo2p Road Z-9322
No comment.
13.818 West Ca itol Z-9323
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements and the requirements of the UU Urban Use District.
Any existing vehicular use area that does not meet current code requirements may
continue as nonconforming until such time a building permit is issued to rehabilitate a
structure on the property exceeding fifty (50) percent of the current replacement cost of
the structure. At such time fifty (50) percent of the existing vehicular use area shall be
brought into compliance with this chapter and shall continue to full compliance on a
graduated scale based upon the percentage of rehabilitation cost.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
Z -5309-A
Address: 2712 Kavanaugh
Boulevard and 703
Beachwood Street
Planninq Division: This request is located in Heights Hillcrest Planning District.
The Land Use Plan shows Commercial (C) for these properties. The Commercial
category includes a broad range of retail and wholesale sales of products, personal
and professional services, and general business activities. Commercial activities
vary in type and scale, depending on the trade area that they serve. The applicant
has applied for a rezoning from C3 (General Commercial District) and 03 (General
Office District) to (Planned Commercial Development) to allow a restaurant with
common outdoor space and parking. The request is within the Hillcrest Design
Overlay District.
Master Street Plan: West of the properties is Beechwood Street and it is shown as
a Local Street on the Master Street Plan. South of the properties is Kavanaugh
Boulevard and it is shown as a Collector on the Master Street Plan. The primary
function of a Local Street is to provide access to adjacent properties. Local Streets
that are abutted by non-residential zoning/use or more intensive zoning than
duplexes are considered as "Commercial Streets". A Collector design standard is
used for Commercial Streets. The primary function of a Collector Road is to provide
a connection from Local Streets to Arterials. These streets may require dedication
of right-of-way and may require street improvements for entrances and exits to the
site.
Bicycle Plan: There is a Class III Bike Route shown on Kavanaugh Blvd. These
bike routes require no additional right-of-way, but either a sign or pavement
marking to identify and direct the route.
Z -6178-K Address: 9222 stagecoach
Road
Planning Division: This request is located in Otter Creek Planning District, The
Land Use Plan shows Mixed Use (MX) for this property. The Mixed Use category
provides for a mixture of residential, office, and commercial uses to occur. A
Planned Zoning District is required if the use is entirely office or commercial or if
the use is a mixture of the three. The applicant has applied for a revised Short -
form POD (Planned Office District) to allow for the addition of `restaurant' as a
permitted use in the existing structure.
Master Street Plan: East of the property is Stagecoach Road and it shown as a
Minor Arterial on the Master Street Plan. South of the property is Stagecoach
Village Drive and it is shown as a proposed Local Street on the Master Street
Plan. A Minor Arterial provides connections to and through an urban area and
their primary function is to provide short distance travel within the urbanized area.
Entrances and exits should be limited to minimize negative effects of traffic and
pedestrians on Stagecoach Road. The primary function of a Local Street is to
provide access to adjacent properties. Local Streets that are abutted by non-
residential zoning/use or more intensive zoning than duplexes are considered as
"Commercial Streets". A Collector design standard is used for Commercial
Streets. These streets may require dedication of right-of-way and may require
street improvements for entrances and exits to the site.
Bicycle_ Plan: A Class II Bike Lane is shown along Stagecoach Road. Bike Lanes
provide a portion of the pavement for the sole use of bicycles.
Z -8278-A
Address: 600 South
University Avenue — NWC
of University Avenue and 1-
630
Planning Division: This request is located in West Little Rock Planning District. .
The Land Use Plan shows Mixed Use (MX) for this property. The Mixed Use
category provides for a mixture of residential, office, and commercial uses to occur.
A Planned Zoning District is required if the use is entirely office or commercial or if
the use is a mixture of the three. The applicant has applied for a rezoning from
PCD (Planned Commercial District) and C3 (General Commercial District) to PCD
(Planned Commercial Development) to allow commercial and office development.
The request is within the Midtown Design Overlay District
Master Street Plan: Midtown Ave and West est Street and S McKinley Street are
all shown as Local Streets on the Master Street Plan. East of the properties is S
University Avenue and it shown as a Principal Arterial on the Master Street Plan.
South of the properties is Interstate 630 and it is shown and a Freeway on the
Master Street Plan. The primary function of a Local Street is to provide access to
adjacent properties. Local Streets that are abutted by non-residential zoning/use
or more intensive zoning than duplexes are considered as "Commercial Streets".
A Collector design standard is used for Commercial Streets. The primary function
of a Principal Arterial Street is to serve through traffic and to connect major traffic
generator or activity centers within an urbanized area. Entrances and exits should
be limited to minimize negative effects of traffic and pedestrians on S University
Avenue since it is a Principal Arterial. The primary function of a Freeway is to serve
through long distance trips. Freeways are always designed as full access control
roads (no direct access) Entrances and exits should be limited to minimize
negative effects of traffic and pedestrians on 1-630 since it is a Freeway. These
streets may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
Bicycle Plan: There is a Class III Bike Route shown on Midtown Avenue. These
bike routes require no additional right-of-way, but either a sign or pavement
marking to identify and direct the route.
Z-9319 Address: 9601 Colonel
Glenn Road
Planning Division: This request is located in 65th Street West Planning District.
The Land Use Plan shows Mixed Use (MX) for this property The Mixed Use
category provides for a mixture of residential, office, and commercial uses to occur.
A Planned Zoning District is required if the use is entirely office or commercial or if
the use is a mixture of the three. The applicant has applied for a Rezoning from a
R2 (Single Family District) to a PCD (Planned Commercial Development) to allow
a retail store to be built.
Master Street Plan: North of the property is Colonel Glenn Road and is shown as
a Principal Arterial on the Master Street Plan. The primary function of a Principal
Arterial Street is to serve through traffic and to connect major traffic generator or
activity centers within an urbanized area. Entrances and exits should be limited
to minimize negative effects of traffic and pedestrians on Colonel Glenn Road
since it is a Principal Arterial. This streets may require dedication of right-of-way
and may require street improvements for entrances and exits to the site.
Bicycle Plan: A Class II Bike Lane is shown along Colonel Glenn Road. Bike Lanes
provide a portion of the pavement for the sole use of bicycles.
Z-9320
Address: 6400 West
Markham Street, NWC
Markham and McKinley
Streets
Planning Division: This request is located in West Little Rock Planning District.
The Land Use Plan shows Residential Low Density Use (RL) for this property.
Residential Low category provides for single family homes at densities not to
exceed 6 dwelling units per acre. Such residential development is typically
characterized by conventional single family homes, but may also include patio or
garden homes and cluster homes, provided that the density remain less than 6
units per acre. The applicant has applied for a rezoning from R2 (Single Family
District) to PDR (Planned Development Residential) to allow for 6 Patio Homes on
half an acre (12 units/acre density).
Master Street Plan: South of the property is W Markham Street and it shown as a
Minor Arterial on the Master Street Plan. East of the property is North McKinley
Street and it shown as a Local Street on the Master Street Plan. Minor Arterial
provides connections to and through an urban area and their primary function is
to provide short distance travel within the urbanized area. Entrances and exits
should be limited to minimize negative effects of traffic and pedestrians on W
Markham Street. The primary function of a Local Street is to provide access to
adjacent properties. Local Streets that are abutted by non-residential zoning/use
or more intensive zoning than duplexes are considered as "Commercial Streets".
A Collector design standard is used for Commercial Streets. These streets may
require dedication of right-of-way and may require street improvements for
entrances and exits to the site.
Bicycle Plan_ There are Class III Bike Routes shown on W Markham and North
McKinley Streets. These bike routes require no additional right-of-way, but either
a sign or pavement marking to identify and direct the route.
Z-9321 Address: 4208 Fairview
Road
Planning Division: This request is located in Heights Hillcrest Planning District.
The Land Use Plan shows Residential Low Density Use (RL) for this property.
Residential Low category provides for single family homes at densities not to
exceed 6 dwelling units per acre. Such residential development is typically
characterized by conventional single family homes, but may also include patio or
garden homes and cluster homes, provided that the density remain less than 6
units per acre. The applicant has applied for a rezoning from R2 (Single Family
District) to PDR (Planned Development Residential) to allow an existing 1 story to
be remodeled into a 2 story house. The request is within the Hillcrest Design
Overlay District.
Master Street Plan: West of the property is Fairview Road and it shown as a
Local Street on the Master Street Plan. The primary function of a Local Street is
to provide access to adjacent properties. This Streets may require dedication of
right-of-way and may require street improvements for entrances and exits to the
site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
Z-9322 Address: 15901 Taylor
Loop Road
Planning Division: This request is located in Chenal Planning District. The Land
Use Plan shows Residential Low Density Use (RL) for this property. Residential
Low category provides for single family homes at densities not to exceed 6 dwelling
units per acre. Such residential development is typically characterized by
conventional single family homes, but may also include patio or garden homes and
cluster homes, provided that the density remain less than 6 units per acre. The
applicant has applied for a Rezoning from R2 (Single Family District) to PDR
(Planned Development Residential) to build 8 Townhouses units on 0.9 acres of
land (approximately 9 units/acre).
Master Street Plan: North of the Property is Taylor Loop Road and it shown as a
Collector on the Master Street Plan. West of the property is Gooch Drive and it
shown as a Local Street on the Master Street Plan. This Streets may require
dedication of right-of-way and may require street improvements for entrances
and exits to the site. The primary function of a Collector Road is to provide a
connection from Local Streets to Arterials. The primary function of a Local Street
is to provide access to adjacent properties. A Collector design standard is used
for Commercial Streets. These streets may require dedication of right-of-way
and may require street improvements for entrances and exits to the site.
Bicycle Plan: A Class II Bike Lane is shown along Taylor Loop Road. Bike Lanes
provide a portion of the pavement for the sole use of bicycles.
Z-9323 Address: 818 West Capitol
Planninq Division: This request is located in Downtown Planning District. The Land
Use Plan shows Mixed Use Urban (MXU) for this property. The Mixed Use Urban
category provides for a mix of residential, office and commercial uses not only in
the same block but also within the same structure. This category is intended for
older "urban" areas to allow dissimilar uses to exist, which support each other to
create a vital area. Development should reinforce the urban fabric cresting a 24-
hour activity area. Using the Planned Zoning District or the Urban Use District, high
and moderate density developments that result in a vital (dense) pedestrian
oriented area are appropriate. The applicant has applied for a rezoning from UU
(Urban Use) to PCD (Planned Commercial Development) to allow a private club in
an existing building.
Master Street Plan: South of the property is W Capitol Avenue and it is shown as
a Collector on the Master Street Plan. West of the property is S Izard Street and
it is shown as a Local Street on the Master Street Plan. The primary function of a
Collector Road is to provide a connection from Local Streets to Arterials. The
primary function of a Local Street is to provide access to adjacent properties.
Local Streets that are abutted by non-residential zoning/use or more intensive
zoning than duplexes are considered as "Commercial Streets". A Collector
design standard is used for Commercial Streets. These Streets may require
dedication of right-of-way and may require street improvements. for entrances
and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
En ter
VJ :�
April 17, 2018
City of Little Rock
Department of Planning and Development
ATTN: Ms. Donna James, AICP
723 West Markham Street
Little Rock, AR 72201-1334
RE: Entergy comments related to Planning and Zoning items for the May 17" Meeting
Ms. James,
Entergy Arkansas Inc.
#9 Entergy Court
Little Rock, AR 72211
Please find below Entergy's comments related to the items received from the Department of Planning and
Development this week. The request letter said to have the comments back to you by April 23`d, 2018.
• the District at Midtown — Long -form PCD — 600 So. University Ave. — Z -8278 -AE
Entergy does not object to this proposal. However, there are multiple electrical Distribution power lines
running around and through this property. The lines on the west side and north side of the area are
overhead power lines. There is an underground power line running east and west across the center of the
property along the path of what was previously 6' Street. There is an underground power line running
along the east side of the property beginning on the west side of University and I-630 extending north.
Entergy has met previously with a developer about this property. Contact Entergy in advance to discuss
electrical service requirements, conduit layout, and adjustments to existing facilities (if any) as this
project proceeds.
2712 Kavanaugh Short -form PCD — 2712 Kavanaugh Blvd & 703 Beechwood St.— Z -5309-A
Entergy does not object to this proposal. However, as noted on the Site Plan drawing, there is an existing
three-phase overhead power line running along Kavanaugh in front of this property. All OSHA and Code
clearances to this power line must be maintained during and after construction of the Proposed Building.
There is also a single phase, overhead power line running along the east side of the alley on the east side
of the property. The same clearance requirements exist for this line as well during and after construction.
Lastly, note that the proposed dumpster location must take into account any overhead power lines which
are in the area. Any dumpster handling must maintain at least 10 feet clearance from any overhead line.
Contact Entergy in advance to discuss electrical service requirements, or adjustments to existing facilities
(if any) as this project proceeds.
■ Stagecoach Village Lot 1 Revised short -form POD — 9222 Stagecoach Rd. — Z -6178-K
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. Service is already being provided to the building on Lot 2. There is an overhead,
three phase power line running along the eastern and northern edge of Lot and also along the northern
edge of Lot 3 which will need to be accounted for during future development. Contact Entergy in
advance to discuss electrical service requirements, or adjustments to existing facilities (if any) as this
project proceeds.
PB General Holdings, LR Colonel Glenn short -form PCD — 9601 Colonel Glenn Rd — Z-9319
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. There is an existing three phase, overhead power line on the north side of
Colonel Glenn Road in front of this property. There is also a single phase, overhead power line running
along the east side of the property. Contact Entergy in advance to discuss electrical service requirements,
or adjustments to existing facilities (if any) as this project proceeds.
■ Gramercy Park Short -form PD -R — 6400 West Markham St — Z-9320
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. There is an existing three phase, overhead power line on the west side of
McKinley adjacent to this property. There is also a single phase, overhead power line running east and
west along Gramercy Park drive which will need to remain in place to serve existing Entergy customers
on the west side of this project. Service is already being provided to existing structures in the project area
which will need to be addressed. Contact Entergy in advance to discuss electrical service requirements,
or adjustments to existing facilities (if any) as this project proceeds.
Townhouse Apartments Short -form PD -R —15901 Taylor Loop Rd — Z-9322
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. However, there is a three phase, overhead power on the north side of this
property along Taylor Loop Road and a single phase power line running along the east side of Gooch
Drive. Construction of the project requires that all applicable clearances to the power lines be maintained
during and after construction of the Townhouses. Contact Entergy in advance to discuss electrical service
requirements, or adjustments to existing facilities (if any) as this project proceeds.
• 818 West Capitol Short -form PCD — 818 West Capitol — Z-9323
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. A three phase overhead electrical power line runs along the north side of the
property across the alley. Service is already provided to the existing building. Contact Entergy in
advance to discuss electrical service requirements, or adjustments to existing facilities (if any) as this
project proceeds.
• Calhoun Short -form PD -R — 4208 Fairview Road — Z-9321
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. Service is already provided via an underground service line to the existing
building. Contact Entergy in advance to discuss electrical service requirements, or adjustments to
existing facilities (if any) as this project proceeds.
■ Akins Subdivision Site Plan Review — 4008 Frazier Pike College Sta. — S-1815
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. Service is already provided via an overhead service line to the existing building.
Contact Entergy in advance to discuss electrical service requirements, or adjustments to existing facilities
(if any) as this project proceeds.
■ 4624 Willow Springs Rd Subdivision Site Plan Review — 4624 Willow Springs Rd — S-1814
This location is not within Entergy's allocated service territory and believes that it is served by I" Electric
Cooperative..
Giving in Kindness in AR Subdivision Site Plan Review — 5816 Geyer Springs Rd. — S-1813
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. Service is already provided via an underground service line to the existing
buildings. An overhead power line, pole and transformer exists on the south side of the property. Contact
Entergy in advance to discuss electrical service requirements, or adjustments to existing facilities (if any)
as this project proceeds.
Rowanwood Subdivision Site Plan Review — E side of So. Shackleford in 2700-3300 Block — S-1812
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. A three phase overhead electrical power line runs along the west side of
Shackelford Road just to the south of this project, and another one exists on Aldersgate Road just to the
east of the project. Contact Entergy in advance to discuss electrical service requirements, or adjustments
to existing facilities (if any) as this project proceeds.
LaMarche Village Preliminary Plat —16307 Taylor Loop Rd. — S-1811
Entergy does not object to this proposal. There are existing overhead, primary electrical facilities located
on this property which will need to be removed prior to the development. A three phase overhead
electrical power line runs along the south side of Taylor Loop Road to the north of this property. Contact
Entergy in advance to discuss electrical service requirements and adjustments to existing facilities as this
project proceeds.
If you need further assistance you may call me at 501-954-5158 or e-mail me at bneumei@entergy.com.
Sincerely,
Bernard Neumeier, P.E.
Region Engineering Supervisor
Entergy Arkansas, Inc.
Little Rock Water Reclamation Authority Comments
Project Number S-1811
Project Name Project Type
LaMarche Village Preliminary Plat
Project Number S-1812
Project Name Project Type
Rowanwood Subdiv Site Multi Bldg site Plan Review
Plan
Project Number 5-1813
Project Name
Project Type
Giving Kindness in
Multi Bldg site Plan Review
Arkansas
Project Number 5-181A.
Project Name
Project Type
4624 Willow Springs Road
Subdiv/Site Plan Review
Subd iv
Project Number 5-181.5
Project Name
Project Type
Akins Subdivision
Subdiv/Site Plan Review
Project Number Z -5309-A
Project Name
Project Type
Kavanaugh PCD
Planned Development: Commercial
Project Number Z -6178-K
Project Name
Stagecoach Village Lot 1
Project Number Z -8278-A
Project Name
The District at Modtown
Comment Made
Sewer main extension required with easements if new
sewer service is required for this project.
Comment Made
Sewer main extension required with easements if new
sewer service is required for this project. Capacity Fee
Analysis required.
Comment Made
Outside Service Boundary- No Comment.
Comment Made
Outside Service Boundary - No Comment.
Comment Made
Sewer Available to this site.
Comment Made
Sewer Available to this site. EAD Review required if
food service on site
Project Type Comment Made
Planned Development: Office Sewer Available to this site. EAD Review required if
food service on site
Project Type Comment Made
Planned Development: Commercial Sewer available. Capacity fee analysis required for
hotels. EAD review required for food service.
Monday, April 16, 2018 Page 1 of 2
Project Number Z-9319
Project Name
Project Type
Comment Made
PB General Holdings -
Planned Development: Commercial
Sewer Available to this site.
9601 Col Glenn
Project Number Z-9320
Project Name
Project Type
Comment Made
Gramercy Park
Planned Development: Residential
Sewer main extension required with easements if new
sewer service is required for this project.
Project Number Z-9321
Project Name
Project Type
Comment Made
Calhoun PD -R
Planned Development: Residential
Sewer Available to this site.
Project Number Z-9322
Project Name
Project Type
Comment Made
Townhouse Apartments
Planned Development: Residential
Sewer main extension required with easements if new
sewer service is required for this project.
Project Number Z-9323
Project Name
Project Type
Comment Made
818 West Capitol
Planned Development: Commercial -
Sewer Available to this site.
Private Club
Monday, April 16, 2018 Page 2 of 2
James, Donna
From:
Rhodes, Tony
Sent:
Tuesday, April 17, 2018 9:38 AM
To:
James, Donna
Cc:
Hogue, John; Salaam, Naim; Ingram, Derek
Subject:
Fire Department Zoning Comments
Cornment for the following Locations:
Z -8278-A- 600 South University Avenue-NWC of University Avenue and
1-630
Full Plan Review
Z -5309-A- 2712 Kavanaugh Boulevard and 703 Beachwood Street
Full Plan Review
Z -6178-K- 9222 Stagecoach Road
Full Plan Review
Z-9319- 9601 Colonel Glenn Road
Full Plan Review
Z-9320- 6400 West Markham Street NWC Markham and McKinle
Streets
Full Plan Review
Z-9322- 15901 Tavlor Loop Road
Full Plan Review
Z-9323- 818 West Capitol
Full Plan Review
Z-9321- 4208 Fairview Road
Access roads
Fire Apparatus Access Roads shall conform to all the requirements of Chapter 5 and Appendix D of the 2012
Arkansas Fire Prevention Code, Vol. 1. Specifically addressed are required access, construction & design
specifications, access road gates, signs, driveway widths of structures with hydrants, aerial fire apparatus access
roads, aerial fire apparatus roads distance to structure, fire lane markings, commercial & industrial
developments, and residential developments. Locations and extent of fire lane markings must be approved by
the fire code official and is subject to change at any time upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Addresses
Addresses shall be posted in a conspicuous place during construction and when construction is complete as per
Little Rock City Ordinance Section 30-346 and Section 505 of the 2012 Arkansas Fire Prevention Code, Vol. 1
to facilitate emergency response. Numbers/Letters shall be Arabic numbers or alphabetic letters to be minimum
6" in height, of a durable, reflective material on a color contrasting background to promote enhanced
visibility. The numbers hall be in a conspicuously placed immediately above, on or at the side of the proper
door of each building so that the number can be seen plainly from the street on which the number is
based. Whenever any building is situated so that the number is not clearly discernible from the street line or
vision of the building from the street is otherwise obscured, the number or numbers assigned shall be placed
near the walk, driveway or common entrance to such buildings, and affixed upon a gate post, fence, mailbox,
post, or other appropriate place so as to be easily discernible (this is in addition to the numbers/letters on the
building). Numbers painted or stenciled on the curb shall not be a lawful substitute for the display of address
numbers prescribed by this article. Subject to change upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Apparatus Access — FDC -hydrant
The LR Fire Department must approve the proposed location of the building's Fire Department Connection
[FDC]. Per 2012 Arkansas Fire Prevention Code, Vol. 1, Section 912.2. With respect to hydrants, driveways,
buildings and landscaping, fire department connections shall be so located that fire apparatus and hose
connected to supply the system will not obstruct access to the buildings for other fire apparatus, this includes
parking spaces in between, and around the FDC and the fire apparatus access road. FDC shall be located on the
street side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle
access or as otherwise approved. A remote FDC is recommended and location must be approved. Signage of at
least 6 inches high, red letters on white background, with "FDC" must be mounted above the FDC to be visible
from fire apparatus access road. Subject to change at any time upon field evaluation. Contact Capt. Tony
Rhodes at (501) 918-3757.
S-1815 — 4004 Frazier Pike College Station
No comments
S-1814-4624 Willow Springs Road
Access roads
Fire Apparatus Access Roads shall conform to all the requirements of Chapter 5 and Appendix D of the 2012
Arkansas Fire Prevention Code, Vol. 1. Specifically addressed are required access, construction & design
specifications, access road gates, signs, driveway widths of structures with hydrants, aerial Fre apparatus access
roads, aerial fire apparatus roads distance to structure, fire lane markings, commercial & industrial
developments, and residential developments. Locations and extent of fire lane markings must be approved by
the fire code official and is subject to change at any time upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Addresses
Addresses shall be posted in a conspicuous place during construction and when construction is complete as per
Little Rock City Ordinance Section 30-346 and Section 505 of the 2012 Arkansas Fire Prevention Code, Vol. 1
to facilitate emergency response. Numbers/Letters shall be Arabic numbers or alphabetic letters to be minimum
6" in height, of a durable, reflective material on a color contrasting background to promote enhanced
visibility. The numbers hall be in a conspicuously placed immediately above, on or at the side of the proper
door of each building so that the number can be seen plainly from the street on which the number is
based. Whenever any building is situated so that the number is not clearly discernible from the street line or
vision of the building from the street is otherwise obscured, the number or numbers assigned shall be placed
near the walk, driveway or common entrance to such buildings, and affixed upon a gate post, fence, mailbox,
post, or other appropriate place so as to be easily discernible (this is in addition to the numbers/letters on the
building). Numbers painted or stenciled on the curb shall not be a lawful substitute for the display of address
numbers prescribed by this article. Subject to change upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Fire Hydrant
The Little Rock Fire Department, Capt. Tony Rhodes (501) 918-3757, needs to evaluate this site to determine
whether additional public and/or private fire hydrants will be required. The installation of any new fire
protection facilities will be at the expense of the project developer. Contact Central Arkansas Water regarding
procedures for installation of the hydrant(s). Subject to change at any time upon field evaluation.
S-1813-5816 Geyer Springs
Full Plans Review
Access roads
Fire Apparatus Access Roads shall conform to all the requirements of Chapter 5 and Appendix D of the 2012
Arkansas Fire Prevention Code, Vol. 1. Specifically addressed are required access, construction & design
specifications, access road gates, signs, driveway widths of structures with hydrants, aerial ire apparatus access
roads, aerial fire apparatus roads distance to structure, fire lane markings, commercial &. industrial
developments, and residential developments. Locations and extent of fire lane markings must be approved by
the fire code official and is subject to change at any time upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Addresses
Addresses shall be posted in a conspicuous place during construction and when construction is complete as per
Little Rock City Ordinance Section 30-346 and Section 505 of the 2012 Arkansas Fire Prevention Code, Vol. 1
to facilitate emergency response. Numbers/Letters shall be Arabic numbers or alphabetic letters to be minimum
6" in height, of a durable, reflective material on a color contrasting background to promote enhanced
visibility. The numbers hall be in a conspicuously placed immediately above, on or at the side of the proper
door of each building so that the number can be seen plainly from the street on which the number is
based. Whenever any building is situated so that the number is not clearly discernible from the street line or
vision of the building from the street is otherwise obscured, the number or numbers assigned shall be placed
near the walk, driveway or common entrance to such buildings, and affixed upon a gate post, fence, mailbox,
post, or other appropriate place so as to be easily discernible (this is in addition to the numbers/letters on the
building). Numbers painted or stenciled on the curb shall not be a lawful substitute for the display of address
numbers prescribed by this article. Subject to change upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Fire Hydrant
The Little Rock Fire Department, Capt. Tony Rhodes (501) 918-3757, needs to evaluate this site to determine
whether additional public and/or private fire hydrants will be required. The installation of any new fire
protection facilities will be at the expense of the project developer. Contact Central Arkansas Water regarding
procedures for installation of the hydrant(s). Subject to change at any time upon field evaluation.
S -1812 -located on the east side of South Shackleford Road in the
2700-3300 Block of Shackleford Road
Access roads
Fire Apparatus Access Roads shall conform to all the requirements of Chapter 5 and Appendix D of the 2012
Arkansas Fire Prevention Code, Vol. 1. Specifically addressed are required access, construction & design
specifications, access road gates, signs, driveway widths of structures with hydrants, aerial fire apparatus access
roads, aerial fire apparatus roads distance to structure, fire lane markings, commercial & industrial
developments, and residential developments. Locations and extent of fire lane markings must be approved by
the fire code official and is subject to change at any time upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Addresses
Addresses shall be posted in a conspicuous place during construction and when construction is complete as per
Little Rock City Ordinance Section 30-346 and Section 505 of the 2012 Arkansas Fire Prevention Code, Vol. 1
to facilitate emergency response. Numbers/Letters shall be Arabic numbers or alphabetic letters to be minimum
6" in height, of a durable, reflective material on a color contrasting background to promote enhanced
visibility. The numbers hall be in a conspicuously placed immediately above, on or at the side of the proper
door of each building so that the number can be seen plainly from the street on which the number is
based. Whenever any building is situated so that the number is not clearly discernible from the street line or
vision of the building from the street is otherwise obscured, the number or numbers assigned shall be placed
near the walk, driveway or common entrance to such buildings, and affixed upon a gate post, fence, mailbox,
post, or other appropriate place so as to be easily discernible (this is in addition to the numbers/letters on the
building). Numbers painted or stenciled on the curb shall not be a lawful substitute for the display of address
numbers prescribed by this article. Subject to change upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Fire Hvdrant
The Little Rock Fire Department, Capt. Tony Rhodes (501) 918-3757, needs to evaluate this site to determine
whether additional public and/or private fire hydrants will be required. The installation of any new fire
protection facilities will be at the expense of the project developer. Contact Central Arkansas Water regarding
procedures for installation of the hydrant(s). Subject to change at any time upon field evaluation.
S-1811- 16307 Ta for Loop Road
Access roads
Fire Apparatus Access Roads shall conform to all the requirements of Chapter 5 and Appendix D of the 2012
Arkansas Fire Prevention Code, Vol. 1. Specifically addressed are required access, construction & design
specifications, access road gates, signs, driveway widths of structures with hydrants, aerial fire apparatus access
roads, aerial fire apparatus roads distance to structure, fire lane markings, commercial & industrial
developments, and residential developments. Locations and extent of fire lane markings must be approved by
the fire code official and is subject to change at any time upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Addresses
Addresses shall be posted in a conspicuous place during construction and when construction is complete as per
Little Rock City Ordinance Section 30-346 and Section 505 of the 2012 Arkansas Fire Prevention Code, Vol. 1
to facilitate emergency response. Numbers/Letters shall be Arabic numbers or alphabetic letters to be minimum
6" in height, of a durable, reflective material on a color contrasting background to promote enhanced
visibility. The numbers hall be in a conspicuously placed immediately above, on or at the side of the proper
door of each building so that the number can be seen plainly from the street on which the number is
based. Whenever any building is situated so that the number is not clearly discernible from the street line or
vision of the building from the street is otherwise obscured, the number or numbers assigned shall be placed
near the walk, driveway or common entrance to such buildings, and affixed upon a gate post, fence, mailbox,
post, or other appropriate place so as to be easily discernible (this is in addition to the numbers/letters on the
building). Numbers painted or stenciled on the curb shall not be a lawful substitute for the display of address
numbers prescribed by this article. Subject to change upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Fire Hydrant
The Little Rock Fire Department, Capt. Tony Rhodes (501) 918-3757, needs to evaluate this site to determine
whether additional public and/or private fire hydrants will be required. The installation of any new fire
protection facilities will be at the expense of the project developer. Contact Central Arkansas Water regarding
procedures for installation of the hydrant(s). Subject to change at any time upon field evaluation.
5
CAPTAIN TONY RHODES
FIRE MARSHALS DIVISION
LITTLE ROCK FIRE DEPARTMENT
624 S. CHESTER. ST.
LITTLE ROOK, AR 72201
OFFICE: C501) 918-3757
CELL., (501) 607-3560
FAX: (501) 918-3779
City of Little Rock
Planning and Development
Filing Fees
Date- 4 / 1 , 20&
Annexation
Board of Adjustment
Cond Use Permit/T UP
Final Plat
Planned Unit Dev
Preliminai y Plat
Special Use Permit
Rezoning
Site Plans
Sheet Name Change
Street Name Signs
Number at ea
Public Hearing Signs
Numberat � -ea
Total
File No
Location
AppliC
By C�n�
i