HomeMy WebLinkAboutZ-6178-C Staff AnalysisAugust 3, 2000
ITEM NO.: 1.1 FILE NO.: Z -6178-C
NAME: Stagecoach Village (Lot 4) - Short -Form PCD
LOCATION: West side of Stagecoach Road, approximately 1,600
feet south of Baseline Road
nRVFLOPER:
Stagecoach Village, LLC
9222 Stagecoach Road
Little Rock, AR 72209
AREA: 1.7 acres
ZONING: R-2
V_Wr_TWPR.R-
McGetrick & McGetrick
319 E. Markham St., Ste. 202
Little Rock, AR 72201
NUMBER OF LOTS: 1
ALLOWED USES:
PROPOSED USE:
VARIANCES/WAIVERS REQUESTED:
A. PROPOSAL/REQUEST:
FT. NEW STREET: 0
Single Family Residential
Office/Commercial Mix,
C-2 Permitted Uses
None requested.
The applicant proposes to rezone the proposed Lot 4,
Stagecoach Village Subdivision from R-2 to PCD. The
applicant proposes to construct a 3,600 square foot branch
bank building with drive-thru lanes (Building A), a 9,000
square foot commercial building (Building B) and associated
parking areas.
The applicant proposes to utilize Building A as a branch
bank and if a bank tenant cannot be secured for the
building, the applicant will remove the drive lanes from
the site plan and utilize the building for C-2 uses.
Building B will be 80 percent commercial (C-2 uses) and 20
percent office use. The applicant notes that there will be
no exterior speakers on the site.
August 3, 2000
SUBDIVISION
ITEM NO.: 1.1 (Cont.) FILE NO.: Z -6178-C
The proposed hours of operation are as follows:
8:00 a.m. - 10:00 p.m., Monday -Saturday
10:00 a.m. - 6:00 p.m., Sunday
The applicant is proposing a ground -mounted sign near the
northeast corner of the property. The sign will have a
maximum height of 8 feet and a maximum area of 80 square
feet.
The applicant is proposing to access the property by
utilizing two (2) drives from Staley Drive. The
easternmost drive is proposed to be right in/right out
only.
B. EXISTING CONDITIONS:
The area of Lot 4 has been mostly cleared. There are some
trees along the property's south boundary.
The property to the south, along Stagecoach Road, is vacant
and wooded, and contains a large Entergy power line. Tract
A (zoned R-2) of this development is located immediately
west, with Lots 1-3 located across the proposed Staley
Drive to the north. There are three single family
residences to the east across Stagecoach Road.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received one (1) phone call
from a neighbor with concerns. The Otter Creek, Crystal
Valley and SWLR UP Neighborhood Associations were notified
of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Proposed design of streets conforming to "MSP". (Curve
radii and tangent violates "MSP").
2. Sidewalks shall be shown conforming to Sec. 31-175 and
the "MSP" (buffered) .
3. Driveways shall conform to Sec. 31-210 or Ordinance
18,031. (Lot 1 drive from rear access). Eliminate
driveways shown first from Stagecoach must be 250 feet
back.
4. Stormwater Detention per Ordinance 14,787 and the
"Drainage Manual" is required.
0�
August 3, 2000
SUBDIVISION
ITEM NO.: 1.1 (Cont.)
FILE NO.: Z -6178-C
5. Prepare a letter for streetlights as required by
Sec. 31-403.
6. Plans of all work in right-of-way shall be submitted for
approval prior to start of work.
7. Contact the AHTD for work within the State Highway
right-of-way.
8. Construct Staley Drive to MSP standards.
9. Only one (1) driveway will be permitted.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required with easements
to serve property.
AP&L: No Comment.
Arkla: No Comment received.
Southwestern Bell: No Comment.
Water: A development fee applies, based on the'size of
connection, in addition to normal charges for water
service. A water main extension or on site fire
protection may be required.
Fire Department: Check with Water Works regarding the
nearest fire hydrant.
County Plannin : No Comment received.
CATA: Site is not on a dedicated bus route; however, the
proposed development should be designed to allow
bus/transit access.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division:
This request is located in the Otter Creek Planning
District. The Future Land Use Plan shows Mixed Use for
this location. The request is for a zone change from R-2
Single Family to a Planned Commercial District. The
applicant wishes to develop the property for a mix of
commercial and office uses. This change does not require a
land use plan amendment.
City Reco nized Neighborhood Action Plan:
This request is located in an area covered by the Otter
Creek/Crystal Valley Neighborhood Action Plan. The OC/CV
Neighborhood Action Plan contains an action statement
3
August 3, 2000
SUBDIVISION
ITEM NO.: 1.1 (Cont.)
FILE NO.: Z -6178-C
calling for the aggressive use of Planned Zoning Districts
to influence more neighborhood -friendly and better quality
development under the Office and Commercial Development
Goal. The plan contains an action statement of limiting
commercial and office development to a corridor along
Stagecoach Road between Baseline Road and Otter Creek Road.
The plan also contains another action statement of
requiring businesses to be accessed by loop streets to
minimize curb cuts and allow for attractive landscaping.
Landscape Issues:
Areas set aside for buffers and landscaping meet with
ordinance requirements.
A six foot high opaque screen, either a wooden fence with
its face side directed outward or dense evergreen
plantings, is required along the southern and western
perimeters. The screen along the southern perimeter may be
deemed nonfunctional because of the adjacent wide power
line easement.
G_ SUBDIVISION COMMITTEE COMMENT:
(JULY 13, 2000)
Pat McGetrick and Olan Asbury were present, representing
the application. Staff briefly described the PCD.
Mr. McGetrick noted that he had no issues with the staff
comments. The Public Works requirements were briefly
discussed. The driveway locations for this development
were discussed. The driveway nearest to Stagecoach Road
being right-in/right-out only to eliminate a possible
traffic congestion problem was discussed.
After the brief discussion, the Committee forwarded the PCD
to the full Commission for resolution.
H. ANALYSIS:
The applicant submitted a revised site plan to staff on
July 19, 2000. The revised plan addresses the concerns as
raised by staff and the Subdivision Committee.
The proposed site plan shows a total of 54 parking spaces.
The City's Zoning Ordinance would typically require a
�1
August 3, 2000
SUBDIVISION
ITEM NO.: 1.1 (Cont.) FILE NO.: Z -6178-C
minimum of 45 spaces for a development of this size. Staff
supports the parking plan as proposed.
To staff's knowledge, the only outstanding issue relates to
the proposed easternmost access drive. Public Works does
not support this driveway location, as the drive is located
too close to Stagecoach Road and could cause traffic
congestion problems. The drive is located approximately
120 feet from the centerline of Stagecoach Road.
Otherwise, there should be no outstanding issues associated
with the PCD. With compliance to the conditions noted in
the next paragraph, the proposed development should have no
adverse effect on the general area.
I. STAFF RECOMMENDATIONS:
Staff recommends approval of the PCD zoning subject to the
following conditions:
1. Compliance with the requirements as noted in paragraphs
D, E and F of this report.
2. The proposed ground -mounted sign will have a maximum
height of 8 feet and a maximum area of 80 square feet.
Staff recommends that the sign be monument -type.
3. Any site lighting should be low-level and directed away
from adjacent property.
4. The dumpster location must be screened on 3 sides with a
8 foot opaque fence or wall.
5. The driveway location issue must be resolved. Public
Works does not support the easternmost drive location.
6. Staff suggests that the following conditions be placed on
this PCD as they were conditions of approval for Lot 2:
a. No external pay phones, ice machines, vending
machines or speakers.
b. No signage other than the ground -mounted sign
proposed and permanent wall signs.
PLANNING COMMISSION ACTION: (AUGUST 3, 2000)
Pat McGetrick was present, representing the application. Staff
briefly described the PCD site plan, with a recommendation of
approval with conditions.
See the preliminary plat file (S -1273-A) minute record for
further discussion.
5
August 3, 2000
SUBDIVISION
ITEM NO.: 1.1 (Cont.) FILE NO,.: Z -6178-C
There was a motion to approve the PCD application as recommended
by staff. The motion passed with a vote of 9 ayes, 0 nays and
2 absent.
C
FILE NO.: Z -6178-C
NAME: Stagecoach Village (Lot 4) - Short -Form PCD
LOCATION: West side of Stagecoach Road, approximately 1,600
feet south of Baseline Road
n !VV..T.nPER:
Stagecoach Village, LLC
9222 Stagecoach Road
Little Rock, AR 72209
AREA: 1.7 acres
ZONING: R-2
ENGINEER:
McGetrick & McGetrick
319 E. Markham St., Ste. 202
Little Rock, AR 72201
NUMBER OF LOTS: 1
FT. NEW STREET: 0
ALLOWED USES: Single Family Residential
PROPOSED USE:
VARIANCES/WAIVERS REQUESTED:
A. PROPOSAL/REQUEST:
Office/Commercial Mix,
C-2 Permitted Uses
None requested.
The applicant proposes to rezone the proposed Lot 4,
Stagecoach Village Subdivision from R-2 to PCD. The
applicant proposes to construct a 3,600 square foot branch
bank building with drive-thru lanes (Building A), a 9,000
square foot commercial building (Building B) and associated
parking areas.
The applicant proposes to utilize Building A as a branch
bank and if a bank tenant cannot be secured for the
building, the applicant will remove the drive lanes from
the site plan and utilize the building for C-2 uses.
Building B will be 80 percent commercial (C-2 uses) and 20
percent office use. The applicant notes that there will be
no exterior speakers on the site.
The proposed hours of operation are as follows:
FILE NO.: Z -6178-C (Cont.)
8:00 a.m. - 10:00 p.m., Monday -Saturday
10:00 a.m. - 6:00 p.m., Sunday
The applicant is proposing a ground -mounted sign near the
kortheast corner of the property. The sign will have a
maximum height of 8 feet and a maximum area of 80 square
feet.
The applicant is proposing to access the property by
utilizing two (2) drives from Staley Drive. The
easternmost drive is proposed to be right in/right out
only.
B. EXISTING CONDITIONS:
C
The area of Lot 4 has been mostly cleared. There are some
trees along the property's south boundary.
The property to the south, along Stagecoach Road, is vacant
and wooded, and contains a large Entergy power line. Tract
A (zoned R-2) of this development is located immediately
west, with Lots 1-3 located across the proposed Staley
Drive to the north. There are three single family
residences to the east across Stagecoach Road.
NEIGHBORHOOD COMMENTS:
As of this writing, staff has received one (1) phone call
from a neighbor with concerns. The Otter Creek, Crystal
Valley and SWLR UP Neighborhood Associations were notified
of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Proposed design of streets conforming to "MSP". (Curve
radii and tangent violates "MSP").
2. Sidewalks shall be shown conforming to Sec. 31-175 and
the "MSP" (buffered) .
3. Driveways shall conform to Sec. 31-210 or Ordinance
18,031. (Lot 1 drive from rear access). Eliminate
driveways shown first from Stagecoach must be 250 feet
back.
4.Stormwater Detention per Ordinance 14,787 and the
"Drainage Manual" is required.
5. Prepare a letter for streetlights as required by
Sec. 31-403.
6.Plans of all work in right-of-way shall be submitted for
approval prior to start of work.
PA
FILE NO.: Z -6178-C (Cont.
7. Contact the AHTD for work within the State Highway right -
of -way.
8. Construct Staley Drive to MSP standards.
9. Only one (1) driveway will be permitted.
E. 1TILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required with easements
to serve property.
AP&L: No Comment.
Arkla: No Comment received.
Southwestern Bell: No Comment.
Water: A development fee applies, based on the size of
connection, in addition to normal charges for water
service. A water main extension or on site fire
protection may be required.
Fire Department: Check with Water Works regarding the
nearest fire hydrant.
County Planning: No Comment received.
CATA: Site is not on a dedicated bus route; however, the
proposed development should be designed to allow
bus/transit access.
F. ISSUES/TECHNICAL/DESIGN:
Plannina Division:
This request is located in the Otter Creek Planning
District. The Future Land Use Plan shows Mixed Use for
this location. The request is for a zone change from R-2
Single Family to a Planned Commercial District. The
applicant wishes to develop the property for a mix of
commercial and office uses. Thi$ change does not require a
land use plan amendment.
City Recognized Neighborhood Action Plan:
This request is located in an area covered by the Otter
Creek/Crystal Valley Neighborhood Action Plan. The OC/CV
Neighborhood Action Plan contains an action statement
calling for the aggressive use of Planned Zoning Districts
to influence more neighborhood -friendly and better quality
development under the Office and Commercial Development
Goal. The plan contains an action statement of limiting
commercial and office development to a corridor along
Stagecoach Road between Baseline Road and Otter Creek Road.
The plan also contains another action statement of
3
FILE NO.: Z -6178-C (Cont.)
requiring businesses to be accessed by loop streets to
minimize curb cuts and allow for attractive landscaping.
Landscape Issues:
Areas set aside for buffers and landscaping meet with
ordinance requirements.
A six foot high opaque screen, either a wooden fence with
its face side directed outward or dense evergreen
plantings, is required along the southern and western
perimeters. The screen along the southern perimeter may be
deemed nonfunctional because of the adjacent wide power
line easement.
G. SUBDIVISION COMMITTEE COMMENT: (JULY 13, 2000)
Pat McGetrick and Olan Asbury were present, representing
the application. Staff briefly described the PCD.
1.
Mr. McGetrick noted that he had no issues with the staff
comments. The Public Works requirements were briefly
discussed. The driveway locations for this development
were discussed. The driveway nearest to Stagecoach Road
being right-in/right-out only to eliminate a possible
traffic congestion problem was discussed.
After the brief discussion, the Committee forwarded the PCD
to the full Commission for resolution.
H. ANALYSIS:
The applicant submitted a revised site plan to staff on
July 19, 2000., The revised plan addresses the concerns as
raised by staff and the Subdivision Committee.
The proposed site plan shows a total of 54 parking spaces.
The City's Zoning Ordinance would typically require a
minimum of 45 spaces for a development of this size. Staff
supports the parking plan as proposed.
To staff's knowledge, the only outstanding issue relates to
the proposed easternmost access drive. Public Works does
not support this driveway location, as the drive is located
too close to Stagecoach Road and could cause traffic
congestion problems. The drive is located approximately
120 feet from the centerline of Stagecoach Road.
4
FILE NO.: Z -6178-C (Cont.)
Otherwise, there should be no outstanding issues associated
with the PCD. With compliance to the conditions noted in
the next paragraph, the proposed development should have no
adverse effect on the general area.
I. kAFF RECOMNENDATIONS:
Staff recommends approval of the PCD zoning subject to the
following conditions:
1. Compliance with the requirements as noted in paragraphs
D, E and F of this report.
2. The proposed ground -mounted sign.will have a maximum
height of 8 feet and a maximum area of 80 square feet.
Staff recommends that the sign be monument -type.
3. Any site lighting should be low-level and directed away
from adjacent property.
4. The dumpster location must be screened on 3 sides with a
8 foot opaque fence or wall.
5. The driveway location issue must be resolved. Public
Works does not support the easternmost drive location.
6. Staff suggests that the following conditions be placed on
this PCD as they were conditions of approval for Lot 2:
a. No external pay phones, ice machines, vending
machines or speakers.
b. No signage other tha)z the ground -mounted sign
proposed and permanent wall signs.
PLANNING COMMISSION ACTION: (AUGUST 3, 2000)
Pat McGetrick was present, representing the application. Staff
briefly described the PCD site plan, with a recommendation of
approval with conditions.
See the preliminary plat file (S -1273-A) minute record for
further discussion.
There was a motion to approve the PCD application as recommended
by staff. The motion passed with a vote of 9 ayes, 0 nays and
2 absent.
5