HomeMy WebLinkAboutZ-6135-E MapSITE SUMMARY
PROJECT SCOPE: PROJECT CONSISTS OF INSTALLING
PROPOSED DISH WIRELESS
TELECOMMUNICATION EQUIPMENT,
CABLING, AND ANTENNAS AT AN
EXISTING TELECOMMUNICATION SITE
SITE TYPE: CO -LOCATION
TYPE OF OCCUPANCY:
TELECOMMUNICATIONS
TOWER TYPE:
SELF-SUPPORT
RAD CENTER:
247.0'
TOWER LATITUDE:
34° 46' 2C.3e" N (34,7723)
TOWER LONGITUDE:
92° 2 i' 27.96" W (-92.3578)
ZONING JURISDICTION:
CITY OF LOTLE ROCK
COUNTY:
PULASKI
PARCEL NUMBER:
43LO480001200
POWER COMPANY:
ENTERGY
1
(800) 368-3749
TELEPHONE COMPANY:
AT&T
1
(800) 331-0500
PROJECT DIRECTORY
TOWER OWNER: SBA COMMUNICATIONS
8051 CONGRESS AVE
BOCA RATION, FL 33487
CONTACT: SHAWN WELTER
PHONE: (228) 596-6478
APPLICANT: DISH WIRELESS
9601 S MERIDIAN BLVD
ENGLEWOOD. CO 80112
CONTACT: SUJEEVA RANASINGHE
PHONE: (303) 706-4088
SITE DESIGNER: TOWER ENGINEERING PROFESSIONALS
326 TRYON ROAD
RALEIGH, NC 27603-3530
CONTACT: GRAHAM M. ANDRES, P.E.
(919) 661-6351
GENERAL NOTES I
THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION,
THEREFORE HANDICAP ACCESS IS NOT REQUIRED. A TECHNICIAN WILL
VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE. THE
PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR
EFFECT ON DRAINAGE; NO SANITARY SEWER SERVICE, POTABLE
WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL
SIGNAGE IS PROPOSED.
UNDERGROUND
SERVICE ALERT
k5
CALL 811
48 HOURS BEFORE YOU DIG
DISH WIRELESS FIRST TIME INSTALL
CONSTRUCTION DRAWINGS
is
WIRELESS
DISH WIRELESS SITE ID:
TOWER OWNER SITE ID:
AR09991-A
SITE ADDRESS:
227-D KEIGHTLY DRIVE
LITTLE ROCK, AR 72207
(PULASKI COUNTY)
*I Approved
VICINITY MAP N..
DISH WIRELESS PROJECT MANAGER APPROVAL:
SIGNATURE DATE
C❑NSTRUCTI❑N MANAGER APPROVAL:
SIGNATURE DATE
moi_ IJ T t" ° ' t•:.- 4
SIGNATURE DATE
__ , _ 7 Iy
`- 5'i l�= I'(•i1 i..
�A/
r.-• _ .-..'.Ji?
2
01-09-19
LANDLORD/TOWER OWNER APPROVAL:
GENERAL NOTES
VICINITY MAP N..
DISH WIRELESS PROJECT MANAGER APPROVAL:
SIGNATURE DATE
C❑NSTRUCTI❑N MANAGER APPROVAL:
SIGNATURE DATE
LEASING/SITE ACQUISITIGN:
SIGNATURE DATE
RF ENGINEER:
T-1
SIGNATURE DATE
2
01-09-19
LANDLORD/TOWER OWNER APPROVAL:
GENERAL NOTES
SIGNATURE DATE
VICINITY MAP N..
L❑CAL MAP M
DESCRIPTION
REV ISSUED BY
w
DESCRIPTI❑N
REV.
NO.
REVISI❑N
DATE
T-1
TITLE SHEET
2
01-09-19
GN -1
GENERAL NOTES
wj
01-719
CODE COMPLIANCE
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE
FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO
PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING:
• 2012 INTERNATIONAL BUILDING CODE ANSIMA-222-G
2012 INTERNATIONAL FIRE CODE LOCAL BUILDING CODE
• 2006 INTERNATIONAL FUEL GAS CODE CITY/COUNTY ORDINANCES
2009 INTERNATIONAL MECHANICAL CODE FAA COMPLIANCE
2009 INTERNATIONAL ENERGY CONSERVATION CODE FCC COMPLIANCE
• 2017 NATIONAL ELECTRICAL CODE
PREPARED FOR:
d.:-
sh
WIRELESS
PREPARED BY:
TOWER ENGINEERIV00FESSIONALS
326 TRY 0A0
SEAL:
�f RFGISTr=RED
PRUFESSIONALENGANEER
No 1
I
January 9, 2019
DRAWN BY: WKT
CHECKED BY: MJC
APPV'D: CSN
SUBMITTALS
SHEET INDEX
DESCRIPTION
REV ISSUED BY
SHEET
NO.
DESCRIPTI❑N
REV.
NO.
REVISI❑N
DATE
T-1
TITLE SHEET
2
01-09-19
GN -1
GENERAL NOTES
1
01-719
GN -2
GENERAL NOTES
1
01-04-19
EN -1
ELECTRICAL NOTES
1
01-04-19
EN -2
ELECTRICAL NOTES
1
01-04-19
C-1
COMPOUND PLAN
2
01-09-19
C-2
EQUIPMENT PLAN
1
01-04-19
C-3
TOWER ELEVATION & ANTENNA LAYOUT
2
01-09-19
1 OF 2
ANTENNA SCHEDULE & DIAGRAM (SUPP.)
2
01-09-19
2 OF 2
CABLE COLOR CODE (SUPPLEMENTAL)
1
01-04-19
C-4
EQUIPMENT DETAILS
1
01-04-19
C-5
EQUIPMENT DETAILS
1
01-04-19
C-6
CIVIL DETAILS
1
01-04-19
C-7
CIVIL DETAILS
1
01-04-19
C-8
PLATFORM CANOPY DETAILS
1
01-04-19
E-1
UTILITY PLANS
1
01-04-19
E-2
ELECTRICAL DETAILS
1
01-04-19
G-1
GROUNDING NOTES & DETAILS
2
01-09-19
G-2
GROUNDING NOTES & DETAILS
1
01-04-19
G-3
GROUNDING NOTES & DETAILS
1
01-04-19
RF -1
RF DATA SHEET (SUPPLEMENTAL)
2
01-09-19
RF -2
PLUMBING DIAGRAM (SUPPLEMENTAL)
1
01-04-19
PREPARED FOR:
d.:-
sh
WIRELESS
PREPARED BY:
TOWER ENGINEERIV00FESSIONALS
326 TRY 0A0
SEAL:
�f RFGISTr=RED
PRUFESSIONALENGANEER
No 1
I
January 9, 2019
DRAWN BY: WKT
CHECKED BY: MJC
APPV'D: CSN
SUBMITTALS
DATE I
DESCRIPTION
REV ISSUED BY
12-20-18
PRELIMINARY
0 CP
01-04-19
CONSTRUCTION
1 CP
01-09-19
CONSTRUCTION
2 CP
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS 15 PROPRIETARY BY NATURE.
REPRODUCTION OR CAUSING TO BE REPRODUCED
THE WHOLE OR ANY PART OF THESE DRAWINGS
WITHOUT THE PERMISSION OF
TOWER ENGINEERING PROFESSIONALS
15 PROHIBITED.
TEP NUMBER:
145629
DISH WIRELESS SITE ID:
AR0900004B
TOWER OWNER SITE ID:
AR09991-A
SITE ADDRESS:
227-D KEIGHTLY DRIVE
LITTLE ROCK, AR 72207
(PULASKI COUNTY)
SHEET TITLE:
TITLE SHEET
SHEET NUMBER:
T-'1
EXISTING 10'-0"
)--WIDE ACCESS GATE
EXISTING HVAC BY
OTHERS (TYP)
PROPOSED 5'-0"X7'-0" DISH
WIRELESS LEASE AREA
PROPOSED 5'-0"X7'-0" DISH WIRELESS
EQUIPMENT PLATFORM BY COMMSCOPE
(P/N: MTC4045LP) W/ ICE CANOPY (P/N:
MTC4045GC). SEE SHEET C-2 FOR DETAILS
x x
PROPOSED 8'-0"z8'-0" DISH WIRELESS
AREA OF GROUND DISTURBANCE FOR
BELOW GRADE GROUNDING SYSTEM
PROPOSED 5" WIDE ICE BRIDGE.
SEE SHEET C-7 FOR DETAILS.
PROPOSED DISH WIRELESS CABLE LADDER.
SEE SHEET C-4 FOR DETAILS.
x
EXISTING -
4' -4" [�� 9
-�� WIDE ACCESS GATE
EXISTING UTILITY RACK s.
BY OTHERS (TYP)
v
X X X X X
EXISTING METER MOUNTED ON METER TO BE INSTALLED IN
UTILITY POLE BY OTHERS (TYP) EXISTING EMPTY METER SLOT
EXISTING VAULT
EXISTING TELCO PEDESTAL
(TYP)
x x X X X
0
45'-0"
�i _ _ r EXISTING CABLE
I TRAY BY OTHERS
I
EXISTING EQUIPMENT
PAD BY OTHERS
I
----- EXISTING EQUIPMENT
PLATFORM BY OTHERS
o
o _
COMPOUND PLAN
SCALE: 3/32"
HYBRID CABLE LENGTH: 0 8 16
PROPOSED DISH WIRELESS HYBRID CABLE
LENGTH: 275'-0"t (CONTRACTOR TO VERIFY) SCALE IN FEET
EXISTING ICE BRIDGE
BY OTHERS (TYP)—
EXISTING
TYP)—
EXISTING SELF-SUPPORT
TOWER. SEE SHEET C-3
FOR ELEVATION.
EXISTING GENERATOR
PAD BY OTHERS
EXISTING GRAVEL
WITHIN COMPOUN
EXISTING WOODEN
FENCE SECTION
x
NOTES:
1. ALL SITE INFORMATION HAS BEEN
PROVIDED BY THE CLIENT. TEP IS NOT
LIABLE AND DOES NOT ASSUME
RESPONSIBILITY FOR THIS CONTENT.
2. PROPOSED SATELLITE DISH LOCATION TO
BE VERIFIED IN THE FIELD AT TIME OF
CONSTRUCTION.
PREPARED FOR:
WIRELESS_
PREPARED BY:
i'
A�
1%
4%1
401
TOWER ENGINEERING, P ON
326TR1 0AD
RAlRWl NC 603526
SEAL
�t'•I��
..SAS
PRO )NAL
f
Ali N0 15 rl 5 4
rf
January 4, 2019
DRAWN BY: WKT
CHECKED BY: MJC
APPV'D: CSN
SUBMITTALS
DATE I DESCRIPTION REV ISSUED BY
12-20-18 1 PRELIMINARY 0 1 CP
01-04-19 CONSTRUCTION 1 CP
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE.
REPRIOUCYrON OR CAUSING TO BE REPRODUCED
THE WHOLE OR ANY PART OF THESE DRAWINGS
WITHOUT THE PERMISSION OF
TOWER ENGINEERING PROFESSIONALS
IS PROHIBITED.
TEP NUMBER:
145629
DISH WIRELESS SITE ID:
AR0900004B
TOWER OWNER SITE ID:
AR09991-A
SITE ADDRESS:
227-D KEIGHTLY DRIVE
LITTLE ROCK, AR 72207
(PULASKI COUNTY)
SHEET TITLE:
COMPOUND PLAN
SHEET NUMBER
CA
EXISTING CHAIN-LINK
FENCED COMPOUND—..
�x
x
EXISTING 11'-8"
WIDE ACCESS GATE
EXISTING EQUIPMENT SHELTER
BY OTHERS (TYP)
EXISTING EMPTY PAD
x
BY OTHERS (TYP)
EXISTING 10'-0"
)--WIDE ACCESS GATE
EXISTING HVAC BY
OTHERS (TYP)
PROPOSED 5'-0"X7'-0" DISH
WIRELESS LEASE AREA
PROPOSED 5'-0"X7'-0" DISH WIRELESS
EQUIPMENT PLATFORM BY COMMSCOPE
(P/N: MTC4045LP) W/ ICE CANOPY (P/N:
MTC4045GC). SEE SHEET C-2 FOR DETAILS
x x
PROPOSED 8'-0"z8'-0" DISH WIRELESS
AREA OF GROUND DISTURBANCE FOR
BELOW GRADE GROUNDING SYSTEM
PROPOSED 5" WIDE ICE BRIDGE.
SEE SHEET C-7 FOR DETAILS.
PROPOSED DISH WIRELESS CABLE LADDER.
SEE SHEET C-4 FOR DETAILS.
x
EXISTING -
4' -4" [�� 9
-�� WIDE ACCESS GATE
EXISTING UTILITY RACK s.
BY OTHERS (TYP)
v
X X X X X
EXISTING METER MOUNTED ON METER TO BE INSTALLED IN
UTILITY POLE BY OTHERS (TYP) EXISTING EMPTY METER SLOT
EXISTING VAULT
EXISTING TELCO PEDESTAL
(TYP)
x x X X X
0
45'-0"
�i _ _ r EXISTING CABLE
I TRAY BY OTHERS
I
EXISTING EQUIPMENT
PAD BY OTHERS
I
----- EXISTING EQUIPMENT
PLATFORM BY OTHERS
o
o _
COMPOUND PLAN
SCALE: 3/32"
HYBRID CABLE LENGTH: 0 8 16
PROPOSED DISH WIRELESS HYBRID CABLE
LENGTH: 275'-0"t (CONTRACTOR TO VERIFY) SCALE IN FEET
EXISTING ICE BRIDGE
BY OTHERS (TYP)—
EXISTING
TYP)—
EXISTING SELF-SUPPORT
TOWER. SEE SHEET C-3
FOR ELEVATION.
EXISTING GENERATOR
PAD BY OTHERS
EXISTING GRAVEL
WITHIN COMPOUN
EXISTING WOODEN
FENCE SECTION
x
NOTES:
1. ALL SITE INFORMATION HAS BEEN
PROVIDED BY THE CLIENT. TEP IS NOT
LIABLE AND DOES NOT ASSUME
RESPONSIBILITY FOR THIS CONTENT.
2. PROPOSED SATELLITE DISH LOCATION TO
BE VERIFIED IN THE FIELD AT TIME OF
CONSTRUCTION.
PREPARED FOR:
WIRELESS_
PREPARED BY:
i'
A�
1%
4%1
401
TOWER ENGINEERING, P ON
326TR1 0AD
RAlRWl NC 603526
SEAL
�t'•I��
..SAS
PRO )NAL
f
Ali N0 15 rl 5 4
rf
January 4, 2019
DRAWN BY: WKT
CHECKED BY: MJC
APPV'D: CSN
SUBMITTALS
DATE I DESCRIPTION REV ISSUED BY
12-20-18 1 PRELIMINARY 0 1 CP
01-04-19 CONSTRUCTION 1 CP
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE.
REPRIOUCYrON OR CAUSING TO BE REPRODUCED
THE WHOLE OR ANY PART OF THESE DRAWINGS
WITHOUT THE PERMISSION OF
TOWER ENGINEERING PROFESSIONALS
IS PROHIBITED.
TEP NUMBER:
145629
DISH WIRELESS SITE ID:
AR0900004B
TOWER OWNER SITE ID:
AR09991-A
SITE ADDRESS:
227-D KEIGHTLY DRIVE
LITTLE ROCK, AR 72207
(PULASKI COUNTY)
SHEET TITLE:
COMPOUND PLAN
SHEET NUMBER
CA
SAFETY NOTE
WHEN APPLICABLE, CONTRACTOR
SHALL COVER PROPOSED (8"xB")
HOLE IN PLATFORM GRATE TO
PREVENT TRIPPING HAZARD. SEE
OSHA STANDARDS, SECTION 29
CFR 1926.501(b)(4)(ii).
PROPOSED DISH WIRELESS ICE CANOPY
(COMMSCOPE, P/N: MTC4045GC OR
APPROVED EQUIVALENT). SEE SHEET
C -B FOR DETAILS.
PROPOSED 5'-0"x7'-0" DISH
WIRELESS EQUIPMENT PLATFORM W/
(4) EQUIPMENT PLATFORM FEET.
SEE SHEET C-6 FOR DETAILS.
PROPOSED 5'-0"x7'-0" DISH
WIRELESS LEASE AREA
PROPOSED STACKED ERICSSON
EQUIPMENT CABINET
NOTES:
1,
PROPOSED SATELLITE DISH
OR LTE BACKHAUL LOCATION
TO BE VERIFIED, WITH DISH
CM, IN THE FIELD AT TIME
OF CONSTRUCTION,
2.
WHEN APPLICABLE, DISH
WIRELESS SUPPORT PIPE
SHALL BE POSITIONED AS
TO AFFORD FUTURE DISH A
CLEAR, UNOBSTRUCTED VIEW
OF THE SOUTHERN SKY,
3-
CONTRACTOR TO PROVIDE
4MIL BLACK PLASTIC
BENEATH PROPOSED DISH
WIRELESS EQUIPMENT
PLATFORM AND LEGS.
4.
PROPOSED MTC4045CC
PLATFORM CANOPY NOT
SHOWN FOR CLARITY. SEE
SHEET C-8 FOR DETAILS.
5.
WHEN APPLICABLE,
CONTRACTOR TO CUT 8"X8"
HOLE AND TREAT BARE
METAL WITH ZRC ZINC COLD
GALVANIZING SPRAY PAINT
(THREE COATS, ALLOW TO
DRY BETWEEN COATS).
CONTRACTOR TO ADJUST
DISH LOCATION TO ALLOW
ENTIRE DISH AND FEED
HORN TO NOT EXTEND
OUTSIDE PLATFORM
PERIMETER AND PROVIDE
CLEAR VIEW OF SATELLITE
Z
C7
z
w
J
w
0
IY
CID
I—
w
w
cn2
w
N
PROPOSED 8'-0"x8'-0" DISH
WIRELESS AREA OF GROUND
DISTURBANCE FOR BELOW GRADE
GROUNDING SYSTEM
PROPOSED 2J�" TYPE LB CONDUIT
BODY FROM PROPOSED HOFFMAN
BOX TO PROPOSED BASEBAND UNIT
r -------1f7
---------------------
PROPOSED 24"x24"x6" HOFFMAN
BOX (P/N: A24R248) MOUNTED TO
I
I
I
I
1
r�
4"
PROPOSED CABINET SUPPORT
STRUCTURE
F
I
I
I
I
I
--------------------------------
PROPOSED 5" WIDE DISH
WIRELESS ICE BRIDGE. SEE SHEET
C-7 FOR DETAILS.
PROPOSED HYBRID CABLE ROUTED
UP TOWER TO PROPOSED DISH
WIRELESS RAD CENTER
EQUIPMENT PLAN
SCALE: Y2" = 1'-0
0 2 4
SCALE IN FEET
PROPOSED 8"x8" HOLE TO BE
CUTIN PROPOSED PLATFORM
GRATE FOR SATELLITE DISH,
INSTALLED BY DISH WIRELESS.
SEE NOTE 5, THIS SHEET.
PROPOSED DISH WIRELESS UTILITY
RACK MOUNTED TO PLATFORM
CONTRACTOR TO PROVIDE
WEATHERPROOF GFCI AND MOUNT
IT TO PROPOSED UTILITY RACK
TURE TELCO BOX
PROPOSED 100A SERVICE ENTRANCE
RATED DISCONNECT MOUNTED TO
PROPOSED UTILITY RACK
PROPOSED 100A ELECTRICAL
LOAD CENTER MOUNTED TO
PROPOSED UTILITY RACK
PROPOSED GPS ANTENNA,
INSTALLED BY DISH WIRELESS
PREPARED FOR:
!.714
WIRELE S S
PREPARED BY:
�I
A�1
®1
v
�
TOWER EHGIH�NAU
SEAL:
Arr' q�
0
= .ANSA$ ,
--j
Ecr G35" CPEO
PRUPESSiONAL
ENGINEER
1�''n Nj0 4 X554
,7anuary 4, 2019
DRAWN BY: WKT
CHECKED BY: MJC
APPV'D: CSN
SUBMITTALS
DATE DESCRIPTION REV ISSUED BY
12-20-18 PRELIMINARY 0 CP
01-04-19 CONSTRUCTION 1 CP
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE.
REPRODUCTION OR CAUSING TO BE REPRODUCED
THE WHOLE OR ANY PART OF THESE DRAWINGS
WITHOUT THE PERMISSION OF
TOWER ENGINEERING PROFESSIONALS
IS PROHIBITED.
TEP NUMBER:
145629
DISH WIRELESS SITE ID:
AR0900004B
TOWER OWNER SITE ID:
AR09991-A
SITE ADDRESS:
227-D KEIGHTLY DRIVE
LITTLE ROCK, AR 72207
(PULASKI COUNTY)
SHEET TITLE:
EQUIPMENT PLAN
SHEET NUMBER:
C-2
NOTE
1. VERTICAL DISTANCE BETWEEN PROPOSED AND EXISTING ANTENNAS BASED ON INFORMATION
PROVIDED IN STRUCTURAL ANALYSIS. DISH WIRELESS TO CONFIRM WITH TOWER OWNER THE
VERTICAL LEASE AREA RIGHTS AVAILABLE PRIOR TO CONSTRUCTION, EXISTING EQUIPMENT
MAY OBSTRUCT DESIRED DISH WIRELESS RAD—CENTER.
2. TOWER FACE WIDTH/DIAMETER IS AN ESTIMATE FROM STRUCTURAL ANALYSIS.
III 3. ADD MID GROUND BUS BAR WHERE APPLICABLE PER LIGHTNING ZONE REQUIREMENTS. iJ
RAD CENTER
FACE WIDTH OR DIAMETER
HYBRID CABLE LENGTH
247'-0"t
3'-0"t
275'-0"t
2
PROPOSED ERICSSON RRU E2
B29 (TYP OF 3). SEE SHEET
C-4 FOR DETAILS.
PROPOSED LESSEE ANTENNA
(COMBA, P/N:
ODI-065R16M18JJ-GO V2 OR
APPROVED EQUIVALENT, TYP OF
'o
3). SEE SHEET C-4 FOR DETAILS. �Z
7�
PROPOSED LESSEE �" PROPOSED RET CABLE
PROPOSED DISH WIRELESS WAVEGUIDE. SEE SHEET ++ I
ANTENNA ARRAY, SEE C-4 FOR DETAILS, t+ (TYP OF 3), SEE SUPP, INFO.,
250'-0"f PROPOSED ANTENNA II SHEET 1 OF 2, FOR DETAILS.
it
T/TOWER LAYOUT, THIS SHEET, FOR I ROPOSED ERICSSON RADIO 4415
�r DETAILS,
h 247'-0"tf EXISTING OMNI ANTENNA BY MOUNTED BENEATH RRU E2 B29
/PROPOSED ANTENNAS a' OTHERS MOUNTED ON TOWER DETAILS, 2). SEE SHEET C-4 FOR
a . LEG NOT OCCUPIED BY DISH
J
232'-O"±
B/EXISTING ANTENNA L>`' I- PROPOSED ERICSSON RADIO EXISTING SELF-SUPPORT TOWER. SEE
Z 0206 MOUNTED BENEATH RRU I TABLE, THIS SHEET, FOR FACE WIDTH.
+I w E2 B29 (TYP OF 3). SEE I
o SHEET C-4 FOR DETAILS. 3 EXISTING CLIMBING LADDER
PROPOSED JUMPER BETWEEN BETA EXISTING SAFETY CLIMB
4415 RRU AND GAMMA ANTENNA a PROPOSED STANDOFF ANTENNA MOUNT
(TYP OF 2). SEE SHEET C-5 FOR
DETAILS. BY COMMSCOPE (P/N: P-200 OR
V APPROVED EQUIVALENT, TYP OF 3)
PROPOSED ANTENNA LAYOUT
N.T.S.
NOTE:
EXISTING DISH PROPOSED RET CABLE 4415 RRU TO ANTENNA (1) PER
119'-0"f BY OTHERS SECTOR. BETA SECTOR TO BE DAISY CHAINED TO GAMMA.
�/EXISTING DISH
EXISTING ANTENNA BY PROPOSED DISH PROPOSED 5" WIDE PROPOSED DISH
OTHERS (TYP) WIRELESS CABLE DISH WIRELESS ICE WIRELESS MTC4045GC
96'-0"f . LADDER. SEE SHEET BRIDGE. SEE SHEET ICE CANOPY
(�ROUTE (1) HYBRID CABLE /EXISTING ANTENNAS I TO PROPOSED DISH 1 C-4 FOR DETAILS. C-7 FOR DETAILS.
I \ I
80-0"t
WIRELESS RAD CENTER
qV I FI
/EXISTING ANTENNAS
A
PROPOSED DISH WIRELESS _ _ _ _ _ _
CABLE LADDER. SEE SHEET ► �;
C-4 FOR DETAILS. PROPOSED DISH
WIRELESS CABINET
EXISTING SELF-SUPPORT 1 PROPOSED
TOWER ROUTE (1) HYBRID CABLE 1 DISH WIRELESS
SEE EQUIPMENT ELEVATION, FROM PROPOSED DISH I EQUIPMENT
THIS SHEET, FOR DETAILS WIRELESS EQUIPMENT 1 PLATFORM
PLATFORM TO TOWER. SEE 1
TABLE, THIS SHEET, FOR
CABLE LENGTH. 1 1
0'-0" (REFERENCE) i 1,��
MV T/CONCRETE >\ \j \i af, s \r\\/\\f \f \ 4 \�\\j\\f ` \/ \r\�j�\\/\ \�j�\� f,' `\i\�/�`\1\ \� \\i/\\/\\{\\% X
��f
~rf rra�'�`;`r`/�i /r:: r,�i�✓i : r�� /\\r\ti/\\f�\ \/fir\\/\\/ ti \ {\/��i\� \�\ \` �`� .�\�j \` \\�\\\ \\i �� 4\ \\�\ \\ \\ �i \ \\j\\j\\fti�/�\i.
�� f14
�:f
FINAL TOWER ELEVATION EQUIPMENT ELEVATION
N.T.S. N.T.S.
ANTENNA LAYOUT NOTES:
1. THIS ANTENNA ORIENTATION PLAN IS
A SCHEMATIC, THE CONTRACTOR
SHALL VERIFY TOWER ORIENTATION
AND FIELD COORDINATE REQUIRED
ADJUSTMENTS TO ACHIEVE THE
DESIRED ANTENNA AZIMUTHS.
2. ANTENNA CENTERLINE HEIGHT
REFERENCED FROM GROUND AT
BASE OF TOWER, ASSUMING HEIGHT
OF 0'-0" AT SAID REFERENCE
POINT.
3. ALL ANTENNAS, CABLES AND
MOUNTS SHALL BE INSTALLED IN
ACCORDANCE WITH THE TOWER
ENGINEER'S RECOMMENDATIONS IN A
MANNER CONSISTENT WITH THE
STRUCTURAL ANALYSIS REPORT.
4. ALL ANTENNA BRACKETS PER
ANTENNA MANUFACTURER, OR
EQUAL. CONTRACTOR TO
COORDINATE REQUIRED MECHANICAL
DOWN TILT WITH DISH WIRELESS.
5. ALL ANTENNA INFORMATION TO BE
CONFIRMED WITH DISH WIRELESS RF
DESIGN PRIOR TO INSTALLATION.
6. VERIFY POSITIONS AND AZIMUTH OF
ANTENNAS WITH DISH WIRELESS
PRIOR TO INSTALLATION.
7. SECTOR FRAMES AND ANTENNAS
SHOULD HAVE IDENTIFYING TORQUE
MARKS SHOWN AFTER INSTALLATION.
B. ALL CLOSE—OUT PHOTOS ADHERE TO
CLOSE—OUT DOCUMENTATION.
9. THE SIZE, HEIGHT, AND DIRECTION
OF ALL ANTENNAS SHALL BE
ADJUSTED TO MEET SYSTEM
REQUIREMENTS DEPICTED BY THE
LATEST APPROVED RFDS.
IPMENT TESTiN
CONTRACTOR SHALL COMPLETE THE
FOLLOWING REQUIREMENTS:
1. ANTENNAS & RF JUMPERS:
• ALL RF JUMPERS & ANTENNA PORTS
MUST HAVE DOCUMENTED PASSING
SYSTEM SWEEP TEST.
• PIM TESTING IS REQUIRED FOR ALL
INSTALLED ANTENNAS & FEEDLINES.
• SYSTEM SWEEPS SHALL BE AT A
RETURN LOSS OF 5 —16db.
• ALL SWEEPS MUST BE PROVIDED IN
A PDF AS WELL AS ANRITSU (OR
EQUAL) DATA FILE FORMAT.
• FINAL ACCEPTANCE: PERFORM ALL
TECHNICAL TESTS SPECIFIED IN THE
CONSTRUCTION SOW. SECTION XIV
2. HYBRID CABLES:
• ALL FIBER PAIRS MUST HAVE A
DOCUMENTED PASSING POWER & A
FIBER INSPECTION SCOPE TEST.
• PASSING POWER TEST SHALL
BE 5 3db.
• REQUIRED FIBER TEST GEAR SHALL
BE VIAVI JDSU FIT—SD103; P5000i
FIBER SCOPE DIGITAL INSPECTION
KIT; VIAVI 2303/11, OLS -35
OPTICAL LASER LIGHT SOURCE
1310/1550 NM, SM,
INTERCHANGEABLE ADAPTER OR
EQUAL.
• ALL FIBER TEST RESULTS MUST BE
PROVIDED IN PDF FORMAT.
• FINAL ACCEPTANCE: PERFORM ALL
TECHNICAL TESTS SPECIFIED IN THE
CONSTRUCTION SOW, SECTION XIV
1. SCHEMATIC LAYOUT ONLY.
REFER TO SHEETS C-1 AND
C-2 FOR EXACT EQUIPMENT
LAYOUT, SIZES AND LOCATIONS
OF ICE BRIDGE.
2. ALL CABLE SUPPORTS SHOULD
BE BLOCKS WITH GROMMETS,
NO SNAP—INS ARE ALLOWED.
PREPARED FOR:
d,,
� s h
WIRELE S S
PREPARED BY:
i
J' l
1
inn
L.yys1A
n
1 R>_Gj5TERE0
PRoFFSSK�)NAL
f ENGINEER
i.
January 9, 2019
DRAWN BY: WKT
CHECKED BY: MJC
APPV'D: CSN
SUBMITTALS
DATE
DESCRIPTION
REV ISSUED BY
12-20-18
PRELIMINARY
0 CP
01-134-19
CONSTRUCTION
1 CP
01-09-19
CONSTRUCTION
2 CP
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS 15 PROPRIETARY BY NATURE.
REPRODUCTION OR CAUSING TO BE REPRODUCED
THE WHOLE OR ANY PART OF THESE DRAWINGS
WITHOUT THE PERMISSION OF
TOWER ENGINEERING PROFESSIONALS
IS PROHIBITED.
TEP NUMBER:
145629
DISH WIRELESS SITE ID:
AR0900004B
TOWER OWNER SITE ID:
AR09991-A
SITE ADDRESS:
227-D KEIGHTLY DRIVE
LITTLE ROCK, AR 72207
(PULASKI COUNTY)
SHEET TITLE:
TOWER ELEVATION &
ANTENNA LAYOUT
SHEET NUMBER: