HomeMy WebLinkAboutPC Minutes for Z-9767April 13, 2023
ITEM NO.: 2 FILE NO.: Z-9767
NAME: Phillips Duplexes – Conditional Use Permit
LOCATION: 4522 Malloy Street
DEVELOPER:
Stanley Phillips
6204 Sandy Lane
Little Rock, AR 72204
OWNER/AUTHORIZED AGENT:
Stanley Phillips – Owner/Applicant
SURVEYOR/ENGINEER:
Harbor Environmental
5800 Evergreen Drive
Little Rock, AR 72205
AREA: 0.50 acre NUMBER OF LOTS: 3 FT. NEW STREET: 0 LF
WARD: 6 PLANNING DISTRICT: 10 CENSUS TRACT: 24.05
CURRENT ZONING: R-3
VARIANCE/WAIVERS: None requested.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is requesting a conditional use permit to allow for the construction of
two (2) duplex structures on two (2) lots (one (1) per lot) at 4522 Malloy Street.
B. EXISTING CONDITIONS:
The property is located within a single family residential neighborhood which
contains a variety of housing types and sizes. The site is currently undeveloped
and mostly tree covered.
April 13, 2023
ITEM NO.: 2 (Cont.) FILE NO.: Z-9767
2
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 200 feet of the site and all neighborhood
associations registered with The City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS:
No comments.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water: NO OBJECTIONS; All Central Arkansas Water
requirements in effect at the time of request for water service must be met.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
April 13, 2023
ITEM NO.: 2 (Cont.) FILE NO.: Z-9767
3
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1.
Section D104.1 Buildings exceeding three stories or 30 feet in height.
Building or facilities exceeding 30 feet or three stories in height shall have at least
two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet
that have a single approved fire apparatus access road when all building are
equipped throughout with approved automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1
– D105.4
D105.1 Where Required. Where the vertical distance between the grade plane
and the highest roof surface exceed 30’, approved aerial fire apparatus access
roads shall be provided. For the purposes of this section the highest roof surfaces
shall be determined by measurement to the eave of a pitched roof, the intersection
of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting
this condition shall be located within a minimum of 15 feet and a maximum of
30 feet from the building, and shall be positioned parallel to one entire side of the
building. The side of the building on which the aerial fire apparatus access road is
positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over
the aerial fire apparatus access road or between the aerial fire apparatus road and
the building. Other obstructions shall be permitted to be places with the approval
of the fire code official.
April 13, 2023
ITEM NO.: 2 (Cont.) FILE NO.: Z-9767
4
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply with
all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times and
replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval by the fire code
official.
8. Electric gate operators, where provided, shall be listed in accordance with
UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram 501-918-
3756 Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
April 13, 2023
ITEM NO.: 2 (Cont.) FILE NO.: Z-9767
5
County Planning: No comments.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division: No comments.
H. ANALYSIS:
The applicant is requesting a conditional use permit to allow for the construction
of two (2) duplex structures on two (2) replatted lots (one (1) per lot) at 4522 Malloy
Street. The property is currently undeveloped and mostly tree covered. The
property is located at the northwest corner of Malloy and West 46th Streets.
The property is comprised of three (3) platted lots; Lots 10, 11 and 12, Block 5,
Euclid Place Addition. Each lot contains approximately 7,250 square feet of lot
area (0.166 acre). The applicant proposes to replat the lots into two (2) lots for
construction of a duplex on each lot. Each replatted lot will contain approximately
10,462 square feet of lot area (0.24 acre).
The applicant proposes to construct one (1) duplex structure on each of the
replatted lots. Each duplex structure will be 2,348 square feet in area and two (2)
stories in height. They will be thermal insulated, wood-frame structures, with vinyl
siding, thermal glazed windows and hip roofs with asphalt shingles on reinforced
concrete slabs.
The duplex structures will be located 40 feet back from the front (south) property
line, 9.75 feet to 20 feet back from the side property lines and 50 feet back from
the rear (north) property line. All proposed setbacks will conform with Section
36-255 (R-3 zoning standards) of the City’s Zoning Ordinance. The building
heights are not to exceed 35 feet.
The applicant is proposing eight (8) paved parking spaces (four (4) per duplex) to
be located within the front yard area, between the duplex structures and the West
46th Street property line. One (1) shared paved driveway from West 46 th Street will
serve as access to parking area. Section 36-502 requires a minimum of six (6)
April 13, 2023
ITEM NO.: 2 (Cont.) FILE NO.: Z-9767
6
parking spaces for the two (2) duplexes. The parking as proposed will be sufficient
to serve the development.
To staff’s knowledge, there are no outstanding issues associated with this
application. Staff believes the proposed duplex structures located at 4522 Malloy
Street are appropriate uses for this property. The duplex structures will only be a
minor increase in the original platted density for this property. The proposed
duplex structures will not be out of character with the general area. Other duplex
structures are located throughout the John Barrow Neighborhood. Staff believes
the proposed duplexes will have no adverse impact on the subdivision or
surrounding uses. The applicant is requesting no variances with the proposed
development.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested CUP, subject to compliance with the
comments and conditions outlined in paragraph E, and the staff analysis, in the
agenda staff report.
PLANNING COMMISSION ACTION: (APRIL 13, 2023)
The applicant was not present. There were no persons registered in opposition. Staff
presented the item and a recommendation of approval as outlined in the “staff
recommendation” above. The item remained on the consent agenda for approval as
recommended by staff, including all staff comments and conditions. The vote was 7 ayes,
0 nays, 3 absent and (1) open position.