HomeMy WebLinkAboutZ-6051-J Staff AnalysisFILE NO.: Z-6051
NAME: Arkansas Systems Tract 4, Long -form PCD
LOCATION: Located on the East side of Chenal Parkway and South of Systems Drive
DEVELOPER.
Arkansas Systems Land Company, LLC
425 West Capitol Avenue, Suite 300
Little Rock, AR 72201
ENGINEER:
White Daters and Associates
24 Rahling Circle
Little Rock, AR 72223
AREA: 5.11 acres
CURRENT ZONING:
ALLOWED USES:
PROPOSED ZONING
PROPOSED USE:
NUMBER OF LOTS: 2
PCD
FT. NEW STREET: 0 LF
C-3, General Commercial District and a specific listing of
additional uses
PCD
C-3, General Commercial District and a specific listing of
additional uses
VARIAN CENVAIVERS,
1. A variance Section 36-341 to allow parking over the box culvert and in the
floodway.
2. A variance from the City's Land Alteration Ordinance to allow grading of the entire
site with construction of the proposed box culvert and creek relocation, as per the
approved 404 permit.
3. A variance from Sections 30-43 and 31-210 to allow the drive on Arkansas Systems
Drive nearer the property line than typically allowed per ordinance.
FILE NO.: Z -6051-J
BACKGROUND:
On December 21, 1998, the Board of Adjustment reviewed and approved a request to
allow a variance from the floodway/floodplain restrictions of Chapter 8 and 36 to permit
construction of a parking lot in the floodway for Lots 4 and 5 of the Arkansas Systems
Office Park Addition. The applicant proposed construction of an office building on Lot 5,
which has been constructed. The applicant proposed to contain the drainage in
underground culverts and to utilize the area designated as floodway for parking and
driveways. As a condition of approval, the applicant was required to provide CORPS
approval of hydraulic calculations containing the 100 -year floodway in the proposed
underground structure, conditional letter of approval from FEMA, parking lot elevation to
allow storm events above the 100 year to pass without endangering the building and
dedication of a drainage easement to contain the floodway. No development was
proposed for Lot 4 and the site remains undeveloped.
Ordinance No. 19,578 adopted by the Little Rock Board of Directors on August 15,
2006, rezoned the site from 0-2, Office and Institutional District to PCD, Planned
Commercial Development. The approval allowed the development of this 5.11 acre
tract with a two (2) lot plat and the construction of a branch bank facility and a three (3)
story mixed use building on the individual lots through a Planned Office Development.
The office building was proposed for Lot 4A consisting of a total of 60,750 square feet of
space with 20,250 square feet of potential retail space, all retail space was contained on
the first floor and 40,500 square feet of office space. A total of 213 parking spaces were
proposed to serve the office building. Lot 413 was proposed for the branch bank facility
with a total of 2,600 square feet of space and 47 parking spaces. Cross access and
parking would be provided between the two (2) lots.
Ordinance No. 20,821 adopted by the Little Rock Board of Directors on December 17,
2013, allowed a revision to the previously approved PCD (Z -6015-A). The approval
allowed the creation of a two (2) lot plat. An office building was approved for one lot
and a small restaurant with drive through service was proposed for the second lot. The
two (2) lots were to share a common drive and parking area. All driveways on the site
were to be included in a cross access easement.
Lot 4A was proposed containing 3.7 -acres, 184 parking spaces, 18,375 square feet of
building coverage and a maximum of three (3) stories and 55,125 square feet of
building area. The site plan included the option for placement of a pick-up window on
the eastern end of the building. Lot 4B was proposed containing 1.4 -acres, 67 parking
spaces and 4,300 square feet of building area. The use was proposed as a restaurant
with drive through service. The applicant requested a waiver of the screening
requirement for the order menu boards.
The uses proposed for the development were as follows: All permitted uses identified
within the C-3, General Commercial Zoning District and the following additional items -
Food store under five thousand (5,000) square feet of gross floor area, with the sale of
beer or wine, private club with dining or bar service, hospital, medical clinic with
ambulatory service. The proposal excluded the following uses: Animal clinic
(enclosed), Auto parts and accessories, Cabinet and woodwork shop, College
2
FILE NO.: Z -6051-J Cont.
dormitory, College fraternity or sorority, Convenience food store with gas pumps,
Convent or monastery, Job printing, lithographer, printing or blueprinting, Taxidermist.
The maximum commercial proposed is limited to 18,375 square feet located on Lot 4A.
The redevelopment of the site has not occurred.
A. PRO POSAUREQUEST/AP PLICANT'S STATEMENT:
The applicant is now proposing to revise and reestablish the PCD zoning. The
project includes two (2) lots. The uses proposed for the development are as
follows: All permitted uses identified within the C-3, General Commercial Zoning
District and the following additional items - Food store under five thousand
(5,000) square feet of gross floor area, with the sale of beer or wine, private club
with dining or bar service, hospital, medical clinic with ambulatory service. The
proposal excluded the following uses: Animal clinic (enclosed), Auto parts and
accessories, Cabinet and woodwork shop, College dormitory, College fraternity
or sorority, Convenience food store with gas pumps, Convent or monastery, Job
printing, lithographer, printing or blueprinting, Taxidermist.
Lot 4A is proposed containing 3.3 -acres with 18,375 square feet of building
coverage and a maximum building area of 55,125 square feet. The building is
proposed with one (1), two (2) or three (3) stories in height. The plan indicates
178 parking spaces. The commercial uses will not exceed the area of the first
floor. A portion of Lot 4A may also be used with a restaurant use. The mix of
uses will not exceed the available parking on the site.
The development of Lot 4B is proposed with 1.4 -acres and a 4,300 square foot
building with a drive-through window. The plan indicates 67 parking spaces.
The applicant has indicated the building on Lot 4B as a restaurant with
drive-through service or as a sit-down restaurant with exterior dining. If the lot is
developed without the drive-through window the building area proposed is
7,800 square feet with 98 parking spaces.
The request includes a variance from Section 36-341 to allow vehicle parking
over the box culvert and in the floodway. The request also includes a variance
from the City's Land Alteration Ordinance to allow grading of the entire site with
construction of the proposed box culvert and creek relocation, as per the
approved 404 permit. The request includes a variance from Sections 30-43 and
31-210 to allow the drive on Arkansas Systems Drive nearer the property line
than typically allowed per ordinance.
B. EXISTING CONDITIONS:
The site is a partially wooded site located at the southeast corner of Arkansas
Systems Drive and Chenal Parkway. The area has developed as an office
complex with a retail center located to the south. The area to the northwest is a
C-2 zoned site currently developing as a shopping center. To the west of the site
is vacant property currently under review for a Planned Commercial
141
FILE NO.: Z-6051-JCont.
Development for the placement of a branch bank facility and a restaurant.
Further west is property developing as St. Vincent's West Medical campus.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has not received any comment from area property owners.
All property owners located within 200 -feet of the site were notified of the public
hearing. There is not an active City of Little Rock recognized neighborhood
association located in this immediate area.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Chenal Parkway is classified on the Master Street Plan as a principal
arterial. Dedication of right-of-way to 55 feet from centerline will be required.
2. Sidewalks with appropriate handicap ramps are required in accordance with
Section 31-175 of the Little Rock Code and the Master Street Plan.
Sidewalks should be installed along Chenal Parkway.
3. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
4_ A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading, and drainage plans will need to be submitted and approved prior to
the start of construction. Is advanced grading requested to occur on the
site?
5. Stormwater detention ordinance applies to this property. Show the
proposed location for stormwater detention facilities on the plan.
6. If disturbed area is one (1) or more acres, obtain a NPDES stormwater
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
7. Alteration of the water course will require approval from the Little Rock
District of the US Army Corps of Engineers prior to start of work.
8. The existing curb along Arkansas Systems Drive and the median at
Chenal Parkway has been painted red and signed as a "Fire Lane".
No records show the public street functions as a fire lane. The paint should
be removed.
9. A special Grading Permit for Flood Hazard Areas will be required per
Section 8-283 prior to construction.
% The minimum Finish Floor elevation of at least one (1) foot above the
proposed base flood elevation is required to be shown on plat and grading
plans for Lot 4A and 413. At time of construction and prior to issuance of the
final certificate of occupancy, an elevation certificate will be required to be
provided.
4
FILE NO.: Z -6051-J Cont.
11. In accordance with Section 31.176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25 foot
wide access easement is required adjacent to the floodway boundary.
12. The base flood elevations show to be below the bottom of the ditch. The
majority of the channel adjacent to the subject property shows to be in the
floodplain with the channel upstream shown to be in the floodway. Prior to
issuance of a grading permit, a "No Rise Certification" based on the
proposed conditions must be provided to staff for review and approval.
13. Per City code, Section 36-341, vehicle parking is restricted from being
provided in the floodway. A variance must be requested.
14. Damage to public and private property due to hauling operations or
operation of construction related equipment from a nearby construction site
shall be repaired by the responsible party prior to issuance of a certificate of
occupancy.
15. Design plans for piping system must be submitted to staff for approval prior
to issuance of a grading permit. The proposed piping must be placed within
a drainage easement. What is the proposed ditch section design?
16. Streetlights are required by Section 31-403 of the Little Rock code. Provide
plans for approval to Traffic Engineering. Streetlights must be installed prior
to platting/certificate of occupancy. Contact Traffic Engineering
501.379.1813, Greg Simmons (gsimmons@littlerock.org) for more
information. Streetlights do not appear to be installed along Arkansas
Systems Drive.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available to this project. EAD Plan Review required for
food service. Contact Little Rock Wastewater Utility for additional information.
Entergy: Entergy does not object to this proposal. A three phase underground
power line exists to the north of this property across Systems Drive. Contact
Entergy in advance regarding future service requirements to the development,
line extension, and future facilities locations as this project proceeds
CenterPoint Ener : No comment received.
AT & T: No comment received.
Central Arkansas Water:
All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
5
FILE NO.: Z -6051-J Cont.
2. The Little Rock Fire Department needs to evaluate this site to determine
whether additional public and/or private fire hydrant(s) will be required. If
additional fire hydrant(s) are required, they will be installed at the
Developer's expense.
3. Please submit plans for water facilities and/or fire protection system to
Central Arkansas Water for review. Plan revisions may be required after
additional review. Contact Central Arkansas Water regarding procedures
for installation of water facilities and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering Division and the Little Rock
Fire Department is required.
4. A Capital Investment Charge based on the size of meter connection(s) will
apply to this project in addition to normal charges. This fee will apply to all
connections including metered connections off the private fire system.
5. If there are facilities that need to be adjusted and/or relocated, contact
Central Arkansas Water. That work would be done at the expense of the
developer.
6. Contact Central Arkansas Water regarding the size and location of water
meter.
7. Due to the nature of this facility, installation of an approved reduced
pressure zone backflow preventer assembly (RPZA) is required on the
domestic water service. This assembly must be installed prior to the first
point of use. Central Arkansas Water requires that upon installation of the
RPZA, successful tests of the assembly must be completed by a Certified
Assembly Tester licensed by the State of Arkansas and approved by
Central Arkansas Water. The test results must be sent to Central Arkansas
Water's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 501.377.1226
if you would like to discuss backflow prevention requirements for this
project.
8. The facilities on-site will be private. When meters are planned off private
lines, private facilities shall be installed to Central Arkansas Water's
materials and construction specifications and installation will be inspected
by an engineer, licensed to practice in the State of Arkansas. Execution of
a Customer Owned Line Agreement is required.
9. Fire sprinkler systems which do not contain additives such as antifreeze
shall be isolated with a double detector check valve assembly. If additives
area used, a reduced pressure zone back flow preventer shall be required.
10. This development will have minor impact on the existing water distribution
system. Proposed water facilities will be sized to provide adequate
pressure and fire protection.
D
FILE NO.: Z -6051-J Cont.
Fire Department: Maintain Access:
Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as
per Appendix ❑ of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is located on a
fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012
Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with
Central Arkansas Water (Jason Lowder 501.377.1245) and the Little Rock Fire
Marshal's Office (Captain Tony Rhodes 501.918.3757). Number and Distribution
of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comment received.
County Plannin : No comment.
CATA: The site is not located on a dedicated CATA Bus Route
F. ISSUESITECHNICAL/DESIGN:
Building Code: Project is subject to full commercial plan review and approval
prior to issuance of a building permit. For information on submittal requirements
and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichey( littlerock.ar� or
Mark Alderfer at 501.371.4875; mald ?rfer0Dlittlerock.or .
Planning Division: This request is located in the Chenal Planning District. The
Land Use Plan shows Mixed Office Commercial (MOC) for this property.
The Mixed Office Commercial category provides for a mixture of office and
commercial uses to occur. Acceptable uses are office or mixed office and
commercial. A Planned Zoning District is required if the use is mixed office and
commercial. The applicant has applied for a rezoning from PCD (Planned
Commercial District) to PCD (Planned Commercial District) to allow for the
development of two (2) buildings on the site. The proposed development is
within the Chenal Design Overlay District and signage has special
recommendations.
Master Street Plan: Chenal Parkway is shown as a Principal Arterial and
Systems Drive is shown as a Collector on the Master Street Plan. A Principal
Arterial is to serve through traffic and to connect major traffic generators or
activity centers within the urbanized area. Entrances and exits should be limited
to minimize negative effects of traffic and pedestrians on Chenal Parkway since it
is a Principal Arterial. The primary function of a Collector Street is to provide a
connection from Local Streets to Arterials. These streets may require dedication
7
FILE NO.: Z-605
of right-of-way and may require street improvements for entrances and exits to
the site.
Bicycle Pian: A Class I Bike Path is shown along Chenal Parkway. A Bike Path
is to be a paved path physically separate for the use of bicycles. Additional
right-of-way or an easement is recommended. Nine -foot (9') paths are
recommended to allow for pedestrian use as well (replacing the sidewalk).
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements.
2. Screening requirements will need to be met for the vehicular use areas
adjacent to street right-of-ways. Provide screening shrubs with an average
linear spacing of not less at three (3) feet within the required landscape area.
Provide trees with an average linear spacing of not less than thirty (30) feet.
3. A perimeter planting strip is required along any side of a vehicular use area
that abuts adjoining property or the right-of-way of any street. This strip shall
be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall
be planted for every thirty (30) linear feet of perimeter planting strip.
4. Building landscape areas shall be provided at the rate equivalent to planter
strip three (3) feet wide along the vehicular use area. One (1) tree and
four (4) shrubs shall be planted in the building landscape areas for each
forty (40) linear feet of vehicular use area abutting the building.
5. An irrigation system shall be required for developments of one (1) acre or
larger
6. The City Beautiful Commission recommends
trees as feasible on this site. Credit toward
requirements can be given when preserving
larger.
G. SUBDIVISION COMMITTEE COMMENT:
preserving as many existing
fulfilling Landscape Ordinance
trees of six (6) inch caliper or
(August 5, 2015)
Mr. Tim Daters and Mr. Hank Kelly were present representing the request.
Staff presented an overview of the item stating there were additional items
necessary to complete the review process. Staff questioned if the proposed uses
were the same as with the previous approval. Staff also questioned the building
height for the building located on Lot 4A. Staff questioned the proposed use mix
of the building located on Lot 4A. Staff also questioned the days and hours of
operation for the development.
Public Works comments were addressed. Staff stated to allow parking within the
floodway would require a variance. Staff also stated to allow the driveway on
Arkansas Systems Drive would require a variance from the master street plan
and the subdivision ordinance. Staff stated the plans for the piping system were
FILE NO.: Z -6051-J (Co
to be submitted to staff for review and approval prior to construction. Staff stated
a grading permit was required prior to any land clearing or grading activities on
the site.
Landscaping comments were addressed. Staff stated screening of the vehicular
use area was required from the street right of ways. Staff also stated building
landscaping would be required at the time of development. Staff stated an
automatic irrigation system was required to water landscaped areas. Staff stated
the minimum perimeter planting strip of nine (9) feet was required adjacent to
paved areas.
Staff noted the comments from the various other agencies. There were no more
issues for discussion. The Committee then forwarded the item to the full
Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan and cover letter to staff addressing
the issues raised at the August 5, 2015, Subdivision Committee meeting. The
applicant has provided the proposed use mix of the building, the proposed days
and hours of operation and the building height for the proposed building located
on Lot 4A.
The request is to allow the development of this site with flexibility for the future
construction. The project includes two (2) lots, Lots 4A and 4B. Lot 4A is
proposed containing 3.3 -acres with 18,375 square feet of building coverage and
a maximum building area of 55,125 square feet. The building is proposed with
one (1), two (2) or three (3) stories in height with a maximum building height of
45 -feet. The site plan indicates 178 parking spaces located on Lot 4A.
The development of Lot 4B is proposed with 1.4 -acres and a 4,300 square foot
building with a drive-through window. The plan indicates 67 parking spaces.
The applicant has indicated the building on Lot 4B as a restaurant with
drive-through service or as a sit-down restaurant with exterior dining. If the lot is
developed without the drive-through window the building area proposed is
7,800 square feet with 98 parking spaces. The applicant has requested should
the lot develop with a drive-through restaurant the order menu board not require
screening as typically required within the commercial district of the zoning
ordinance.
The uses proposed for the development are as follows: All permitted uses
identified within the C-3, General Commercial Zoning District and the following
additional items - Food store under five thousand (5,000) square feet of gross
floor area, with the sale of beer or wine, private club with dining or bar service,
hospital, medical clinic with ambulatory service. The proposal excluded the
following uses: Animal clinic (enclosed), Auto parts and accessories, Cabinet
and woodwork shop, College dormitory, College fraternity or sorority,
9
FILE NO.: Z -6051-J Cont.
Convenience food store with gas pumps, Convent or monastery, Job printing,
lithographer, printing or blueprinting, Taxidermist. The commercial uses will not
exceed the area of the first floor on Lot 4A, (18,375 square feet). A portion of Lot
4A may be used with a restaurant use. The mix of uses located within the
building on Lot 4A will not exceed the available parking on the site.
The request includes a Section 36-341 to allow vehicle parking over the box
culvert and in the floodway. The zoning ordinance states floodways shall be kept
free of structural involvement including fences, open storage of materials and
equipment, vehicle parking and other impediments to the free flow of floodwater.
Exceptions may be granted when existing topography is at or above the existing
one -hundred -year flood level and when the velocity of flow is less than three (3)
feet per second. The applicant has an approved 404 permit from the Corp of
Engineers which will allow rechannelization of the creek on this site and limit the
potential impact of parking within the floodway.
The request also includes a variance from the City's Land Alteration Ordinance to
allow grading of the entire site with construction of the proposed box culvert and
creek relocation, as per the approved 404 permit. The applicant has stated
grading of the entire site is necessary to allow the site to balance and eliminate
the need for moving material to and from the site at the time of construction of
the buildings.
The request includes a variance from Sections 30-43 and 31-210 to allow the
drive on Arkansas Systems Drive nearer the property line than typically allowed
per ordinance. The ordinance typically requires driveways to be a minimum of
150 -feet from the property line. The drive as indicated is 10 -feet from the
property line. Staff is supportive of the driveway and the placement due to the
location of other drives on Arkansas Systems Drive and staff does not feel there
will be any conflicting movements from adjacent properties if constructed as
proposed.
The site plan includes the placement a ground signage on both Chenal Parkway
and Arkansas Systems Drive. Each of the lots are proposed with a sign along
Chenal Parkway. The signs are proposed with a maximum height of eight (8)
feet and a maximum sign area of one hundred (100) square feet. A sign on Lot
4A is proposed at the entrance drive on Arkansas Systems Drive. The sign is
proposed also eight (8) feet in height and one hundred (100) square feet in area.
Staff is supportive of the request. The site is indicated as Mixed Office
Commercial on the City's Future Land Use Plan. The applicant is proposing to
develop the site to serve the existing office community and nearby residential
uses located in the area. The site plan as proposed allows the developer
flexibility to develop the site with office, retail and/or residential uses. To staff's
knowledge there are no remaining outstanding technical issues associated with
the request. Staff feels the development as proposed is appropriate.
10
LE NO.: Z -6051-J (Cont.
STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda
staff report.
Staff recommends approval of the waiver request for the screening requirement
of the order menu boards.
Staff recommends the uses of the building located on Lot 4A match the parking
available on the site based on a parking ratio of one (1) parking space per
225 gross square feet of floor area.
Staff recommends approval of the following variance requests:
1. A variance Section 36-341 to allow parking over the box culvert and in the
floodway.
2. A variance from the City's Land Alteration Ordinance to allow grading of the
entire site with construction of the proposed box culvert and creek relocation,
as per the approved 404 permit.
3. A variance from Sections 30-43 and 31-210 to allow the drive on Arkansas
Systems Drive nearer the property line than typically allowed per ordinance.
PLANNING COMMISSION ACTION: (AUGUST 27, 2015)
The applicant was present. There were no registered objectors present. Staff
presented the item with a recommendation of approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E and F of
the agenda staff report. Staff presented a recommendation of approval of the
applicant's request for a waiver of the screening requirement of the order menu boards.
Staff presented a recommendation the uses of the building located on Lot 4A match the
parking available on the site based on a parking ratio of one (1) parking space per
225 gross square feet of floor area.
Staff presented a recommendation of approval of the following variance requests:
1. A variance Section 36-341 to allow parking over the box culvert and in the
floodway.
2. A variance from the City's Land Alteration Ordinance to allow grading of the
entire site with construction of the proposed box culvert and creek relocation, as
per the approved 404 permit.
3. A variance from Sections 30-43 and 31-210 to allow the drive on Arkansas
Systems Drive nearer the property line than typically allowed per ordinance.
11
FILE NO.: Z -6051-J (Cont_
There was no further discussion. The item was placed on the consent agenda and
approved as recommended by staff by a vote of 11 ayes, 0 noes and 0 absent.
12
ITEM NO.: 7, Z-6051 -J
NAME: Arkansas Systems Tract 4, Long -form PCD
LOCATION: located on the East side of Chenal Parkway and South of Systems Drive
Planning Staff Comments:
1. Provide notification of the property owners located within 200 -feet of the
development including the certified abstract list, notice form with affidavit executed
and proof of mailing. The notice must be mailed no later than August 12, 2015. The
Office of Planning and Development must receive the proof of notice no later than
August 21, 2015.
2. The previous approval allowed the following — are these the uses and exclusions a
part of the request?
a. The uses proposed for the development are as follows: All permitted uses
identified within the C-3, General Commercial Zoning District and the
following additional items - Food store under five thousand (5,000) square
feet of gross floor area, with the sale of beer or wine, private club with
dining or bar service, hospital, medical clinic with ambulatory service. The
proposal excludes the following uses: Animal clinic (enclosed), Auto parts
and accessories, Cabinet and woodwork shop, College dormitory, College
fraternity or sorority, Convenience food store with gas pumps, Convent or
monastery, Job printing, lithographer, printing or blueprinting, Taxidermist.
The maximum commercial proposed is limited to 18,375 square feet
located on Lot 4A.
3. Is the building located on Lot 4A a single story building? Provide the maximum
building height.
4. What is the percentage of use mix proposed for the building on Lot 4A?
5. Will the restaurant have an area for order pick-up? Note on the site plan.
6. Provide the proposed building signage plan. Provide the facades proposed with
building signage.
7. Provide a site lighting plan. All site lighting must be low-level and directional, aimed
downward and into the site.
8. Provide the days and hours of operation for the proposed development.
9. Provide the days and hours of dumpster service for the development.
10. Provide the proposed phasing plan.
11. If the area of outdoor dining is proposed fenced indicate on the site plan fencing to
be provided per City and State requirements to allow alcohol consumption within the
dining area.
12. Provide the percentage of building coverage, the percentage of paved area and the
percentage of landscape area.
Variance/Waivers:
1. Section 36-341, vehicle parking is restricted from being provided in the floodway
2. Advanced grading
3. Driveway location
Public Works Conditions:
1. Chenal Parkway is classified on the Master Street Plan as a principal arterial.
Dedication of right-of-way to 55 feet from centerline will be required.
2. Sidewalks with appropriate handicap ramps are required in accordance with Section
31-175 of the Little Rock Code and the Master Street Plan. Sidewalks should be
installed along Chenal Parkway.
3. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-
of-way prior to occupancy.
4. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Site grading, and drainage plans
will need to be submitted and approved prior to the start of construction. Is
advanced grading requested to occur on the site?
5. Stormwater detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan.
6. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
7. Alteration of the water course will require approval from the Little Rock District of the
US Army Corps of Engineers prior to start of work.
8. The existing curb along Arkansas Systems Drive and the median at Chenal Parkway
has been painted red and signed as a "Fire Lane". No records show the public
street functions as a fire lane. The paint should be removed.
9. A special Grading Permit for Flood Hazard Areas will be required per Section 8-283
prior to construction.
10. The minimum Finish Floor elevation of at least one (1) foot above the proposed base
flood elevation is required to be shown on plat and grading plans for Lot 4A and4B.
At time of construction and prior to issuance of the final certificate of occupancy, an
elevation certificate will be required to be provided.
11. In accordance with Section 31-176, floodway areas must be shown as floodway
easements or be dedicated to the public. In addition, a 25 foot wide access
easement is required adjacent to the floodway boundary.
12. The base flood elevations show to be below the bottom of the ditch. The majority of
the channel adjacent to the subject property shows to be in the floodplain with the
channel upstream shown to be in the floodway_ Prior to issuance of a grading
permit, a "No Rise Certification" based on the proposed conditions must be provided
to staff for review and approval.
13. Per City code, Section 36-341, vehicle parking is restricted from being provided in
the floodway. A variance must be requested?
14. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by
the responsible party prior to issuance of a certificate of occupancy.
15. Design plans for piping system must be submitted to staff for approval prior to
issuance of a grading permit. The proposed piping must be placed within a drainage
easement. What is the proposed ditch section design?
16. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans
for approval to Traffic Engineering. Streetlights must be installed prior to
platting/certificate of occupancy. Contact Traffic Engineering 501.379.1813, Greg
Simmons (gsimmions@littlerock.org) for more information. Streetlights do not
appear to be installed along Arkansas Systems Drive.
Utilities and Fire Department/County Planning:
Wastewater:
Enteral-: Entergy does not object to this proposal. A three phase underground
power line exists to the north of this property across Systems Drive. Contact Entergy in
advance regarding future service requirements to the development, line extension, and
future facilities locations as this project proceeds
CenterPoint Energy-:
CenterPoint Energy: No comment received.
AT & T: No comment received.
1. All Central Arkansas Water requirements in effect at the time of request for water
service must be met.
2. The Little Rock Fire Department needs to evaluate this site to determine whether
additional public and/or private fire hydrant(s) will be required. If additional fire
hydrant(s) are required, they will be installed at the Developer's expense.
3. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional review.
Contact Central Arkansas Water regarding procedures for installation of water
facilities and/or fire service. Approval of plans by the Arkansas Department of
Health Engineering Division and the Little Rock Fire Department is required.
4. A Capital Investment Charge based on the size of meter connection(s) will apply to
this project in addition to normal charges. This fee will apply to all connections
including metered connections off the private fire system.
5. If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
6. Contact Central Arkansas Water regarding the size and location of water meter.
7. Due to the nature of this facility, installation of an approved reduced pressure zone
backflow preventer assembly (RPZA) is required on the domestic water service.
This assembly must be installed prior to the first point of use. Central Arkansas
Water requires that upon installation of the RPZA, successful tests of the assembly
must be completed by a Certified Assembly Tester licensed by the State of Arkansas
and approved by Central Arkansas Water. The test results must be sent to Central
Arkansas Water's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 501.377.1226 if you
would like to discuss backflow prevention requirements for this project.
8. The facilities on-site will be private. When meters are planned off private lines,
private facilities shall be installed to Central Arkansas Water's materials and
construction specifications and installation will be inspected by an engineer, licensed
to practice in the State of Arkansas. Execution of a Customer Owned Line
Agreement is required.
9. Fire sprinkler systems which do not contain additives such as antifreeze shall be
isolated with a double detector check valve assembly. If additives area used, a
reduced pressure zone back flow preventer shall be required.
10. This development will have minor impact on the existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire
protection.
Fire Department: Maintain Access:
Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access
road width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water
(Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Captain Tony
Rhodes 501.918.3757). Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comment received.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
Building Code: Project is subject to full commercial plan review and approval prior to
issuance of a building permit. For information on submittal requirements and the review
process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichey@ Iittlerock. or or
Mark Alderfer at 501.371.4875; malderfer littlerock.ar .
Planning Division: This request is located in the Chenal Planning District. The Land
Use Plan shows Mixed Office Commercial (MOC) for this property. The Mixed Office
Commercial category provides for a mixture of office and commercial uses to occur.
Acceptable uses are office or mixed office and commercial. A Planned Zoning District is
required if the use is mixed office and commercial. The applicant has applied for a
rezoning from PCD (Planned Commercial District) to PCD (Planned Commercial
District) to allow for the development of two (2) buildings on the site. The proposed
development is within the Chenal Design Overlay District and signage has special
recommendations.
Master Street Plan: Chenal Parkway is shown as a Principal Arterial and Systems Drive
is shown as a Collector on the Master Street Plan. A Principal Arterial is to serve
through traffic and to connect major traffic generators or activity centers within the
urbanized area. Entrances and exits should be limited to minimize negative effects of
traffic and pedestrians on Chenal Parkway since it is a Principal Arterial. The primary
function of a Collector Street is to provide a connection from Local Streets to Arterials.
These streets may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
Bicycle Plan: A Class I Bike Path is shown along Cantrell Road. A Bike Path is to be a
paved path physically separate for the use of bicycles. Additional right-of-way or an
easement is recommended. Nine -foot (9') paths are recommended to allow for
pedestrian use as well (replacing the sidewalk).
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance requirements.
2. Screening requirements will need to be met for the vehicular use areas adjacent to
street right-of-ways. Provide screening shrubs with an average linear spacing of not
less at three (3) feet within the required landscape area. Provide trees with an
average linear spacing of not less than thirty (30) feet.
3. A perimeter planting strip is required along any side of a vehicular use area that
abuts adjoining property or the right-of-way of any street. This strip shall be at least
nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for
every thirty (30) linear feet of perimeter planting strip.
4. Building landscape areas shall be provided at the rate equivalent to planter strip
three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs
shall be planted in the building landscape areas for each forty (40) linear feet of
vehicular use area abutting the building.
5. An irrigation system shall be required for developments of one (1) acre or larger
6. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
Revised plat/plan-, Submit four (4) copies of a revised preliminary plat/plan (to include
the additional information as noted above) to staff on Wednesday, August 12, 2015.