HomeMy WebLinkAboutZ-5781-A Map 20EXTERIOR WALL RAIN SENSOR FREEZE SENSOI "SENSOR WIRING CONDUIT NOTE: I. FOR COMPLETE INSTALLATION INSTRUCTIONS, SEE INSTRUCTIONS ENCLOSED WITH RAIN SENSOR FINISH GRADE/TOP OF MULCH QUICK -COUPLING VALVE: RAIN BIRD MODEL 5RC VALVE BOX WITH COVER: 6 -INCH SIZE 3 -INCH MINIMUM DEPTH OF 3/4 -INCH WASHED GRAVEL PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) BRICK (1 OF 2) PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) SCH 40 STREET ELL SCH 40 TEE OR ELL MAINLINE PIPE \ ' PVC SCH 40 ELL PVC SCH 40 STREET ELL 2" x 2" REDWOOD STAKE W/ STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT NOTE: SUPPORT SYSTEM 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE. 30 CH LINEAR LENGTH OF WIRE, IRRIGATION NOTES COILED 1) LOCATE HEADS, LINES AND WIRING ALONG BACK OF CURBS AND BED EDGES. WATER PROOF CONNECTION COMBINE LINES AND WIRING IN COMMON TRENCHES WHERE POSSIBLE. PLACE HEADS (1 OF 2) DIRECTLY ADJACENT TO CURBS AND EDGES. PLACE VALVES IN ACCESSIBLE LOCATIONS. ID TAG NO LINES ARE TO BE PLACED UNDER VEHICULAR PAVING AREAS UNLESS IN IRRIGATION VALVE BOX WITH COVER: SLEEVES. 12 -INCH SIZE FINISH GRADE/TOP OF MULCH NOTES: REMOTE CONTROL VALVE: 2) CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ALL UTILITIES DURING THE RAIN BIRD PEB 3" RAIN BIRD MODEL SP -100 `MIN. PVC SCH SO NIPPLE (CLOSE) PVC SCH 40 ELL PVC LATERAL PIPE PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) %0v r� BRICK (1 OF 4) SCH 80 NIPPLE (2 -INCH LENGTH, HIDDEN) AND SCH 40 ELL �TNt,/IIU114ia17ii� PVC SCH 40 TEE OR ELL PVC SCH 40 MALE ADAPTER PVC LATERAL PIPE 3.0 -INCH MINIMUM DEPTH OF 3/4 -INCH WASHED GRAVEL 112 -INCH MALE NPT x.490 INCH BARB ELBOW: RAIN BIRD MODEL SBE -050 3) CONTRACTOR SHALL OBTAIN ANY REQUIRED PERMITS, ADHERE TO ALL MUNICIPAL CODES AND FOLLOW STANDARD AND ACCEPTED LOCAL PRACTICES. PVC SCH 40 TEE OR ELL 4) AN AUTOMATIC DRAIN VALVE SHALL BE INSTALLED AT THE LOWEST PORTION OF EACH PVC LATERAL PIPE ZONE AND AT 100' INTERVALS ON THE MAINLINE (SEE DETAIL). BARB E MALE NPT x.490 BIRD CH 5) VALVE WIRING SHALL BE 14 GAUGE SINGLE STRAND COPPER DIRECT BURIAL BARB ELBOW: RAIN BIRD MODEL SBE -050 IRRIGATION WIRE. PROVIDE (1) ONE WHITE WIRE AS THE COMMON FOR ALL THE VALVES. PROVIDE (1) ONE NON-WHITE WIRE FOR EACH OF THE ZONE VALVES. ALSO PROVIDE (1) ON NON-WHITE WIRE FOR ALL THE VALVES TO BE USED AS A SPARE. ALL SPLICES SHALL BE WATERPROOF AND PLACED AT VALVE LOCATIONS ONLY. 1) AUTOMATIC RAIN SHUTOFF �4) QUICK -COUPLING VALVE L7) REMOTE CONTROL VALVE (10) POP-UP SPRAY HEAD SHRUB AREAS � OUTSIDE WALL HYBRID CONTROLLER: RAIN BIRD ESP -LX SERIES OUTDOOR WALL MOUNT 1 -5 -INCH PVC, SCH 40 CONDUIT AND FITTINGS JUNCTION BOX WIRES TO REMOTE. CONTROL VALVES 1 -INCH PVC SCH 40 CONDUIT AND FITTINGS TO POWER SUPPLY SECTION VIEW MAINLINE, LATERAL, MAINLINE LATERAL WIRING IN AND WIRING IN PIPE PIPE CONDUIT THE SAME TRENCH PLAN VIEW WIRE W/0 CONDUIT RUN WIRING BENEATH IRRIGATION NOTES TIE A 24 -INCH LOOP IN 1) LOCATE HEADS, LINES AND WIRING ALONG BACK OF CURBS AND BED EDGES. PLANT MATERIAL COMBINE LINES AND WIRING IN COMMON TRENCHES WHERE POSSIBLE. PLACE HEADS TAPE AND BUNDLE AT DIRECTLY ADJACENT TO CURBS AND EDGES. PLACE VALVES IN ACCESSIBLE LOCATIONS. FINISH GRADE/TOP OF MULCH NO LINES ARE TO BE PLACED UNDER VEHICULAR PAVING AREAS UNLESS IN IRRIGATION POP-UP SPRAY SPRINKLER: SLEEVES. RAIN BIRD 1812 SAM -PRS W/ VAN NOZZLE NOTES: 2) CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ALL UTILITIES DURING THE SWING PIPE, 12 -INCH LENGTH: INSTALLATION. CONTRACTOR SHALL SEEK ASSISTANCE FROM THE LOCAL UTILITIES IN RAIN BIRD MODEL SP -100 THE LOCATION OF THE UTILITIES PRIOR TO EXCAVATION. 112 -INCH MALE NPT x.490 INCH BARB ELBOW: RAIN BIRD MODEL SBE -050 3) CONTRACTOR SHALL OBTAIN ANY REQUIRED PERMITS, ADHERE TO ALL MUNICIPAL CODES AND FOLLOW STANDARD AND ACCEPTED LOCAL PRACTICES. PVC SCH 40 TEE OR ELL 4) AN AUTOMATIC DRAIN VALVE SHALL BE INSTALLED AT THE LOWEST PORTION OF EACH PVC LATERAL PIPE ZONE AND AT 100' INTERVALS ON THE MAINLINE (SEE DETAIL). BARB E MALE NPT x.490 BIRD CH 5) VALVE WIRING SHALL BE 14 GAUGE SINGLE STRAND COPPER DIRECT BURIAL BARB ELBOW: RAIN BIRD MODEL SBE -050 IRRIGATION WIRE. PROVIDE (1) ONE WHITE WIRE AS THE COMMON FOR ALL THE VALVES. PROVIDE (1) ONE NON-WHITE WIRE FOR EACH OF THE ZONE VALVES. ALSO PROVIDE (1) ON NON-WHITE WIRE FOR ALL THE VALVES TO BE USED AS A SPARE. ALL SPLICES SHALL BE WATERPROOF AND PLACED AT VALVE LOCATIONS ONLY. 1) AUTOMATIC RAIN SHUTOFF �4) QUICK -COUPLING VALVE L7) REMOTE CONTROL VALVE (10) POP-UP SPRAY HEAD SHRUB AREAS � OUTSIDE WALL HYBRID CONTROLLER: RAIN BIRD ESP -LX SERIES OUTDOOR WALL MOUNT 1 -5 -INCH PVC, SCH 40 CONDUIT AND FITTINGS JUNCTION BOX WIRES TO REMOTE. CONTROL VALVES 1 -INCH PVC SCH 40 CONDUIT AND FITTINGS TO POWER SUPPLY SECTION VIEW MAINLINE, LATERAL, MAINLINE LATERAL WIRING IN AND WIRING IN PIPE PIPE CONDUIT THE SAME TRENCH PLAN VIEW WIRE W/0 CONDUIT RUN WIRING BENEATH ALL SOLVENT WELD TIE A 24 -INCH LOOP IN AND BESIDE MAINLINE. PLASTIC PIPING TO ALL WIRING AT CHANGES TAPE AND BUNDLE AT BE SNAKED IN OF DIRECTION OF 30" 10 -FOOT INTERVALS. TRENCH AS SHOWN. OR GREATER. UNTIE PVC SCH 40 TEE OR ELL AFTER ALL CONNECTIONS NOTES: HAVE BEEN MADE. 1. SLEEVE BELOW ALL HARDSCAPE ELEMENTS WITH CLASS 200 PVC TWICE THE DIAMETER OF THE PIPE OR WIRE BUNDLE WITHIN. 2. FOR PIPE AND WIRE BURIAL DEPTHS SEE SPECIFICATIONS. FINISH GRADE — -' COMPACTED BACKFILL LATERAL PVC LINE y-- 4" SAND AROUND ALL PIPE MAIN PVC LINE. TAPE WIRES TO BOTTOM \•••.. SIDE OF MAIN LINE AT 10'-0" O.C. 61 ALL PIPING SHALL BE CLASS 200 SDR 21 PVC. ALL FITTINGS SHALL BE SCH. 40 TYPE 1. USE A PVC SOLVENT AND PRIMER AS RECOMMENDED/APPROVED BY THE PIPE MANUFACTURER. ALL MATERIAL AND EQUIPMENT SHALL BE OF DOMESTIC MANUFACTURER 7) PLACE ALL PIPING ON THE PERIMETER OF LANDSCAPE AREAS WHERE POSSIBLE. PLACE I GRADE VALVES IN PLANTING AREAS WHERE POSSIBLE. LIMIT TRENCHING AROUND EXISTING POP-UP SPRINKLER: TREES AS MUCH AS POSSIBLE. BE AWARE OF THE LOCATION OF NEW TREES AND SHRUBS BIRD 'L -PC AND PLACE PIPING AWAY FROM THE ROOT BALLS 1180 NIPPLE GTH AS REQUIRED) ASSEMBLY: 3IRD L SA -127575 IH 40 TEE OR ELL LTERAL PIPE [ 2) HYBRID CONTROLLER 5) PIPE & WIRE TRENCHING ( S) TRENCH SECTION (11)ROTOR POP-UP SPRINKLER TURF AREAS BRASS NIPPLES BRONZE Y -STRAINER HEATED AND INSULATED ENCLOSURE COPPER RISER PIPE G ATE VALVE IN VALVE BOX FROM METER 4' COPPER NIPPLE WILKINS 975XL BACKFLOW PREVENTER BRASS TEE 3/4" BRASS HOSE BIB e COPPER UNIONS RED. BUSHING (if required.) INSTALLI2"ABOVE FINISH GRADE MIN.PVC MAINLINE NOTES: 1. PROVIDE BACKFLOW COVER WITH INTEGRATED HEATING SYSTEM. 2. COORDINATE ELECTRICAL SUPPLY FOR COVER WITH GENERAL CONTRACTOR. —IIS" MIN.F— PAVING NOTES: I. ALL PVC IRRIGATION SLEEVES TO BE SCHEDULE 40 PIPE. 2. ALL JOINTS TO BE SOLVENT WELDED AND WATERTIGHT. 3. WHERE THERE IS MORE THAN ONE SLEEVE, EXTEND THE SMALLER SLEEVE TO 24 -INCHES MINIMUM ABOVE FINISH GRADE. 4. MECHANICALLY TAMP TO 95% PROCTOR. SLEEVING NOTES 1/2 -INCH MALE NPT x.490 INCH U ALL SLEEVING FOR THE IRRIGATION SYSTEM SHALL BE INSTALLED BY THE GENERAL CONTRACTOR. 'INISH GRADE/TOP OF MULCH 2) SLEEVING SHALL BE W SCH. 40 PVC INSTALLED A MINIMUM OF 18" AND A MAXIMUM OF 24" BELOW THE MODEL SBE -050 FINISHED GRADE, ENDS OF THE SLEEVES SHALL EXTEND 12" PAST ALL HARDSCAPE AREAS AND BE SWING PIPE, 12 -INCH LENGTH: CLEARLY MARKED FOR THE FUTURE USE OF IRRIGATION CONTRACTOR. 'OP -UP SPRAY SPRINKLER: POWER SOURCE TO CONTROLLER AND CONTROLLER TO BELOW GROUND FOR VALVE CONTROL WIRING. RAIN BIRD 1806 SAM -PRS W/ VAN NOZZLE CONTROLLER 1/2 -INCH MALE NPT x.490 INCH RAIN BIRD ESP LX PLUS SERIES CONTROLLER FOR ELECTRIC VALVE SYSTEMS WITH LOCKING CABINET, BARB ELBOW: RAIN BIRD MASTER VALVE CIRCUIT AND INTERNAL TRANSFORMER. PROVIDE HARDWIRED ELECTRICAL POWER MODEL SBE -050 SOURCE FROM BUILDING SYSTEM AND COORDINATE CABINET MOUNTING LOCATION WITH OTHER SWING PIPE, 12 -INCH LENGTH: ELECTRICAL PANELS AND GROUNDING. PROVIDE RIGID METAL CONDUIT TO ENCASE ALL WIRING FROM RAIN BIRD MODEL SP -100 POWER SOURCE TO CONTROLLER AND CONTROLLER TO BELOW GROUND FOR VALVE CONTROL WIRING. PAINT EXPOSED CONDUIT TO MATCH BUILDING EXTERIOR. PVC SCH 40 TEE OR ELL BACKFLOW PREVENTER ASSEMBLY 1/2 -INCH MALE NPT x.490 INCH PROVIDE ONE WILKENSiZURN MODEL 975XL REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER BARB ELBOW: RAIN BIRD MODEL SBE -050 WITH MANUAL GATE VALVE. INSTALL AT MINIMUM HEIGHT ABOVE FINISHED GRADE PER LOCAL PLUMBING CODE REQUIREMENTS. INSTALL WITH UNIONS FOR WINTER DISCONNECT AND USE CLOSE PVC LATERAL PIPE FITTINGS TO MINIMIZE TOTAL LENGTH OF UNIT. RAIN SENSOR [ 3) BACKFLOW PREVENTER 6) SLEEVING K 9) POP-UP SPRAY HEAD TURF AREAS PROVIDE AND INSTALL ONE HUNTER "MINI-CLIK" FOR SUSPENSION OF WATERING PROGRAM DURING RAINFALL. PROVIDE RIGID METAL CONDUIT AND ENCASE ALL EXPOSED WIRING FROM UNIT TO CONTROLLER. PAINT EXPOSED CONDUIT TO MATCH BUILDING EXTERIOR. 8) PROVIDE FOR WINTERIZATION USING THE BLOW OUT METHOD 9) COORDINATE LOCATION OF THE CONTROL BOX AND RAIN SENSOR WITH THE OWNER AND/OR ARCHITECT. 10) PROVIDE 100 % COVERAGE FOR ALL LANDSCAPE AREAS AND MAKE FINAL ADJUSTMENTS TO OBTAIN OPTIMAL PERFORMANCE. 100 % COVERAGE WILL BE DEFINED AS HAVING HEAD TO HEAD COVERAGE IN ALL DIRECTIONS AND IN ALL AREAS. THERE SHALL BE NO SHRUB HEADS PLACED ON THE SAME ZONE WITH TURF HEADS. THERE SHALL BE NO TURF HEADS PLACED ON THE SAME ZONE WITH SHRUB HEADS. 11) CONTRACTOR TO PROVIDE SERVICE TAP, LINE AND METER FOR IRRIGATION SYSTEM SERVICE. 12) COMPACT BACK FILL IN ALL TRENCHES TO STANDARD SUB GRADE COMPACT ION REQUIREMENTS GIVEN IN SITE GRADING SPECIFICATIONS. 13) CONTRACTOR IS RESPONSIBLE FOR SIZING ALL WIRING TO CONTROL VALVES. DIRECT BURIAL QUALITY WIRE WITH SEALED WATERPROOF CONNECTORS REQUIRED. 14) INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS DETAILS AND SPECIFICATIONS. 17) WHEN TRENCHING UNDER THE DRIPLINE OF EXISTING TREES EXTREME CARE MUST BE GIVEN TO AVOID ROOT DAMAGE. IF AT ALL POSSIBLE AVOID TRENCHING INSIDE THE DRIPLINE BY GOING AROUND THE TREE RATHER THAM UNDER IT. IF TRENCHING MUST OCCUR UNDER THE DRIPLINE, USE EITHER TUNNELING OR HAND -DIGGING METHODS RATHER THAN A MECHANICALTRENCHER. MINIMIZE THE IMPACTS OF ROOT SEVERING BY AVOIDING CONSTRUCTION DURING HOT, DRY WEATHER, KEEPING TREES WELL WATERED BEFORE AND AFTER DIGGING AND COVERING ROOTS WITH SOIL OR MULCH AS SOON AS POSSIBLE. NOTE: SEE THE LANDSCAPE, DIMENSIONING, AND GRADING PLANS FOR LOCATION OF WALKS, LIGHTS, WALLS AND OTHER FEATURES THAT MAY IMPACT THE INSTALLATION OF THE IRRIGATION SYSTEM. IRRIGATION DETAILS ,<-�EFORE Yo ARKANSAS STATE LAW REQUIRES THAT THE EXCAVATOR IS TO LOCATE ALL EXISTING UTILITIES IN ACCORDANCE WITH THE ARKANSAS UNDERGROUND FACILITIES DAMAGE PREVENTION ACT. THIS LAW REQUIRES THAT THE EXCAVATOR MAKE A TELEPHONE CALL TO THE ARKANSAS ONE CALL SYSTEM AT 1-800-482-8998 AT LEAST TWO WORKING DAYS PRIOR TO EXCAVATION TO INSURE THAT ANY EXISTING UTILITIES CAN BE LOCATED. Seal Drawing Type IRRIGATION DETAILS Project No. R`a/�. L A N D 5C, A P E A FZ G R I T E G T S ROBERTS Voll LL I AMS A550 C. I ATES 1501 N. UNIVERSITY SUITE 430 LITTLE ROCK, AR 92207 (501) 2a0-0123 SHEET L 3