HomeMy WebLinkAboutZ-5781-A Map 11EXTERIOR WALL
RAIN SENSOR
FREEZE SENSOI
NOTE:
I. FOR COMPLETE INSTALLATION
WITIi RAIN SENSOR
SENSOR
WIRING CONDUIT
SEE INSTRUCTIONS ENCLOSED
FINISH GRADE/TOP OF MULCH
QUICK -COUPLING VALVE:
RAIN BIRD MODEL 5RC
VALVE BOX WITH COVER:
6 -INCH SIZE
3 -INCH MINIMUM DEPTH OF
3/4 -INCH WASHED GRAVEL
PVC SCH 80 NIPPLE
(LENGTH AS REQUIRED)
BRICK (1 OF 2)
PVC SCH 80 NIPPLE
(LENGTH AS REQUIRED)
PVC SCH 40 STREET ELL
PVC SCH 40 TEE OR ELL
f
PVC MAINLINE PIPE
--PVC SCH 40 ELL
PVC SCH 40 STREET ELL
2" x 2" REDWOOD STAKE W/
STAINLESS STEEL GEAR
CLAMPS OR EQUIVALENT
NOTE: SUPPORTSYSTEM
I. FURNISH FITTINGS .AND PIPING NOMINALLY SIZED IDENTICAL TO
NOMINAL QUICK COUPLING VALVE INLET SIZE.
ISMOUIrAIWIN2I AID
PVC SCH 40 TEE OR ELL
PVC SCH 40 MALE ADAPTER
PVC LATERAL PIPE
3.0 -INCH MINIMUM DEPTH OF
3/4 -INCH WASHED GRAVEL
PLANT MATERIAL
FINISH GRADE/TOP OF MULCH
POP-UP SPRAY SPRINKLER:
RAIN BIRD 1812 SAM -PRS
W/ VAN NOZZLE
SWING PIPE, 12 -INCH LENGTH:
RAIN BIRD MODEL SP -100
1/2 -INCH MALE NPT x.490 INCH
BARB ELBOW: RAIN BIRD
MODEL SBE -050
PVC SCH 40 TEE OR ELL
PVC LATERAL PIPE
1/2 -INCH MALE NPT x.490 INCH
BARB ELBOW: RAIN BIRD
MODEL SBE -050
K 1) AUTOMATIC RAIN SHUTOFF �4) QUICK -COUPLING VALVE L7) REMOTE CONTROL VALVE k10) POP-UP SPRAY HEAD SHRUB AREAS
1 SECTION VIEW
OUTSIDE WALK MAINLINE, LATERAL, MAINLINE LATERAL WIRING IN
AND WIRING IN PIPE PIPE CONDUIT FINISH GRADE FINISH GRADE
/1 THE SAME TRENCH
ROTOR POP-UP SPRINKLER:
RAIN BIRD
O wo 5006 -PL -PC
HYBRID CONTROLLER: •� "-`""-""""""`-' COMPACTED BACKFILL
G RAIN BIRD ESP -LX SERIES
OUTDOOR WALL MOUNT �,.I LATERAL PVC LINE
I
PLAN VIEW PVC SCH 80 NIPPLE
WIRE W10 CONDUIT (LENGTH AS REQUIRED)
7.
• """ 4" SAND
AROUND ALL PIPE
• 1.5 -INCH PVC SCH 40 CONDUIT MAIN PVC LINE. TAPE SWING ASSEMBLY:
RAIN BIRD
AND FITTINGS \ . -., WIRES TO BOTTOM MODEL SA -127575
JUNCTION BOX RUN WIRING BENEATH ALL SOLVENT WELD TIE A 24 -INCH LOOP IN \ '•`•':` _ SIDE OF MAIN LINE PVC SCH 40 TEE OR ELL
AND BESIDE MAINLINE. PLASTIC PIPING TO ALL WIRING AT CHANGES AT 10'-0" O.C.
TAPE AND BUNDLE AT BE SNAKED IN OF DIRECTION OF 30°
10TOOT INTERVALS. TRENCH AS SHOWN. OR GREATER. UNTIE
AFTER ALL CONNECTIONS
WIRES TO REMOTE CONTROL NOTES: HAVE BEEN MADE.
VALVES
1. SLEEVE BELOW ALL HARDSCAPE ELEMENTS WITH CLASS 200 PVC TWICE THE
1 -INCH PVC SCH 40 CONDUIT DIAMETER OF THE PIPE OR WERE BUNDLE WITHIN.
AND FITTINGS TO POWER SUPPLY 2. FOR PIPE AND WIRE BURIAL DEPTHS SEE SPECIFICATIONS.
S. PVC LATERAL PIPE
2 HYBRID CONTROLLER 5 PIPE & WIRE TRENCHING 8 TRENCH SECTION 11 ROTOR POP-UP SPRINKLER TURF AREAS
BRASS NIPPLES
BRONZE Y -STRAINER
HEATED AND INSULATED
ENCLOSURE
COPPER RISER PIPE
GATE VALVE IN
VALVE BOX
FROM
METER
,'COPPER
NIPPLE
• WILKINS 975XL BACKFLOW PREVENTER
BRASS TEE
_ 3/4" BRASS
HOSE BIB
COPPER UNIONS
INSTALL 12" ABOVE
FINISH GRADE MIN.
RED. BUSHING
(if required.)
PVC MAINLINE
NOTES:
1. PROVIDE BACKFLOW COVER WITH INTEGRATED HEATING SYSTEM.
2. COORDINATE ELECTRICAL SUPPLY FOR COVER WITH GENERAL CONTRACTOR.
-PAVING
DITCH
SLEEVES
CAP (TYPICAL)
18" MIN, F_
24" MIN. TO
FINISH GRADE
18" 'MIN.
24",MAX.
NOTES:
1. ALL PVC IRRIGATION SLEEVES TO BE SCHEDULE 40 PIPE.
2. ALL JOINTS TO BE SOLVENT WELDED AND WATERTIGHT.
3. WHERE THERE IS MORE THAN ONE SLEEVE, EXTEND THE SMALLER SLEEVE
TO 24 -INCHES MINIMUM ABOVE FINISH GRADE.
4. MECHANICALLY TAMP TO 95%PROCTOR.
FINISH GRADE/TOP OF MULCH
POP-UP SPRAY SPRINKLER:
RAIN BIRD 1806 SAM -PRS
W/ VAN NOZZLE
1/2 -INCH MALE NPT x.490 INCH
BARB ELBOW: RAIN BIRD
MODEL SBE -050
SWING PIPE, 12 -INCH LENGTH:
RAIN BIRD MODEL SP -100
PVC SCH 40 TEE OR ELL
1/2 -INCH MALE NET x.490 INCH
BARB ELBOW: RAIN BIRD
MODEL SBE -050
PVC LATERAL PIPE
C 3) BACKFLOW PREVENTER ( 6) SLEEVING K 9) POP-UP SPRAY HEAD TURF AREAS
SLEEVING NOTES
1) ALL SLEEVING FOR THE IRRIGATION SYSTEM SHALL BE INSTALLED BY THE GENERAL CONTRACTOR
2) SLEEVING SHALL BE 6" SCH. 40 PVC INSTALLED A MINIMUM OF 18" AND AMAXIMUM OF 24" BELOW THE
FINISHED GRADE. ENDS OF THE SLEEVES SHALL EXTEND 12" PAST ALL HARDSCAPE AREAS AND BE
CLEARLY MARKED FOR THE FUTURE USE OF IRRIGATION CONTRACTOR.
CONTROLLER
RAIN BIRD ESPLXPLUS SERIES CONTROLLER FOR ELECTRIC VALVE SYSTEMS WITH LOCKING CABINET,
MASTER VALVE CIRCUIT AND INTERNAL TRANSFORMER. PROVIDE HARDWIRED ELECTRICAL POWER
SOURCE FROM BUILDING SYSTEM AND COORDINATE CABINET MOUNTING LOCATION WITH OTHER
ELECTRICAL PANELS AND GROUNDING. PROVIDE RIGID METAL CONDUIT TO ENCASE ALL WIRING FROM
POWER SOURCE TO CONTROLLER AND CONTROLLER TO BELOW GROUND FOR VALVE CONTROL WIRING.
PAINT EXPOSED CONDUIT TO MATCH BUILDING EXTERIOR.
BACKFLOW PREVENTER ASSEMBLY
PROVIDE ONE WILKENS/ZURN MODEL 975XL REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER
WITH MANUAL GATE VALVE. INSTALL AT MINIMUM HEIGHT ABOVE FINISHED GRADE PER LOCAL
PLUMBING CODE REQUIREMENTS. INSTALL WITH UNIONS FOR WINTER DISCONNECT AND USE CLOSE
FITTINGS TO MINIMIZE TOTAL LENGTH OF UNIT.
RAIN SENSOR
PROVIDE AND INSTALL ONE HUNTER "MINI-CLIK" FOR SUSPENSION OF WATERING PROGRAM DURING
RAINFALL. PROVIDE RIGID METAL CONDUIT AND ENCASE ALL EXPOSED WIRING FROM UNIT TO
CONTROLLER PAINT EXPOSED CONDUIT TO MATCH BUILDING EXTERIOR
IRRIGATION NOTES
1) LOCATE HEADS, LINES AND WIRING ALONG BACK OF CURBS AND BED EDGES.
COMBINE LINES AND WIRING IN COMMON TRENCHES WHERE POSSIBLE. PLACE HEADS
DIRECTLY ADJACENT TO CURBS AND EDGES. PLACE VALVES IN ACCESSIBLE LOCATIONS.
NO LINES ARE TO BE PLACED UNDER VEHICULAR PAVING AREAS UNLESS IN IRRIGATION
SLEEVES.
2) CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ALL UTILITIES DURING THE
INSTALLATION. CONTRACTOR SHALL SEEK ASSISTANCE FROM THE LOCAL UTILITIES IN
THE LOCATION OF THE UTILITIES PRIOR TO EXCAVATION.
3) CONTRACTOR SHALL OBTAIN ANY REQUIRED PERMITS, ADHERE TO ALL MUNICIPAL
CODES AND FOLLOW STANDARD AND ACCEPTED LOCAL PRACTICES.
4) AN AUTOMATIC DRAIN VALVE SHALL BE INSTALLED AT THE LOWEST PORTION OF EACH
ZONE AND AT 100' INTERVALS ON THE MAINLINE (SEE DETAIL).
5) VALVE WIRING SHALL BE 14 GAUGE SINGLE STRAND COPPER DIRECT BURIAL
IRRIGATION WIRE. PROVIDE (1) ONE WHITE WIRE AS THE COMMON FOR ALL THE VALVES.
PROVIDE (1) ONE NON-WHITE WIRE FOR EACH OF THE ZONE VALVES. ALSO PROVIDE (1) ON
NON-WHITE WIRE FOR ALL THE VALVES TO BE USED AS A SPARE. ALL SPLICES SHALL BE
WATERPROOF AND PLACED AT VALVE LOCATIONS ONLY.
6) ALL PIPING SHALL BE CLASS 200 SDR 21 PVC. ALL FITTINGS SHALL BE SCH. 40 TYPE 1.
USE A PVC SOLVENT AND PRIMER AS RECOMMENDEDIAPPROVED BY THE PIPE
MANUFACTURER. ALL MATERIAL AND EQUIPMENT SHALL BE OF DOMESTIC
MANUFACTURER
7) PLACE ALL PIPING ON THE PERIMETER OF LANDSCAPE AREAS WHERE POSSIBLE. PLACE
VALVES IN PLANTING AREAS WHERE POSSIBLE. LIMIT TRENCHING AROUND EXISTING
TREES AS MUCH AS POSSIBLE. BE AWARE OF THE LOCATION OF NEW TREES AND SHRUBS
AND PLACE PIPING AWAY FROM THE ROOT BALLS.
8) PROVIDE FOR WINTERIZATION USING THE BLOW OUT METHOD.
9) COORDINATE LOCATION OF THE CONTROL BOX AND RAIN SENSOR WITH THE OWNER
AND/OR ARCHITECT.
10) PROVIDE 100 % COVERAGE FOR ALL LANDSCAPE AREAS AND MAKE FINAL
ADJUSTMENTS TO OBTAIN OPTIMAL PERFORMANCE. 100 % COVERAGE WILL BE
DEFINED AS HAVING HEAD TO HEAD COVERAGE IN ALL DIRECTIONS AND IN ALL
AREAS. THERE SHALL BE NO SHRUB HEADS PLACED ON THE SAME ZONE WITH TURF
HEADS. THERE SHALL BE NO TURF HEADS PLACED ON THE SAME ZONE WITH SHRUB
HEADS.
11) CONTRACTOR TO PROVIDE SERVICE TAP, LINE AND METER FOR IRRIGATION SYSTEM
SERVICE.
12) COMPACT BACK FILL IN ALL TRENCHES TO STANDARD SUB GRADE COMPACT ION
REQUIREMENTS GIVEN IN SITE GRADING SPECIFICATIONS.
13) CONTRACTOR IS RESPONSIBLE FOR SIZING ALL WIRING TO CONTROL VALVES. DIRECT
BURIAL QUALITY WIRE WITH SEALED WATERPROOF CONNECTORS REQUIRED.
14) INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS DETAILS AND
SPECIFICATIONS.
17) WHEN TRENCHING UNDER THE DRIPLINE OF EXISTING TREES EXTREME CARE MUST
BE GIVEN TO AVOID ROOT DAMAGE. IF AT ALL POSSIBLE AVOID TRENCHING INSIDE THE
DRIPLINE BY GOING AROUND THE TREE RATHER THAN UNDER IT. IF TRENCHING MUST
OCCUR UNDER THE DRIPLINE, USE EITHER TUNNELING OR HAND -DIGGING METHODS
RATHER THAN A MECHANICALTRENCHER. MINIMIZE THE IMPACTS OF ROOT SEVERING BY
AVOIDING CONSTRUCTION DURING HOT, DRY WEATHER, KEEPING TREES WELL WATERED
BEFORE AND AFTER DIGGING AND COVERING ROOTS WITH SOIL OR MULCH AS SOON AS
POSSIBLE.
NOTE:
SEE THE LANDSCAPE, DIMENSIONING, AND GRADING PLANS FOR
LOCATION OF WALKS, LIGHTS, WALLS AND OTHER FEATURES THAT
MAY IMPACT THE INSTALLATION OF THE IRRIGATION SYSTEM.
IRRIGATION DETAILS
P�EFORE yy
ARKANSAS STATE LAW REQUIRES THAT THE EXCAVATOR
IS TO LOCATE ALL EXISTING UTILITIES IN ACCORDANCE
WITH THE ARKANSAS UNDERGROUND FACILITIES DAMAGE
PREVENTION ACT. THIS LAW REQUIRES THAT THE EXCAVATOR
MAKE A TELEPHONE CALL TO THE ARKANSAS ONE CALL
SYSTEM AT 1-800-482-8995 AT LEAST TWO WORKING
DAYS PRIOR TO EXCAVATION TO INSURE THAT ANY EXISTING,
UTILITIES CAN BE LOCATED.
Seal
Drawing Type
IRRIGATION
DETAILS
Project No.
Date
09/19/06
Revisions
L A N D S G A P H
A FZ G H 1 T H G T S
ROBERT5 $
WILLIAM5
A550G I A7E5
1501 N. UNIVERSITY SUITE 430
LITTLE ROCK, AR 92207
(501) 2a0-0123
SHEET L3
30 -INCH LINEAR LENGTH OF WIRE,
COILED
WATER PROOF CONNECTION
(1 OF 2)
ID TAG
VALVE BOX WITH COVER:
I2 -INCH SIZE
FINISH GRADE/TOP OF MULCH
REMOTE CONTROL VALVE:
RAIN BIRD PEB
N'
PVC SCH 80 NIPPLE (CLOSE)
PVC SCH 40 ELL
PVC SCH 80 NIPPLE
(LENGTH AS REQUIRED)
�
BRICK (1 OF 4)
SCH 80 NIPPLE (2 -INCH LENGTH,
HIDDEN) AND SCH 40 ELL
ISMOUIrAIWIN2I AID
PVC SCH 40 TEE OR ELL
PVC SCH 40 MALE ADAPTER
PVC LATERAL PIPE
3.0 -INCH MINIMUM DEPTH OF
3/4 -INCH WASHED GRAVEL
PLANT MATERIAL
FINISH GRADE/TOP OF MULCH
POP-UP SPRAY SPRINKLER:
RAIN BIRD 1812 SAM -PRS
W/ VAN NOZZLE
SWING PIPE, 12 -INCH LENGTH:
RAIN BIRD MODEL SP -100
1/2 -INCH MALE NPT x.490 INCH
BARB ELBOW: RAIN BIRD
MODEL SBE -050
PVC SCH 40 TEE OR ELL
PVC LATERAL PIPE
1/2 -INCH MALE NPT x.490 INCH
BARB ELBOW: RAIN BIRD
MODEL SBE -050
K 1) AUTOMATIC RAIN SHUTOFF �4) QUICK -COUPLING VALVE L7) REMOTE CONTROL VALVE k10) POP-UP SPRAY HEAD SHRUB AREAS
1 SECTION VIEW
OUTSIDE WALK MAINLINE, LATERAL, MAINLINE LATERAL WIRING IN
AND WIRING IN PIPE PIPE CONDUIT FINISH GRADE FINISH GRADE
/1 THE SAME TRENCH
ROTOR POP-UP SPRINKLER:
RAIN BIRD
O wo 5006 -PL -PC
HYBRID CONTROLLER: •� "-`""-""""""`-' COMPACTED BACKFILL
G RAIN BIRD ESP -LX SERIES
OUTDOOR WALL MOUNT �,.I LATERAL PVC LINE
I
PLAN VIEW PVC SCH 80 NIPPLE
WIRE W10 CONDUIT (LENGTH AS REQUIRED)
7.
• """ 4" SAND
AROUND ALL PIPE
• 1.5 -INCH PVC SCH 40 CONDUIT MAIN PVC LINE. TAPE SWING ASSEMBLY:
RAIN BIRD
AND FITTINGS \ . -., WIRES TO BOTTOM MODEL SA -127575
JUNCTION BOX RUN WIRING BENEATH ALL SOLVENT WELD TIE A 24 -INCH LOOP IN \ '•`•':` _ SIDE OF MAIN LINE PVC SCH 40 TEE OR ELL
AND BESIDE MAINLINE. PLASTIC PIPING TO ALL WIRING AT CHANGES AT 10'-0" O.C.
TAPE AND BUNDLE AT BE SNAKED IN OF DIRECTION OF 30°
10TOOT INTERVALS. TRENCH AS SHOWN. OR GREATER. UNTIE
AFTER ALL CONNECTIONS
WIRES TO REMOTE CONTROL NOTES: HAVE BEEN MADE.
VALVES
1. SLEEVE BELOW ALL HARDSCAPE ELEMENTS WITH CLASS 200 PVC TWICE THE
1 -INCH PVC SCH 40 CONDUIT DIAMETER OF THE PIPE OR WERE BUNDLE WITHIN.
AND FITTINGS TO POWER SUPPLY 2. FOR PIPE AND WIRE BURIAL DEPTHS SEE SPECIFICATIONS.
S. PVC LATERAL PIPE
2 HYBRID CONTROLLER 5 PIPE & WIRE TRENCHING 8 TRENCH SECTION 11 ROTOR POP-UP SPRINKLER TURF AREAS
BRASS NIPPLES
BRONZE Y -STRAINER
HEATED AND INSULATED
ENCLOSURE
COPPER RISER PIPE
GATE VALVE IN
VALVE BOX
FROM
METER
,'COPPER
NIPPLE
• WILKINS 975XL BACKFLOW PREVENTER
BRASS TEE
_ 3/4" BRASS
HOSE BIB
COPPER UNIONS
INSTALL 12" ABOVE
FINISH GRADE MIN.
RED. BUSHING
(if required.)
PVC MAINLINE
NOTES:
1. PROVIDE BACKFLOW COVER WITH INTEGRATED HEATING SYSTEM.
2. COORDINATE ELECTRICAL SUPPLY FOR COVER WITH GENERAL CONTRACTOR.
-PAVING
DITCH
SLEEVES
CAP (TYPICAL)
18" MIN, F_
24" MIN. TO
FINISH GRADE
18" 'MIN.
24",MAX.
NOTES:
1. ALL PVC IRRIGATION SLEEVES TO BE SCHEDULE 40 PIPE.
2. ALL JOINTS TO BE SOLVENT WELDED AND WATERTIGHT.
3. WHERE THERE IS MORE THAN ONE SLEEVE, EXTEND THE SMALLER SLEEVE
TO 24 -INCHES MINIMUM ABOVE FINISH GRADE.
4. MECHANICALLY TAMP TO 95%PROCTOR.
FINISH GRADE/TOP OF MULCH
POP-UP SPRAY SPRINKLER:
RAIN BIRD 1806 SAM -PRS
W/ VAN NOZZLE
1/2 -INCH MALE NPT x.490 INCH
BARB ELBOW: RAIN BIRD
MODEL SBE -050
SWING PIPE, 12 -INCH LENGTH:
RAIN BIRD MODEL SP -100
PVC SCH 40 TEE OR ELL
1/2 -INCH MALE NET x.490 INCH
BARB ELBOW: RAIN BIRD
MODEL SBE -050
PVC LATERAL PIPE
C 3) BACKFLOW PREVENTER ( 6) SLEEVING K 9) POP-UP SPRAY HEAD TURF AREAS
SLEEVING NOTES
1) ALL SLEEVING FOR THE IRRIGATION SYSTEM SHALL BE INSTALLED BY THE GENERAL CONTRACTOR
2) SLEEVING SHALL BE 6" SCH. 40 PVC INSTALLED A MINIMUM OF 18" AND AMAXIMUM OF 24" BELOW THE
FINISHED GRADE. ENDS OF THE SLEEVES SHALL EXTEND 12" PAST ALL HARDSCAPE AREAS AND BE
CLEARLY MARKED FOR THE FUTURE USE OF IRRIGATION CONTRACTOR.
CONTROLLER
RAIN BIRD ESPLXPLUS SERIES CONTROLLER FOR ELECTRIC VALVE SYSTEMS WITH LOCKING CABINET,
MASTER VALVE CIRCUIT AND INTERNAL TRANSFORMER. PROVIDE HARDWIRED ELECTRICAL POWER
SOURCE FROM BUILDING SYSTEM AND COORDINATE CABINET MOUNTING LOCATION WITH OTHER
ELECTRICAL PANELS AND GROUNDING. PROVIDE RIGID METAL CONDUIT TO ENCASE ALL WIRING FROM
POWER SOURCE TO CONTROLLER AND CONTROLLER TO BELOW GROUND FOR VALVE CONTROL WIRING.
PAINT EXPOSED CONDUIT TO MATCH BUILDING EXTERIOR.
BACKFLOW PREVENTER ASSEMBLY
PROVIDE ONE WILKENS/ZURN MODEL 975XL REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER
WITH MANUAL GATE VALVE. INSTALL AT MINIMUM HEIGHT ABOVE FINISHED GRADE PER LOCAL
PLUMBING CODE REQUIREMENTS. INSTALL WITH UNIONS FOR WINTER DISCONNECT AND USE CLOSE
FITTINGS TO MINIMIZE TOTAL LENGTH OF UNIT.
RAIN SENSOR
PROVIDE AND INSTALL ONE HUNTER "MINI-CLIK" FOR SUSPENSION OF WATERING PROGRAM DURING
RAINFALL. PROVIDE RIGID METAL CONDUIT AND ENCASE ALL EXPOSED WIRING FROM UNIT TO
CONTROLLER PAINT EXPOSED CONDUIT TO MATCH BUILDING EXTERIOR
IRRIGATION NOTES
1) LOCATE HEADS, LINES AND WIRING ALONG BACK OF CURBS AND BED EDGES.
COMBINE LINES AND WIRING IN COMMON TRENCHES WHERE POSSIBLE. PLACE HEADS
DIRECTLY ADJACENT TO CURBS AND EDGES. PLACE VALVES IN ACCESSIBLE LOCATIONS.
NO LINES ARE TO BE PLACED UNDER VEHICULAR PAVING AREAS UNLESS IN IRRIGATION
SLEEVES.
2) CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ALL UTILITIES DURING THE
INSTALLATION. CONTRACTOR SHALL SEEK ASSISTANCE FROM THE LOCAL UTILITIES IN
THE LOCATION OF THE UTILITIES PRIOR TO EXCAVATION.
3) CONTRACTOR SHALL OBTAIN ANY REQUIRED PERMITS, ADHERE TO ALL MUNICIPAL
CODES AND FOLLOW STANDARD AND ACCEPTED LOCAL PRACTICES.
4) AN AUTOMATIC DRAIN VALVE SHALL BE INSTALLED AT THE LOWEST PORTION OF EACH
ZONE AND AT 100' INTERVALS ON THE MAINLINE (SEE DETAIL).
5) VALVE WIRING SHALL BE 14 GAUGE SINGLE STRAND COPPER DIRECT BURIAL
IRRIGATION WIRE. PROVIDE (1) ONE WHITE WIRE AS THE COMMON FOR ALL THE VALVES.
PROVIDE (1) ONE NON-WHITE WIRE FOR EACH OF THE ZONE VALVES. ALSO PROVIDE (1) ON
NON-WHITE WIRE FOR ALL THE VALVES TO BE USED AS A SPARE. ALL SPLICES SHALL BE
WATERPROOF AND PLACED AT VALVE LOCATIONS ONLY.
6) ALL PIPING SHALL BE CLASS 200 SDR 21 PVC. ALL FITTINGS SHALL BE SCH. 40 TYPE 1.
USE A PVC SOLVENT AND PRIMER AS RECOMMENDEDIAPPROVED BY THE PIPE
MANUFACTURER. ALL MATERIAL AND EQUIPMENT SHALL BE OF DOMESTIC
MANUFACTURER
7) PLACE ALL PIPING ON THE PERIMETER OF LANDSCAPE AREAS WHERE POSSIBLE. PLACE
VALVES IN PLANTING AREAS WHERE POSSIBLE. LIMIT TRENCHING AROUND EXISTING
TREES AS MUCH AS POSSIBLE. BE AWARE OF THE LOCATION OF NEW TREES AND SHRUBS
AND PLACE PIPING AWAY FROM THE ROOT BALLS.
8) PROVIDE FOR WINTERIZATION USING THE BLOW OUT METHOD.
9) COORDINATE LOCATION OF THE CONTROL BOX AND RAIN SENSOR WITH THE OWNER
AND/OR ARCHITECT.
10) PROVIDE 100 % COVERAGE FOR ALL LANDSCAPE AREAS AND MAKE FINAL
ADJUSTMENTS TO OBTAIN OPTIMAL PERFORMANCE. 100 % COVERAGE WILL BE
DEFINED AS HAVING HEAD TO HEAD COVERAGE IN ALL DIRECTIONS AND IN ALL
AREAS. THERE SHALL BE NO SHRUB HEADS PLACED ON THE SAME ZONE WITH TURF
HEADS. THERE SHALL BE NO TURF HEADS PLACED ON THE SAME ZONE WITH SHRUB
HEADS.
11) CONTRACTOR TO PROVIDE SERVICE TAP, LINE AND METER FOR IRRIGATION SYSTEM
SERVICE.
12) COMPACT BACK FILL IN ALL TRENCHES TO STANDARD SUB GRADE COMPACT ION
REQUIREMENTS GIVEN IN SITE GRADING SPECIFICATIONS.
13) CONTRACTOR IS RESPONSIBLE FOR SIZING ALL WIRING TO CONTROL VALVES. DIRECT
BURIAL QUALITY WIRE WITH SEALED WATERPROOF CONNECTORS REQUIRED.
14) INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS DETAILS AND
SPECIFICATIONS.
17) WHEN TRENCHING UNDER THE DRIPLINE OF EXISTING TREES EXTREME CARE MUST
BE GIVEN TO AVOID ROOT DAMAGE. IF AT ALL POSSIBLE AVOID TRENCHING INSIDE THE
DRIPLINE BY GOING AROUND THE TREE RATHER THAN UNDER IT. IF TRENCHING MUST
OCCUR UNDER THE DRIPLINE, USE EITHER TUNNELING OR HAND -DIGGING METHODS
RATHER THAN A MECHANICALTRENCHER. MINIMIZE THE IMPACTS OF ROOT SEVERING BY
AVOIDING CONSTRUCTION DURING HOT, DRY WEATHER, KEEPING TREES WELL WATERED
BEFORE AND AFTER DIGGING AND COVERING ROOTS WITH SOIL OR MULCH AS SOON AS
POSSIBLE.
NOTE:
SEE THE LANDSCAPE, DIMENSIONING, AND GRADING PLANS FOR
LOCATION OF WALKS, LIGHTS, WALLS AND OTHER FEATURES THAT
MAY IMPACT THE INSTALLATION OF THE IRRIGATION SYSTEM.
IRRIGATION DETAILS
P�EFORE yy
ARKANSAS STATE LAW REQUIRES THAT THE EXCAVATOR
IS TO LOCATE ALL EXISTING UTILITIES IN ACCORDANCE
WITH THE ARKANSAS UNDERGROUND FACILITIES DAMAGE
PREVENTION ACT. THIS LAW REQUIRES THAT THE EXCAVATOR
MAKE A TELEPHONE CALL TO THE ARKANSAS ONE CALL
SYSTEM AT 1-800-482-8995 AT LEAST TWO WORKING
DAYS PRIOR TO EXCAVATION TO INSURE THAT ANY EXISTING,
UTILITIES CAN BE LOCATED.
Seal
Drawing Type
IRRIGATION
DETAILS
Project No.
Date
09/19/06
Revisions
L A N D S G A P H
A FZ G H 1 T H G T S
ROBERT5 $
WILLIAM5
A550G I A7E5
1501 N. UNIVERSITY SUITE 430
LITTLE ROCK, AR 92207
(501) 2a0-0123
SHEET L3