Loading...
HomeMy WebLinkAboutZ-5758-C Map 4nua PRE5URE TREATED, PAINTED WOOD PICKETS WITH 5PAGE BETWEEN, PAINTED 'ION TO U5E T -II SIAM. 5TEEL P05T IN CONCRETE } PRESURE TREATED, PAINTED b' ' be 10017 FENCE SECTION L nrs:-a F li JgOOi7 FENCE ELEV. 1/4" = I"0" ("OUTSIDE" PAGE FROM PROJECT) UF) W 0- (Q v �a XN 4- W N Q l SL NOTE: INSTALL POLE5 4 BRGG. FACING THI5 DEVELOPMENT Aoop f=MNCM MLEY. ("INSIDE" FACE TO PROJECT) " ID SCREEN FENCE ONG. FILL YV (4) #4 /ERT. TO FOOTING GING 51ZE BRICK VENEER L GONG. FOOTING BELOW COLUMN PLAN 5/4" = 1'-0" O � V � m O �z ~W W a t ^c 11LL 1.-1 I X0 low IO. -O0 METER SCREEN ELEV. c1/4" = 1'-0" REFER UNIT PLAN rn PATIO ScoRMEN ELMS'. /4" = I' -O" K4 PRE5URE TREATED, PAINTED EMENT FIBER BOARD IDING 5X(o BALCONY COLUMN NHERE APPLICABLE ?X4 PRE5URE TREATED, PAINTED IL PATIO SCREEN SECTION 5/4" = I' -O" 2 SITE WORK 2.1 NOT U5ED 2.2 CONCRETE SIDEWALK, WIDTH AS NOTED ON PLAN S CONCRETE 5.1 FOUNDATION SYSTEM, REFER TO STRUCTURAL DRAWIN65 32 4' CONCRETE SLAB WITH 6X6, 10/10 WELDED Vi E MESH OVER WATERPROOF MEMBRANE ON MINIMUM 4"CRUSHED ROCK. 35 4" CONCRETE PATIO SLAB WITH 6Xb 10/10 MY ON 4" SAND CUSHION 5.4 FLOOFVCEIWN6 ASSEMBLY - REFER ASSEMBLY LEGEND 55 BREEZEWAY FLOOR/CEiLIN& ASSEMBLY - REFER ASSEMBLY LEGEND 4 MASONRY 4.1 8" CONCRETE RETAINING/STEM WAIL WITH WATERFROOFIN6 MEMBRANE 4 NICK PROTECTIVE BOARD ON EXTERIOR FACE AND WITH 5/8" GYP. BOARD ON 1X4 FURRN ON EXTERIOR FACE (SEE FOUNDATION ETAILOFOR REINFORCING). 4.2 8" CONCRETE STEM WALL. PAINT ALL EXPOSED SURFACES. ALL PORTIONS OF CONCRETE BLOCK STEM WALLS TO BE COVERED WITH 51DIN& ON FURRING STRIPS FOR ANY AREA TALLER THAN 8" ABOVE 6RADE. 45 16" SQUARE BRICK COLUMN ON 24" SQUARE FOOTING. 4.4 BRICK VENEER, REFER BUILDING PLANS. 4.5 BRICK SOLDIER COURSE, (COLOR MAY DIFFER FROM FIELD BRICK COLOR) ALT: 2X10 4.6 BRICK ROWLOCK COURSE. 5 METALS 5.1 STEEL FRAMED STAIR WITH PRECAST CONCRETE TREAD. b WOOD AND PLASTICS 6.1 TREATED 2X4 SOLE PLATE W/ 1/2" ROUND X 12" LONG A.B. AT 48" O.C. OR APPLICABLE CODE APPROVED TIE DOWN CLIP. INSTALL ANCHOR BOLT AT EACH END OF ALL SHORT WA.LL5 WITH A MINIMUM OF TWO A.B.'S PER SECTION OF WALL 62 STRUCTURAL 6RADE THERMAL PLY SHEATHIN6 (TYPICAL ALL LOCATIONS). 65 TRUSSED RAFTERS AT 24"OC. 6.4 1X4 TRU55 BRID61N6 AT TOP AND BOTTOM CHORDS AND X-BRID&IN& AT LAST & SPANS 65 101STS, AT MAXIMUM 8' 5PAGIN6S AT CONTRACTORS OPTION E SOLID 2X 5RIDGIN6. 6.6 2X10 BALCONY JOISTS (MOISTURE RESISTANT). 6.1 JOBT HANGER. 6.8 2X4 DECKING (MOISTURE RESISTANT). 2X6 DECKING MAY BE USED AT CONTRACTORS OPTION b.q 5/4" PLYWOOD ON FLOOR JOISTS OR FLOOR TRU55E5 WITH 5-1/2" BATT INSULATION. DOUBLE FLOOR TRUSSES UNDER NAILS PARALLEL TO TRUSS. 6.10 INSTALL HEADER TO FULL WIDTH OF OPENING AT OPENING ADJACENT TO EACH OTHER. 6.11 CONTIN/0US WOOD BLOCKIN6 6.12 2X6 RAFTER EXTENSIONS. 6.15 EXTERIOR WALL ASSEMBLY - REFER ASSEMBLY LE6END, W51 6.14 SEALANT JDINT AT ALL INTERSECTIONS OF 510IN6 TO TRIM 6.15 1/2" PLYWOOD. 6.16 bXb WOOD POST. b.lt 2 X 6 STUDS AT 16" O.G. 6.18 5/8" ROUGH 5ANN PLYWOOD SOFFIT WITH IX2 TRIM 6U9 5/4" PLYWOOD FIRE STOP OR 2X BLOOKIN6 6.20 2 X 12 RIM J015T OR EQUIVALENT 621 HOOD CHAIRRAIL AT DINING, ONLY. 622 PREFAB WOOD FIREPLACE MANTLE AND SURROUND. 6.25 GEMENT FIBERBOARD TRIM OVER 2X65 SUP BACKER. SOFFIT, GEMENT FIBERBOARD 6.24 WOOD TRIM 625 NOT USED 626 2X6WDDECKING. ALT.1: PRF55URE TREATED WOOD D.ECK. ALT2: KEYNOTE 35 654 PAINTED WOOD SILL X 10" DEEP AT WINDOW SILL HEI&HT. 635 GEILIN6 A55EMBLY -REFER ASSEMBLY LEGEND, W51 6.56 NOT USED. 6.31 2X12 5TRIN6ER, 658 FVRR DOM SHADED AREA TO 1'-O" A50VE FINISHED FLOOR U.O.N. 6,59 SLOPE CEILING WITH 5:12 PITCH, TYPICAL AT ALL TOP FLOOR LIVING ROOM CEILINGS AND BEDROOM CEILIN65 AB SHOWN ON UNIT PLAN 6.40 LINE OF GEILIN6 CHANGE. 6.41 STAIR RAIL 6.42 NALL CABINET AND SHELVES ABOVE 6.49 BASE CABINET AND SHELVES 6.44 DRAAER(5) TYPICAL 6.45 5 WOOD SHELVES, 12" DEEP TYPICAL. 6.46 NOT USED 6.41 NOT USED. 6.46 BREEZEWAY WALL ASSEMBLY - REFER A55FM13LY LEGEND NSI THEIWAL MID MOISTIUM PROTECTION 1.1 ROOF ASSEMBLY - REFER ASSEMBLY LEGEND, W51 12 BATT OR BLOWN INSULATION (R-30) TYPICAL ALL ROOF AREAS. 1.5 BATT INSULATION (R -IU. T.4 SEALANT 5 1.BATT INSULATION (R-15) TYPICAL ALL EXTERIOR NALLS. 1.6 PREFINI5HED GUTTER AND OOVAI5POVT WITH SPLASH 51-OOK. 1.7 DIVERTER, PREFINISMED TO MATCH SHINSLE5. 1.5 24 6A6E PAINTED, &ALV METAL CAP WITH HEMMED ED6E5. t.q 26 6A6E PAINTED, &ALV METAL STEP FLASHING 1.10 INSULATION TO BE CONTINUOUS AT ALL SUILDIN6 ENDS AT CHASE WALL TYPICAL. 1.11 POLY VAPOR BARRIER NRAPPEP AT PERIMETERIN6 OF ALL WINDOWS AND DOORS 1.12 WALL TO RECEIVE BATT INSULATION. 1.15 SADDLE, TYPICAL ALL PSEUDO CHIMNEYS. 1.14 FLASHING LET UNDER THRESHOLD D DOORS AND WINDOWS 8.1 V-10" X 2'-b" ATTIC ACCESS. REFER BLD&. PLAN 82 DIVIDED LITE, THERMAL BLAZED VINYL WINDOW W/ WHITE VINYL FINISH. 8.5 PAINTED, INSULATED, METAL GLAD, PANELIZED DOOR, W/ SPRING LOADED BUTTS. ALL DOORS TO HAVE DOOR VIEWER AND HAVE FOAM GORE. &.4 PAINTED, FULL SLABS W/ DIVIDED LITE, METAL CLAD INSULATED PATIO DOOR. IN5TALL STORM DOOR OR TRIPLE GLAZING WHERE REG UIRED. USE SAFETY BLABS. 85 DOOR BUCK AND TRIM. 8.6 PAINTED WOOD 511-1- AT NINDOW SILL HEIGHT 6.1 METAL THRESHOLD SET IN 5EALANT. 9 FINISHES q.1 ONE LAYER OF 1/2" GYP BD ATTIC DRAFT 5TOPPIN5 ABOVE AND IN LINE KITH ALL TENANT SEPARATION WALLS. q.2 ONE LAYER 5/8" GYP BOARD 95 TENANT SEPARATION WALL ASSEMBLY - REFER A55EMBLY LEGEND, W51 cIS EXTENT OF WALLPAPER BORDER IN KITCHEN AND BATH ONLY. 9.6 5/6" GYP BOARD ON 2X4 STUDS. 9.1 5/8" FIREGUARD GYP BOARD. 9.8 1/2" 6YP5UM BOARD. q.q CHAIRRAIL AT DINING. 9.10 CERAMIC TILE AT TUB ENCLOSURE. 9.11 8X5 CERAMIC TILE. ALT: 12X12 9.12 CANVAS ANNIN6. 9.13 PLASTIC LAMINATE NOSE, TOP, AND 4° H16H BACK AND END SPLASHES AT WALLS 1.14 1 HOUR RATED HALL A55EMBLY AT LOAD BEARING WALL5 AND ALL EXTERIOR MALLS. 9.15 CERAMIC TILE AT HEARTH. 9.16 LINE OF FLOOR MATERIAL CHANE. q.11 CARPETIN& FLOORING 9.18 NOT USED. q.1q VINYL FLOORING VV NO VINYL FLOORING UNDER DISH144SHER AT KITCHEN, TYR. 10 SPEGIUTIES 10.1 EXHAUST 6RILLE, W/ HARDWARE CLOTH COVER. 102 PAINTED WOOD OR 6ALV MTL ROOF VENTILATION LOUVER VV BACKING SCREEN., 51ZE TO BE IN ACCORDANCE KITH CODE REQUIREMENTS. 103 MAIL BOXES 10.4 TOWEL BAR AT 4'-b" A.F.F., PROVIDE 2X6 5LOCKIN& FLAT IN WALL. 105 BRAS BAR AND SOAP HOLDER, TYPICAL ALL TUB ENCLOSURES, PROVIDE 2" BLOGKIN FLAT IN WALL. 10.6 I/4° POLISHED PLATE MIRROR WITH MAXIMUM SAP OF I" AT PERIMETER OF MIRROR II MWIPMENT 11.1 MICROWAVE OVEN / RANGE HOOD COMBINATION. 112 REFRIGERATOR W/ ICEMAKER. il3 12I5HNASHER 11.4 5O" RAN6E 11.5 RASHER (N.I.C) 11.6 DRYER 15 MECHANICAL 15.1 PLUMBING ACCESS PANEL, TYPICAL ALL TUB / 5HOWER LOCATION5. 152 HOT WATER HEATER ACCESS PANEL, TYPICAL AT WATER HEATER LOCATIONS. 155 EXHAUST FAN, VENT THROUGH ROOF AT TOP FLOOR THROUGH WALL VIA FLOOR FRAMING SPACE AT ALL OTHER FLOORS, TERMINATING DEVICE TO HAVE HARDWARE CLOTH COVER, 15.4 CONDENSING UNITS ON CONC. PAD, PRECAST OR PREFORMED PAD. ALL REFR16. LINES TO BE COMPLETELY CONGEALED FROM VISA. 15.5 DRYER VENT, VENT THRO ROOF AT TOP FLOOR THRU WALL VIA FLOOR JOIST SPACE AT ALL OTHER FLOORS. TERMINATING DEVICE TO HAVE HARDNARE CLOTH COVER. 15.6 POP-OFF AND CONDENSATE DRAIN FOR WATER HEATER 15.1 ROOF MOUNTED ATTIC, VENTS PER APPLICABLE CODE REOI)AM-SNTS. 15.8 NATER METERS 15.9 PREFABRICATED VA5HER HOOK-UP BOX, PROVIDE HOT AND GOLD WATER SUPPLY AND DRAIN &LEVER TYPE STOP VALVE. 15.10 RANGE HOOD VENT, VENT THRU ROOF AT TOP FLOOR, THRU WALL VIA FLOOR J015T SPACE AT ALL OTHER FLOORS. TERMINATING DEVICE TO HAVE HARDWARE CLOTH COVER. 15.11 ENCASE SPRINKLER PIPES W/ RIGID INSULATION AT ALL BREEZENAY LOCATIONS, REFER FIRE SPRINKLER PLANS. IG, ELECTRICAL 16.1 ELECTRICAL METERS, TYPICAL LOCATION 16.2 J -BOX FOR RANEE HOOD ON SEPARATE CIRCUIT -120V 16.5 JUNCTION BOX FOR DISHWASHER - 120V 16.4 JUNCTION BOX FOR DISPOSAL - 120V 16.5 JUNCTION BOX FOR FURNACE - 240V Ibb JUNCTION BOX FOR WATER HEATER - 24OV 16.1 LTU I6HT FIXTURE, TYPICAL DE516MATION 16.8 ELECTRO FURNACE 16.9 ELECTRIC WATER HEATER SEAL: NOTICE OF OOPYNCI T THESE PLANS ARE COPYRIGHTED AND ARE SU8UECT TO COPYRIGHT PROTECTION AS AN ARCHITECTURAL WORK UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR BUILDINGS REPRESENTED CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/OR MONETARY COMPENSATION TC ARCHITECTS COLLECTIVE. FT O CAD FILES WILL BE PROVIDED O SUB -CONTRACTORS UNDER ANY IRCUMSTANCES. CSD K . to l� H 1 7 IE C T 4200 EAST SKELLY DRIVE SUITE 750 TULSA, OKLAHOMA 74135 918/492-2987 PROJECT NUMBER: DATE: SHEET TITLE: FENCE DETAILS SHEET NUMBER: Q Q O a 0 W 11.1 u - m 13 o 7- Q T z_ x Lu W Q U N XQ N o- NOTE: P05T5 MAY BE OMITTED WHEN L LIPATIO 50REEN d IS INSTALLED BETWEEN BRICK BUILDING COLUMN5 ------n REFER UNIT PLAN rn PATIO ScoRMEN ELMS'. /4" = I' -O" K4 PRE5URE TREATED, PAINTED EMENT FIBER BOARD IDING 5X(o BALCONY COLUMN NHERE APPLICABLE ?X4 PRE5URE TREATED, PAINTED IL PATIO SCREEN SECTION 5/4" = I' -O" 2 SITE WORK 2.1 NOT U5ED 2.2 CONCRETE SIDEWALK, WIDTH AS NOTED ON PLAN S CONCRETE 5.1 FOUNDATION SYSTEM, REFER TO STRUCTURAL DRAWIN65 32 4' CONCRETE SLAB WITH 6X6, 10/10 WELDED Vi E MESH OVER WATERPROOF MEMBRANE ON MINIMUM 4"CRUSHED ROCK. 35 4" CONCRETE PATIO SLAB WITH 6Xb 10/10 MY ON 4" SAND CUSHION 5.4 FLOOFVCEIWN6 ASSEMBLY - REFER ASSEMBLY LEGEND 55 BREEZEWAY FLOOR/CEiLIN& ASSEMBLY - REFER ASSEMBLY LEGEND 4 MASONRY 4.1 8" CONCRETE RETAINING/STEM WAIL WITH WATERFROOFIN6 MEMBRANE 4 NICK PROTECTIVE BOARD ON EXTERIOR FACE AND WITH 5/8" GYP. BOARD ON 1X4 FURRN ON EXTERIOR FACE (SEE FOUNDATION ETAILOFOR REINFORCING). 4.2 8" CONCRETE STEM WALL. PAINT ALL EXPOSED SURFACES. ALL PORTIONS OF CONCRETE BLOCK STEM WALLS TO BE COVERED WITH 51DIN& ON FURRING STRIPS FOR ANY AREA TALLER THAN 8" ABOVE 6RADE. 45 16" SQUARE BRICK COLUMN ON 24" SQUARE FOOTING. 4.4 BRICK VENEER, REFER BUILDING PLANS. 4.5 BRICK SOLDIER COURSE, (COLOR MAY DIFFER FROM FIELD BRICK COLOR) ALT: 2X10 4.6 BRICK ROWLOCK COURSE. 5 METALS 5.1 STEEL FRAMED STAIR WITH PRECAST CONCRETE TREAD. b WOOD AND PLASTICS 6.1 TREATED 2X4 SOLE PLATE W/ 1/2" ROUND X 12" LONG A.B. AT 48" O.C. OR APPLICABLE CODE APPROVED TIE DOWN CLIP. INSTALL ANCHOR BOLT AT EACH END OF ALL SHORT WA.LL5 WITH A MINIMUM OF TWO A.B.'S PER SECTION OF WALL 62 STRUCTURAL 6RADE THERMAL PLY SHEATHIN6 (TYPICAL ALL LOCATIONS). 65 TRUSSED RAFTERS AT 24"OC. 6.4 1X4 TRU55 BRID61N6 AT TOP AND BOTTOM CHORDS AND X-BRID&IN& AT LAST & SPANS 65 101STS, AT MAXIMUM 8' 5PAGIN6S AT CONTRACTORS OPTION E SOLID 2X 5RIDGIN6. 6.6 2X10 BALCONY JOISTS (MOISTURE RESISTANT). 6.1 JOBT HANGER. 6.8 2X4 DECKING (MOISTURE RESISTANT). 2X6 DECKING MAY BE USED AT CONTRACTORS OPTION b.q 5/4" PLYWOOD ON FLOOR JOISTS OR FLOOR TRU55E5 WITH 5-1/2" BATT INSULATION. DOUBLE FLOOR TRUSSES UNDER NAILS PARALLEL TO TRUSS. 6.10 INSTALL HEADER TO FULL WIDTH OF OPENING AT OPENING ADJACENT TO EACH OTHER. 6.11 CONTIN/0US WOOD BLOCKIN6 6.12 2X6 RAFTER EXTENSIONS. 6.15 EXTERIOR WALL ASSEMBLY - REFER ASSEMBLY LE6END, W51 6.14 SEALANT JDINT AT ALL INTERSECTIONS OF 510IN6 TO TRIM 6.15 1/2" PLYWOOD. 6.16 bXb WOOD POST. b.lt 2 X 6 STUDS AT 16" O.G. 6.18 5/8" ROUGH 5ANN PLYWOOD SOFFIT WITH IX2 TRIM 6U9 5/4" PLYWOOD FIRE STOP OR 2X BLOOKIN6 6.20 2 X 12 RIM J015T OR EQUIVALENT 621 HOOD CHAIRRAIL AT DINING, ONLY. 622 PREFAB WOOD FIREPLACE MANTLE AND SURROUND. 6.25 GEMENT FIBERBOARD TRIM OVER 2X65 SUP BACKER. SOFFIT, GEMENT FIBERBOARD 6.24 WOOD TRIM 625 NOT USED 626 2X6WDDECKING. ALT.1: PRF55URE TREATED WOOD D.ECK. ALT2: KEYNOTE 35 654 PAINTED WOOD SILL X 10" DEEP AT WINDOW SILL HEI&HT. 635 GEILIN6 A55EMBLY -REFER ASSEMBLY LEGEND, W51 6.56 NOT USED. 6.31 2X12 5TRIN6ER, 658 FVRR DOM SHADED AREA TO 1'-O" A50VE FINISHED FLOOR U.O.N. 6,59 SLOPE CEILING WITH 5:12 PITCH, TYPICAL AT ALL TOP FLOOR LIVING ROOM CEILINGS AND BEDROOM CEILIN65 AB SHOWN ON UNIT PLAN 6.40 LINE OF GEILIN6 CHANGE. 6.41 STAIR RAIL 6.42 NALL CABINET AND SHELVES ABOVE 6.49 BASE CABINET AND SHELVES 6.44 DRAAER(5) TYPICAL 6.45 5 WOOD SHELVES, 12" DEEP TYPICAL. 6.46 NOT USED 6.41 NOT USED. 6.46 BREEZEWAY WALL ASSEMBLY - REFER A55FM13LY LEGEND NSI THEIWAL MID MOISTIUM PROTECTION 1.1 ROOF ASSEMBLY - REFER ASSEMBLY LEGEND, W51 12 BATT OR BLOWN INSULATION (R-30) TYPICAL ALL ROOF AREAS. 1.5 BATT INSULATION (R -IU. T.4 SEALANT 5 1.BATT INSULATION (R-15) TYPICAL ALL EXTERIOR NALLS. 1.6 PREFINI5HED GUTTER AND OOVAI5POVT WITH SPLASH 51-OOK. 1.7 DIVERTER, PREFINISMED TO MATCH SHINSLE5. 1.5 24 6A6E PAINTED, &ALV METAL CAP WITH HEMMED ED6E5. t.q 26 6A6E PAINTED, &ALV METAL STEP FLASHING 1.10 INSULATION TO BE CONTINUOUS AT ALL SUILDIN6 ENDS AT CHASE WALL TYPICAL. 1.11 POLY VAPOR BARRIER NRAPPEP AT PERIMETERIN6 OF ALL WINDOWS AND DOORS 1.12 WALL TO RECEIVE BATT INSULATION. 1.15 SADDLE, TYPICAL ALL PSEUDO CHIMNEYS. 1.14 FLASHING LET UNDER THRESHOLD D DOORS AND WINDOWS 8.1 V-10" X 2'-b" ATTIC ACCESS. REFER BLD&. PLAN 82 DIVIDED LITE, THERMAL BLAZED VINYL WINDOW W/ WHITE VINYL FINISH. 8.5 PAINTED, INSULATED, METAL GLAD, PANELIZED DOOR, W/ SPRING LOADED BUTTS. ALL DOORS TO HAVE DOOR VIEWER AND HAVE FOAM GORE. &.4 PAINTED, FULL SLABS W/ DIVIDED LITE, METAL CLAD INSULATED PATIO DOOR. IN5TALL STORM DOOR OR TRIPLE GLAZING WHERE REG UIRED. USE SAFETY BLABS. 85 DOOR BUCK AND TRIM. 8.6 PAINTED WOOD 511-1- AT NINDOW SILL HEIGHT 6.1 METAL THRESHOLD SET IN 5EALANT. 9 FINISHES q.1 ONE LAYER OF 1/2" GYP BD ATTIC DRAFT 5TOPPIN5 ABOVE AND IN LINE KITH ALL TENANT SEPARATION WALLS. q.2 ONE LAYER 5/8" GYP BOARD 95 TENANT SEPARATION WALL ASSEMBLY - REFER A55EMBLY LEGEND, W51 cIS EXTENT OF WALLPAPER BORDER IN KITCHEN AND BATH ONLY. 9.6 5/6" GYP BOARD ON 2X4 STUDS. 9.1 5/8" FIREGUARD GYP BOARD. 9.8 1/2" 6YP5UM BOARD. q.q CHAIRRAIL AT DINING. 9.10 CERAMIC TILE AT TUB ENCLOSURE. 9.11 8X5 CERAMIC TILE. ALT: 12X12 9.12 CANVAS ANNIN6. 9.13 PLASTIC LAMINATE NOSE, TOP, AND 4° H16H BACK AND END SPLASHES AT WALLS 1.14 1 HOUR RATED HALL A55EMBLY AT LOAD BEARING WALL5 AND ALL EXTERIOR MALLS. 9.15 CERAMIC TILE AT HEARTH. 9.16 LINE OF FLOOR MATERIAL CHANE. q.11 CARPETIN& FLOORING 9.18 NOT USED. q.1q VINYL FLOORING VV NO VINYL FLOORING UNDER DISH144SHER AT KITCHEN, TYR. 10 SPEGIUTIES 10.1 EXHAUST 6RILLE, W/ HARDWARE CLOTH COVER. 102 PAINTED WOOD OR 6ALV MTL ROOF VENTILATION LOUVER VV BACKING SCREEN., 51ZE TO BE IN ACCORDANCE KITH CODE REQUIREMENTS. 103 MAIL BOXES 10.4 TOWEL BAR AT 4'-b" A.F.F., PROVIDE 2X6 5LOCKIN& FLAT IN WALL. 105 BRAS BAR AND SOAP HOLDER, TYPICAL ALL TUB ENCLOSURES, PROVIDE 2" BLOGKIN FLAT IN WALL. 10.6 I/4° POLISHED PLATE MIRROR WITH MAXIMUM SAP OF I" AT PERIMETER OF MIRROR II MWIPMENT 11.1 MICROWAVE OVEN / RANGE HOOD COMBINATION. 112 REFRIGERATOR W/ ICEMAKER. il3 12I5HNASHER 11.4 5O" RAN6E 11.5 RASHER (N.I.C) 11.6 DRYER 15 MECHANICAL 15.1 PLUMBING ACCESS PANEL, TYPICAL ALL TUB / 5HOWER LOCATION5. 152 HOT WATER HEATER ACCESS PANEL, TYPICAL AT WATER HEATER LOCATIONS. 155 EXHAUST FAN, VENT THROUGH ROOF AT TOP FLOOR THROUGH WALL VIA FLOOR FRAMING SPACE AT ALL OTHER FLOORS, TERMINATING DEVICE TO HAVE HARDWARE CLOTH COVER, 15.4 CONDENSING UNITS ON CONC. PAD, PRECAST OR PREFORMED PAD. ALL REFR16. LINES TO BE COMPLETELY CONGEALED FROM VISA. 15.5 DRYER VENT, VENT THRO ROOF AT TOP FLOOR THRU WALL VIA FLOOR JOIST SPACE AT ALL OTHER FLOORS. TERMINATING DEVICE TO HAVE HARDNARE CLOTH COVER. 15.6 POP-OFF AND CONDENSATE DRAIN FOR WATER HEATER 15.1 ROOF MOUNTED ATTIC, VENTS PER APPLICABLE CODE REOI)AM-SNTS. 15.8 NATER METERS 15.9 PREFABRICATED VA5HER HOOK-UP BOX, PROVIDE HOT AND GOLD WATER SUPPLY AND DRAIN &LEVER TYPE STOP VALVE. 15.10 RANGE HOOD VENT, VENT THRU ROOF AT TOP FLOOR, THRU WALL VIA FLOOR J015T SPACE AT ALL OTHER FLOORS. TERMINATING DEVICE TO HAVE HARDWARE CLOTH COVER. 15.11 ENCASE SPRINKLER PIPES W/ RIGID INSULATION AT ALL BREEZENAY LOCATIONS, REFER FIRE SPRINKLER PLANS. IG, ELECTRICAL 16.1 ELECTRICAL METERS, TYPICAL LOCATION 16.2 J -BOX FOR RANEE HOOD ON SEPARATE CIRCUIT -120V 16.5 JUNCTION BOX FOR DISHWASHER - 120V 16.4 JUNCTION BOX FOR DISPOSAL - 120V 16.5 JUNCTION BOX FOR FURNACE - 240V Ibb JUNCTION BOX FOR WATER HEATER - 24OV 16.1 LTU I6HT FIXTURE, TYPICAL DE516MATION 16.8 ELECTRO FURNACE 16.9 ELECTRIC WATER HEATER SEAL: NOTICE OF OOPYNCI T THESE PLANS ARE COPYRIGHTED AND ARE SU8UECT TO COPYRIGHT PROTECTION AS AN ARCHITECTURAL WORK UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR BUILDINGS REPRESENTED CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/OR MONETARY COMPENSATION TC ARCHITECTS COLLECTIVE. FT O CAD FILES WILL BE PROVIDED O SUB -CONTRACTORS UNDER ANY IRCUMSTANCES. CSD K . to l� H 1 7 IE C T 4200 EAST SKELLY DRIVE SUITE 750 TULSA, OKLAHOMA 74135 918/492-2987 PROJECT NUMBER: DATE: SHEET TITLE: FENCE DETAILS SHEET NUMBER: