HomeMy WebLinkAboutZ-5718 Map 5I
II I' I I I i i I
Existing Fire Hydrant ---
I i i I
Existing 1 story
office building
Proposed 1
Story Office
Building
AC Pad
Note: Two (2) existing power drops
to separate meters. Connect
proposed electrical to one story
metal building to the north. NO
electrical connections are to be
made between the Proposed Office
Building and the Existing Office
Building \
Site Plan
1"=10'
Existing 1 story
metal building
Water and Sewer: Connect to
existing building services
Project Information:
Project Name: West Tree Service
Project Locaton: 6300 Forbing Road
Little Rock, AR 72209
Type Construction: Type V / unprotected / unsprinkled
Building s.f. 1573 s.f. addition / 6720 s.f. combined
Building height: 12' at eave / 14' at peak
Foundation: Slab on grade
Occupants Five (5) (addition)
Live Loads: Frames - 20 psf
Purlins - 20 psf
Wind load: IBC 90 mph
Ground snow load: 10 psf
Collateral & aux. 5 psf
Seismic loads: IBC 2000 Seismic Spectral Accelerations Coefficient sds = .70