Loading...
HomeMy WebLinkAboutZ-5700-B Map 4VICINITY MAP WM NTS LEGEND 0 EXISTING LIGHT POLE UGTV PROPOSED UNDERGROUND TELEVISION O EXISTING MANHOLE 1 6 G 7 GP PROPOSED MANHOLE .. - --- EXISTING WOOD FENCE J PROPOSED GAS METER // PROPOSED WOOD FENCE P R 0 J THICKORY C DRQ _ �._ VL EXISTING GRATED INLET LOCA _._ _: Z PROPOSED CHAIN LINK FENCE y\ EXISTING DROP INLET WEST PROPOSED DROP INLET _,DR ray PRIDE VALLEY RD-- EXISTING EASEMENT � ` � cT w 4.• ' LO � T VCH 'P HYCf1N Ldp a SWEET BA DR ellv _. _Alz ... ST '-'-' BAKER LN� BAKER' L 1 c U V ULD tHERRRYY D CT QLU J SS Q m VICINITY MAP WM NTS LEGEND 0 EXISTING LIGHT POLE X EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY PROPOSED EASEMENT PROPOSED BARBED WIRE FENCE PROPOSED CURB EXISTING CURB TO REMAIN PROPOSED 25' DRIVEWAY (ONE-WAY STACK) RELOCATED CHAIN LINK FENCE GRAPHIC SCALE IN FEET 60' 0 60' ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. SAFETY NOTICE TO CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. 00, G ROCK PLANPIING CONIA�ISSION \ UTILE SUWI CT TO THE GOND (IONS V ApPFOVED, r oG�g,rgp a �Ca4I'115SfON 1N 71 n1a� o\-_ \ DATE: END NEW CURB 4 \\ \ - EXISTING 40-r — — --- SOUTH --SOUTH SIDE EXISTING R/W UGTV PROPOSED UNDERGROUND TELEVISION O EXISTING MANHOLE - SPARKS& D ASSOCIATES, INC. OHTV PROPOSED OVERHEAD TELEVISION O PROPOSED MANHOLE .. - --- EXISTING WOOD FENCE A PROPOSED GAS METER // PROPOSED WOOD FENCE -- -- EXISTING BARBED WIRE FENCE EXISTING GRATED INLET ® PROPOSED GRATED INLET ---- -- -- EXISTING CHAIN LINK FENCE Z PROPOSED CHAIN LINK FENCE EXISTING DROP INLET PROPERTY LINE PROPOSED DROP INLET ---- ---- BUILDING SET BACK ray EXISTING EASEMENT X EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY PROPOSED EASEMENT PROPOSED BARBED WIRE FENCE PROPOSED CURB EXISTING CURB TO REMAIN PROPOSED 25' DRIVEWAY (ONE-WAY STACK) RELOCATED CHAIN LINK FENCE GRAPHIC SCALE IN FEET 60' 0 60' ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. SAFETY NOTICE TO CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. 00, G ROCK PLANPIING CONIA�ISSION \ UTILE SUWI CT TO THE GOND (IONS V ApPFOVED, r oG�g,rgp a �Ca4I'115SfON 1N 71 n1a� o\-_ \ DATE: END NEW CURB 4 \\ \ - EXISTING 40-r — — --- SOUTH --SOUTH SIDE EXISTING R/W F— CRAFfON, TALL, - SPARKS& D ASSOCIATES, INC. y No.1W J NSAS ARKANAS REGISTERED PROFESSIONAL ✓F RY/J J. 1/nl� W '.t .he LO sm >-� N� E H CL_ �Q� a))c`" a.o H UOQ Q �LL_} U}Ln C C J d 0 CS 04 � �� U L NN�q Co V :- 003 0n c4il 0) W^ Revision 00 . OVERALL SITE PLAN Drown by CSO Checked by Date 04/18/08 Job Number 599-02 Contact Person J. KELSO Sheet Numoer C 1� F— U —7 Z =)LU ®LU ray '-'-' V) U w QLU J J Q m U LU Revision 00 . OVERALL SITE PLAN Drown by CSO Checked by Date 04/18/08 Job Number 599-02 Contact Person J. KELSO Sheet Numoer C 1�