Loading...
HomeMy WebLinkAboutZ-5574-C Maps T -MOBILE SITE NUMBER: AR01215A @►� a : UNICA110I�5 Mob 1 T -MOBILE SITE NAME: WEST LITTLE ROCK ��> as ATC SITE NUMBER: 418812 ..° No. 2921 i e ATC SITE NAME: METHODIST CHILDREN'S HOME ®°°°o'�9KANS °° 12980 FOSTER, SUITE 200, OVERLAND PARK, KS 66213 SITE ADDRESS: 2194 S FILLMORE ST ®B4788004nfl9°�° LITTLE ROCK AR 72204 NEW EQUIPMENT AND ANTENNAS ON: EXISTING 150' MONOPOLE SITE INFORMATION °° s pie Searcy_ a' '. I 1( a ISI '"'$`r _ DRAWING INDEX Da"danella — 19th..S7 _ _ ^. . —I 11 —� SITE TYPE: MONOPOLE µ°r*slta� A N s SITE NAME: a s f. NO DESCRIPTION I� �. WEST LITTLE ROCK Conway MI ChaTIBs gU2ggY �,�'e � T7 TITLE SHEET Des Aro !� L� GN1 GENERAL NOTES SITE NUMBER: AR01215A AR -01215 AR -01215 U N I T E 34•7325°N92•33074p W 34.73253°NYW� GN2 GENERAL NOTES SITE ADDRESS: 2194 S FILLMORE ST 3G'iiC1 She LITTLE ROCK, AR 72204 larril `k.CkSfrrMe ° Rt C1 OVERALL AND ENLARGED SITE PLANS btSi j,pnp(a 0lV ells COUNTY: PULASKI COUNTY Rock Clarendon° C2 ANTENNA ORIENTATION, MOUNT AND SCHEDULE JURISDICTION: CITY OF LITTLE ROCK C3 ANTENNA SCHEDULE OCCUPANCY TYPE: UNMANNED �Spdn9s n1Qn r °StuHpart Me C4 WAVEGUIDE DETAILS }i. Rock S1 CONCRETE PAD DETAILS A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR � � HUMAN HABITATION. p it lvern o i iI • J7 E1 UTILITY PLAN AND CONDUIT LAYOUT DIAGRAM APPLICANT: T—MOBILED I —� E2 ELECTRICAL DETAILS 12980 FOSTER ST Lane Bull 11S � — E3 PPC H—FRAME DETAILS OVERLAND PARK, KS 66213 I 877-878-7326 A&,xdvIphiaIE �1 E4 ANTENNA ONE—LINE DIAGRAM SITE COORDINATES (NAD 83): W 25th.St^ G1 COMPOUND GROUNDING PLAN LATITUDE: N. 34.73253 Rlson LONGITUDE: W. —92.33874 star City G2 GROUNDING DETAILS ° � I GROUND ELEVATION: 320' (AMSC) aDumas I i G3 GROUNDING DETAILS O PROPERTY OWNER: VICINITY MAP N.T.S. LOCATION MAP N.T.S. " METHODIST CHILDREN'S HOME e '•."R nom-- �— ^� 501-661-0720 TOWER OWNER ci DRIVING DIRECTIONS :� •��`-on'%NICF Permit. ATC116 HUNTINGTON AVE 11TH FLOOR DEPART LITTLE ROCK NATIONAL AIRPORT EXIT ROAD NAME CHANGES TO ANNIE M BANKHEAO OR [BANKHEAD OR] 0.3 MI, TAKE RAMP J� % Z BONSTON, MA. 02116 (RIGHT) ONTO 1-4402.3 MI, 1-30 / DOWNTOWN HOT SPRINGS / TEXARKANA AT EXIT 138A, TAKE RAMP (RIGHT) ONTO 1-30 [US -167]1.3 = _ 877-518-6937 Mt, 1--30 E / US -167 N / US -65 N / DOWNTOWN AT EXIT 139 B, TAKE RAMP (RIGHT) ONTO 1-630 5.0 MI, 1-630 AT EXIT 58, TAKE " SITE NAME: METHODIST CHILDREN'S HOME RAMP (RIGHT) ONTO S UNIVERSITY AVE 0.5 MI, SOUTH UNIVERSITY AVENUE TURN LEFT (EAST) ONTO W 12TH ST 0.2 MI, TURN RIGHT 9 SITE NUMBER: 418812 (SOUTH) ONTO S PIERCE ST 0.5 MI, TURN RIGHT (WEST) ONTO W CHARLES BUSSEY AVE 43 YDS, TURN LEFT (SOUTH) ONTO LOCAL E ROAD(S) 0.1 MI, ARRIVE AR -01215. �� PLt�i': �O 1 ' MANAGED BY: EMILY COVER PHONE: 781-926-4982 A&E DRAWING REVIEW ONE CALL NUMBER: CODE COMPLIANCE �- DESIGNER: S BRANCH COMMUNICATIONS, LLC CALL ARKANSAS N 1516 SOUTH BOSTON AVE. STE 215 TITLE: SIGNATURE: DATE: ONE CALL 811 ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN " TULSA, OK. 74119 CONTACT. JAMES W MCCOY PROPERTY OWNER: 8OO 482-8998 ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING PHONE: (916) 261-1875 _ ( � CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. m T—MOBILE CONSTRUCTION MGR: � CALL 3 WORKING DAYS NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT ARCHITECT/ENGINEER: ZONING APPROVAL: BEFORE YOU DIG! WORK NOT CONFORMING TO THESE CODES. SPECIALTY TELECOMMUNICATIONS SERVICES, LLC BUILDING/DWELLING CODE: IBC 2009 PROFESSIONAL ENGINEERS AND CONSULTANTS RF ENGINEER: 0 13431 N. BROADWAY. STE 120 d— OKLAHOMA CITY, OK. 73114 SITE ACQUISITION: STRUCTURAL CODE: IBC 2009 CONTACT: JOHN COOK STATUS CODE: I PLUMBING CODE: IPC 2009 PHONE: (405) 753-7167 DO NOT SCALE DRAWINGS 1 ACCEPTED—WTTt{ OR NO COMMENTS, CONSTRUCTION MAY PROCEED TELEPHONE COMPANY: POWER COMPANY: MECHANICAL CODE: IMC 2009 AT&T ENTERGY 2 NOT ACCEPTED—RESOLVE COMMENTS AND RESUBMIT CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS a AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY ELECTRIC CODE: NEC 2011 THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS N AND DDOUMAvrHoRrZENT THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE THE CONTRACTOR TO PROCEED HE THE CONSTRUCTION DESCRIBED HEREIN. ALL DOCUMENTS NFOA 101 ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND MAY IMPOSE CHANGES PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. FIRE/LIFE SAFELY CODE: IBC 2009, IFC 2009, OR MODIFICATIONS. VENDOR: 1. r nMobileu 7668 WARREN PKY, STE 100 FRISCO, TX 75034 SPECIALTY TELECOMMUNICATIONS SERJICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CRY, OK 73114 (405) 753-7167 BY: BR NCH COMMUN/CAT/ONS,LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA., OKLAHOMA 74119 (918) 949-4551 SITE NAME: 'WEST LITTLE ROCK 3TS NUMBER: AR01215A :SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 (PROJECT NUMBER: AR01215A ENGINEER: 'off SSn�p _ `i ARKANSAS rte c E r t I-PFj�QF S� PSL S e EN *I**ER ,1� No. 16564 R�8,16 PE #16564 MXP 12/31/17 IVO DATE DESCRIPTION A 10/24/14[ PRELIM ISSUE B 3/3/15 PRELIM ISSUE PRELIM ISSUE PRELIM ISSUE PRELIM ISSUE M41/7 JB PRELIM ISSUE 0 4 8 15 CONST ISSUE 9/13 15 CONSTISSUE 2 5 18 16 CONST ISSUE :SHEET TITLE: TITLE SHEET SHEET #: 1 PROJECT #: AR01215A - L 13Y: non CKD: JWM DIVISION 1 - GENERAL REQUIREMENTS 1.1 INTENT A. THESE SPECIFICATIONS AND CONSTRUCTION DRAWINGS ACCOMPANYING THEM DESCRIBE THE WORK TO BE DONE AND THE MATERIALS TO BE FURNISHED FOR CONSTRUCTION. B. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE FULLY EXPLANATORY AND SUPPLEMENTARY. HOWEVER, SHOULD ANYTHING BE SHOWN, INDICATED OR SPECIFIED ON AND NOT THE OTHER, IT SHALL BE ACCOMPLISHED AS IF SHOWN, INDICATED OR SPECIFIED IN BOTH. C. THE INTENTION OF THE DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS REASONABLY NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK STIPULATED IN THE CONTRACT. D. THE PURPOSE OF THE SPECIFICATIONS IS TO INTERPRET THE INTENT OF THE DRAWINGS AND TO DESIGNATE THE METHOD OF THE PROCEDURE, TYPE AND QUALITY OF MATERIALS REQUIRED TO COMPLETE THE WORK. E. MINOR DEVIATIONS FROM THE DESIGN LAYOUT ARE ANTICIPATED AND SHALL BE CONSIDERED AS PART OF THE WORK. NO CHANGES THAT ALTER THE CHARACTER OF THE WORK WILL BE MADE OR PERMITTED BY THE OWNER WITHOUT ISSUING A CHANGE ORDER. 1. 1.2 CONFLICTS A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OFF ALL MEASUREMENTS AT THE SITE BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK. NO EXTRA CHARGE OR COMPENSATION SHALL BE ALLOWED DUE TO DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND DIMENSIONS INDICATED ON THE CONSTRUCTION DRAWINGS. ANY SUCH DISCREPANCY IN DIMENSION WHICH MAY BE FOUND SHALL BE SUBMITTED TO THE OWNER FOR CONSIDERATION BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK IN THE AFFECTED AREAS, B. THE BIDDER, IF AWARDED THE CONTRACT, WILL NOT BE ALLOWED ANY EXTRA COMPENSATION MY REASON OF ANY MATTER OR THING CONCERNING WHICH SUCH BIDDER MIGHT HAVE BEEN FULLY INFORMED PRIOR TO BIDDING. C. NO PLEA OF IGNORANCE OF CONDITIONS THAT EXIST, OR OF DIFFICULTIES OR CONDITIONS THAT MAY BE ENCOUNTERED OR OF ANY OTHER RELEVANT MATTER CONCERNING THE WORK TO BE PERFORMED IN THE EXECUTION OF THE WORK WILL BE ACCEPTED AS AN EXCUSE FOR ANY FAILURE OR OMISSION ON THE PART OF THE CONTRACTOR TO FULFILL EVERY DETAIL OF ALL THE REQUIREMENTS OF THE CONTRACT DOCUMENTS GOVERNING THE WORK, 1.3 CONTRACTS AND WARRANTIES A. EACH CONTRACTOR IS RESPONSIBLE FOR OBTAINING THE BUILDING PERMIT AT THE LOCAL JURISDICTION AS THE CONTRACTOR — OF— RECORD. AND PROVIDING JURISDICTION WITH ALL PROOF REQUIRED TO OPERATE AS A CONTRACTOR IN THAT JURISDICTION. THE CONTRACTOR SHALL BE REIMBURSED ONLY THE AMOUNT OF ANY FEE PAID AS FOLLOWS: 1. PLAN REVIEW FEE. 2. BUILDING PERMIT FEE. 3. CONNECTIONS AND INSPECTIONS FEE. B. CONTRACTOR IS RESPONSIBLE FOR APPLICATION AND PAYMENT OF CONTRACTOR LICENSES AND BONDS. 1.4 STORAGE ALL MATERIALS MUST BE STORED IN A LEVEL AND DRY FASHION AND IN A MANNER THAT DOES NOT NECESSARILY OBSTRUCT THE FLOW OF OTHER WORK. ANY STORAGE METHOD MUST MEET ALL RECOMMENDATIONS OF THE ASSOCIATED MANUFACTURER. 1.5 CLEAN UP A. THE CONTRACTORS AT ALL TIME SHALL KEEP THE SITE FREE FROM ACCUMULATION > OF WASTE MATERIALS OR RUBBISH CAUSED BY THEIR EMPLOYEES AT WORK AND AT THE COMPLETION OF THE WORK, THEY SHALL REMOVE ALL RUBBISH FROM AND ABOUT THE BUILDING AREA. INCLUDING ALL THEIR TOOLS, SCAFFOLDING AND SURPLUS MATERIALS AND SHALL LEAVE THEIR WORK CLEAN AND READY FOR USE B. EXTERIOR: VISUALLY INSPECTED EXTERIOR SURFACES AND REMOVE ALL TRACES OF SOIL, WASTE MATERIALS, SMUDGES AND OTHER REGION MATTER. 1. REMOVE ALL TRACES OF SPLASHED MATERIALS FROM ADJACENT SURFACES. 2. IF NECESSARY TO ACHIEVE A UNIFORM DEGREE OF CLEANLINESS, HOES DOWN THE EXTERIOR OF THE STRUCTURE. C. INTERIOR: VISUALLY INSPECT INTERIOR SURFACES AND REMOVE ALL TRACES OF SOIL, WASTE MATERIALS, SMUDGES AND OTHER FOREIGN MATTER FROM WALLS/FLOOR/CEILING. a 1. REMOVE ALL TRACES OF SPLASHED MATERIALS FROM ADJACENT SURFACES. 2. REMOVE PAINT DROPPINGS, SPOTS, STAINS AND DIRT FROM FINISHED SURFACES. 1.6 CHANGE ORDER PROCEDURE A. THE CONTRACTOR CHANGE ORDERS MAY BE INITIATED BY THE OWNER AND/ OR THE CONTRACTOR INVOLVED. THE CONTRACTOR, UPON VERBAL REQUEST FROM THE OWNER SHALL PREPARE A WRITTEN PROPOSAL DESCRIBING THE CHANGE IN WORK OR MATERIALS AND ANY CHANGES IN THE CONTRACT AMOUNT AND PRESENT TO THE OWNER WITHIN 72 HOURS FOR APPROVAL. SUBMIT REQUESTS FOR SUBSTITUTIONS IN THE FORM AND IN ACCORDANCE WITH PROCEDURE REQUIRED FOR CHANGE ORDER PROPOSALS. ANY CHANGES IN SCOPE OF WORK OR MATERIALS WHICH ARE PERFORMED BY THE CONTRACTOR WITHOUT WRITTEN CHANGE ORDER AS DESCRIBED AND APPROVED BY THE OWNER SHALL PLACE FULL RESPONSIBILITY OF THESE ACTIONS ON THE CONTRACTOR. 1.7 RELATED DOCUMENTS AND COORDINATION A. GENERAL CARPENTRY, ELECTRICAL AND ANTENNA DRAWINGS ARE INTERRELATED. IN PERFORMANCE OF THE WORK, THE CONTRACTOR MUST REFER TO ALL DRAWINGS. ALL COORDINATION TO BE RESPONSIBILITY OF THE CONTRACTOR. 1.8 SHOP DRAWINGS A. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AS REQUIRED AND LISTED IN THESE SPECIFICATIONS TO THE OWNER FOR APPROVAL. B. ALL SHOP DRAWINGS SHALL BE REVIEWED, CHECKED AND CORRECTED BY CONTRACTOR PRIOR TO SUBMITTED TO THE OWNER. 1.9 PRODUCTS AND SUBSTITUTIONS A. SUBMIT 3 COPIES OF EACH REQUEST FOR SUBSTITUTION. IN EACH REQUEST IDENTIFY THE PRODUCT OR FABRICATION OR INSTALLATION METHOD TO BE REPLACED BY THE SUBSTITUTION. INCLUDE RELATED SPECIFICATION SECTION AND DRAWING NUMBERS AND COMPLETE DOCUMENTATION SHOWING COMPLIANCE WITH THE REQUIREMENTS FOR SUBSTITUTIONS. B. SUBMIT ALL NECESSARY PRODUCT DATA AND CUT SHEETS WHICH PROPERLY INDICATE AND DESCRIBE THE ITEMS, PRODUCTS AND MATERIALS BEING INSTALLED. THE CONTRACTOR SHALL, IF DEEMED NECESSARY BY THE OWNER SUBMIT ACTUAL SAMPLES TO THE OWNER FOR APPROVAL IN LIEU OF CUT SHEETS. 1.10 QUALITY ASSURANCE A. ALL SHALL BE IN ACCORDANCE WITH APPLICATION LOCAL, STATE AND FEDERAL REGULATIONS. THESE SHALL INCLUDE BUT NIT BE LIMITED TO THE LATEST VERSION OF THE FOLLOWING: • ANSI TIA/EIA — 222 — G • 2009 INTERNATIONAL BUILDING CODE • BUILDING OFFICIALS AND CODE ADMINISTRATORS (BOCA) 1990 • NATIONAL ELECTRICAL CODE (NEC) WITH LOCAL AMENDMENTS 2009 • UNDERWRITER LABORATORIES APPROVED ELECTRICAL PRODUCTS • AMERICAN INSTITUTE OF STEEL CONSTRUCTION • SPECIFICATIONS (AISC) • LIFE SAFETY CODE NFPA — 101-1990 1.11 ADMINISTRATION A. BEFORE THE COMMENCEMENT OF ANY WORK, THE CONTRACTOR WILL ASSIGN A PROJECT MANAGER WHO WILL ACT AS A SINGLE POINT OF CONTRACT FOR ALL PERSONNEL INVOLVED IN THIS PROJECT. THIS PROJECT MANAGER WILL DEVELOP A MASTER SCHEDULE FOR THE PROJECT WHICH WILL BE SUBMITTED TO THE OWNER PRIOR TO THE COMMENCEMENT OF ANY WORK. B. SUBMIT A BAR LIKE PROGRESS CHART NOT MORE THAN 3 DAYS AFTER THE DATE ESTABLISHED FOR COMMENCEMENT OF THE WORK ON THE SCHEDULE, INDICATING A TIME BAR FOR EACH MAJOR CATEGORY OR UNIT OF WORT{ TO BE PERFORMED AT SITE, PROPERLY SEQUENCED AND COORDINATED WITH OTHER ELEMENTS IN ADVANCE OF THE DATE ESTABLISHED FOR SUBSTANTIAL COMPLETION OF THE WORK. C. PRIOR TO COMMENCING CONSTRUCTION, THE OWNER SHALL SCHEDULE AN ON—SITE MEETING WITH ALL MAJOR PARTIES. THIS WOULD INCLUDE (THOUGH NOT LIMITED TO) THE OWNER, PROJECT MANAGER, CONTRACTOR, LAND OWNER REPRESENTATIVE, LOCAL TELEPHONE COMPANY, TOWER ERECTION FOREMAN (IF SUBCONTRACTED). D. CONTRACTOR SHALL BE EQUIPPED WITH SOME MEANS OF CONSTANT COMMUNICATIONS, SUCH AS A MOBILE PHONE OR A BEEPER. THIS EQUIPMENT WILL NOT BE SUPPLIED BY THE OWNER, NOR WILL WIRELESS SERVICE BE ARRANGED. E. DURING CONSTRUCTION, CONTRACTOR MUST ENSURE THAT EMPLOYEES AND SUBCONTRACTORS WILL WEAR HARD HATS AT ALL TIMES. CONTRACTOR WILL COMPLY WITH ALL WPCS SAFETY REQUIREMENTS IN THEIR AGREEMENT. F. CONTRACTOR MUST PROVIDE WRITTEN DAILY UPDATES ON SITE PROGRESS TO THE OWNER. G. A COMPLETE INVENTORY OF CONSTRUCTION MATERIALS AND EQUIPMENT IS REQUIRED PRIOR TO START OF CONSTRUCTION. H. NOTIFY THE OWNER / PROJECT MANAGER IN WRITING NO LESS THAN 48 HOURS IN ADVANCE OF CONCRETE POURS, TOWER ERECTIONS, AND EQUIPMENT CABINET PLACEMENTS. 1.12 INSURANCE AND BONDS A. CONTRACTOR AT THEIR OWN EXPENSE CARRY AND MAINTAIN FOR THE DURATION OF THE PROJECT ALL INSURANCE AS REQUIRED AND LISTED AND SHALL NOT COMMENCE WITH THEIR WORK UNTIL THEY HAVE PRESENTED AN ORIGINAL CERTIFICATE OF INSURANCE STATING ALL COVERAGE TO THE OWNER. REFER TO THE MASTER AGREEMENT FOR REQUIRED INSURANCE LIMITS. B. THE OWNER SHALL BE NAMED AS AN ADDITIONAL INSURED ON ALL POLICIES. C. CONTRACTOR MUST PROVIDE PROOF OF INSURANCE. DIVISION 2 -- SITE WORK AND DRAINAGE 1.1 WORK INCLUDED: REFER TO THE SURVEY AND SITE PLAN FOR WORK INCLUDED. 1.2 RELATED WORK B. INSTALLATION OF ANTENNA SUPPORT SYSTEM 1.5 SEQUENCING A. CONFIRM SURVEY STAKES AND SET ELEVATION STAKES PRIOR TO ANY CONSTRUCTION. B. IF REQUIRED, GRADE, SEED, FERTILIZED AND MULCH DISTURBED AREAS IMMEDIATELY AFTER BRINING THE SITE AND ACCESS ROAD TO BASE COURSE ELEVATION. WATER TO ENSURE GROWTH. C. REMOVE GRAVEL FROM TEMPORARY CONSTRUCTION ZONE. 1.7 WARRANTY A. IN ADDITION TO THE WARRANTY ON ALL CONSTRUCTION COVERED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL REPAIR ALL DAMAGE TO SURROUNDING PROPERTY CAUSED BY CONSTRUCTION. B. DISTURBED AREAS WILL REFLECT GROWTH ON NEW GRASS COVER PRIOR TO FINAL INSPECTION. 2.1 MATERIALS A. SITE MATERIALS: FILL MATERIAL — ACCEPTABLE SELECT FILL SHALL BE IN ACCORDANCE WITH LOCAL DEPARTMENT OF HIGHWAY AND PUBLIC TRANSPORTATION STANDARDS SPECIFICATION. B. SOIL STABILIZER FABRIC SHALL BE MIRAFI — 500X. C. NON—STRUCTURAL SITE CONCRETE SHALL BE 3000 PSI BREAKING STRENGTH AT 28 DAYS. COMPLY WITH GENERAL PROVISIONS OF DIVISION 3 CONCRETE SPECIFICATIONS. 2.2 EQUIPMENT A. COMPACTING SHALL BE ACCOMPLISHED BY MECHANICAL MEANS. LARGER AREA SHALL BE COMPACTED BY SHEEPS FOOT, VIBRATOR OR RUBBER TIRED ROLLERS WEIGHING AT LEAST FIVE TONS. WATER TREATMENT MAY REQUIRED TO OBTAIN COMPACTION. SMALLER ARES SHALL BE COMPACTED BY POWER—DRIVE, HAND HELD TAMPERS. 3.1 INSPECTIONS LOCAL BUILDING INSPECTION SHALL BE NOTIFIED NO LESS THAN 48 HOURS IN ADVANCE OF CONCRETE POURS. 3.2 PREPARATION A. PRIOR TO OTHER EXCAVATION AND CONSTRUCTION EFFORTS GRUB ORGANIC MATERIAL TO A MINIMUM OF SIX INCHES BELOW ORIGINAL GROUND LEVEL. B. UNLESS OTHERWISE INSTRUCTED BY THE OWNER, REMOVE TREES, BRUSH AND DEBRIS FORM THE PROPERTY TO AN AUTHORIZED LANDFILL. C. PRIOR TO PLACEMENT OF FILL OR BASE MATERIALS, REMOVE SOFT SPOTS AND COMPACT TO 85% STANDARD PROCTOR. D. WHERE UNSTABLE SOIL CONDITIONS ARE ENCOUNTERED, LINE THE GRUBBED AREAS WITH STABILIZER MAT PRIOR TO REPLACEMENT OF FILL OR BASE MATERIAL. T } -Mobil 7668 WARREN PKY, STE 100 FRISCO, TX 75034 PRODUCED BY: Sf.IJ SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 BY: BR NCH COMMUN/CAT/ONS, LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 949-4551 SITE NAME: 'WEST LITTLE ROCK IBTS NUMBER: AR01215A :SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 PROJECT NUMBER: AR01215A ENGINEER: 9T A� ,, a ARKANSAS • r LtcE� SE ] �I�C�>�E�ssf AL ENGIN ER Ir No. 16564 h'IW R PE #16564 EXP 12/31/17 NO DATE DESCRIPTION BY A 10 24 14 PRELIM ISSUE NDP B 3,/3/15 PRELIM ISSUE JWM C 3/10/15 PRELIM ISSUE JWM D 3/17/15 PRELIM ISSUE JWM E 3/30 15 PRELIM ISSUE JWM F 4 7 15 PRELIM ISSUE JWM 0 4/8/15 CONST ISSUE JWM 1 9 13 15 1 CONST ISSUE JWM 2 5/18/16 CONST ISSUE JWM BEET TITLE: GENERAL NOTES SHEET GN1B�nCJWM PROJECT ►: AR01215A 2 3.2 PREPARATION A. PRIOR TO OTHER EXCAVATION AND CONSTRUCTION EFFORTS GRUB ORGANIC MATERIAL TO A MINIMUM OF SIX INCHES BELOW ORIGINAL GROUND LEVEL. B. UNLESS OTHERWISE INSTRUCTED BY THE OWNER, REMOVE TREES, BRUSH AND DEBRIS FORM THE PROPERTY TO AN AUTHORIZED LANDFILL, C. PRIOR TO PLACEMENT OF FILL OR BASE MATERIALS, REMOVE SOFT SPOTS AND COMPACT TO 85% STANDARD PROCTOR. D. WHERE UNSTABLE SOIL CONDITIONS ARE ENCOUNTERED, LINE THE GRUBBED AREAS WITH STABILIZER MAT PRIOR TO REPLACEMENT OF FILL OR BASE MATERIAL. 2. FAA - FEDERAL AVIATION ADMINISTRATION ADVISORY CIRCULAR AC 70/7460-IH,BS OBSTRUCTION MARKING AND LIGHTING. 3. FCC - FEDERAL COMMUNICATIONS COMMISSION RULES AND REGULATIONS FORM 715, OBSTRUCTION MARKING NAD LIGHTING SPECIFICATIONS FOR ANTENNA STRUCTURES. 4. AISC - AMERICAN INSTITUTE OF STEEL CONSTRUCTION SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. 5. NEC - NATIONAL ELECTRICAL CODE - ON TOWER LIGHTING KITS. 3.3 INSTALLATION A -1q72 4f 14 PRELIM ISSUE 6. UL - UNDERWRITER'S LABORATORIES APPROVED ELECTRICAL PRODUCTS. A. CLEAR EXCESS SPOILS, IF ANY, FROM JOB SITE AND DO NOT SPREAD BEYOND THE C 3/10/15 PRELIM ISSUE 7. IN ALL CASES, PART 77 OR THE FAA RULES AND PARTS 17 AND 22 OF THE D 3/17/15 PRELIM ISSUE LIMITS OF THE OWNERS LEASE PROPERTY UNLESS AUTHORIZED BY PROJECT E 3/30/15 PRELIM ISSUE FCC RULES ARE APPLICABLE AND IN THE EVENT OF CONFLICT, SUPERSEDE ANY F 4/7/15 PRELIM ISSUE MANAGER, IN WRITING. 0 4 8 15 CONST ISSUE OTHER STANDARDS OD SPECIFICATIONS. B. THE FINISH GRADE, INCLUDING TOP SURFACE COURSE, SHALL EXTEND TO LEASE 2 5 1$ 16 CONST ISSUE JWM :SHEET TITLE: GENERAL NOTES LINE. PROJECT AR01215A 8. 1990 LIFE SAFETY CODE NFPA - 101 3.4 FIELD QUALITY CONTROL 3.3 INSTALLATION A. COMPACTION SHALL BE 90% MAXIMUM DENSITY IN ACCORDANCE WITH ASTM A. THE ACCESS ROAD SHALL BE BROUGHT TO BASE COURSE ELEVATION PRIOR TO D-1557 FOR SITE WORK AND 95% UNDER PLATFORM AREA. SETTLEMENT WILL BE FOUNDATION CONSTRUCTION. EXCAVATED AND REFILLED AT CONTRACTOR'S EXPENSE. B. AVOID CREATING DEPRESSIONS WHERE WATER MAY POND. C. THE CONTRACT INCLUDES ALL NECESSARY GRADING, BANKING, DITCHING AND 3.5 QUALITY ASSURANCE UNLESS OTHERWISE INDICATED, COVERING TWO INCHES OF SURFACE COURSE. ALL ROADS OR ROUTES UTILIZED FOR ACCESS TO THE SITE, COMMENCING AT THE POINT OF INTERSECTION WITH THE NEAREST PUBLIC THOROUGHFARE, ARE INCLUDED A. ALL STEEL MATERIALS UTILIZED IN CONJUNCTION WITH THIS SPECIFICATION WILL BE IN SCOPE UNLESS OTHERWISE NOTED. GALVANIZED OR STAINLESS STEEL. WEIGHT OF ZINC COATING ON THE FABRIC SHALL D. WHEN APPROVING A EXISTING ACCESS ROAD, GRADE THE EXISTING ROAD TO NOT BE LESS THAN 12 OUNCES PER SQUARE FOOT OF MATERIAL COVERED. POSTS REMOVE ANY ORGANIC MATTER AND SMOOTH THE SURFACE BEFORE PLACING FILL SHALL BE HOT -DIPPED IN GRADE E ZINC, 1.8 OUNCES PER SQUARE FOOT. E. OR STONE. PLACE FILL OR STONE IN 6 INCH MAXIMUM LIFTS AND COMPACT BEFORE PLACING NEXT LIFT. 3.6 APPLICABLE STANDARDS F. THE FINISH GRADE, INCLUDING TOP SURFACE COURSE, SHALL EXTEND A MINIMUM OF ONE FOOT BEYOND THE SITE FENCE AND SHALL COVER THE AREA AS A. ASTM -A120 SPECIFICATION FOR PIPE, STEEL BLACK AND HOT -DIPPED ZINC COATED G. INDICATED. RIP RAP SHALL APPLIED THE SIDES SLOPES OF ALL FENCED SITE AREAS, (GALVANIZED) WELDED AND SEAMLESS FOR ORDINARY USES. T PARKING ARES AND TO ALL OTHER SLOPES GREATER THAN 2 N B. ASTM -123 ZINC (HOT -DIP GALVANIZED) COATING ON IRON AND STEEL PRODUCTS. H. RIP RAP SHALL BE APPLIED TO THE SIDES OF SIDES OF DITCHES05 DRAINAGE C. ASTM -A153 STANDARD SPECIFICATION FOR ZINC COATING (HOT -DIP) ON IRON AND SWALES AS INDICATED ON PLANS. STEEL HARDWARE. I. RIP RAP ENTIRE DITCH FOR SIX FEET IN ALL DIRECTIONS AT CULVERT OPENINGS. D. ASTM -A392 SPECIFICATION FOR ZINK-COATED STEEL CHAIN LINK FENCE FABRIC. J. SEED, FERTILIZER AND STRAW COVER SHALL BE APPLIED TO ALL OTHER DISTURBED E. ASTM -A491 SPECIFICATION FOR ALUMINUM -COATED CHAIN LINK FENCE FABRIC. AREAS AND DITCHES, DRAINAGE. SWALES, NOT OTHERWISE RIP -RAPPED. F. ASTM -A525 STANDARD SPECIFICATION FOR STEEL SHEET ZINC COATED (GALVANIZED) K. UNDER NO CIRCUMSTANCES WILL DITCHES, SWALES OR CULVERTS BE PLACED SO BY THE HOT -DIPPED PROCESS. THEY DIRECT WATER TOWARDS, OR PERMIT STANDING WATER IMMEDIATELY ADJACENT G. ASTMOA570 SPECIFICATION FOR HOT -ROLLED CARBON STEEL SHEET AND STRIP TO SITE. IF OWNER DESIGNS OR ELEVATIONS CONFLICT WITH THIS GUIDANCE ADVISE STRUCTURAL QUALITY. THE OWNER IMMEDIATELY, IN WRITING. H. ASTM -A585 SPECIFICATION FOR ALUMINUM COATED STEEL BARBED WIRE. L. IF DITCH LIES WITH SLOPES GREATER THAN TEN PERCENT, MOUND DIVERSIONARY HEADWALLS IN THE DITCH AND RIP RAP THE UPSTREAM SIDE OF THE HEADWALL AS EXCAVATE POST HOLES WITH MECHANICAL AUGER EQUIPMENT. EXCAVATE POST HOLES WELL AS THE DITCH FOR SIX FEET ABOVE THE CULVERT ENTRANCE. PER CONSTRUCTION DOCUMENTS. CONFIRM PROPER DEPTH AND DIAMETER OF POST M. SEED AND FERTILIZER SHALL BE APPLIED TO SURFACE CONDITIONS WHICH WILL HOLE EXCAVATIONS. ENCOURAGE ROOTING. RAKE AREAS TO BE SEEDED TO EVEN THE SURFACE AND LOOSEN THE SOIL. SPECIAL CONSTRUCTION TOWER & ANTENNA " SPRODUCERO DIRECTIONS IN TWICE THE QUANTITY RECOMMENDED BY THE SEED INSTALLATION 0. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE GROWTH OF SEEDED AND F LANDSCAPED AREAS BY WATERING UP TO THE POINT OF RELEASE FROM THE CONTRACT. CONTINUE TO REWORK BARE AREAS UNTIL COMPLETE COVERAGE IS 1.1 WORK INCLUDED OBTAINED. A. IF REQUIRED, ERECT FURNISHED TOWER. " B. GROUND TOWER TEMPORARILY DURING ERECTION. GROUNDING SHOULD INCLUDE BASE(S) AND ANCHORS C. IF REQUIRED, INSTALL THREE (3) SIDE ARMS, CONSISTING OF OWNER REPRESENTATIONS. D. INSTALL ANTENNAS AS INDICATED ON DRAWINGS AND OWNER SPECIFICATION. E. INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS. F. INSTALL FURNISHED GALVANIZED STEEL WAVE GUIDE LADDER. G. INSTALL WAVE GUIDE BRIDGE AS INDICATED ON DRAWING. H. SUPPLY AND INSTALL ONE INSULATED GROUND BAR AT EQUIPMENT CABINET. I. SUPPLY AND INSTALL GROUNDING KITS WITH LONG BARREL DOUBLE CRIMPED COMPRESSION LUGS. (SIM. TO ANDREW- 223700TBD OF APPROVED EQUAL) ATOP TOWER BASE BEFORE ENTERING THE EQUIPMENT. GROUNDING LEADS TO BE CONNECTED TO INSULATED GROUND BAR. A. ASSIST OWNER TECHNICIANS IN PERFORMING SWEEP TEST OF INSTALLED COAX. f B. CONCRETE PIERS FOR FOUNDATIONS SHALL BE DRILLED AND POURED ON THE SAME DAY. 2.2 RELATED WORK 2.3 REQUIREMENTS OF REGULATOR AGENCIES A. FURNISH U.L. LISTED EQUIPMENT WHERE SUCH LABEL IS AVAILABLE, INSTALL IN CONFORMANCE WITH U.L. STANDARDS WHERE APPLICABLE. B. INSTALL ANTENNA, ANTENNA CABLES AND GROUNDING SYSTEM IN ACCORDANCE WITH DRAWINGS AND SPECIFICATION IN EFFECT AT PROJECT LOCATION AND RECOMMENDATIONS OF STATE AND LOCAL BUILDING CODES, SPECIAL CODES HAVING JURISDICTION OVER SPECIFIC PORTIONS OF WORK. THIS INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: 1. EIA - ELECTRONIC INDUSTRIES ASSOCIATION TIA-EIA-222-G. STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWERS AND ANTENNA SUPPORTING STRUCTURES. 3.5 PROTECTION A. PROTECT SEEDED AREAS FROM EROSION BY SPREADING STRAW TO A UNIFORM LOOSE DEPTH OF 1-2 INCHES, STAKE AND TIE DOWN AS REQUIRED. USE OF EROSION CONTROL MESH OR MULCH NET WILL BE AN ACCEPTABLE ALTERNATE, B. ALL TREES PLACED IN CONJUNCTION WITH A LANDSCAPE CONTRACT WILL BE WRAPPED, TIED WITH HOSE PROTECTION WIRE AND SECURED TO 2 1 INCH x 2 INCH x 4 FOOT STEEL ANGLE EXTENDING TWO FEET INTO THE GROUND ON FOUR SIDES OF THE TREE. C. ALL EXPOSED AREAS SHALL BE PROTECTED AGAINST WASHOUTS AND SOIL EROSION. • Mobil 7668 WARREN PKY, STE 100 FRISCO, TX 75034 WCED BY: a SPEC6ALTY TELECOMMUNICATIONS SERJICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CRY, OK 73114 (405) 753-7167 BY: BR NCH COMMU/V/CAT/ONS,LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 949-4551 SITE NAME: 'WEST LITTLE ROCK 13TS NUMBER: AR01215A SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 PROJECT NUMBER: AR01215A ENGINEER:/// �'+•`` +1 ARKANSAS -i //tICLE S�� y . ' 1� UESWONAL ENGINEER �%, �! No. 16564 NNA, ;�';" �I • V �r6���wPE #16564P 12/31/17 IVO DATE DESCRIPTION BY A -1q72 4f 14 PRELIM ISSUE NDP B 3/3/15 PRELIM ISSUE JWM C 3/10/15 PRELIM ISSUE JWM D 3/17/15 PRELIM ISSUE JWM E 3/30/15 PRELIM ISSUE JWM F 4/7/15 PRELIM ISSUE JWM 0 4 8 15 CONST ISSUE JWM 1 9/13 15 CONST ISSUE JWM 2 5 1$ 16 CONST ISSUE JWM :SHEET TITLE: GENERAL NOTES SHEET #: GN2 PROJECT AR01215A 2 Bon C�WM 11'-0" �x x J CCD PROPOSED METER x 0 I o I a x 0 5--0- 37'-0" 12'-0" 4'-0" 6'-0" PROPOSED 10'-0" T -MOBILE ICE BRIDGE, RE: SHEET C3 PROPOSED T -MOBILE 10'-O"x12'-0" CONCRETE o EQUIPMENT PAD AND int LEASE AREA, RE: 2/C1 / PROPOSED T -MOBILE SSC CABINET o `I PROPOSED 6'-0" T -MOBILE ICE BRIDGE, RE: SHEET C3*EXISTING EXISTING VERIZON CONCRETE PAD 0CE 150' MONOPOLE 9'-0" EXISTING H -FRAME X x x x x 1 6'-0" 9'-0" _ 3'-0' OVERALL SITE PLAN SCALE n 5 .0' 20' EXISTING GENERATOR 4'-0" BY } iv I B 3/3/15 PRELIM ISSUE JWM C 3/10/15 PRELIM ISSUE 0 I _ O -1 SSC o � N x N / � _ v 1 9/l3 15 1 CONST ISSUE + + x JWM 0 ~ EXISTING 12'-0" I CK05 JWM WOOD GATE 0 I to N 00 M DISCONNECT 0 EXISTING 8'-0" I 0 ''1 WOOD FENCE I T -MOBILE PPC N x CABINET, RE: E3 CCD PROPOSED METER x 0 I o I a x 0 5--0- 37'-0" 12'-0" 4'-0" 6'-0" PROPOSED 10'-0" T -MOBILE ICE BRIDGE, RE: SHEET C3 PROPOSED T -MOBILE 10'-O"x12'-0" CONCRETE o EQUIPMENT PAD AND int LEASE AREA, RE: 2/C1 / PROPOSED T -MOBILE SSC CABINET o `I PROPOSED 6'-0" T -MOBILE ICE BRIDGE, RE: SHEET C3*EXISTING EXISTING VERIZON CONCRETE PAD 0CE 150' MONOPOLE 9'-0" EXISTING H -FRAME X x x x x 1 6'-0" 9'-0" _ 3'-0' OVERALL SITE PLAN SCALE n 5 .0' 20' EXISTING GENERATOR 4'-0" 12'-0" (LEASE AREA) _0- 8'-7 1/2" 2'-3 3/8" IL BY PROPOSED GPS ANTENNA, RE: 4/C3/ PROPOSED T -MOBILE iv I B 3/3/15 PRELIM ISSUE JWM C 3/10/15 PRELIM ISSUE 0 I _ O -1 SSC N E 3/30/15 1 PRELIM ISSUE N x CABINET JWM _ v 1 9/l3 15 1 CONST ISSUE + + x JWM 0 SHEET #: C 1AR01215A o I CK05 JWM I PROPOSED �+ ++ •� to N DISCONNECT 0 I 0 ''1 0 I T -MOBILE PPC N x 12'-0" (LEASE AREA) _0- 8'-7 1/2" 2'-3 3/8" IL 10'-0" 4'-0" PROPOSED T -MOBILE 10'-0"x12'-0" CONCRETE EQUIPMENT PAD AND LEASE AREA TRUE NORTH TRUE NORTH (O MAG E) ENLARGED SITE PLAN (°MAG2E, SCALE: 0' 1' 5' 10' 15' T • . Mobile - 7668 WARREN PKY, STE 100 FRISCO, TX 75034 PRODUCED BY: SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CRY, OK 73114 (405) 753-7167 PRODUCED BY: BR NCH COMMUN/CAT/ONS,LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 949-4551 SITE NAME: 'WEST LITTLE ROCK 13TS NUMBER: AR01215A :SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 PROJECT NUMBER: AR01215A KATE OZ' f 4 ENGINEER 'r► v No. 16564 AL +� =ny � N R �. G8�16 PE #16564 I�%P 12/31/17 tq0 DATE DESCRIPTION BY PROPOSED GPS ANTENNA, RE: 4/C3/ PROPOSED T -MOBILE iv I B 3/3/15 PRELIM ISSUE JWM C 3/10/15 PRELIM ISSUE JWM _ O -1 SSC N E 3/30/15 1 PRELIM ISSUE JWM F 4 7115PRELIM CABINET JWM _ JWM 1 9/l3 15 1 CONST ISSUE + + 2 5/18/16 CONST ISSUE JWM SHEET TITLE: OVERALL AND ENLARGED SITE PLANS SHEET #: C 1AR01215A Pf2QJECT #: w CK05 JWM PROPOSED �+ ++ •� N DISCONNECT PROPOSED �•" 0 T -MOBILE PPC CABINET, RE: E3 s � + r PROPOSED ", • . . H -FRAME ATTACHED TO CONCRETE PAD, f •�++," RE: 3/S1 }+ 10'-0" 4'-0" PROPOSED T -MOBILE 10'-0"x12'-0" CONCRETE EQUIPMENT PAD AND LEASE AREA TRUE NORTH TRUE NORTH (O MAG E) ENLARGED SITE PLAN (°MAG2E, SCALE: 0' 1' 5' 10' 15' T • . Mobile - 7668 WARREN PKY, STE 100 FRISCO, TX 75034 PRODUCED BY: SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CRY, OK 73114 (405) 753-7167 PRODUCED BY: BR NCH COMMUN/CAT/ONS,LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 949-4551 SITE NAME: 'WEST LITTLE ROCK 13TS NUMBER: AR01215A :SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 PROJECT NUMBER: AR01215A KATE OZ' f 4 ENGINEER 'r► v No. 16564 AL +� =ny � N R �. G8�16 PE #16564 I�%P 12/31/17 tq0 DATE DESCRIPTION BY A 10/24/14 PRELIM ISSUE NDP B 3/3/15 PRELIM ISSUE JWM C 3/10/15 PRELIM ISSUE JWM D j 3/17/15 PRELIM ISSUE JWM E 3/30/15 1 PRELIM ISSUE JWM F 4 7115PRELIM ISSUE JWM 0 4/8/15 CONST ISSUE JWM 1 9/l3 15 1 CONST ISSUE JWM 2 5/18/16 CONST ISSUE JWM SHEET TITLE: OVERALL AND ENLARGED SITE PLANS SHEET #: C 1AR01215A Pf2QJECT #: HY: non CK05 JWM THESE DRAWINGS ARE NOT INTENDED TO REFLECT THE STRUCTURAL INTEGRITY OF THE TOWER. THE PROPOSED ANTENNAS AND TRANSMISSION LINES SHOWN ARE REPRESENTATIVE IN NATURE AND DO NOT REFLECT THE ACTUAL CONFIGURATIONS REQUIRED. THE CONTRACTOR SHALL REFER TO THE STRUCTURAL ANALYSIS OF THIS TOWER SITE FOR THE APPROVED LOCATION AND CONFIGURATION OF ALL ANTENNAS AND TRANSMISSION LINES. ALL ANTENNAS MUST BE MOUNTED AND THE TRANSMISSION LINES CONFIGURED IN STRICT ACCORDANCE WITH THE STRUCTURAL ANALYSIS. (TOWER BY OTHERS) tLtV. = IMJ EXISTING ANTENNAS T—MOBILE ANTENNAS Ems' PROPOSED T—MOBILE ANTENNAS EXISTING 150' MONOPOLE 2/C2 PROPOSED: (3) NEIN ANTENNAS (1) NEW RAYCAP (3) NEW FRIJ'S (1) NEW PLATFORM MOUNT (1) NEW HYBRID CABLE 3/C2 1. . PROPOSED TOWER ELEVATION I SCALE: N.T.S. T—MOBILE ANTENN"� TYPICAL OF (3) PROPOSED VALM01 PRO PART #SNPB- ANTENNA MOUNT PROPOSED RRU'S CABLE NOTE: 1. COAX CABLE ATTACHMENTS SHOULD FOLLOW MANUFACTURER SPECIFICATIONS FOR ATTACHMENT AND HANGING SPECS. 2. ROUTE COAX UP TOWER PER STRUCTURAL ANALYSIS. PROPOSED COAX: (1) HYBRID COAX CABLE EXISTING MONOPOLE J 3 TRANSMISSION LINE DIAGRAM SCALE: N.T.S. 1 ALPHA AZIMUTH 0 A-1 LTE 700/UMTS PCS/LTE AWS B-1 700/UMTS /LTE AWS ZETA LTH 120' TRUE NORTH r7 ANTENNA AZIMUTH PLAN (0.MAG SCALE: N.T.S. 1/2" COAX JUMPE FROM TMA TO ANT JUMPER SUPPORT STAND—OFF WITH CUSHION HANGERS OR STEEL BRACKE WITH SNAP—IN HANGER PROPOSED T—MOBILE ANTENNA 2 3/8" O.D. PIPE COAX CABLE 11 L5+ #6 AWG GREEN I INSULATED GROUND CABLE FROM RRU TO GROUND BAR A ANTENNA MOUNT DETAIL 'T SCALE: N.T.S. • ,Mobll 7668 WARREN PKY, STE 100 FRISCO, TX 75034 PRODUCED BY: 5 SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 ED BY: BR NCH COi "UN/CAT/ONS,LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 949-4551 :SITE NAME: 'WEST LITTLE ROCK 13TS NUMBER: A R01215A :SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 PROJECT NUMBER: AR01215A ySATE OF F____Z� ENGINEER +� O No. 16564 ��►711 R PE #1656_41650_'l 2/31/17 INO DATE DESCRIPTION BY A 10/24/141 PRELIM ISSUE NDP B 3/3/15 PRELIM ISSUE JWM C 3/10./15 PRELIM ISSUE JIWM ❑ 3j17/15 1 PRELIM ISSUE JWM E V30/15 1 PRELIM ISSUE JWM F 4/7/15 PRELIM ISSUE JWM 0 4/8 15 CONST ISSUE JWM 1 2Z13/15 CONST ISSUE JWM 2 5418,/116 CONST ISSUE JWM 13HEET TITLE: ANTENNA ORIENTATION, MOUNT AND SCHEDULE SHEET: C ^ LJ PROJECT #: AR0 /1 L BY: non JCKD: KD: JWM WAVEGUIDE BRIDGE ISOMETRIC SCALE: N.T.S. (1) GPS ANTENNA (PROVIDED BY OWf GPS MOUNTING PIF NnTr,q. COORDINATE GPS ANTENNA LOCATION WITH CONSTRUCTION MANAGER. MAINTAIN MINIMUM BEND RADIUS ON COAX CABLE AT ALL TIMES. ENSURE LOCATION OF GPS ANTENNA ALLOWS FOR CLEAR VIEW OF SOUTHERN HORIZON. GPS MOUNT TO BE PROVIDED BY OWNER. GPS ANTENNA TO BE INSTALLED BY CONTRACTOR. GPS ANTENNA DETAIL 'T SCALE: N.T.S. SEAL VOID BETWEEN PIPE AND CABLE 3/8"0 COAX CABLE f7 WAVEGUIDE BRIDGE SECTION L SCALE: N.T.S. ' ALT FABRICATION DATE DESCRIPTION GUIDE BRIDGE KIT A 10 24/14 PRELIM ISSUE PPROVED EQUAL LEGEND 3/3/15 PRELIM AR01215A_X_X_X_X_X JWM C 3/10/15 PRELIM ISSUE JWM D 3/17J 15 PRELIM ISSUE LD E 3/30/15 PRELIM ISSUE JWM F 4Z7/15 PRELIM ISSUE JWM - LTE 700 4 8/15 CONST ISSUE JiWM 1 .9/13/15 CONST ISSUE JWM 2 B - LTE PCS JWM !SHEET TITLE: WAVEGUIDE DETAILS SHEET 07 C32 PROJECT #: AR01215A : 2 BY: non L - LTE AWS P - UMTS PCS U - UMTS AWS =ZE SUPPORT KIT G - GSM PCS COAX CABLES. ATTACH ACTUATOR NUMBER STAINLESS STEEL -IN HANGERS ANTENNA NUMBER SECTOR LETTER CANDIDATE LETTER SITE NUMBER ao _Nqq gam_ dd N N AED GRADE as �1 PSI RETE PIER RET ACTUATOR NAMING CONVENTION %J SCALE: N.T.S. VENDOR: I • •Mobile 7666 WARREN PKY, STE 100 FRISCO. TX 75034 PRODUCED BY: 5�5 SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SURE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 UCED BY: BR NCH COMMUN/CAT/ONS, LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (91B) 949-4551 :SITE NAME: 'WEST LITTLE ROCK (BTS NUMBER: AR01215A ,SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 (PROJECT NUMBER: AR01215A SZ ATB OF i►, ENGINEER !► L O No. 16564 hN R . �' ��16 PE #16564 P 12/31/17 NO DATE DESCRIPTION BY A 10 24/14 PRELIM ISSUE NDP $ 3/3/15 PRELIM ISSUE JWM C 3/10/15 PRELIM ISSUE JWM D 3/17J 15 PRELIM ISSUE JWM E 3/30/15 PRELIM ISSUE JWM F 4Z7/15 PRELIM ISSUE JWM 0 4 8/15 CONST ISSUE JiWM 1 .9/13/15 CONST ISSUE JWM 2 15/18/16 1 CONST ISSUE JWM !SHEET TITLE: WAVEGUIDE DETAILS SHEET 07 C32 PROJECT #: AR01215A : 2 BY: non CKO: JWM ANTENNA NOTES i. ANTENNA CONTRACTOR SHALL INSURE THAT ALL ANTENNA MOUNTING PIPES ARE PLUMB. 2. COAXIAL FEEDER & FIBER LENGTHS INDICATED ARE APPROXIMATE. 3. ANTENNA COAXIAL FEEDERS & ANTENNA JUMPERS SHALL BE COLOR CODED PER T -MOBILE REQUIREMENTS. IN ADDITION TO THE COLOR CODE IN THE ANTENNA KEY THE FOLLOWING CHECKER STRIPE SHALL BE ADDED TO EACH ANTENNA COAXIAL FEEDER & ANTENNA JUMPER. LTE 700 - RED -BLACK CHECKER STRIPE LTE PCS - RED -GREEN CHECKER STRIPE LTE AWS - YELLOW -BLACK CHECKER STRIPE UMTS PCS - RED -WHITE CHECKER STRIPE UMTS AWS - GREEN -WHITE CHECKER STRIPE GSM PCS - BLACK -WHITE CHECKER STRIPE 4. MULTI PORT ANTENNAS: TERMINATE UNUSED ANTENNA PORTS WITH CONNECTOR CAP & WEATHERPROOF THOROUGHLY. JUMPERS FROM TMA'S MUST TERMINATE TO OPPOSITE POLARIZATIONS IN EACH SECTOR. 5. CONTRACTOR MUST FOLLOW ALL MANUFACTURERS' RECOMMENDATIONS REGARDING THE INSTALLATION OF COAXIAL CABLES, CONNECTORS, AND ANTENNAS. 6. MINIMUM BEND RADIUS: LDF4-50A (1/2" HARD LINE) = 5" FSJ4-50B (1/2" SUPER FLEX) = 1 1/4" AVA5-50A (7/8" HARD LINE) = 10" AVA7-50A (1 5/8" HARD LINE) = 15" LDF7-50A (1 5/8" HARD LINE) = 20- 7. CONTRACTOR SHALL RECORD THE SERIAL SECTOR, AND POSITION OF EACH ACTUATOR INSTALLED AT THE ANTENNAS AND FURNISH THE INFORMATION TO T -MOBILE. 8. WEATHERPROOF ALL ANTENNA CONNECTORS WITH SELF AMALGAMATING TAPE. 9. ANTENNA CONTRACTOR SHALL PERFORM A "TAPE DROP" MEASUREMENT TO CONFIRM/VALIDATE ANTENNA CENTER LINE (ACL) HEIGHT. CONTRACTOR SHALL SUBMIT A COMPLETED HEIGHT VERIFICATION FORM TO THE CONSTRUCTION MANAGER. 10. ALL FIBER RUNS TO BE CONTAINED IN ONE COMMSCOPE HYBRID DC -FIBER CABLES (MODEL #ASU9325TYP01) FROM LOWER COVP TO UPPER COVP. HYBRID CABLES SHALL BE COLOR CODED PER T -MOBILE REQUIREMENTS. ANTENNA SCHEDULE SCALE: N.T.S. ANTENNA KEY STATUS ANTENNA NUMBER COLOR CODE (SEE NOTE 3) AZIMUTH (DEG) ANTENNA CENTERLINE ANTENNA VENDER PROPOSED ANTENNA MODEL # ELECTRICAL DOWNTILT MECHANICAL DOWNTILT BEAM WIDTH COAXIAL FEEDER HYBRID CABLE FEEDER TYPE SIZE LENGTH QUANTITY COLOR CODE PROPOSED A-1 LTE 700/LTE AWS/UMTS PCS RED 4/YB 0' 129' NOKIA FASB RAS TBD O' 65' BETA NOKIA (1) HYBRID CABLE GRAY 1 LTE AWS RED 3/YB RED 2/YB GAMMA NOKIA RED 1/YB RED 4/RW 129 UMTS PCS RED 3/RW RED 2/RW COVP RNSNDC-7771-PF-4B RED 1/RW RED 2/RB PROPOSED SECTOR LTE 700 RED 1/RB PROPOSED B-1 LTE 700/LTE AWS/UMTS PCS YELLOW 4/YB 120' 129' NOKIA FASB RAS TBD 0' 657 SHARED WITH ALPHA SECTOR GRAY 1 LTE AWS YELLOW 3/YB YELLOW 2/YB YELLOW 1/YB YELLOW 4/RW -- 170' UMTS PCS YELLOW 3/RW YELLOW 2/RW YELLOW 1/RW YELLOW 2/RB -.-- �- LTE 700 YELLOW 1/RB PROPOSED C-1 LTE 700/LTE AWS/UMTS PCS BLUE 4/YB 240' 129' NOKIA FASB RAS TBD 0' 65' SHARED WITH ALPHA SECTOR GRAY 1 LTE AWS UMTS PCS BLUE 3/YB BLUE 2/YB BLUE 1/YB BLUE 4/RW -- BLUE 3/RW BLUE 2/RW BLUE 1/RW BLUE 2/RB -- -- LTE 700 BLUE 1/RB COLOR CODING PROVIDED BY T -MOBILE .,Mobile - 7668 WARREN PKY, STE 100 FRISCO, TX 75034 DUCED BY: 5t5 SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 BY: BR NCH COMMUN/CAT/ONS, LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA. OKLAHOMA 74119 (916) 949-4551 'SITE NAME: 'WEST LITTLE ROCK BTS NUMBER: AR01215A ,SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 (PROJECT NUMBER: AR01215A 5l ATE dF �A ENGINEER 1 www �1 1. vQ No. 16564at PE #16564'raw 11P 12/31/17 NO DATE DESCRIPTION BY RRU & COVP KEY 10/24 14 PRELIM ISSUE NDP B A/3/15 PRELIM ISSUE VENDOR EQUIPMENT MODEL NO. EQUIP ENT OTY. STATUS SECTOR E 3/30/15 PRELIM ISSUE JWM ION 4/7/15 PRELIM ISSUE JWM ALPHA NOKIA RRU FRIJ 129' (1) PROPOSED BETA NOKIA RRU FRU 129' (1) PROPOSED GAMMA NOKIA RRU FRIJ 129 (1) PROPOSED MULTI RAYCAP COVP RNSNDC-7771-PF-4B 129' (1) PROPOSED SECTOR .,Mobile - 7668 WARREN PKY, STE 100 FRISCO, TX 75034 DUCED BY: 5t5 SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 BY: BR NCH COMMUN/CAT/ONS, LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA. OKLAHOMA 74119 (916) 949-4551 'SITE NAME: 'WEST LITTLE ROCK BTS NUMBER: AR01215A ,SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 (PROJECT NUMBER: AR01215A 5l ATE dF �A ENGINEER 1 www �1 1. vQ No. 16564at PE #16564'raw 11P 12/31/17 NO DATE DESCRIPTION BY A 10/24 14 PRELIM ISSUE NDP B A/3/15 PRELIM ISSUE JWM C 3/10/15 PRELIM ISSUE JWM D 3 17 15 PRELIM ISSUE JWM E 3/30/15 PRELIM ISSUE JWM F 4/7/15 PRELIM ISSUE JWM 0 4/8/15 CONST ISSUE JWM 1 9/13Z15 CONST ISSUE JWM 2 5/18/16 CONST ISSUE JWM 'SHEET TITLE: ANTENNA SCHEDULE SHEET: C PROJECT d: ARO 121 ^ L IBny: on CKD JWM NOTES: 1. SLAB TO BE LEVEL t1/4". 2. SLAB FOUNDATION DESIGNED ASSUMING ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF. 3. SLAB FOUNDATION DESIGNED ASSUMING MAXIMUM SOIL PLASTICITY INDEX OF 27 PER NCBC. 4. CONCRETE STRENGTH FOR FOUNDATION DESIGN SHALL BE A MINIMUM OF 3000 PSI AT 28 DAYS. 5. FOOTINGS TO EXTEND BELOW UNDISTURBED SOIL PER SITE SPECIFIC DESIGN. 6. REFER TO THE GENERAL NOTES FOR ADDITIONAL NOTES. N 1' 12'-0" TYPICAL EQUIPMENT FOUNDATION PLAN — 0 0 3/4" CHAMFER, TYP. AT ALL EDGES #4 AT 12" O.C. EACH WAY FINISHED GRADE (CRUSHED STONE) 6 MIL POLYETHYLENE VAPOR BARRIER co .p 4" SUB—BASE \� r) CONCRETE PAD DETAIL L SCALE: 0. 6" 1' 4' 2/51 3 1/2" SCH. 40 PIPE 3 WAVEGUIDE BRIDGE POST DETAIL SCALE: G' 6" 1' S 5' • -Mobiles 7666 WARREN PKY, STE 100 FRISCO, TX 75034 PRODUCED BY: SPECIALTY TELECOMMUNICATIONS SERVICES, U.C. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SURE 120 OKLAHOMA CRY, OK 73114 (405) 753-7167 BY: BR NCN CCMMUN/CAT/ONS,LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 948-4551 SITE NAME: 'WEST LITTLE ROCK 13TS NUMBER: AR01215A SITE ADDRESS: 2194 S FILLMORE ST ILITTLE ROCK AR 72204 PROJECT NUMBER: AR01215A WIWIA- Sgp,iE OR T� ENGINEER ,�► 1k�kt ,� No. 16564 � f /r _o N R C 896 PE #16564 M 12/31/17 NO DATE DESCRIPTION BY f u l l I NDP I I � � A I #4 AT 12" O.C., EACH WAY 2/S1 3/10/15 PRELIM ISSUE tI I� D 6" CONCRETE SLAB JWM ON GRADE, RE: 2/S1 _ _ ,_TT I PRELIM ISSUE JWM F 14 JI I 12'-0" TYPICAL EQUIPMENT FOUNDATION PLAN — 0 0 3/4" CHAMFER, TYP. AT ALL EDGES #4 AT 12" O.C. EACH WAY FINISHED GRADE (CRUSHED STONE) 6 MIL POLYETHYLENE VAPOR BARRIER co .p 4" SUB—BASE \� r) CONCRETE PAD DETAIL L SCALE: 0. 6" 1' 4' 2/51 3 1/2" SCH. 40 PIPE 3 WAVEGUIDE BRIDGE POST DETAIL SCALE: G' 6" 1' S 5' • -Mobiles 7666 WARREN PKY, STE 100 FRISCO, TX 75034 PRODUCED BY: SPECIALTY TELECOMMUNICATIONS SERVICES, U.C. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SURE 120 OKLAHOMA CRY, OK 73114 (405) 753-7167 BY: BR NCN CCMMUN/CAT/ONS,LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 948-4551 SITE NAME: 'WEST LITTLE ROCK 13TS NUMBER: AR01215A SITE ADDRESS: 2194 S FILLMORE ST ILITTLE ROCK AR 72204 PROJECT NUMBER: AR01215A WIWIA- Sgp,iE OR T� ENGINEER ,�► 1k�kt ,� No. 16564 � f /r _o N R C 896 PE #16564 M 12/31/17 NO DATE DESCRIPTION BY A 10/24/14 PRELIM ISSUE NDP B 3/3/15 PREUM ISSUE JWM C 3/10/15 PRELIM ISSUE JWM D 3/17/15 PRELIM ISSUE JWM E 13/30/15 PRELIM ISSUE JWM F 14 7/15 PRELIM ISSUE JWM 0 4/8/15 CONST ISSUE JWM 1 9 13 15 CONST ISSUE JWM 2 5 18 16 CONST ISSUE JWM SHEET TITLE: CONCRETE PAD DETAILS SHEET: S 1AR0ICKO: PROJECT ^ L B nonY: CKOJWM I EXISTING 8'-0" WOOD FENCE — -� I �r PROPOSED 2" PVC CONDUIT - FOR FIBER/TELCO FROM !' SOURCE TO T -MOBILE UTILITY RACK. VERIFY CONDUIT SIZE WITH TELCO COMPANY. } PROPOSED RAINTIGHT EMT POWER/TELCO CONDUITS ANCHORED TO SIDE OF CONCRETE PAD kI EXISTING 12'-0" WOOD GATEI UNDERGROUND RIGID CONDUIT REQUIRED SPANNING GATE OPENING, TYP. i PROPOSED UTILITY CONDUITS PROPOSED MUST BE A MIN. OF 18" (TYP.) �. METER FROM FENCE LINE, RE: 2/E2 FOR TRENCHING DETAIL L PROPOSED (1) 2" PVC CONDUIT FOR POWER FROM POWER SOURCE TO T -MOBILE 0 A17 N sam EXISTING ICE BRIDGE EXISTING 150' MONOPOLE PROPOSED T -MOBILE 10'-0"x12'-0" CONCRETE EQUIPMENT PAD AND LEASE AREA, RE: 2/El PROPOSED T -MOBILE ICE BRIDGE PROPOSED T -MOBILE SSC CABINET PROPOSED T -MOBILE UTILITY RACK FOR EQUIPMENT, RE: 1/G3 EXISTING H -FRAME EXISTING VERIZON dCRETE PAD EXISTING GENERATOR POWER METER ON UTILITY RACK (IN COMMON TRENCH x -- — - WITH TELCO). VERIFY CONDOR SIZE WITH POWER COMPANY. x x x x 4 UTILITY ROUTING PLAN x x J PROPOSED 2" RAINTIGHT BY CONDUIT WITH PULL STRING NDP FROM PPC CABINET TO SSC CABINET, RE: 4/E2 C 3/10/15 PRELIM ISSUE JWM D 3j1 7 15 PRELIM ISSUE JWM E 3J30,/115 PRELIM 1 ISSUE JWM F 4/7/15 PRELIM ISSUE JWM �, �i _ I � � ', • a• I , JWM ••y I / PROPOSED T -MOBILE y * t L PPC CABINET, RE: E3 13Y: non o PROPOSED SSC CABINET •y .s r, + PROPOSED RAINTIGHT " •', i EMT POWER/TELCO •i . •r s` CONDUITS ANCHORED TO ,' + SIDE OF CONCRETE PAD �'Y Y .x+ e7 ENLARGED UTILITY ROUTING PLAN SCALE: N.T.S. SSC Conduit Layout New NODE B RRLFs Can't Go On The Tower _ Teiw Corxi'u�s — DC Pawef C-0ndull AC Pouter Condlnl PPC suppon cab PROPOSED T -MOBILE UTILITY RACK FOR - EQUIPMENT, RE: 1/G3 PROPOSED H -FRAME, RE: 1/G3 i • -Mobiles 7668 WARREN PKY, STE 100 FRISCO, TX 75034 PRODUCED BY: � 5�5 SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SURE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 F. BR HCH COMMU/V/CAT/ONS, LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (91B) 949-4551 SITE NAME: (WEST LITTLE ROCK 13TS NUMBER: A R01215A :SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 13ROJECT NUMBER: A R01215A S�ATF aR �2. �■ ENGINEER PC No. 16564 � Existing �O.7 �+ !.w# NODE B !yN R. ��g/116 PE #16564 XP 12/31/17 0 TYPICAL SSC CONDUIT LAYOUT %J SCALE: N.T.S. JOI DATE DESCRIPTION BY A)10/24J14 PRELIM ISSUE NDP B J 3/3/15 PRELIM ISSUE JWM C 3/10/15 PRELIM ISSUE JWM D 3j1 7 15 PRELIM ISSUE JWM E 3J30,/115 PRELIM 1 ISSUE JWM F 4/7/15 PRELIM ISSUE JWM 0 4/8/15 CONST )SSUE JWM 1 19/13/15 CONST ISSUE JWM 215/18/16 CONST ISSUE JWM !SHEET TITLE: UTILITY PLAN & CONDUIT LAYOUT DIAGRAM SHEET #: E 1 PROJECT #: AR01215A L 13Y: non CKD: JWM (3) #3/0, (1) #6G, 2" CONDUIT #2 INSULATED COPPER GROUND WIRE 250A GENERATOR RECEPTACLE (FURNISHED WITH PPC) .1 ONE LINE DIAGRAM I SCALE: N.T.S. CONCRETE PAD (SHOWN) OR PLATFORM RIGID STEEL CONDUIT PVC SCHEDULE 40 SIZE AS SHOWN ON LAYOUTS 0 CONDUIT DETAIL v SCALE: N.T.S. FROM POWER SOURCE (120/24OV, 10, 3W). (3) #3/0 2" CONDUIT OR PER LATEST NEC CODE 200A METER TO BE FURNISHED BY UTILITY COMPANY AND INSTALLED BY CONTRACTOR FUSIBLE SAFETY SWITCH 2O0A, 2P, ' S/N �I — J (3) #3/0, (1) #6G, 2" CONDUIT 200A PPC, TO BE FURNISHED BY T–MORALE AND INSTALLED BY CONTRACTOR NOTES: 1. ALL ELECTRICAL WORK SHALL CONFORM TO REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AS A MINIMUM STANDARD. 2. ALL ABOVE GROUND CONDUIT SHALL BE RIGID GALVANIZED STEEL (RGS) UNLESS OTHERWISE INDICTED. t 3. ALL UNDERGROUND CONDUIT SHALL BE SCH. 40 PVC UNLESS OTHERWISE I INDICATED OR AS REQUIRED BE LOCAL — — I UTILITY COMPANY, ALL UNDERGROUND J ELBOWS SHALL BE SWEEPING BENDS. *DETAIL PROVIDED BY OWNER* LIQUID TIGHT FLEXIBLE CONDUIT (IF REQUIRED) CONDUIT BODY R=24" MIN. 2--0- TRENCH FINISHED GRADE UNDISTURBED SOIL -z I COMPACTED BACKFILL PER z I — •'• I EARTHWORK SPECIFICATIONS { Xk 4' I UTILITY WARNING TAPE, 12" MIN. DEPTH I Iq �i I — I Mil 2" PVC ELECTRICAL CONDUIT. T. I !� J COORDINATE SIZE AND 2" PVC TELCO CONDUIT. INSTALLATION WITH POWER COMPANY COORDINATE INSTALLATION V–O" WITH TELEPHONE COMPANY MIN. OR AS REQUIRED BY POWER COMPANY r7 TRENCH DETAIL G SCALE: N.T.S. PROPOSED 2" RAINTIGHT EMT ANCHORED TO SIDE OF CONCRETE PAD WITH A DOUBLE PIPE CLAMP ABOVE GRADE. A CONDUIT ATTACHMENT DETAIL `t SCALE: N.T.S. 7668 WARREN PKY, STE 100 FRISCO, TX 75034 PRODUCED BY: 5�S � SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 BR NCH COMMUNICAT/ONS, LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA. OKLAHOMA 74119 (918) 949-4551 517E NAME - 'WEST LITTLE ROCK BTS NUMBER: A R01215A 3ITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 PROJECT NUMBER: AR01215A 5.1ATE OF r----4 ENGINEER V No. 16564 0 _ s PE #16564 IrXP 12/31/17 IVO DATE DESCRIPTION BY 7-107-24–/14 PRELIM ISSUE NDP B 3 3 15 PRELIM ISSUE JWM C 3/10/1 PRELIM ISSUE JWM D 3/1Z/15 PRELIM ISSUE JWM E 3/30 15 PRELIM ISSUE JWM F 4/7 15 PRELIM ISSUE JWM 01 4/8/15 CONST ISSUE JWM 19/13/15 CONST ISSUE JWM 2 S 18 16 CONST ISSUE JWM SHEET TITLE: ELECTRICAL DETAILS SHEET #: E 2 PROJECT #: �': clsD: non JWM - 2 3" GALVANIZED RIGID PIPE 2" RIGID POWER CONDUIT/PVC — BELOW GRADE TO POWER SOURCE 1" RIGID CONDUIT ABOVE - GRADE/PVC BELOW GRADE FOR (2) #2 THHN GRD LEADS 1-5/8" GALVANIZED UNI -STRUT 2" RIGID CONDUIT/PVC - BELOW GRADE TO POWER SOURCE 6'-0" I PLAN VIEW 6'-0" I PROPOSED GPS ANTENNA, FIELD VERIFY ACTUAL LOCATION WAVEGUIDE COVER NEW T -MOBILE LED FLOOD LIGHT W/ MANUAL TIMER SWITCH INSTALLED 8'-0" ABOVE PAD T -MOBILE SUPPLIED RECEPTACLE 1" RIGID CONDUIT ABOVE GRADE/PVC BELOW GRADE FOR (2) #2 THHN GRD LEADS 1" RIGID CONDUIT ABOVE GRADE/PVC BELOW GRADE FOR (2) #2 THHN GRD LEADS PROPOSED DISCONNECT, FIELD VERIFY ACTUAL LOCATION PROPOSED GPS ANTENNA, FIELD VERIFY ACTUAL LOCATION NEW T -MOBILE LED FLOOD LIGHT WITH MANUAL TIMER SWITCH INSTALLED 8'-0" ABOVE PAD PROPOSED ICE BRIDGE 1" RIGID CONDUIT ABOVE GRADE/PVC BELOW GRADE FOR (2) #2 THHN GRD LEADS 1 f T -MOBILE SUPPLIED RECEPTACLE J 2" RAINTIGHT EMT POWER/TELCO ' CONDUIT ANCHORED TO SIDE OF CONCRETE PAD TO SSC CABINET PROPOSED GPS ANTENNA, FIELD VERIFY ACTUAL LOCATION WAVEGUIDE COVER 1-5/8" GALVANIZED UNI -STRUT NEW T -MOBILE LED FLOOD LIGHT W/ MANUAL TIMER SWITCH PROPOSED DISCONNECT, INSTALLED 8'-0" ABOVE PAD FIELD VERIFY ACTUAL LOCATION PPC CABINET (2) 2" RIGID CONDUIT ABOVE - GRADE/PVC BELOW GRADE FOR PPC TO TELCO/POWER DEMARC 2" RIGID CONDUIT ABOVE CONCRETE PAD GRADE/PVC BELOW GRADE FOR PPC TO TELCO/POWER DEMARC .o • :e T.3'rs:-.>~��T„r.xas.:�,;;, - - :�o:... FINISH x=11 I-11 i ;1! 2" RAINTIGHT EMT TELCO/POWER T I FRONT VIEW CONDUIT ANCHORED TO SIDE OF SIDE VIEW �j PPC H -FRAME DETAILS CONCRETE PAD TO SSC CABINET I SCALE: N.T.S. • Mobile• 7666 WARREN PKY, STE 100 FRISCO, TX 75034 UCED BY: 5�S SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 BY: BR NCH COMMUNICATIONS, LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 949-4551 SITE NAME: WEST LITTLE R�CiC BTS NUMBER: AR01215A !SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 (PROJECT NUMBER: AR01215A Fir',( s AT ;a +�1 ARKANSAS IF F AL No. 16564 L 1 16 PE #16564X ifXP 12 12/31/17 NO DATE DESCRIPTION BY 770/774—L14 PRELIM ISSUE NDP B 3 15 PRELIM ISSUE 3 JWM C 3/10/15 PRELIM ISSUE JWM D 3117 15 PRELIM ISSUE JWM E 3/30/15 PRELIM ISSUE JWM RIGID LB CONDUIT BODY 2" RIGID CONDUIT/PVC BELOW GRADE TO POWER SOURCE o JWM El JWM 1 9/13/15 1 CONSTISSUE JWM 2 s 18 16 CONST ISSUE JWM 0 I N SHEET r: E3 PROJECT- AR01215A 2 BY: CKD: non JWM NEW T -MOBILE LED FLOOD LIGHT W/ MANUAL TIMER SWITCH INSTALLED 8'-0" ABOVE PAD T -MOBILE SUPPLIED RECEPTACLE 1" RIGID CONDUIT ABOVE GRADE/PVC BELOW GRADE FOR (2) #2 THHN GRD LEADS 1" RIGID CONDUIT ABOVE GRADE/PVC BELOW GRADE FOR (2) #2 THHN GRD LEADS PROPOSED DISCONNECT, FIELD VERIFY ACTUAL LOCATION PROPOSED GPS ANTENNA, FIELD VERIFY ACTUAL LOCATION NEW T -MOBILE LED FLOOD LIGHT WITH MANUAL TIMER SWITCH INSTALLED 8'-0" ABOVE PAD PROPOSED ICE BRIDGE 1" RIGID CONDUIT ABOVE GRADE/PVC BELOW GRADE FOR (2) #2 THHN GRD LEADS 1 f T -MOBILE SUPPLIED RECEPTACLE J 2" RAINTIGHT EMT POWER/TELCO ' CONDUIT ANCHORED TO SIDE OF CONCRETE PAD TO SSC CABINET PROPOSED GPS ANTENNA, FIELD VERIFY ACTUAL LOCATION WAVEGUIDE COVER 1-5/8" GALVANIZED UNI -STRUT NEW T -MOBILE LED FLOOD LIGHT W/ MANUAL TIMER SWITCH PROPOSED DISCONNECT, INSTALLED 8'-0" ABOVE PAD FIELD VERIFY ACTUAL LOCATION PPC CABINET (2) 2" RIGID CONDUIT ABOVE - GRADE/PVC BELOW GRADE FOR PPC TO TELCO/POWER DEMARC 2" RIGID CONDUIT ABOVE CONCRETE PAD GRADE/PVC BELOW GRADE FOR PPC TO TELCO/POWER DEMARC .o • :e T.3'rs:-.>~��T„r.xas.:�,;;, - - :�o:... FINISH x=11 I-11 i ;1! 2" RAINTIGHT EMT TELCO/POWER T I FRONT VIEW CONDUIT ANCHORED TO SIDE OF SIDE VIEW �j PPC H -FRAME DETAILS CONCRETE PAD TO SSC CABINET I SCALE: N.T.S. • Mobile• 7666 WARREN PKY, STE 100 FRISCO, TX 75034 UCED BY: 5�S SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 BY: BR NCH COMMUNICATIONS, LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 949-4551 SITE NAME: WEST LITTLE R�CiC BTS NUMBER: AR01215A !SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 (PROJECT NUMBER: AR01215A Fir',( s AT ;a +�1 ARKANSAS IF F AL No. 16564 L 1 16 PE #16564X ifXP 12 12/31/17 NO DATE DESCRIPTION BY 770/774—L14 PRELIM ISSUE NDP B 3 15 PRELIM ISSUE 3 JWM C 3/10/15 PRELIM ISSUE JWM D 3117 15 PRELIM ISSUE JWM E 3/30/15 PRELIM ISSUE JWM F 4/7/15 PRELIM ISSUE JWM 01 4/8/15 1 CONST ISSUE JWM 1 9/13/15 1 CONSTISSUE JWM 2 s 18 16 CONST ISSUE JWM :SHEET TITLE: PPC H -FRAME DETAILS SHEET r: E3 PROJECT- AR01215A 2 BY: CKD: non JWM NSD urban RAS configuration 716R (L21 00/1_1 1900119001700) LTE AWS+PCS+L700+ RAS/FASB U1900 (Alpha) FRIJ AWS ----------------------- G�vvn -------- 6to.r-------hrvni FSMF uwrrs Pr...; ANTENNA ONE -LINE DIAGRAM SCALE: N.T.S. -Mobile. 7668 WARREN PKY, STE 100 FRISCO, TX 75034 PRODUCED BY: SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 8Y: BR NCH COMMON/CAT/ONSLLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 949-4551 'SITE NAME: 'WEST LITTLE ROCK BTS NUMBER: AR01215A ,SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 (PROJECT NUMBER: AR01215A I��rr stA��F ARKANSAS No. 16564 1+ �DyN R �. �'8/16 PE #16564 IR49 32/31/17 VO DATE DESCRIPTION BY A 10/24/141 PRELIM ISSUE NDP B 3/3/15 1 PRELIM ISSUE JWM C 3,/10/15 PRELIM ISSUE JWM D 3J17/15 PRELIM ISSUE JWM E 3/3Q/15. PRELIM ISSUE JWM F 4/7/15 PRELIM ISSUE JWM 0 4/8/15 CONST ISSUE JWM 1 9/13/15 CONST ISSUE JWM 2 5/18/15 CONST ISSUE JWM :SHEET TITLE: ANTENNA ONE -LINE DIAGRAM SHEET : E4 PROJECT #= AR01215A EV: ^ L B,.: non C+(D: JWM 5/8" COPPER CLAD GROUND ROD AT EACH CORNER, RE: 5/G2 PROPOSED CONCRETE PAD GROUND RING, RE: 3/G2 AND 1/G3 PROPOSED T—MOBILE 10'-0"x12'-0" CONCRETE EQUIPMENT PAD AND LEASE AREA — — — — — — — — — -- — — — II� I � I / O , I a I I / I� RE: 1/G2 AND 4/G3 FOR ANTENNA GROUNDING DETAIL — — — — — SYMBOL DESCRIPTION RE: 4/G2 FOR TYPICAL EXOTHERMIC WELD (CADWELD) — — — — — + + * + CADWELD DETAILS MECHANICAL CONNECTION + + + * #2 STRANDED INSULATED PROPOSED GROUND BAR + + ++ * ® FOR PROPOSED EQUIPMENT + + + + CHAIN LINK FENCE 3 30 15 PRELIM ISSUE + F AT 15'-0" MAX. SPACING, PER CM * + ++ * r + (2) #2 SOLID TINNED #2 AWG BARE SOLID 1 COPPER WIRES FOR + + + 2 TINNED COPPER CABLE + + * 'SHEET TITLE: COMPOUND GROUNDING PLAN f + I TO GROUNDING SYSTEM PROPOSED T—MOBILE * + 1 + * + \t r { UTILITY RACK FOR EQUIPMENT, RE: 1/G3 FOR ICE BRIDGE POSTS (TYP.), RE: 2/G2 F• �* PROPOSED T—MOBILE _ * SSC CABINET + ++ * r+ + PROPOSED T—MOBILE + + * + ICE BRIDGE + ++ + +' I (1) #2 SOLID TINNED + + + + + + 1 COPPER PIGTAIL FOR PROPOSED CABINET + * + + SYMBOL DESCRIPTION ■ EXOTHERMIC WELD (CADWELD) — — — — — + + * + ■ MECHANICAL CONNECTION + + + * #2 STRANDED INSULATED PROPOSED GROUND BAR + + ++ * ® FOR PROPOSED EQUIPMENT + + + + CHAIN LINK FENCE 3 30 15 PRELIM ISSUE + F AT 15'-0" MAX. SPACING, PER CM * + ++ * I (2) #2 SOLID TINNED + 4- * 1 COPPER WIRES FOR + + + 2 PROPOSED EQUIPMENT + + * 'SHEET TITLE: COMPOUND GROUNDING PLAN GROUND BAR ++++ I PROPOSED T—MOBILE * + 1 + * + I 1 UTILITY RACK FOR EQUIPMENT, RE: 1/G3 I' x x x x \ x x x x x x __--------- --- x x x x x x \ x x x x x x PROPOSED TOWER x x x x x x PROPOSED GROUND E GROUND BAR, RE: 3/G3 x x x x x x TEST WELL. RE: 6/G2 \ x x x x x x \ x x x x x x / - x x�x x x x x �\x x x x x x ❑ ❑ 0 I / ❑ LI �r ❑ D 3 I I 0 0 I s \ G n � EXISTING TOWER GROUND RING .t T •I• +{ + + + + + + + + + + + + + + GROUNDING LEGEND: SYMBOL DESCRIPTION ■ EXOTHERMIC WELD (CADWELD) — — — — — #2 AWG BCW ■ MECHANICAL CONNECTION —"—" #2 STRANDED INSULATED JWM (FROM EQUIPMENT TO MGB) ® GROUND TEST WELL AT GROUND ROD — — — CHAIN LINK FENCE 3 30 15 PRELIM ISSUE 5/8"xB'-0" COPPER CLAD GROUND ROD F AT 15'-0" MAX. SPACING, PER CM EXISTING 150' MONOPOLE TRUE NORTH (0.61' E) COMPOUND GROUNDING PLAN MAG SCALE: 0' 1' 5' 10' -Mobile, 7668 WARREN PKY, STE 100 FRISCO, TX 75034 PRODUCED BY: 5 S. SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SURE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 BY: BR INCH COMMUN/CAT/ONS, LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 949-4551 'SITE NAME: 'WEST LITTLE ROCK IBTS NUMBER: AR01215A 'SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 PROJECT NUMBER: AR01215A #0,gf - SZ AT E �4p f ARKANSAS *E I ; f P I F E I �. GIN R f N0.16 64 _oyN R . 16 PE PE #16564 J[P 12/31/17 0 DATE DESCRIPTION BY A 10/24/1 PREUM ISSUE NDP B 3./3,/15 PRELIM ISSUE JWM C 3/10/15 PRELIM ISSUE JWM D 3 17 15 PRELIM ISSUE JWM E 3 30 15 PRELIM ISSUE JWM F 4 7 15 PRELIM ISSUE JWM 0 4 8 15 CONST ISSUE JWM 1 9 13 15 CONST ISSUE JWM 2 5 18 16 CONST ISSUE JW 'SHEET TITLE: COMPOUND GROUNDING PLAN SHEET #: PROJECT #: : BY: non CKO:L JWM !f 11 f�i S da' 6" Ed SCALE: 1 _ =8O' �]EiLAa e7- ,�yy¢j SURVEY BY PS(l125 DATED 2/2/06 FOR VERfZON WIRELESS OASIS_OF ELEVATIONS ASSUMED S 6 8.9 W 6.90' N 20'692" E 86.47' 528.4'0" 98.89' 29'EO' 2B 24' 1 1 I 0' INGRESS/EGRESS AND UTILITY EASEMENT S S4 'Or 45' a r 7l.4E' _MYU DRIVEWAY SPNALT DRIVEWAY r - S 89'19'24" W 36.09' -' N sr 11,26' E 31-01' N 67'67'11" E SA 76' ' N 90.58'48" W 48.27' PD11Tr ;., 291-MINC 20' UTILITY EASEMENT69.01.12" E � .56' SITE NAME., LITTLE ROCK AR01215 S. - •(I �SL906" E N 88.07'3 7 ^89 74' 64.48 99.5 '43'31' W }o a / N 8/'21'28" E 42.89' INGRE5S/ECRES5 AND UTILITY JV 4=2 Lm maddd)/ N 51'3B'3E" E 79A2• A pare sl 4,} land fy1n,T in .J . at K of tAr S>vLbwsl r of Section 7, -.d -J. 1 Ng' Rn" 12 Y..; py4ssii CouniY. RrFw.sp brtnp me+• pnrtie�Jorly deacr{6vd at Jelleuvd' ` Cpnmvnnnp e! a f- op.n fop yfyr fauna m Lk. Fut TAg1d-W-Wpy I,- ,t F91m S1m1 91 I'll 6 88'10'49" W Sbuthun.! can..r DJ Let ev, Blnrk S7 eJ CA4ny and C.a AQdtilm W Latta R_k, Arkonwr u e.rdrd sn Pla Book I, P . 86 " OA ctrt a COrM)ty CW kr tlff/ar of add Coanly; enmev run N 92.7/' at.:pF41^ E �* ¢ d1M¢n[r of 1889 J K fe ¢ !' erGnyrd glpr Jvlvd Gt flu NerlhurH! camrr cf w tel 10. fhrn[t S S9'4T10' r fe. a dW¢ricr o/ 683. S1f f f to ¢ $/fi tvp.d _bar u! N 87'04'58" W 9 89.69'49• W (SCOW) end Me Adnf of Eepim.ingP.- S OS IST;Y6" F f 1,1'U170 69.00 JNI t. 7870' N 84.08'17• W 84-86' mopped *alar.11 (5MWr $Arrur $ 67AWSW W f- ¢ disl¢nn E0 !4 ¢ 5/R' -mm. ES 64' roar al (SMW); Ll-- N DYbtRS W fil a dflfa..Ce .f 60-00 ft.1 fe ¢ 3/F' -pp-4 -b- dr! (SYWI.• thrnN N 77_Gi3a• F 1x a dug- q 50.00 f f N W Pow N 6.a6wrinr. sold vevw drsrrU1 paae.l emtntnr 0. pen; mer+ a teas b7- ddid) An r¢rrmrnl 1yln� 1n the rest K of rhe Swthmrat % $ Sr.tWT n 7. .muhtp 9 Nor N, R.-ge t2 rqt. PM:Wki t�evnty. Arkomsw being mon pmt(eutvHV 67- 0Hb.d vs JbUo s' Cnlwnrnebaa ve ¢ 1• •9m n rtbf faand en ehr Celt rSpM-Wx., Nn. of Ptr=* S-' e! h, S .-drdt+n PLIC Bank tjkye 88 in Lhr Clj-d y urn AddlMars i4 awtd G�w1.<1F- [Amer run N of atdg B fir a dtafmwr v/ 11091-1 !r a !' t*ltape4 pipr et 7-h. NrarArtt+t colas of nid tot 7-0: fhrnt4 S aD_.A. " W / r . diner.. of 579,55 fltrl eo ¢ d/iS' ee. prd llbo7- +7-r (srr). mmc. $ 02Sr17•E f ¢ dtrsmre. of 5000 J-9 t. r 5/A- r¢ppvd -6m -9 (SMW): d-%. S 971NH'JS W f- o dtstofst•r of 50.00 furl to a S//0- -ad eel- -1 (SWIL m.nr• N 02:iif•2s r Jar ¢ dflt of 15.00 f..t 7-o w P.[n[ j BepW.tnp vS an rngnra/rgnn m.d vnl[y Eearmr4l Ml..q ZO fm to " Uh end 444 fo h I .oeA ddr of OM lWro�tnV d.N.•+lbrd dr.rtn.: fnenrr 3 A7 A7£7 r J4r . dlalonce y {d 34 Je7-f e. ¢ pe1nL lh,-. N 50 •SS4B' f fa• a atnanr4 eJ Ifd P! J e! !. a p.av rhrner ?f SJ'WY45' r far v d4 rarer s1 1118.46 flrf to o p.inC Ih.nrr N PS=$PfT' r for a di -1 x1261"2,4171 t. ¢ W.Int IA.fw Jf u:ans r f ¢ d4fnwr of 37 R7- frrl fv .pylar: fh...ne N ?❑ t. F fe* . dt.tan. . 55.4+ 571 f. f pNnL lNner N B7^+SS!' W M e d4frn.r of 6T•801tH fo a pain! !Amer N 6T"678 f'R � a dIH¢A4t of 64.76 feel fe a pain! fMnn M d2_I1 FC i far o O(rfVKH ¢ 37-.0! fief f. ¢ po4.t lkmee N 9S 89.14• £ f.. n du!¢nrt of S 5 pat r a p.rnl: !Hoer S Ot•6tr E fe'' a d@reaer 4f 78 7D f 7-1 7-u n ��..Wfy rhfw. S 1j"t f. C for ¢ dL1e w of Ss.64 h.7- le ¢ pa4eA 1hNicW N 89-dS'J 9' E f- dlrfanw .f 04.88 JJ f re a M..nca N 08.1 o4S a JAm a dfrtawrr of 317-$8 fa4! m ¢ p4tnA- lhtr.ea H d1 9837' t[ f.7- a dfatmr. of 734@ JrH fs o p.4.f. tAnree N a3f1-x129• E for .• iwora vl 4x8! Nu m n petal.• en.rer x n 4905 £ !- ¢ rA�„�: s 36er5iiar s[fr�r ¢ eue�c. } ai��:ri�..w.E fear i ,� �.64.*l�tnr� f %, SArerl end D.r Patnf .J rndi»p 8051 4bnv dnsretrd .o+msrwr ermtaiaT 0->u rH+.3 "w7-+ e7- IJa: SEE DETAIL Zn trrflsr., lrumvne x' fu fgu¢d.d1 An eurWornt lVing in the rrsl AV Dir SoWowtrf N 1 SwmH 7 Tnwnrhq. I Norah Rangy 12 Yeo. PWmki County. Arkansas W r man porKi A rgr dtfrrl6.d as fel/aur!: TjOy)lq 5/8' REt AR N Comm iW nl a r vp- top pi- found an the East ri9td-q-,w7- of idu ;W- Stnet a.1 U- / N 87'0795" E 50.00' Soulhw.al earner of Lot 10, Block 37 of Cherry land Com Adavirl 1. Littlr Rock. Arkansoa u ere "d 44 7-7-07- Er.lh t. Fhg. d3 in IAr Clrcvl! Cmmtyefckw, Dfrws of add c-tv fh.nn 7-.n s joj�JSJr7 r fw vAdtA and rylrp f0 ofrt 1 aH�wehtsLIt of ow fPtt-4 �dn�ertWd a UinHrt�'rN-• Ihme. N '� 20 e' rOOD FENCE �x� i6�J71 l8' ■ ¢ ¢nrH of 167.77 firr 1. print- 1hmrT .1112 1WtT W . du[onnr of 90. 67 fat x�x��1e~x to lh. P.Od of Ending Said abw4 dastr{b;d .--t -ti- 0.09 ac7aa, more or less. CRA VEL X CTNTHB lit U uACFMrRT •D [ . Al lyinIn b �Aatrc Tomhip 7 No1ARmge yr _ o -,. LVE 12 reePc-k{ Cu[y,Ask- prt.W*tVdm1d os flows: 2S LO:W 1 CAIN �T . o . l evmaKncnl7 nt n I' �m !ap prpt feund�mmt rMmFid�Cez�atddffta~o.f to Lllfte R.7-; �rRenr�a a1' SOUTH II sellrh,arrt eerl..r 0J tri IA B 57 1 u' tsar •'4• • Teterdtd in Ptef Ee.k J. Pyr S6 !r !Ae LSrta.iA {'uad)r CirrYr aJ/kr ke .etd warty. throe. ton N w�Q�9R1AW {AWa�1GEl rlrcb y O1np,-4Y• E fo+• a durlanar v 48.87 J. t.. !' pipr feared n7- eh. 7-r rh..,i eomnr eJ Let to. 1rirM1tt 5 63 S7'R0' W je n dim- .f 69136 frrf t. a 5f8 vapprd alar att 9aN^arW n a .-•q..'. (SMS'): ehena+ s OZ-WJ'X5" E � e dWJ w of 56.00 fret !. ¢ a/It mppvd rrtpr set Owl. 87' T3S Y fx a dtsfa x7- .T 50.00 J.er to 5%3' 674 r.t4. fAM1N N 'a• iii D1rr6TP6" W /oT a Ofrf>rArr of 55.00 rr rt fD . paltl! woe. s ✓.TYO' W int+ w > 29,74 frrl 1. a pmnr: thorn N SO -$1'48 rJ1n• 4 dlat-iv. y i7. is J.al fo PM Ana+! ppJJ 7-a 'r- 9agly. .f an MlDvy iaamuty Mayr x0 l••7- in nfdN w.d lyby f0 /.e! m 7-.M a[d+ of 1We w X I C�.� Iblt.0 dArtv{lsd e.ntrTlLly: tA.r.xe N 69 orrr i' a dlrlonct p/ 9..7.55 fres le M. Petit of } a {fldt4p. sa[d abe.. d4at nttd td[rrMdt emwm 00t ern; marc e7- lraa x Ffnee Asrormatr.n !hv pr.p.rty rel xAMtn tAr leo ri95 Ft..d 4d J aY 6, Z 9 7-r eA.r feed )nauwAer Rdr N F�yE Y.p Canmvut[yl !Mu[ Atinntrr O5flKORS'vC deed .KILT 6, xarS 1 ' UTILITY EASEMENT •B" L N 30.68'4B" W 67.14' 1 N 87'57'20' a OF BEGINNING VERIZON LEASE PARCEL { 1 ' 5er azyAr1 , ! t �, -E UTIL717 BASEMENT 'A' POIN7 OF BeCINNING INGRESS/EGRES$ AND VTILITY CASEY£ 4y S 62'b9'43" W 94 37• µT._'. yn#: Vj.f9tti Wfl': .i :'�:? r. ._ :. ..•. - y, i7 . •. ry •;i41� fv^�'il', � fillly � i I�i11' ". T.' 3}.1I. 'S' _ i ., 1'. :.� a �Y t:.• �'f' � LOCA TION LEGEND SET 1/2" REBAR 0 POUND AS NOTED COMPUTED CORNER -0 LEASE LINE TIE LINE - - CENTERLINE EASEMENT EDGE OF OF EASEMENT - - FENCE LINE-xx- POWER POLE 0 TELEPHONE PEDESTAL m CTW -AROUND TEXT WELL a°44'lT4reu� OF AU1 KEEN JF �SURVEYIN��' a� LCV � U gRKA NS� ' "" r rHrMPEPrPr J' NW CgpL1pN LO7 rao DL OCC S7 S 89'97'20" W 519.65' / CHERRY AND COY AOOMON TO THE CITY OF LITTLE ROCK I. ty V n R i pOUNO f' P!P$ i ` r gm CORKOR L07 to BLOCS 37 OF BEGINNING 20' UTILITY EA0EMENT "A•SB7^fiB`OB"W�9B 96 L f CNZMr AND COX AMMY 1b THE CITY OF LITTLE ROCK ^- �-- -f_ � __ 1 5/8" GALVANIZED UNI -STRUT 3" GALVANIZED PIPE FURNISH AND INSTALL #2 - THHN CU GROUND WIRE FROM GROUND LOOP TO TELCO GROUND BAR IN PPC FURNISH AND INSTALL #2 THHN CU - GROUND WIRE WEATHER SEALED IN RIGID CONDUIT FROM PPC GROUNDING ELECTRODE CONDUCTOR TERMINAL TO GROUND LOOP #2 BARE SOLID TINNED DATE DESCRIPTION CU GROUND WIRE A 10/24/141 PRElJM ISSUE FURNISH AND INSTALL B #2 BARE SOLID TINNED ISSUE CU GROUND WIRE C PROPOSED - SSC CABINET I�#2 BARE SOLID TINNED CU V GROUND WIRE FURNISH AND INSTALL - 2/0 INSULATED PIGTAIL (1) PER CABINET TYPICAL EQUIPMENT GROUNDING RISER DIAGRAM SCALE: N.T.S. TO ANTENNA CONNECTOR TO JUMPER OR ANTENNA 1C � COAX CABLE O COAX CABLE '0 GROUNDING CLAMP KIT INSTALLATION OF BUTYL & TAPE PER MANUF. SPEC'S PROVIDED IN GROUND KITS #6 AWG GROUNDING CONDUCTOR TO GROUND BUS BAR TO CABINET CONNECTION OF CABLE GROUND KIT TO ANTENNA CABLE L SCALE: N.T.S. PROPOSED UNITSTRUT, AS REQUIRED FOR PROPOSED EQUIPMENT .177 I BOND TO EXISTING CONDUCTOR WITH #2 BARE SOLD TINNED CU GROUND WIRE -A---- --- -- -1--- -� BOND WAVEGUIDE BRIDGE SUPPORT POSTS TO GROUND LOOP WITH #2 BARE SOLID TINNED CU GROUND WIRE CADWELD CONNECTION #6 AWG FROM ANTENNA MOUNTS AND EQUIPMENT GROUNDING (RE: 1/132 FOR QTY) ,,. "^' � LUG, CONTRACTOR TO SPRAY GROUND BAR WITH COLD GALVANIZE ONCE ALL CONNECTIONS ARE COMPLETED 0 GROUND BAR DETAIL A-) SCALE: N.T.S. PROPOSED GROUND GROUNDED TO TOWE #6 AWG INSULATED STRANDED COPPER FOR EQUIPMENT GROUNDING, TYP. TRUE NORTH (O.6M1AG E) A ANTENNA GROUNDING PLAN SCALE: N.T.S. VENDOR: T • -Mobile 7668 WARREN PKY, STE 100 FRISCO, TX 75034 UCED BY: a SPECIALTY TELECOMMUNICATIONS SERVICES. LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY. SUITE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 BY: BR NCH COMMU/V/CAT/ONS,LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA, OKLAHOMA 74119 (918) 949-4551 :SITE NAME: 'WEST LITTLE ROCK IBTS NUMBER: AR01215A SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 PROJECT NUMBER: AR01215A IVO DATE DESCRIPTION BY A 10/24/141 PRElJM ISSUE NDP B 3/3/15 PRELIM ISSUE JWM C 3/10/15 PRELIM ISSUE JWM D 3/17,/15 PRELIM ISSUE JWM E 3/30/15 PRELIM ISSUE JWM F 4/7 15 PRELIM ISSUE JWM 0 j 4/8/15 CONST ISSUE JWM 119/13/15 CONST ISSUE JWM .215/18416 CONST ISSUE JWM !SHEET TITLE: GROUNDING DETAILS SHEET #: G3BY: PROJECTd Y: IC cKDnon ANTENNA MOUNT ANTENNA 1 (TYP.) ANTENNA (TYP.) ANTENNA 2 ANTENNA 3 TMA CABLE GROUNDING I I I I I COLLECTOR BUS BAR KIT, RE: 2/G3 (TYP.) I I I I I I (GROUNDED TO TOP OF TOWER). HYBRID CABLE (TYP.) — — L_�� — - J J SR (GROUNDED TO MID #2 AWG TSBC GROUND WIRE POINT OF TOWER FOR TOWERS OVER 200'). METAL CABINETS SUCH 3/4" FLEX CONDUIT AS POWER, TELCO, SLEEVE — ---- — — -- DISTRIBUTION PANEL, BUSS BAR MOUNTED r — — — — — — — — — I WAVEGUIDE BRIDGE WITH INSULATORS AT I r J SUPPORTS, EQUIPMENT FINISHED GRADE BASE OF TOWER I II i — — — — — "-` '-- — — �CPPORT, PLATFORM, I I MODULAR z: CELL INTERNAL EQUIPMENT g L✓' L j {�I CABINET GROUND BUS BAR WAVEGUIDE BRIDGE I """ 1 SUPPLEMENTARY GROUND BUS BAR I I I ,ABINET FRAME I GROUND WIRE MOUNTED AT I I I I 1 WAVEGUIDE BRIDGE I I I I--- �--- MAIN GROUND RING IF r CADWELD (TYP.) -A --------- 4-L--------- 4 TOWER GROUNDING RISER DETAIL SCALE: N.T.S. TYPE GT TYPE VS TYPE 2–YA-2 TYPE SS TYPE VBC TYPE YGHC 4 TYPICAL CADWELD DETAILS SCALE: N.T.S. TO MAIN GROUND RING ,r7 STUB UP DETAIL L SCALE: N.T.S. COPPER GROUND ROD (5/8'x8'-0" LONG) 5 COPPER -CLAD STEEL GROUNDING ROD SCALE: N.T.S. z 0 iv 0 I N 7 GROUND RING DETAIL 0 SCALE: N.T.S. x af' GROUND TEST WELL DETAIL SCALE: N.T.S. FINISHED GRADE AGGREGATE SURFACE #2 AWG SOLID BARE TINNED COPPER EXTERIOR GROUND RING EXOTHERMIC WELD TO GROUND ROD GROUND ROD (TYP.), RE: 5/G2 6"x24" DEEP INSPECTION SLEEVE, PVC OR SOIL PIPE WITH CAP OR EQUIVALENT. CADWELD CONNECTION (TYPE–GT) 1" WIDE SLOT FOR GROUND WIRE EXTEND 2" ABOVE GROUND WIRE #2 AWG SOLID TINNED COPPER WIRE (EXTERIOR GROUND RING) 3/4" CRUSHED STONE OR EQUAL FILL TEST WELL TO WITHIN 2" OF TOP OF GROUND LOOP WIRE 5/8"0x8' LONG COPPER CLAD GROUND ROD •Mebile- 7668 WARREN PKY, STE 100 FRISCO, TX 75034 PRODUCED BY: a SPECIALTY TELECOMMUNICATIONS SERVICES, LLC. PROFESSIONAL ENGINEERS AND CONSULTANTS 13431 N. BROADWAY, SUITE 120 OKLAHOMA CITY, OK 73114 (405) 753-7167 BY: BR NCH COMMUN/CAT/ONS,LLC BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 TULSA. OKLAHOMA 74119 (918) 949-4551 :SITE NAME: WEST LITTLE ROCK I3TS NUMBER: AR01215A :SITE ADDRESS: 2194 S FILLMORE ST LITTLE ROCK AR 72204 PROJECT NUMBER: AR01215A ATE OF - f'4 ARKANSAS 'L_J WIA No. 16564 p�N R. C d�7G PE #16564 EXP 12/31/17 NO DATE DESCRIPTION BY A 10/24/14[ PRELIM ISSUE NDP B 3,/3/15 PRELIM ISSUE JWM C 3 10 15 PRELIM ISSUE JWM D 3/17/15 PRELIM ISSUE JWM E 3/30/15 PRELIM ISSUE JWM F 1 4 7/15 PRELIM ISSUE JWM 0 4/8/15 CONST ISSUE JWM 1 9113 15 CONST ISSUE JWM 2 15J18/16 CONST ISSUE JWM 'SHEET TITLE: GROUNDING DETAILS SHEET LJ PROJECT !j:REV: BY: CKD: non JWM L