HomeMy WebLinkAboutZ-5321 Staff AnalysisMay 8, 1990
ITEM NO. 7 - Z-5321
Owner:
Applicant:
Location:
Request:
Purpose:
Size:
Existing Use:
Savers Incorporated/RTC
J. E. Hathaway, Jr.
Shackleford Road
Rezone from 11R-2" to 11I-2"
Wholesale warehouse
18.0 acres
Vacant
SURROUNDING LAND USE AND ZONING:
North - Vacant and mobile home park, zoned 11R-2"
South - Single family and industrial, zoned 11R-2" and
nI-2"
East - Vacant, zoned "R-2"
West - Vacant, zoned 11R-2" and "I-1"
STAFF ANALYSIS•
The request before the commission is to rezone 18 acres on
Shackleford Road from 11R-2" to 11I-211. The property is
situated about 600 feet north of Colonel Glenn Road and the
site is vacant at this time. The land has a depth of 1,547
feet with the rear portion of it in the floodway and
floodplain. Based on information provided by the City's
Engineering staff, it appears that the floodway involves the
east 420 feet of the site and the 100 year floodplain is the
next 260 feet. (The floodway and the floodplain areas are
identified on the accompanying sketch.) Should the parcel
be rezoned to the industrial classification, the proposal is
to develop it for a wholesale warehouse.
The existing land use includes single family, a large mobile
home park and industrial. The industrial uses range from
manufacturing and warehousing to a salvage yard. In
addition to the developed tracts, a percentage of the
acreage is still vacant. There are also a number of
nonconforming uses in the area. Zoning is similar to the
land use pattern with "R-2" and 11I-211. The property in
1
r
May 8, 1990
ITEM NO.: 7 - Z-5321 (Continued
question abuts 11R-2" and 11I-2" zoning. Across Shackleford
Road, the zoning is 11R-2" and 11I-1. The site under
consideration is part of the I-430 Plan area and the adopted
land use plan recommends the property for multifamily use;
the floodway land is shown as open space. The southern
property line of this parcel is the land use boundary
between the multifamily area and industrial to the south.
The plan shows a large industrial area extending south along
Shackleford Road for approximately one mile. This sizeable
industrial area is the result of several rezoning actions to
"I-1" on Shackleford Road south of Colonel Glenn.
After carefully reviewing the request, staff is of the
opinion that an industrial reclassification is a reasonable
option for some of the property. Because a high percentage
of the plan's recommended industrialarea is zoned "I-111, and
with an "I-1" tract directly across Shackleford, staff
suggests that an "I-1" reclassification is the appropriate
industrial district for the property. "I-1" is a site
review plan district which requires Planning Commission
approval of any development plan prior to the building
permit being issued. The recommended "I-1" is only for land
area outside the floodway. City policy requires the
designated floodway to be zoned "O -S" and dedicated to the
City. (Brodie Creek is identified as "Priority 1 Open
Space" on the -Master Parks Plan.)
In addition to the "O -S" for the floodway, staff is also
recommending that a 75 foot buffer strip be created along
the north property line and zoned "O -S". This is to protect
the multifamily area shown on the plan and to provide some
kind of transition from the industrial zoning to the
residential area. To insure that the buffer strip is
properly maintained, a fence needs to be constructed along
the zoning line between the "O -S" and "I-1" before any
clearing or site work occurs.
Should the industrial reclassification be recommended by the
Planning Commission, a plan amendment will be forwarded to
the Board of Directors along with the rezoning issue. The
plan amendment will shift the industrial area to the north
to conform to the rezoning action.
ENGINEERING COMMENTS:
Shackleford Road is classified as a minor arterial which
requires a right-of-way of 90 feet or 45 feet from the
center line. The existing right-of-way is deficient and
dedication of additional right-of-way will be needed.
K
May 8, 1990
ITEM NO.: 7 - Z-5321 (Continued)
STAFF RECOMMENDATION:
Staff recommends approval of "I-1" and not 11I-2" as
requested for the land outside the floodway, except for a 75
foot area adjacent to the north property line. Both the
floodway and the 75 foot strip should be rezoned to "O -S"
with the floodway dedicated to the City and the 75 foot
buffer fenced off prior to any clearing or site work taking
place.
PLANNING COMMISSION ACTION: (May 8, 1990)
The applicant, Jim Hathaway, was present. There were no
objectors. Jim Lawson, Planning Director, spoke first and
indicated that 75 feet of buffer was excessive and suggested
40 feet as being more reasonable. Mr. -Lawson went on to
discuss the area and the existing land use. He also
suggested that the buffer strip needed to be fenced.
Jim Hathaway addressed the Commission and said there was a
conditional contract to purchase the property for an office
warehouse/showroom. Mr. Hathaway then proceeded to discuss
the site and said 5.7 acres were in -the floodway and he
agreed with the dedication requirement. He also said 3.7
acres were in the floodplain which could be used for some
development. Mr. Hathaway said a 75 foot buffer was a heavy
requirement because there was mature vegetation on the site.
He then offered a compromise of a 25 foot strip with a 6
foot opaque fence on the south side of the open space area.
He also agreed to "I-1" and amended the request.
A motion was made to accept the 25 foot buffer strip as
suggested by Mr. Hathaway. The motion failed to receive a
second.
Jim Lawson said 40 feet for a buffer was more desirable and
he was uncomfortable with the 25 feet'.
Jerry Gardner, City Engineering, discussed the problems with
buffers being cleared and requested that a fence be required
to be installed at the time of the rezoning. Mr. Hathaway
questioned the fence requirement and said he was willing to
do anything reasonable. Mr. Lawson said a temporary fence
was a legitimate public concern and making the fence a
condition of the rezoning was appropriate.
3
May 8, 1990
SUBDIVISION
ITEM NO.: 7 - Z--5321 Continued
Bob Brown of the Environmental Codes Staff made some
comments about the buffer ordinance and said the new code
will require 26 feet of buffering.
A motion was made to recommend approval of "I-1" as amended,
except for the floodway which is to be zoned "O -S" and
dedicated to the City; a 26 foot strip along the northern
property line from the northwest corner to the floodway
which is to remain as an undisturbed "R-2" buffer; and a 6
foot opaque fence is to be constructed on the interior of
the 26 foot buffer at the time of the building permit.
Several comments were made before the vote was taken. The
vote was 8 ayes, 2 nays, 0 absent and 1 abstention (Jerilyn
Nicholson).
A second motion was made to recommend a plan amendment for
the property from multifamily to industrial. The motion was
approved by a vote of 11 ayes, 0 nays, 0 absent.
4