Loading...
HomeMy WebLinkAboutZ-5228-D Map 1,S �, SL EXISTING - GO-CART TRACK TO REMAIN FENCE AND GATE MATCH EXISTING — SIDEWALK [STING SIGN BE FURBISHED LINK CONNECT TO EXJSTING -- `CHAIN LINK FEN�E - - I ¢ � BATTING CAGES # \ /–TO REMAIN Q 3� I ( i ( I Ill EXISTING SIDEWALK ( J 2-7 PROPOSED j CONIC. SIDEWALK MATCH EXISTING SIDEWALK PROPOSED CHAIN LINK FENCE r , / i 1 /// i^ , • DEVE'•�OPER• NAT ONAL PROPERTIES HOLDBtiGS, LLC. MHH PROPERTIES, LLC. j�TA� A' TVI�_'s.,,�CtINEER` 7.07 ACRES CRAF ION, TULL & ASSOCIATES, INC. 0 307369 �F 10825 FINANCIAL CENTER PARKWAY, SUITE 300 LITTLE ROCK, AR 72211 501.6154-245 FAX: 501.664.6704 �.-;iNGi �sFcn� NOTE., THE AREA OF TdIS PROPOSED ADDITION IS NOT LOCATED ON OR NEAR ANY KNOWN DESIGNATED WETLANDS. EMD STS 72 SPACES EXISTING THERE ARE NO PORTIONS OF THE PROPERTY SHOWN HEREON LYING WITHIN A SPECIAL FLOOD HAZARD AREA, AS SHOWN ON FLOOD INSURANCE RATE MAP PANEL NO. 050181 0042 F, DATED U i ((.E ROCK OCTOBER 19, 2001. T 11ar,IVG �i1(t1 ION FIRE FLOW NOTE: MINUTE ';ATPD PER CENTRAL ARKANSAS WATER, STATIC PRESSURE INTENDED TIE LINE IS 107 P.S.I., EY: RESIDUAL PRESSURE IS 102 P.S.I. AT TA FIRE FLOW VOLUME OF 1500 G.P.M. DATE: K* GRAPHIC SCALE IN FEET 30' 0 30' PROPOSED AREA LIGHTING Y Know what's below. Gall before you dig. ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. SAFETY NOTICE TO CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINES, TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. OWNERSHIP OF DOCUMENTS THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON. TULL & ASSOCIATES, INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH OUT THE WRITTEN AUTHORIZATION OF GRAFTON, TULL & ASSOCIATES, INC. NOTIFICATION OF LIMITED SERVICES CRAFTON, TULL & ASSOCIATES, INC., (CTA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A PORTION OF THE WORK INDICATED ON THESE DRAWINGS. THEREFORE. THE CTA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT THE CTA ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION AND ADMINISTRATION 0 THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THEII EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL RELATED TRADES OR CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC— IFICALLY REQUIRED IN THE CTA's SERVICES AGREEMENT WITH THE OWNER. t�GENERAI NOTES PROPOSED MINIATURE GOLF COURSE PROPOSED AREA LIGHTING HIGHWAY BUFFER 1. ENGINEER'S NOTICE TO CONTRACTOR: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE OONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. 2. SAFETY NOTICE TO CONTRACTOR: IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. 3. OWNERSHIP OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERbICES, IS THE PROPERTY OF CRAFTON TULL INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CRAFTON TULL INC. 4. CONTRACTOR SHALL NOT CAUSE ANY INCONVENIENCE TO THE PUBLIC, ADJACENT PROPERTY OWNERS, PEDESTRIANS, ETC. DURING THE CONSTRUCTION OF THIS PROJECT. THE CONTRACTOR SHALL NOT DISRUPT ACCESS TO ADJACENT PROPERTIES AT ANY TIME DURING CONSTRUCTION. 5. THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY IS IDENTIFIED ON THE PLANS AND/OR SPECIFICATIONS. 6. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA, FEDERAL, STATE AND LOCAL REGULATIONS. 7. CRAFTON TULL INC. (CTA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A PORTION OF THE WORK INDICATED ON THESE DRAWINGS. THEREFORE, CTA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT CTA ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION AND ADMINISTRATION OF THESE DOCUMENTS AND/OR DEVIATIONS THEREFORE AND THE EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL RELATED TRADES OR CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPECIFICALLY REQUIRED IN THE CTSAS SERVICE AGREEMENT WITH THE OWNER. `ii® LEGEND (PROPOSED) • LEGEND (EXISTING) LINEWORK -------------------------- EASEMENT LIGHT POLE o SYMBOLS FOUND IRON PIN LINEWORK ----------- EASEMENT 3 E LIGHT POLE ■ TELEPHONE PEDESTAL 'GL POWER POLE CURB m TELEPHONE PEDESTAL 1205 INTERMEDIATE CONTOUR ISI TV PEDESTAL 0 O MANHOLE _ INDEXCONTOUR o SANITARY SEWER CLEANOUT—� ►i A GAS METER SANITARY SEWER LINE >4 GAS VALVE GAS LINE -� STORM SEWER PIPE C DOWN GUY WATER LINE (SPECIFY SIZE ,k TYPE) >4 WATER VALVE --- ---- AIR RELEASE VALVE - - UNDERGROUND TELEPHONE FIRE DEPARTMENT CONNECTION FIRE HYDRANT ASSEMBLY L8� AIR RELEASE VALVE E - ~�T UNDERGROUND ELECTRIC Al FIRE DEPARTMENT CONNECTION ® REDUCER FIBER OPTIC -� O WATER METER OVERHEAD ELECTRIC ® SPRINKLER HEAD - - - --�^ OR JUNCTION BOX (SPECIFY UNDERGROUND TELEVISION ELECTRIC PEDESTAL ON PLAN SHEET) OVERHEAD TELEVISION OVERHEAD TELEVISION GRATED INLET ry ........__ __ DROP INLET CHAIN LINK FENCE WOOD FENCE BARBED WIRE FENCE TREE —•- FIBER OPTIC RIGHT OF WAY TREE TO BE REMOVED ROAD CENTERLINE `ii® LEGEND (PROPOSED) • SYMBOLS SET IRON PIN LINEWORK -------------------------- EASEMENT LIGHT POLE Nk POWER POLE CURB ■ TELEPHONE PEDESTAL 1208 0 TV PEDESTAL INTERMEDIATE CONTOUR 1205 Q MANHOLE INDEX CONTOUR 0 SANITARY SEWER CLEANOUT --_ GAS METER SANITARY SEWER LINE ►i GAS VALVE ® STORM SEWER PIPE GAS LINE STRUCTURE NUMBER WATER LINE WATER VALVE SN�� -fes FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE No AIR RELEASE VALVE - - .,ir FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC WATER METER OVERHEAD ELECTRIC to B BACK FLOW PREVENTER ® REDUCER FIBER OPTIC ® PLUG VALVE DROP INLET, GRATED INLET UNDERGROUND TELEVISION OR JUNCTION BOX (SPECIFY - ON PLAN SHEET) OVERHEAD TELEVISION CHAIN LINK FENCE WOOD FENCE BUILDING SET BACK RIGHT OF WAY PROPERTY LINE ROAD CENTERLINE -"COTES 1. THE DESIGN, INSPECTION, AND CERTIFICATION OF ANY RETAINING WALL SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT LIMITED TO, SEGMENTAL RETAINING WALLS, MASS GRAVITY WALLS, GABION WALLS, ETC., GREATER THAN FORTY-EIGHT INCHES IN HEIGHT, SHALL BE BY OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN SHALL BE FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS ONLY. 2. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA STANDARDS. 3. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. 4. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 5. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 6. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE. 7. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. 8, CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. 9. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM THE SITE. 10825 Financial Center Parkway, Suite 300 Little Rock, Arkansas 72211 pGrafton Tull engineering I surveying 501.664.3245 t 501.664.6704 f www.craftontull.com CRAFTON TULL CELEBRATING 50 YEARS BIG ROCK MINIATURE GOLF LITTLE ROCK, ARKANSAS Key Plan Nn. Description Date This document, and the ideas and designs incorporated herein, as an Instrument of professional service, is the property of Crafton, Tull & Associates, Inc., and Is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. �-IµUCTION PROTECT NO: 13804000 AGO RFLP ISSUEDATE: 08/26/13 Q° THIS F� CONTACT: &PETERSON a. DOCUMENT IS CHECKED BY: 2 PRELIMINARYIN "- NATURE AND IS NOT PRELIMINARY AFINAL,SIGNED PLANS �, AND SEALED DOCUMENT C 2013 Crafton, Tull & Associates, Inc. -1 DOCUMENT VA°0 NOLLDna is SITE PLAN C-101