HomeMy WebLinkAboutStaff Report for Z-8284-ADecember 8, 2022
ITEM NO.: 5 FILE NO.: Z-8284-A
NAME: R & D Holdings Office / Warehouse – Conditional Use Permit
LOCATION: 8707 Mabelvale Pike
DEVELOPER:
R & D Holding
Partnership P O Box
642
Mabelvale, AR 72103
OWNER/AUTHORIZED AGENT:
R& D Holding (Owner)
Jonathan Hope (Agent)
Hope Engineers
147 South Market St.
Benton, AR 72015
SURVEYOR/ENGINEER:
Hope Engineers
147 South Market St.
Benton, AR 72015
AREA: 2.76 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 7 PLANNING DISTRICT: 15 CENSUS TRACT: 41.03
CURRENT ZONING: C-3
VARIANCE/WAIVERS: No variances requested.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is requesting a Conditional Use Permit to allow the use of an existing
C-3 zoned property at 8707 Mabelvale Pike for a new one (1) story 12,500 square
foot Office / Warehouse Facility.
December 8, 2022
ITEM NO.: 5 (Cont.) FILE NO.: Z-8284-A
2
B. EXISTING CONDITIONS:
The site is currently undeveloped with the remains of an existing paved drive at the
central north perimeter connecting to Mabelvale Pike. The site is partially tree
covered and slopes slightly from north to south.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property within 200 feet of the site and all neighborhood associations
registered with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS:
1. A grading permit is required prior to initiation of work. Grading permits are
issued by the Planning and Development Dept. at 723 West Markham Street
after approval of sediment and erosion control plans, grading and drainage
plans, land survey, drainage study, and soil loss calculations per City’s
stormwater management and drainage manual. Contact Planning and
Development Dept., Civil Engineering Private Development at
501-371-4817 or at 501-918-5348 or Permits@littlerock.gov to schedule an
appointment for issuance or to answer any questions. Permit cost is based on
total project area at $100.00 for the less than ½ acre, $200.00 for ½ to
1 acre, and $200.00 for the first acre and $100.00 for each additional acre for
project greater than 1 acre.
2. Any work involving one (1) or more acres of disturbed area requires a State of
Arkansas NPDES permit. Contact the Arkansas Department of
Environmental Quality, NPDES branch at 501-682-0744 for applications and
information about General Stormwater Discharge Construction Permit
#ARR150000.
3. Per City Rev. Code 29-99, stormwater detention for developments is required.
Provide stormwater detention infrastructure to satisfy this requirement.
4. A drainage study showing all hydrologic and hydraulic calculations for the
proposed storm sewer pipe system, detention ponds and structures, and
inlets is required. For final drainage report, sign, date, and seal the report per
AR State Board of Professional Engineers and Professional Surveyors rules
Article 12, Section B (1) (a). Provide engineer's certification statement saying
this drainage report was conducted by yourself or directly under your
supervision and attesting to the accuracy of the information within this report.
December 8, 2022
ITEM NO.: 5 (Cont.) FILE NO.: Z-8284-A
3
5. The Department requires three (3) phase sediment and erosion control (SEC)
plans to be submitted for all construction projects showing best management
practices (BMPs) for mitigating sediment runoff and erosion along with
vegetation specifications for temporary and permanent soil stabilization.
Phase 1 SEC plans shall show SEC BMPs during the stripping, clearing,
grubbing, and rough grading of the site. Phase 2 SEC plans shall show
SEC BMPs during construction of utilities, buildings, roadway
infrastructure and drainage infrastructure. Phase 3 SEC Plans shall show
SEC BMPs for final grading, seeding, and landscaping of the site.
6. Sediment and Erosion Control plans shall also show the pertinent information
as outlined in ADEQ ARR150000 Permit Part II section A-4-H (1-14) and Part
II section A- 4-I-2 (A-B).
7. Damage to public and private property due to hauling operations or
operations of construction related equipment from a construction site shall be
repaired by the responsible party prior to the issuance of a certificate of
occupancy.
8. Mabelvale Pike is classified as a collector per City’s Master Street Plan.
Therefore, dedicate 30 feet of total, additional right of way from centerline of
Mabelvale Pike or centerline of right of way [depending on location] per
master street plan.
9. Boundary street improvements are required per master street plan on
Mabelvale Pike. Boundary street improvements shall include, but not be
limited to, reconstruction of one- half section of the abutting street if the existing
street is not up to city standards. Repair, replace, or extend existing damaged,
missing, and noncompliant curb and gutter, sidewalk, access ramps or
concrete driveway aprons within the public right-of-way adjacent to the site.
Remove abandoned driveway cuts and replace with curb, gutter, and
sidewalk. All work within the public right-of-way shall conform to City of Little
Rock Public Works Standard Details and ADA guidelines.
10. Per City Code Sec. 31-210 (e) (2), for a collector street driveway spacing shall
be two hundred fifty (250) feet from driveway centerline to centerline.
Minimum driveway spacing from property line shall be one hundred twenty-
five (125) feet. Maximum driveway width is thirty-six (36) feet. A lot will require
six hundred twenty-five (625) feet of frontage for two (2) drives if the lot is
adjacent to an intersection collector street or street of higher classification.
Therefore, revise the site plan in accordance with referenced City Code
requirements. Single driveway shall be aligned with the existing Mabelvale
Drive at the existing intersection, and the proposed driveway width shall be
labeled on the revised site plan.
11. Show and label accessible parking spaces and accessible aisles on site plan.
December 8, 2022
ITEM NO.: 5 (Cont.) FILE NO.: Z-8284-A
4
12. Per City Rev. Code 29-99, stormwater detention for developments is required.
Provide stormwater detention infrastructure to satisfy this requirement.
13. Contact Planning and Development Department Engineering Division at
501-371-4817 or at 501-918-5348 for inspections of any work in the public
right-of-way prior to placement of concrete or asphalt or for on-site
clarification of requirements prior to commencing work. Failure to do so can
result in removal of any improperly placed concrete or asphalt at the expense
of the owner or contractor.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
Entergy: No comments received.
CenterPoint Summit Energy: No comment.
AT & T: No comments received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review.
3. Plan revisions may be required after additional review.
4. Contact Central Arkansas Water regarding procedures for installation of water
facilities and / or fire service.
5. Approval of plans by the Arkansas Department of Health Engineering Division
and Little Rock Fire Department is required.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
December 8, 2022
ITEM NO.: 5 (Cont.) FILE NO.: Z-8284-A
5
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall
not exceed 10 percent in grade except as approved by the fire chief. If the grade
exceeds 10 percent, approval will be denied and the applicant must submit request
to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building
or facilities exceeding 30 feet or three stories in height shall have at least two
means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that
have a single approved fire apparatus access road when all building are equipped
throughout with approved automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1
– D105.4
D105.1 Where Required. Where the vertical distance between the grade plane
and the highest roof surface exceed 30’, approved aerial fire apparatus access
roads shall be provided. For the purposes of this section the highest roof surfaces
shall be determined by measurement to the eave of a pitched roof, the intersection
of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
December 8, 2022
ITEM NO.: 5 (Cont.) FILE NO.: Z-8284-A
6
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting
this condition shall be located within a minimum of 15 feet and a maximum of
30 feet from the building, and shall be positioned parallel to one entire side of the
building. The side of the building on which the aerial fire apparatus access road is
positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over
the aerial fire apparatus access road or between the aerial fire apparatus road and
the building. Other obstructions shall be permitted to be places with the approval
ofthe fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office
(Capt. Tony Rhodes 501-918- 3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1
Parks and Recreation: No comments received.
County Planning: No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
Landscape: The site development must comply with the City’s Landscape
Ordinance (Chapter 15).
G. ANALYSIS:
The applicant is requesting a Conditional Use Permit to allow the use of an existing
C-3 zoned property at 8707 Mabelvale Pike for a new one (1) story 12,500 square
foot Office / Warehouse Facility.
The site is currently undeveloped with the remains of an existing paved drive at
the central north perimeter connecting to Mabelvale Pike. The site is partially tree
covered and slopes slightly from north to south.
The proposed site plan includes a new paved access drive connecting to
Mabelvale Pike at the north central portion of the development with an access
December 8, 2022
ITEM NO.: 5 (Cont.) FILE NO.: Z-8284-A
7
control gate. The site plan shows multi-directional traffic flow lanes around the
perimeter of the property with parking areas circling the new structure. The parking
areas proposed include fifty-one (51) regular spaces, and six (6) large loading zone
parking spaces at the rear (south) of the proposed structure. Staff believes the
proposed parking layout will be sufficient to serve the proposed use.
The proposed site plan shows a new structure centered on the 2.76-acre site. The
applicant states that the new structure will be approximately 12,500 square feet
and be one (1) story in height not to exceed 35’ feet. The structure will contain
approximately 5,000 square feet of single use office space within the north section
of the structure and approximately 7,500 square feet of warehouse in the south
section of the structure.
The site plan shows the new structure setback from the property lines over
70 feet on the north, east, west, and south sides with a water detention area
located at the southwest corner (rear) of the site.
The applicant proposes to provide a twenty-two (22) foot landscape buffer along
the north perimeter of the property adjacent to Mabelvale Pike and seventeen (17)
foot landscape buffers along the east and west perimeters of the property adjacent
to the residential properties. The site must comply with Chapter 15 of the City’s
Landscape Ordinance.
The applicant states that there will be a perimeter fencing around the entire site
with an access-controlled gate at the north access drive connecting to Mabelvale
Pike.
The applicant states that the dumpster for the development will be within a screened
area at the southeast corner of the site.
All site lighting will be low level and directed away from adjacent properties.
No signage is currently proposed for the development. All proposed signage for the
development must conform to Section 36-555 of the City’s Zoning Ordinance. (Signs
allowed in commercial zones).
The applicant states that the new structure will contain a 5,000 square foot single
use office space and a 7,500 square foot material storage warehouse area. The
business will be open Monday – Friday: 7:00 am to 5:00 pm.
The applicant provided responses and additional information to all issues raised
during the staff’s review of the application. To the staff’s knowledge, there are no
outstanding issues.
December 8, 2022
ITEM NO.: 5 (Cont.) FILE NO.: Z-8284-A
8
Staff is supportive of the requested Conditional Use Permit to allow the construction
of a new office / warehouse facility. Staff views the request as reasonable. The
property is in an area surrounded by uses of similar intensity, with similar
commercial developments adjacent to the property to the north, east, and south.
An industrial subdivision is located to the north, across Mabelvale Pike. The
property backs up to mixed Commercial uses along Interstate 30. Staff believes
the proposed development will have no adverse impact on the surrounding
properties.
H STAFF RECOMMENDATION:
Staff recommends approval of the requested Conditional Use Permit to allow the
construction of a new office / warehouse facility subject to compliance with the
comments and conditions outlined in paragraphs D, E, and F, and the staff analysis,
of the agenda staff report.