HomeMy WebLinkAboutZ-5098-B Staff AnalysisFebruary 17, 2000
ITEM NO.: E
NAME: Dillards - Zoning Site Plan Review
LOCATION: 1600 Cantrell Road
DEVELOPER:
ENGINEER:
FILE NO.: Z -5098-B
Dillards, Inc. Architecture Plus
1600 Cantrell Road Washington Plaza, Suite 400
Little Rock, AR 72201 Monroe, LA 71201
AREA: Approx. 14.4 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0
ZONING: 0-2/I-3 ALLOWED USES: Office
PROPOSED USE: Office
VARIANCES/WAIVERS REQUESTED: None requested.
BACKGROUND:
The majority of the property at 1600 Cantrell Road is zoned 0-2
and contains the existing Dillards office building. Based on
the fact that the property is zoned 0-2, the site plan review
process applies for any development.
The 124,155 square foot, 5 -story Dillard's office building is
located within the east one-half of the property, with parking
along its south, east and west sides. A total of 541 parking
spaces exists on the site. The site is heavily landscaped.
Access to the property is gained by utilizing two (2) existing
drives from Cantrell Road.
A. PROPOSAL/REQUEST:
The applicant proposes to add 181,858 square feet of
building space to the existing office building, along its
west side. A portion of the addition will be four (4)
stories in height with the remainder being five (5) levels,
which will be approximately the same height as the existing
building.
February 17, 2000
SUBDIVISION
ITEM NO.: E (Cont.)
FILE NO.: Z -5098-B
The applicant is also proposing to construct a separate
30,000 square foot building within the west one-quarter of
the property. The building will be constructed into the
existing hillside with parking on top. This building will
house the computer equipment for the Dillard's operation.
There are currently 541 parking spaces on the site. The
applicant proposes to add 316 spaces for a total of 857
parking spaces. The additional parking spaces will be
constructed within the eastern and western portions of the
property. The applicant proposes to utilize the two
existing drives from Cantrell Road as access to the
property. The proposed building and parking expansions are
noted on the attached site plan.
B. EXISTING CONDITIONS:
The site contains the existing Dillards office building and
parking areas. There is a mixture of commercial and
industrial uses to the west along the north side of
Cantrell Road.- The Cathedral School development (currently
under construction) is located to the south across Cantrell
Road, with 0-3 zoned property to the east. The Arkansas
River is located immediately north of the site.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received two (2)
informational phone calls regarding this development. The
Downtown and Capitol View-Stifft Station Neighborhood
Associations were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Provide site traffic impact analysis. Verify with plan
and profile that adequate sight distance is provided at
all points of access.
2. Property frontage
brought up to the
3. Repair or replace
is damaged in the
occupancy.
needs to have the sidewalks and ramps
current ADA standards.
any curb and gutter or sidewalk that
public right-of-way prior to
4. Stormwater detention ordinance applies to this property.
5. Easements for proposed stormwater detention facilities
are required.
2
February 17, 2000
SUBDIVISION
ITEM NO.: E (Cont.) FILE NO.: Z -5098-B
6. Existing topographic information at maximum five foot
contour interval 100 base flood elevation.
7. A Sketch Grading and Drainage Plan per Sec. 29-186(e) is
required.
8. A Grading Permit per Secs. 29-186(c) and (d) is
required.
9. A Development Permit for Flood Hazard Area per Sec.
8-283 is required.
10. Contact the ADPC&E for approval prior to start of work
is required.
11. Cantrell Road has average daily traffic of 15,000.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available, not adversely affected.
AP&L : No Comment.
Arkla: No Comment.
Southwestern Bell: No Comment.
Water: Additional on-site fire protection will be
required.
Fire Department: Contact Dennis Free at 918-3752 regarding
turning radii.
County Planning: No Comment.
CATA: Site is served by Route #21. Approved for transit
purposes.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division:
No Comment.
Landscape Issues:
Areas set aside for buffers and landscaping meet with
ordinance requirements.
G. ANALYSIS:
The applicant submitted a revised site plan, south building
elevation and additional information to staff at the
Subdivision Committee meeting. The revised plan and
information addresses most of the staff concerns. The
3
February 17, 2000
SUBDIVISION
ITEM NO.: E (Cont.) FILE NO.: Z -5098-B
revised plan notes the property lines and building heights.
The proposed building setbacks and heights conform to
ordinance standards.
The applicant also included a south elevation of the
property, showing the proposed building and building
additions. The elevation is included on the attached site
plan.
As noted in paragraph A., the applicant proposes to add 316
parking spaces to the site for a total of 857 spaces. The
ordinance requires a minimum of 683 spaces for an office
development of this size. As justification for the number
of parking spaces, the applicant has noted that there will
be a total of 987 employees after the proposed building
expansion. Although rarely, if ever, are all of the
employees at the site at any given time. Staff supports
the parking plan as proposed.
As noted in paragraph D. of this report, Public Works is
requiring a site traffic impact analysis to verify that
adequate sight distance is provided at all points of
access. Public Works had noted concern with the left turn
lane into this site from Cantrell Road (east bound traffic)
being adequate. In a letter to staff, the applicant notes
that Peters and Associates is currently collecting data for
the traffic impact study and will have the information to
present to the Commission at the public hearing.
Otherwise, there should be no outstanding issues associated
with the site plan. The proposed building addition, new
building and parking additions conform to ordinance
standards, and should have no adverse impact on the general
area.
H. STAFF RECOMMENDATIONS:
Staff recommends approval of the site plan subject to the
following conditions:
1. Compliance with the requirements as noted in paragraphs D
and E of this report.
2. The issue related to the traffic impact analysis need to
be resolved.
4
February 17, 2000
SUBDIVISION
ITEM NO.: E (Cont.)
SUBDIVISION COMMITTEE COMMENT:
FILE NO.: Z -5098-B
(DECEMBER 9, 1999)
Joe Story and Michael Kemp were present, representing the
application. Staff briefly described the proposed site plan.
Staff noted that the applicant had submitted a revised site plan
to staff with much of the additional information requested,
including a building elevation and section.
In response to a question, the applicant noted that there would
be a parapet wall around the parking area on top of the smaller
building for safety purposes.
Bob Turner, of Public Works, noted that a traffic impact
analysis was needed. He noted that the existing left turn lane
on Cantrell Road into this site (east bound traffic) was
probably not adequate. This issue was discussed.
Staff requested that the applicant submit
information/justification (number of employees, etc.) for the
total number of proposed parking spaces. This issue was also
briefly discussed.
After the discussion, the Committee forwarded the application to
the full Commission for final action.
PLANNING COMMISSION ACTION:
(JANUARY 6, 2000)
Staff informed the Commission that the applicant submitted a
letter on December 30, 1999 requesting that this item be
deferred to the February 17, 2000 agenda. The applicant failed
to send the required notices to property owners within 200 feet
of the site. Staff supported the deferral request.
The Chairman placed the item before the Commission for inclusion
within the Consent Agenda for deferral to the February 17, 2000
agenda. A motion to that effect was made. The motion passed by
a vote of 11 ayes and 0 nays.
SUBDIVISION COMMITTEE COMMENT:
(JANUARY 27, 2000)
Staff briefly reviewed the revised site plan for this project
with the Committee. It was noted that the proposed computer
5
February 17, 2000
SUBDIVISION
ITEM NO.: E (Cont.) FILE NO.: Z -5098-B
operations building (30,000 square feet) had been removed from
the site plan and would be constructed on a separate property to
the east. A 2,000 square foot maintenance building was shown on
the revised site plan near the west property line. The
maintenance building will be a single story structure and
conforms to the ordinance required minimum setbacks. With the
elimination of the computer operations building, the total
parking for the site has slightly increased from 857 spaces to
883 spaces.
In response to a question from the Committee, Greg Simmons, of
Peters and Associates, noted that a traffic study was being
prepared to address the traffic issues. This was briefly
discussed.
After the brief discussion, the Committee forwarded the
application to the full Commission for final action.
PLANNING COMMISSION ACTION: (FEBRUARY 17, 2000)
The Staff presented a positive recommendation on this
application, as there were no further issues for resolution.
There were no objectors to this matter.
The Chairman placed the item before the Commission for inclusion
within the Consent Agenda for approval as recommended by staff.
A motion to that effect was made. The motion passed by a vote
of 9 ayes, 0 nays and 2 absent.