HomeMy WebLinkAboutZ-4987-G Staff AnalysisITEM NO.: 9.
NAME: Riverdale RH-513 Revised Short -form PCD
Z -4987-G
LOCATION: located on the East side of Riverfront Drive just South of Morgan Keegan Drive
Planning Staff Comments --
1 .
omments:
1. Provide notification of the property owners located within 200 -feet of the site including the
certified abstract list, notice form with affidavit executed and proof of mailing. The notice
must be mailed no later than July 25, 2018. The Office of Planning and Development
must receive the proof of notice no later than August 3, 2018.
2. Provide the days and hours of operation for the business.
3. Will there be a dumpster located on the site? If so provide the location of the proposed
dumpster and a note indicting the screening. Staff recommends the hours of dumpster
service be limited to 7 am to 6 pm Monday through Friday.
4. Provide details of any proposed fences, location, construction material, total height.
5. Provide details of the proposed signage plan including location total height and total sign
area for ground signage. Provide details of the proposed building signage including the
location and total sign area proposed.
6. Provide the maximum building height and the number of stories of the proposed
structures.
VariancefWaivers: Driveway spacing
Engineering Comments:
Public Works Conditions:
1. Sidewalks with appropriate handicap ramps are required in accordance with Section 31-
175 of the Little Rock Code and the Master Street Plan.
2. Repair or replace any curb and gutter or sidewalk that is damaged and not in compliance
with ADA recommendations in the public right-of-way prior to occupancy.
3. Stormwater detention ordinance applies to this property. Show the proposed location for
stormwater detention facilities on the plan. Maintenance of the detention pond and all
private drainage improvements is the responsibility of the developer and/or property
owner association.
4. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the
Arkansas Department of Environmental Quality prior to the start of construction.
5. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by the
responsible party prior to issuance of a certificate of occupancy.
6. Provide ADA compliant sidewalk access from the sidewalk in the right-of-way to the
building.
7. Driveway locations and widths do not meet the traffic access and circulation requirements
of Sections 30-43 and 31-210. Driveway spacing on an arterial street is 150 feet from
ITEM NO.: 9.
Z -4987-G
side property lines and 300 ft from other driveways and intersections. The width of
driveway must not exceed 36 feet. A variance must be requested for the proposed curb
cut for a driveway
Utilities/Fire Department/Parks/County Department/Parks/CountyPlannin
Little Rock Water Reclamation Authority: Sewer main available across Riverfront Drive.
Contact Little Rock Water Reclamation Authority for additional information.
Entergy: Entergy does not object to this proposal. However, caution should be used in the
location of the building as there is a three-phase, underground power line on the eastern side
of this property which serves the entire area. The southeastern corner of the proposed
building is very close to the buried power line and should not inhibit access to the line once
constructed. Contact Entergy in advance to discuss electrical service requirements, line
extensions, or adjustments to existing facilities (if any) as this project proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for water service
must be met.
2. Please submit plans for water facilities and/or fire protection system to Central Arkansas
Water for review. Plan revisions may be required after additional review. Contact Central
Arkansas Water regarding procedures for installation of water facilities and/or fire service.
Approval of plans by the Arkansas Department of Health Engineering Division and the
Little Rock Fire Department is required.
3. Contact Central Arkansas Water regarding the size and location of the water main.
4. A main extension will be required for this project.
5. The facilities on-site will be private. When meters are planned off private lines, private
facilities shall be installed to Central Arkansas Water's materials and construction
specifications and installation will be inspected by an engineer, licensed to practice in the
State of Arkansas. Execution of a Customer Owned Line Agreement is required.
6. Due to the nature of this facility, installation of an approved reduced pressure zone
backflow preventer assembly (RPZA) is required on the domestic water service. This
assembly must be installed prior to the first point of use. Central Arkansas Water requires
that upon installation of the RPZA, successful tests of the assembly must be completed by
a Certified Assembly Tester licensed by the State of Arkansas and approved by Central
Arkansas Water. The test results must be sent to Central Arkansas Water's Cross
Connection Section within ten days of installation and annually thereafter. Contact the
Cross Connection Section at 501.377.1226 if you would like to discuss backflow
prevention requirements for this project.
ITEM NO.: 9. Z -4987-G
7. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated
with a double detector check valve assembly. If additives are used, a reduced pressure
zone back flow preventer shall be required.
Fire Department:
1. Full Plan Review — Maintain Access
2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access
road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road,
the minimum road width shall be 26 feet, exclusive of shoulders.
3. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not
exceed 10 percent in grade except as approved by the fire chief.
4. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities,
buildings or portions of buildings hereafter constructed shall be accessible to fire
department apparatus by way of an approved fire apparatus access road with an asphalt,
concrete or other approved driving surface capable of supporting the imposed load of fire
apparatus weighing at least 75,000 pounds.
5. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus
access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
a. Section D104.1 Buildings exceeding three stories or 30 feet in height. Building
or facilities exceeding 30 feet or three stories in height shall have at least two
means of fire apparatus access for each structure.
b. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
c. Exception: Projects having a gross building area of up to 124,000 square feet
that have a single approved fire apparatus access road when all building are
equipped throughout with approved automatic sprinkler systems.
d. D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of
the maximum overall diagonal dimension of the lot or area to be served,
measured in a straight line between accesses.
6. 30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1 — D105.4
a. D105.1 Where Required. Where the vertical distance between the grade plane
and the highest roof surface exceed 30', approved aerial fire apparatus access
roads shall be provided. For the purposes of this section the highest roof
surfaces shall be determined by measurement to the eave of a pitched roof, the
ITEM NO.: 9-
7
0
Z -4987-G
intersection of a roof to the exterior wall, or the top of the parapet walls,
whichever is greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
c. D105.3 Proximity to building. At least one of the required access routes meeting
this condition shall be located within a minimum of 15 feet and a maximum of
30 feet from the building, and shall be positioned parallel to one entire side of
the building. The side of the building on which the aerial fire apparatus access
road is positioned shall be approved by the fire code official.
d. D105.4 Obstructions. Overhead utility and power lines shall not be located over
the aerial fire apparatus access road or between the aerial fire apparatus road
and the building. Other obstructions shall be permitted to be places with the
approval of the fire code official.
Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-
end fire apparatus access roads in excess of 150 feet shall be provided with width and
turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire
apparatus access roads.
Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates.
Gates securing the fire apparatus access roads shall comply with all of the following
criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times and
replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices shall
be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code
official
8. Electric gate operators, where provided, shall be listed in accordance with UL
325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
ITEM NO.: 9.
Z -4987-G
9. Lire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water
(Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony
Rhodes 501.918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution of
Fire Hydrants as per Table C105.1.
Parks and Recreation: Consideration for sidewalks parallel to Riverfront Drive. For
additional information contact the Parks Department, Leland Couch.
County Planning: No comment.
Building Codes/Landscape:
Building Code: Project is subject to full commercial plan review and approval prior to
issuance of a building permit. For information on submittal requirements and the review
process. This project will require fully developed Architectural, Structural, Civil and MEP
Plans. Contact a commercial plans examiner: Curtis Richey at 501.371.4724;
crichey@1 ttlerock,gov
Landscape:
1. Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
2. Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
3. A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street, highway or freeway. This strip shall be
at least nine (9) feet wide. Provide trees with an average linear spacing of not less than
thirty (30) feet within the perimeter planting strip. Provide three (3) shrubs or vines for
every thirty (30) linear feet of perimeter planting strip.
4. Landscape areas shall be provided between the vehicular use area used for public
parking and the general vicinity of the building, excluding truck loading or service areas
not open to public parking. These areas shall be equal to an equivalent planter strip three
(3) feet wide along the vehicular use area.
5. Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The minimum
size of an interior landscape area shall be one hundred fifty (150) square feet for
developments with one hundred fifty (150) or fewer parking spaces. Interior islands must
be a minimum seven and one half (7 1/2) feet in width. Trees shall be included in the
interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces.
6. A landscape irrigation system shall be required for developments of one (1) acre or larger.
7. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
ITEM NO.: 9.
Transportation/Plan n i n g:
Z -4987-G
Rock Region Metro: The site is not located near a dedicated Rock Region Metro Route -
Planning Division: This request is located in the Heights Hillcrest Planning District. The Land
Use Plan shows Mixed Use (MX) for this property. The Mixed Use category provides for a
mixture of residential, office and commercial uses to occur. A Planned Zoning District is
required if the use is entirely office or commercial or if the use is a mixture of the three. The
applicant has applied for a revised to PCD (Planned Commercial Development) to allow
approval of a site plan for an office building
Master Street Plan: To the west of the property is Riverfront Drive and it is shown as a Minor
Arterial on the Master Street Plan. A Minor Arterial provides connections to and through an
urban area and their primary function is to provide short distance travel within the urbanized
area. Entrances and exits should be limited to minimize negative effects on traffic and
pedestrians on Riverfront Drive since it is a Minor Arterial. This street may require dedication
of right-of-way and may require street improvements for entrances and exits to the site.
Bicvcle Plan: A Class II Bike Lane is shown along Riverfront Drive. Bike Lanes provide a
portion of the pavement for the sole use of bicycles.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the
additional information as noted above) to staff on Wednesday, July 25, 2018.
FILE NO.: Z -4987-G
NAME: Riverdale RH-513 Revised Short -form PCD
LOCATION: Located on the East side of Riverfront Drive just South of Morgan Keegan
Drive
DEVELOPER:
EHB, LLC
5200 Sherwood Road
Little Rock, AR 72207
OWNER/AUTHORIZED AGENT:
EHB, LLC, (Purchase Agreement)
White-Daters and Associates, Agent
SURVEYOR/ENGINEER:
White-Daters and Associates
24 Rahling Circle
Little Rock, AR 72223
AREA: 1.2 -acres NUMBER OF LOTS: 1 FT. NEW STREET. 0 LF
WARD: 3 PLANNING DISTRICT: 4 — Heights Hillcrest CENSUS TRACT: 15.02
CURRENT ZONING: PCD
ALLOWED USES: Retail, Office, Multi -family, Marina
PROPOSED ZONING: Revised PCD
PROPOSED USE: Office
VARIANCE/WAIVERS: A variance from Sections 30-43 and 31-210 to allow the northern
driveway less than 150 -feet from the property line.
FILE NO.: Z -4987-G (Cont.
BACKGROUND:
The development was approved for a multiple lot development by the adoption of
Ordinance No. 15,459 on April 19, 1988, which allowed the rezoning of 40+ acres from
0-2, Office and Institutional District to PCD, Planned Commercial Development District.
The approved site plan included the development of multi -family residential, office and
commercial uses all centered on a waterfront harbor. Subsequent revisions have allowed
the development of the site with office and residential uses.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT.-
The
TATEMENT:
The property is currently zoned PCD, Planned Commercial Development District,
and was part of the original Riverdale Harbor development. The developer is
proposing a single story, 8,400 square foot professional office. The surrounding
properties are also developed with office users. Parking is more than adequate
with 24 proposed parking spaces and an area for 12 future parking spaces along
Riverfront Drive should a future tenant need additional parking spaces. The
developer is requesting a variance for driveway spacing to allow a right -out
driveway to facilitate traffic circulating within the parking areas. Riverfront Drive is
a divided parkway which will eliminate left turns to and from this proposed
driveway. The proposed driveway will be 180 -feet from the driveway to the south
and 330 -feet from Morgan Keegan Drive to the north.
The developer is requesting in -lieu stormwater detention. This property is part of
the Riverdale Levee District which was designed for developed conditions and
eliminates the need for detention on individual lots. The in -lieu fee could be used
by the City for other drainage improvements in the area.
B. EXISTING CONDITIONS:
The property is located in the Riverdale Neighborhood of the City. The site is grass
covered with a couple of large diameter trees. There is an office building located
to the north of this site and the previously proposed and developed harbor is
located to the west of this site. The Park at Riverdale Apartments are located to
the west of this site and Riverwalk Apartments are located to the north of this site.
Winrock International offices are located to the south of this site and will share a
common driveway. Riverfront Drive is a developed street with curb, gutter and a
paved walking path.
C. NEIGHBORHOOD COMMENTS:
All property owners located within 200 -feet of the site along with Riverside
Neighborhood Association were notified of the public hearing.
2
FILE NO.: Z -4987-G
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Sidewalks with appropriate handicap ramps are required in accordance with
Section 31-175 of the Little Rock Code and the Master Street Plan.
2. Repair or replace any curb and gutter or sidewalk that is damaged and not in
compliance with ADA recommendations in the public right-of-way prior to
occupancy.
3. Stormwater detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan. Maintenance of the
detention pond and all private drainage improvements is the responsibility of
the developer and/or property owner association.
4. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit
from the Arkansas Department of Environmental Quality prior to the start of
construction.
5. Damage to public and private property due to hauling operations or operation
of construction related equipment from a nearby construction site shall be
repaired by the responsible party prior to issuance of a certificate of occupancy.
6. Provide ADA compliant sidewalk access from the sidewalk in the right-of-way
to the building.
7. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. Driveway spacing on an arterial
street is 150 feet from side property lines and 300 feet from other driveways
and intersections. The width of driveway must not exceed 36 feet. A variance
must be requested for the proposed curb cut for a driveway.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: Sewer main available across Riverfront
Drive. Contact Little Rock Water Reclamation Authority for additional information.
Entergy: Entergy does not object to this proposal. However, caution should be
used in the location of the building as there is a three-phase, underground power
line on the eastern side of this property which serves the entire area. The
southeastern corner of the proposed building is very close to the buried power line
and should not inhibit access to the line once constructed. Contact Entergy in
advance to discuss electrical service requirements, line extensions or adjustments
to existing facilities (if any) as this project proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
3
FILE NO.: Z -4987-G (Cont.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional
review. Contact Central Arkansas Water regarding procedures for installation
of water facilities and/or fire service. Approval of plans by the Arkansas
Department of Health Engineering Division and the Little Rock Fire Department
is required.
3. Contact Central Arkansas Water regarding the size and location of the
water main.
4. A main extension will be required for this project.
5. The facilities on-site will be private. When meters are planned off private lines,
private facilities shall be installed to Central Arkansas Water's materials and
construction specifications and installation will be inspected by an engineer,
licensed to practice in the State of Arkansas. Execution of a Customer Owned
Line Agreement is required.
6. Due to the nature of this facility, installation of an approved reduced pressure
zone backflow preventer assembly (RPZA) is required on the domestic water
service. This assembly must be installed prior to the first point of use. Central
Arkansas Water requires that upon installation of the RPZA, successful tests
of the assembly must be completed by a Certified Assembly Tester licensed by
the State of Arkansas and approved by Central Arkansas Water. The test
results must be sent to Central Arkansas Water's Cross Connection Section
within ten days of installation and annually thereafter. Contact the Cross
Connection Section at 501.377.1226 if you would like to discuss backflow
prevention requirements for this project.
7. Fire sprinkler systems which do not contain additives such as antifreeze shall
be isolated with a double detector check valve assembly. If additives are used,
a reduced pressure zone back flow preventer shall be required.
Fire Department:
1. Full Plan Review — Maintain Access
2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is located on a
fire apparatus access road, the minimum road width shall be 26 feet, exclusive
of shoulders.
3. Grade. Maintain fire apparatus access roads as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire
apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
4
FILE NO.: Z -4987-G (Cont.
4. Loading. Maintain fire apparatus access road design as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and
loading. Facilities, buildings or portions of buildings hereafter constructed shall
be accessible to fire department apparatus by way of an approved fire
apparatus access road with an asphalt, concrete or other approved driving
surface capable of supporting the imposed load of fire apparatus weighing at
least 75,000 pounds.
5. Commercial and Industrial Developments — 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1
a. Section D104.1 Buildings exceeding three stories or 30 feet in height.
Building or facilities exceeding 30 feet or three stories in height shall
have at least two means of fire apparatus access for each structure.
b. Section D104.2 Building exceeding 62,000 square feet in area.
Buildings or facilities having a gross building area of more than
62,000 square feet shall be provide with two separate and approved
fire apparatus access roads.
c. Exception: Projects having a gross building area of up to
124,000 square feet that have a single approved fire apparatus
access road when all building are equipped throughout with
approved automatic sprinkler systems.
d. D104.3 Remoteness. Where two fire apparatus access roads are
required, they shall be placed a distance apart equal to not less than
one half of the length of the maximum overall diagonal dimension of
the lot or area to be served, measured in a straight line between
accesses.
6. 30' Tall Buildings -Maintain aerial fire apparatus access roads as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1 — D105.4
a. D105.1 Where Required. Where the vertical distance between the
grade plane and the highest roof surface exceed 30', approved aerial
fire apparatus access roads shall be provided. For the purposes of
this section the highest roof surfaces shall be determined by
measurement to the eave of a pitched roof, the intersection of a roof
to the exterior wall, or the top of the parapet walls, whichever
is greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a
minimum unobstructed with of 26', exclusive of shoulders, in the
immediate vicinity of the building or portion thereof.
c. D105.3 Proximity to building. At least one of the required access
routes meeting this condition shall be located within a minimum of
15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the
building on which the aerial fire apparatus access road is positioned
shall be approved by the fire code official.
5
FILE NO.: Z -4987-G (Cont.
d. D105.4 Obstructions. Overhead utility and power lines shall not be
located over the aerial fire apparatus access road or between the
aerial fire apparatus road and the building. Other obstructions shall
be permitted to be places with the approval of the fire code official.
7. Dead Ends. Maintain fire apparatus access roads at dead end locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4
Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall
be provided with width and turnaround provisions in accordance with Table
D103.4. Requirements for Dead-end fire apparatus access roads.
8. Gates. Maintain fire apparatus access road gates as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus
access road gates. Gates securing the fire apparatus access roads shall
comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation
by one person.
4. Gate components shall be maintained in an operable condition at all
times and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by
fire department personnel for emergency access. Emergency
opening devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain
and padlock unless they are capable of being opened by means of
forcible entry tools or when a key box containing the keys to the lock
is installed at the gate location.
7. Locking device specifications shall be submitted for approval by the
fire code official
8. Electric gate operators, where provided, shall be listed in accordance
with UL 325.
9. Gates, intended for automatic operation shall be designed,
constructed and installed to comply with requirements of ASTM F
2200.
9. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas
Fire Prevention Code. Section C101 — C105, in conjunction with Central
Arkansas Water (Jason Lowder 501.377.1245) and the Little Rock Fire
Marshal's Office (Capt. Tony Rhodes 501.918.3757 or Capt. John Hogue
501.918.3754). Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: Consideration should be given for sidewalks parallel to
Riverfront Drive. For additional information contact the Parks Department, Leland
Couch.
1.1
FILE NO.: Z -4987-G (Cont.
County Planning: No comment.
F. BUILDING CODES/LANDSCAPE:
Building Code: Project is subject to full commercial plan review and approval prior
to issuance of a building permit. For information on submittal requirements and the
review process. This project will require fully developed Architectural, Structural,
Civil and MEP Plans. Contact a commercial plans examiner: Curtis Richey at
501.371.4724; crichey_§Httlerock go_v.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements.
2. Screening requirements will need to be met for the vehicular use areas
adjacent to street right-of-ways. Provide screening shrubs with an average
linear spacing of not less at three (3) feet within the required landscape area.
Provide trees with an average linear spacing of not less than thirty (30) feet.
3. A perimeter planting strip is required along any side of a vehicular use area that
abuts adjoining property or the right-of-way of any street, highway or freeway.
This strip shall be at least nine (9) feet wide. Provide trees with an average
linear spacing of not less than thirty (30) feet within the perimeter planting strip.
Provide three (3) shrubs or vines for every thirty (30) linear feet of perimeter
planting strip.
4. Landscape areas shall be provided between the vehicular use area used for
public parking and the general vicinity of the building, excluding truck loading
or service areas not open to public parking. These areas shall be equal to an
equivalent planter strip three (3) feet wide along the vehicular use area.
5. Eight percent (8%) of the vehicular use area must be designated for green
space; this green space needs to be evenly distributed throughout the parking
area(s). The minimum size of an interior landscape area shall be one hundred
fifty (150) square feet for developments with one hundred fifty (150) or fewer
parking spaces. Interior islands must be a minimum seven and one half (7 1/2)
feet in width. Trees shall be included in the interior landscape areas at the rate
of one (1) tree for every twelve (12) parking spaces.
6. A landscape irrigation system shall be required for developments of one
(1) acre or larger.
7. The City Beautiful Commission recommends preserving as many existing trees
as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
7
FILE NO.: Z -4987-G Cont.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: The site is not located near a dedicated Rock Region Metro
Route.
Planning Division: This request is located in the Heights Hillcrest Planning District.
The Land Use Plan shows Mixed Use (MX) for this property. The Mixed Use
category provides for a mixture of residential, office and commercial uses to occur.
A Planned Zoning District is required if the use is entirely office or commercial or if
the use is a mixture of the three. The applicant has applied for a revision to a PCD
(Planned Commercial Development) to allow approval of a site plan for an office
building
Master Street Plan: To the west of the property is Riverfront Drive and it is shown
as a Minor Arterial on the Master Street Plan. A Minor Arterial provides
connections to and through an urban area and their primary function is to provide
short distance travel within the urbanized area. Entrances and exits should be
limited to minimize negative effects on traffic and pedestrians on Riverfront Drive
since it is a Minor Arterial. This street may require dedication of right-of-way and
may require street improvements for entrances and exits to the site.
Bicycle Plan: A Class II Bike Lane is shown along Riverfront Drive. Bike Lanes
provide a portion of the pavement for the sole use of bicycles.
H. SUBDIVISION COMMITTEE COMMENT: (July 18, 2018)
Mr. Joe White of White-Daters and Associates was present representing the
request. Staff presented an overview of the item stating there were few
outstanding technical issues associated with the request. Staff requested
Mr. White provide the proposed signage plan, any proposed fencing and the
location of any proposed dumpsters. Staff also requested Mr. White provide the
maximum building height of the new office building.
Public Works comments were addressed. Staff questioned the need for the
additional driveway on the northern portion of the site. Mr. White stated the drive
would allow for better circulation on the site. He stated the drive was indicated as
a right-in/right-out driveway due to the fact a left turn would not be allowed since
there was not a median break. Staff stated a sidewalk along Riverfront Drive was
required. Staff stated the City's Stormwater Detention Ordinance would apply to
the future development of the site.
Landscaping comments were addressed. Staff stated the indicated street buffer
appeared to comply with the typical minimum standards of the ordinance. Staff
stated screening of the parking areas would be required with the development of
the site. Staff stated building landscaping was required. Staff stated a minimum
of eight percent (8%) of the vehicular use areas were to be landscaped.
N
FILE NO.: Z -4987-G (.Cont.
Staff noted the comments from the various other departments and agencies. Staff
suggested the applicant contact the departments or agencies directly with any
questions or concerns. There were no more issues for discussion. The Committee
then forwarded the item to the full Commission for final action.
ANALYSIS:
The applicant submitted a revised site plan and cover letter to staff addressing the
technical issues associated with the request as outlined in the July 18, 2018,
Subdivision Committee meeting. The applicant has indicated no fencing it
proposed. The applicant has also indicated the proposed signage plan and the
location of the proposed dumpster.
The applicant is requesting to amend the previously approved PCD, Planned
Commercial Development, to allow the development of the property with an office
building. The developer is proposing a single story, 8,400 square foot professional
office. The maximum building height proposed is 35 -feet.
Parking is proposed with 24 parking spaces and an area for 12 future parking
spaces along Riverfront Drive should a future tenant need additional parking
spaces. Parking for an office use would typically require the placement of
21 parking spaces.
The applicant is proposing the placement of a single identification sign along
Riverfront Drive. The sign is proposed with a maximum height of six (6) feet and
a maximum sign area of 64 square feet.
The applicant submitted a revised site plan eliminating the request for a right -in
drive on Riverfront Drive. The request now is for the placement of a right -out only
driveway on Riverfront Drive. The developer is requesting a variance for driveway
spacing to allow the right -out driveway on Riverfront Drive. Riverfront Drive is a
divided parkway which will eliminate left turns to and from this proposed driveway.
The proposed driveway will be 180 -feet from the driveway to the south and
330 -feet from Morgan Keegan Drive to the north. Staff is supportive of the
applicant's request.
The developer is requesting in -lieu stormwater detention. This property is part of
the Riverdale Levee District which was designed for developed conditions and
eliminates the need for detention on individual lots.
Staff is supportive of the applicant's request. The applicant is seeking to amend
the previously approved PCD, Planned Commercial Development District, to allow
the approval of a site plan for an existing lot located in the Riverdale Neighborhood.
The office building is proposed as a single story building. The parking and
landscaping appear to comply with the typical development standards of the
zoning and landscape ordinances. Staff feels the development as proposed is
appropriate for the site.
9
FILE NO.: Z -4987-G (C
J. STAFF RECOMMENDATION.
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda staff
report.
Staff recommends approval of the variance request from Sections 30-43 and
31-210 to allow the northern drive as indicated on the site plan.
PLANNING COMMISSION ACTION: (AUGUST 9, 2018)
The applicant as present. There were no registered objectors present. Staff presented
the item with a recommendation of approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda staff report.
Staff presented a recommendation of approval of the variance request from Sections
30-43 and 31-210 to allow the northern drive as indicated on the site plan. There was no
further discussion. The item was placed on the consent agenda and approved as
recommended by staff by a vote of 10 ayes, 0 noes and 1 absent.
10