HomeMy WebLinkAboutApplicationLittle Rock
HISTORIC
DISTRICT
COMMISSION
DEPARTMENT OF PLANNING AND DEVELOPMENT
723 West Markham Street
Little Rock, Arkansas 72201-1334
Ph one: (501) 371-4790 Fax: (501) 399-3435
APPLICATION FOR A
CERTIFICATE OF APPROPRIATENESS
1.Application Date::s C\ lD\b
2.Date of Public Hearing:\ 'is \\ at 5:00 p.m.
3.Address of Property: CS \ GGJ:. <:,tt.R<,,,,T° L \-1 .A. '2.. :J l. b
4.Legal Description of Property: S -o }..T -0 \ JJ I< - \ vJ
lv\'T .}.A (06r-J. 1r- -e. -""2-,s -5b I oBS \.:> - sS'j:)bOlj
5.Property Owner (Printed Name, Address, Phone, Email): ______________
\.Q,t \<.e -s O \ G. "l \- LR .A -n. "2.,o '- 5 <:.' b O "SC,
h't"..e...,...l ..., '("« -\.\ ?o\ -, o-\8\S· · br.g."'-J.cio,. a;"'.\@(; \,
6.Owner's Agent: (Printed Name, Address, Phone, Email): ______________
7.Brief Project Description: lt:> w 6"".r u.\..t. l-.l .,.. J. <; .
(> 1..A • ... -J..o s <..> ' <A {?v"y"1 J -S.0-.:).:s.. /
8.Estimatea Cost of lmprovements:._'5_ ...... 'ri,11..\_,_,.........,,. ,,__a.,::_:_ _,_ ________________ _
9.Zoning Classification: Is the proposed chan
1 0.Signature of Owner or Agent:. __ ....£.::.:..........:..;....:...;. :..!...:: ::....._-- B:t. ,,L.:::. '-'L(:;,oL ---
(The owner will need to authorize any Agen or person representing the owner at th
NOTE: Should there be changes during construction (design, materials, size, etc.) from the approved COA,
applicant shall notify Commission staff and take appropriate actions. Approval by the Commission does not
excuse applicant or property from compliance with other applicable codes, ordinances or policies of the city
unless stated by the Commission or staff. Responsibility for identifying such codes, ordinances, or policies rests
with the applicant, owner, or agent.
(This section to be completed by staff):Little Rock Historic District Commission Action
_ Denied _ Withdrawn _ Approved _ Approved with Conditions _ See Attached Conditions
Staff Signature: Date: ·-----------------------------
Revised 8/2012
Brenda & Terry Kent
501 East 7th St.1501-680-18981 brendakent53@gmail.com
June 10, 2016
Brian Minyard
Planner 11
Planning and Development Department
723 West Markham St
Little Rock, AR 72201
Dear Brian:
Please find attached the application for a Certificate of Appropriateness (COA), and the supporting documents for the
proposed window replacement for the property located at 501 East 7th Street in Little Rock, AR.
We propose to remove the security bars from all the existing windows, and replace all of the existing windows with Little
Rock Historic District Commission approved windows. The need to replace the windows is based on the following
determinations:
1.Some of the existing windows and the frames around them have rotted over the years.
2.There is a safety concern regarding escape in case of fire. The existing windows are difficult to open and we are
retired senior citizens who often keep our young granddaughters and our adult autistic grandson.
3.The older single pane windows are energy inefficient and the replacements will provide considerable cost
savings on energy into the future and will reduce our carbon foot print.
We understand that to replace these windows with the historically approved windows will be a big expense, but
we believe that with the continued investment in the neighborhood by other neighbors and developers that it is
our responsibility as property owners to better the house and the neighborhood,
Sincerely,
Brenda & Terry Kent
Version 8.5.5
WINDOWS, DOORS, & MORE, INC.
Quote Date
21140-A INTERSTATE 30
BRYANT, AR 72022
501-315-3300
501-315-3081
Prep By Bid No Rev Job Reference
GRA 828 1
Customer I Client Name
Mccarley Home Improvement
Job I Site Name
5/18/2016 501 E 7th St., LR
Phone#
Mobile Phone # Other Phone #
LINCOLN WINDOWS
Fax#
Email Address
Quality Craftsmanship Since 194 7
LINCOLN WOOD PRODUCTS, INC.
Prepared By : WINDOWS, DOORS, & MORE, INC.
R Quote # GRA-828-1 —
Rough Opening Allowance = 1/2 Inch
McCarley Home Improvement
Page
SHOWN AT NET PRICE
Line # 1
R.O. 45-7/8" x 57-1/2"
O.A. Box Size 45-3/8x57"
Line # 2
R.O. 30-1 /8" x 41-1 /4"
O.A. Box Size 29-5/8x40-3/4"
(Continued On Next Page)
DBLH-1; 40x24-1/4; Primed Wood
Exterior; LoE-272
Custom Height
1 White Screen(s) Applied
BETTERVUE Mesh
Custom Screen
Preserve Glass (Top)
7/8" SDL (Top) (4W2H) Profiled
Interior - With Mill Finish Internal
Grids
Preserve Glass (Bottom)
7/8" SDL (Bottom) (4W2H)
Profiled Interior - With Mill Finish
Internal Grids
6-9/16" Jamb Extension Applied
Standard PVC Brickmould
Prep For Stool
** This Unit Is Not Certified Due To
Prep For Stool Option **
Faux Bronze Hardware
White Jambliners
Primed Jambliner Covers
With T Slot Weatherstrip In
Jambliner
Sash 1
U-Factor-0.3
SHGC=0.27
Visible Transmittance=0.46
PG=N/A
Maximum Width Available
DBLH-1; 24-11406-1/8; Primed
Wood Exterior; LoE-272
Custom Width
Custom Height
1 White Screen(s) Applied
BETTERVUE Mesh
Custom Screen
Preserve Glass (Top)
7/8" SDL (Top) (3W2H) Profiled
Interior - With Mill Finish Internal
Grids
Preserve Glass (Bottom)
7/8" SDL (Bottom) (3W2H)
Profiled Interior - With Mill Finish
Internal Grids
6-9/16" Jamb Extension Applied
Standard PVC Brickmould
Prep For Stool
** This Unit Is Not Certified Due To
Prep For Stool Option **
Faux Bronze Hardware
White Jambliners
Primed Jambliner Covers
Quantity: 7
Quantity: 2
Version 8.5.5 Prepared By: WINDOWS, DOORS, S MORE, INC.
Quote # GRA-828-1 McCarley Home Improvement
n
(Continued From Previous Page)
Page
With T Slot Weatherstrip In
Jambliner
Sash 1
U-Factor=0.3
SHGC=0.27
Visible Transmittance=0.46
PG=N/A
Line # 3
• DBLH-2; 30-9/16x24-1/8; Primed
Wood Exterior; LoE-272
.
Custom Width
Custom Height
2 White Screen(s) Applied
-
BETTERVUE Mesh
Custom Screen
Preserve Glass (Top)
R.O. 72-3/8" x 57-114"
7/8" SDL (Top) (3W2H) Profiled
O.A. Box Size 71-7/8x56-3/4"
interior -With Mill Finish Internal
Grids
Preserve Glass (Bottom)
7/8" SDL (Bottom) (3W2H)
Profiled Interior - With Mill Finish
Internal Grids
Mulling Charge
6-9116" Jamb Extension Applied
Standard PVC Brickmould
Prep For Stool
** This Unit Is Not Certified Due To
Prep For Stool Option **
Faux Bronze Hardware
White Jambliners
Primed Jambliner Covers
With T Slot Weatherstrip In
Jambliner
Vertical Interior Mull Casing
Sash 1
U-Factor-0.3
SHGC=0.27
Visible Transmittance=0.46
PG=N/A
Quantity: 1
Version 8.5.5 Prepared By: WINDOWS, DOORS, & MORE, INC.
Quote # GRA-828-1 McCarley Home Improvement
- -- ---
Page
Line # 4
• DBLH-1; 40x24-1/8; Primed Wood
Exterior; LoE-272
Custom Height
1 White Screen(s) Applied
BETTERVUE Mesh
Custom Screen
Preserve Glass (Top)
7/8" SDL (Top) (4W2H) Profiled
R.O.45-7/8" x 57-1/4"
Interior - With Mill Finish Internal
O.A. Box Size 45-3/8x56-314"
Grids
Preserve Glass (Bottom)
7/8" SDL (Bottom) (4W2H)
Profiled Interior - With Mill Finish
Internal Grids
6-9116" Jamb Extension Applied
Standard PVC Brickmould
Prep For Stool
** This Unit Is Not Certified Due To
Prep For Stool Option **
Faux Bronze Hardware
White Jambliners
Primed Jambliner Covers
With T Slot Weatherstrip In
Jambliner
Sash 1
U-Factor-0.3
SHGC=0.27
Visible Transmittance=0.46
PG=N/A
Maximum Width Available
Line # 5
• DBLH-1; 32-1/4x16-1/8; Primed
Wood Exterior; LoE-272
Custom Width
Custom Height
1 White Screen(s) Applied
BETTERVUE Mesh
R.O. 38-1/8" x 41-1/4"
Custom Screen
O.A. Box Size 37-5/8x40-3/4"
Preserve Glass (Top)
7/8" SDL (Top) (3W2H) Profiled
Interior - With Mill Finish Internal
Grids
Preserve Glass (Bottom)
7/8" SDL (Bottom) (3W2H)
Profiled Interior - With Mill Finish
Internal Grids
6-9/16" Jamb Extension Applied
Standard PVC Brickmould
Prep For Stool
** This Unit Is Not Certified Due To
Prep For Stool Option **
Faux Bronze Hardware
White Jambliners
Primed Jambliner Covers
With T Slot Weatherstrip In
Jambliner
Quantity: 1
Quantity: 1
(Continued On Next Page)
Version 8.5.5 Prepared By: WINDOWS, DOORS, & MORE, INC.
Quote # GRA-828-1 McCarley Home Improvement
INE
(Continued From Previous Page)
Page
Sash 1
U-Factor=0.3
SHGC=0.27
Visible Transmittance=0.46
PG=N/A
Line # 6
• DBLH-1; 24-1/4x20-1/8; Primed
Wood Exterior; LoE-272
Custom Width
Custom Height
1 White Screen(s) Applied
BETTERVUE Mesh
Custom Screen
R.O. 30-1/8" x 49-1/4"
Preserve Glass (Top)
O.A. Box Size 29-5/8x48-3/4"
7/8" SDL (Top) (3W2H) Profiled
Interior - With Mill Finish Internal
Grids
Preserve Glass (Bottom)
7/8" SDL (Bottom) (3W2H)
Profiled Interior - With Mill Finish
Internal Grids
6-9116" Jamb Extension Applied
Standard PVC Brickmould
Prep For Stool
** This Unit Is Not Certified Due To
Prep For Stool Option **
Faux Bronze Hardware
White Jambliners
Primed Jambliner Covers
With T Slot Weatherstrip In
Jambliner
Sash 1
U-Factor=0.3
SHGC=0.27
Visible Transmittance=0.46
PG=N/A
Line # 7
• DBLH-1; 26-1/2xl8-3/4; Primed
Wood Exterior; LoE-272
Custom Width
Custom Height
1 White Screen(s) Applied
BETTERVUE Mesh
Custom Screen
R.O.32-318" x 46-1/2"
Preserve Glass (Top)
O.A. Box Size 31-7/8x46"
7/8" SDL (Top) (3W2H) Profiled
Interior - With Mill Finish Internal
Grids
Preserve Glass (Bottom)
(Continued On Next Page)
Version 8.5.5
Prepared By: WINDOWS, DOORS, & MORE, INC.
Quantity: 2
Quantity: 1
Quote # GRA-828-1 McCarley Home Improvement
991
(Continued From Previous Page)
Page
7/8" SDL (Bottom) (3W2H)
Profiled Interior - With Mill Finish
Internal Grids
6-9116" Jamb Extension Applied
Standard PVC Brickmould
Prep For Stool
** This Unit Is Not Certified Due To
Prep For Stool Option **
Faux Bronze Hardware
White Jambliners
Primed Jambliner Covers
With T Slot Weatherstrip In
Jambliner
Sash 1
U-Factor=0.3
SHGC=0.27
Visible Transmittance=0.46
PG=N/A
Upstairs - Replacement for
Aluminum Window
Line # 8
• DBLH-1; 30x13-3/8; Primed Wood
Exterior; LoE-272
Custom Height
1 White Screen(s) Applied
BETTERVUE Mesh
R.O. 35-7l8" x 35-3/4" Custom Screen
O.A. Box Size 35-3/114" Preserve Glass (Top)
7/8" SDL (Top) (3W2H) Profiled
Interior - With Mill Finish Internal
Grids
Preserve Glass (Bottom)
7/8" SDL (Bottom) (3W2H)
Profiled Interior- With Mill Finish
Internal Grids
6-9116" Jamb Extension Applied
Standard PVC Brickmould
Prep For Stool
`* This Unit Is Not Certified Due To
Prep For Stool Option *"
Faux Bronze Hardware
White Jambliners
Primed Jambliner Covers
With T Slot Weatherstrip In
Jambliner
Sash 1
U-Factor=0.3
SHGC=0.27
Visible Transmittance=0.46
PG=NIA
Upstairs - Replacement for Vinyl
Window
Quantity: 1
Version 8.5.5 Prepared By: WINDOWS, DOORS, & MORE, INC.
quote # GRA-828-1
-
Line # 9
Distributor Item
Line # 10
Distributor Item
McCarley Home Improvement
• MATERIAL; Trim (444FJ), Chaulk, Quantity: 1
Window Stools (1021FJPR)
• CONTRACT LABOR; Quantity: 1
Replacement for windows.
Includes new interior casing and
window stools.
Quoted prices are good for 30 days (Expires: 6/1712016) TOTAL NET PRICE
and are subject to correction of computational errors. STATE SALES TAX (Taxable Amt: $19,843.49)
COUNTY SALES TAX (Taxable Amt: $19,843.49)
CITY TAX (Taxable Amt: $19,843.49)
TOTAL QUOTATION PRICE
I have reviewed the preceding quotation, verified the quantities, sizes, color, grills, glass, and all
other relevant information and find it acceptable. by signing below I authorize Windows, Doors,
& More, Inc. to proceed with the purchase of the items herein. All items are special order and
therefore cannot be returned.
Signature: Date:
Page
$19,843.49
$1,289.83
$198.43
$297.65
$21,629.40
Version 8.5.5 Prepared By: WINDOWS, DOORS, & MORE, INC.
Innovation Collection
Hybrid: This unique product incorporates key features
from our aluminum clad, vinyl clad and primed
i exteriors- Combine a primed frame with an aluminum
clad or vinyl clad sash for a low -maintenance, durable
window with historical charm.
v
Traditions Collection
Primed: Built using traditional trim/casing dimensions
I:
and with widely accepted historical design features,
L
's primed windows are the conventional choice
kets requiring painted wood exteriors.
Luxury Collection
Natural Wood: Products with all wood exterior are a
timeless design ready for your finish and sealer. Our
three all -wood exteriors showcase the distinctive
l'
warmth and beauty of wood capable of blending in
F\with natural siding materials.
Lill
CLICK: lincolrwi ndowscom
A.I.A. SPECIFICATION FOR
WOOD DOUBLE HUNG WINDOW
LINCOLN WINDOWS
SECTION 08550
WOOD WINDOWS & CLAD WOOD WINDOWS
PART 1 • GENERAL
1.01 SECTION INCLUDES
A.Wood double hung windows with accessories and
components as indicated on window schedule.
1.02 REFERENCED STANDARDS
A.ASTM C1036 -Flat Glass
B.ASTM E283 -Rate of Air Leakage Through Exterior
Windows, Curtain Walls and Doors.
C.ASTM E330 -Structural Performance of Exterior
Windows, Curtain Walls and Doors by Uniform Static
Air Pressure Performance.
D.ASTM E547 -Water Penetration of Exterior Windows,
Curtain Walls and Doors by Uniform Static Air
Pressure Difference.
E.ASTM E2190-08 -Specification for Sealed Insulated
Glass Units.
F.Federal Specifications-FL L-S-125B -Screening,
Insect Non-Metallic.-FS DD-G-451 D -Glass, Float or
Plate, Sheet.
G.AAMA/WDMA/CSA 101/I.S.2/A440-11 Standard and
Specification for Windows, Doors and Skylights.
H.ATSM E1886 -Standard Test Method for
Performance of Exterior Windows, Curtain Walls,
Doors, and Impact Protective Systems Impacted by
Missile(s) and Exposed to Cyclic Pressure
Differentials
I.ASTM E1996 Standard Specification for
Performance of Exterior Windows, Curtain Walls,
Doors, and Impact Protective Systems Impacted by
Windbome Debris in Hurricanes
1.03 QUALITY ASSURANCE
A. Sealed Durability of Insulating Glass Test -ASTM
E2190-08.
B.Argon Gas Concentration of Insulating Glass Units
Test-ASTM E2649-09.
C.Harmonized Insulating Glass Testing Standards as
designated by IGCC and IGMA.
D.NFRC Certification Program for Energy Ratings of
Fenestration Products.
E.AAMA Certification Program. AAMA Gold Label.
1.04 SYSTEM DESCRIPTION
A.Design and Performance Requirements:
1.Air, water, structural performance and forced
entry resistance testing shall be at levels which
meet the specifications as outlined in
AAMA/WDMA/CSA 101/I.S.2/A440-11.
2.Impact resistance performance rating shall be
Missile Level D, Windzone 3 per ASTM E 1886
and ASTM E 1996.
3.All glass shall be select quality complying with
FS DD-G-451 D.
4.Insulating glass shall be manufactured and
tested to comply with IGCC and ASTM E2190-
08.
B.Energy Requirements:
1. All units tested are single lite residential as
listed on the NFRC label adhered to the glass.
Values are certified per NFRC Certification
Program.
C.Emergency Escape & Rescue
1.Larger width & height units with standard
hardware, as designated, shall comply with the
International Residential Code (minimum clear
opening of 5.7 sq.ft. or 5 sq. ft. for grade floor).
Note: Up to date performance data can be found in
the technical data section on our website at
http://www.lincolnwindows.com
1.05 SUBMITTALS
A.Submit the following in accordance with Section
01330.
B.Shop drawings showing rough openings, unit
dimensions and fenestration of specialty units as
required.
C.Insulated Glass Warranty: Lincoln Wood Products,
Inc. Lifetime Limited Warranty.
1.06 DELIVERY AND STORAGE
A.Deliver products in manufacturer's original containers,
dry, undamaged, seals and labels intact.
B.Store and protect products from job site damage.
Uninstalled products must be protected from
exposure to the weather.
1.07 INSULATED GLASS WARRANTY
A.Lincoln Wood Products, Inc. provides a ten (10) year
limited warranty on general product found to be
defective by virtue of materials or workmanship.
Glass is covered for seal failure causing impaired
visibility due to moisture, film or dust between the
glass panes for twenty (20) years on insulated glass
and ten (10) years on impact-resistant or laminated
glass. For complete details, terms, conditions,
limitations and exclusions, reference the most current
warranty, available at www.lincolnwindows.com.
PARt 2 • PRODUCTS
2.01 MANUFACTURER
Refer to drawings for window schedule indicating sizes and
configuration of units and type of components, colors,
glazing and additional data.
A.Wood double hung windows as specified in this
section and as manufactured by Lincoln Wood
Products, Inc., Merrill, Wisconsin.
2.02 MATERIALS AND FINISHES
Revised 3/20115
A.I.A. SPECIFICATION FOR
WOOD DOUBLE HUNG WINDOW
LINCOLN WINDOWS
SECTION 08550
WOOD WINDOWS & CLAD WOOD WINDOWS
A.WOOD: Kiln-dried selected soft woods and or
engineered wood products, treated with water
repellent preservative in accordance with WDMA 1.5.4
-2000 and applicable Commercial Standards. Frame
depth shall be 4-9/16", with jamb extensions available
up to 1 O". Head and side jambs shall be 11 /16" thick,
with the frame sill 1-3/16" thick. Sash thickness shall
be 1-7/16". Brickmould shall be 2" x 1-3/16",
nosing shall be 1-9/16" x 1-1/16".
B.GLASS: 11/16" IG. 11/16" Laminated insulated impact
resistant IG. Low "E" with Argon. Tempered. Tint:
Bronze, Grey, Obscure, Clear. Warm edge tin plated
spacer or foam spacer used. Steel spacer used on
impact resistant IG. **High altitude IG and IG units
with glass less than 12" width or height have open
breather tube and will not contain argon gas**
C.WEATHERSTRIPPING: Sash are weather-stripped at
the top rail, bottom rail and check rail with a foam
bulb. Head parting stop has a flexible bulb. Soft pile
weather-strip is used in the jamb-liners on the exterior
and sides of the sash.
D.SCREEN:Factory-finished aluminum frame,
.011x18x16 charcoal fiberglass cloth.
E.STANDARD WOOD GRILLES: 5/8", 7/8", 1" Profiled
select wood for attachment to interior of sash and
designed for removal for glass cleaning.
F.FULL SURROUND GRILLES: 5/8", 7/8", 1", 1-7/8"
Profiled select wood for attachment to interior of sash
and designed for removal for glass cleaning
G.INTERNAL MUNTINS: Profiled 11/16", 1" aluminum
grilles permanently sealed between two panes of
insulating glass. Note: Not available on StormPoint
products.
H.TRUE DIVIDED LITES: 7/8" and 1-1/4" wide pine
muntin bars to the exterior with applied pine stops on
the interior. Note: Not available on StormPoint
products.
I.SIMULATED DIVIDED LITES: SDL glass is 11/16"
insulated. Available in 2", 1-1/8" and 7/8" bar widths.
Lite division is accomplished with the application of
interlocking primed aluminum grids on the exterior and
interlocking wood grids on the interior, both secured to
the glass lite with an adhesive glazing tape. Note:
Internal muntins between the glass not available
on StormPoint products.
J.INTERIOR EXTENSION JAMBS: Kiln-dried selected
softwood, for transparent interior finish.
2.03 HARDWARE
A.JAMBLINERS: Extruded vinyl with a spring loaded
mechanical balancing system.
B.LOCK: Manufacturers' standard cam locks. Provide
two locks on units 32" and wider.
C.TILT LATCH: A spring loaded tilt latch is used to
engage and release the sash from the jamb liner,
allowing the sash to be tilted in and removed for
cleaning.
2.04 FABRICATION
A.Fabricate frame, mullions and sash members for
hairline fit, water and airtight.
B.Set insulating glass in silicone bedding
compound, interior glazed with wood stops.
C. Provide insect screens of roll formed frames with
mesh set into frame and secured.
PART 3 -EXECUTION
3.01 INSPECTION
A.Verify rough openings are correctly sized and located.
B.Beginning of installation means acceptance of
existing conditions.
3.02 PREPARATION
A.Prepare opening to permit correct installation of
window unit and air and vapor barrier seal.
3.03 INSTALLATION
A.Install windows in accordance with manufacturer's
instructions.
B.Align windows plumb and level, free of warp or twist.
Maintain dimensional tolerances, aligning with
adjacent work. Secure assembly to frame openings
without distortion or stress.
C.Ensure air and vapor barrier is sealed to window
frame. Coordinate placement of insulation in shim
spaces around unit perimeter.
D.Install sealant and related backing materials at
exterior and interior of installed assembly.
E.Close and latch operating sash.
3.04 CLEANING
A.Clean exterior and interior surfaces of window frames
and glass after installation. Do not damage interior or
exterior finishes.
B.Remove labels and visible markings. Comply with
manufacturer's recommendations for cleaning glass.
C.Remove and replace glass that is broken, chipped,
cracked, abraded or damaged at no expense to
owner.
END OF SECTION
Revised 3120/15
CREDIT CARD PAYMENTS
A Portal Administration Fee will apply
5EE REVERSE SIDE FOR IMPORTANT INFORMATION REAL ESTATE PROPERTY eJ [II] IE0 l(i 1-866-257-2055or pay onllne at
Pulaski Coun
Debra Buckner; Treasurer t.y Tax Statement 2015
www. pulaskicountytreasu rer. net or by mobile at www.pctax.mobi
201 S. Broadway, Suite 150
UtUe Rock. AR 72201
Phnne: (501) 340-6040
Email: treasurer@pulaskicountytreasure
*005R1*50*1*0010145*****SCH 5-DIGIT 72201KENT TERRY/BRENDA
501 E 7TH STLITTLE ROCK AR 72202-2514
11••••l•l••l•11l•ll1lll1 1•l'•l'l•11•111•l1ll 1l11l'111•1lll1lll1 I ,
r.net co. BILL NUMBER CODE
60 264104-15
PARCEL NUIIBER ASSESSED VALUE
34L0220001800 26,330
MILLAGE RATE TAX% TAXABLE VAWE
.0700 1.40% 19,914
11111111111111111
Property Address:
Legal Description:
501 E 7TH ST UTILE ROCK, AR 72202
LOT 1 BLOCK 4 JOHNSON'S ADON JOHNSON N10
O' OF LOT 1 (85X100) 4
2015 GENERAL TAXES AND COST
0-1-5 TAX-CREDIT ---
1,393.99
---- --- 50.00
TOTAL TAXES DUE
IF YOU CHOOSE TO PAY BY INSTALLMENTS, PLEASE REMIT AS FOLLOWS:
$261.00 PAYABLE
on or before 4/18/16 $261.00 PAYABLE
4/19 -7/18/16 $ 521.99
2015 TAX DOLLAR BREAKDOWN (WHOLE DOLLARS) -TAXES CAN NOT BE PAID SEPARATELY
TAXING UNIT
COUNTY GENERAL FUND
CHILDREN$ HOSPITAL
COUNTY ROAD FUND/SPL
LITTLE ROCK SCHOOL D
MILLS
.00500
.00060
.00145
.04640
AMOUNT
$99
$11
$28
$924
CITY
LITTLE ROCK GENERAL
LITTLE ROCK BOND AND
LITTLE ROCK LIBRARY
LITTLE ROCK POLICE P
LITTLE ROCK FIREMENS
LITTLE ROCK ROAD FUN
LITTLE ROCK CAPITAL
MILLS
.00500
.00300
.00330
.00100
.00100
.00145
.00180 • l!I THIS IS THE ONLY BILL YOU WILL RECEIVE· SEE REVERSE SIDE FOR DETAILS
RECEIPTS CAN BE VIEWED AND PRINTED AT WWW.PULASKICOUNTYTREASURER.NET
DELINQUENT PENALTIES (AT LEAST 10%} AND COSTS CAN BE AVOIDED BY PAYMENT IN FULL BY OCTOBER 17TH.
$1,043.99
PAYABLE
7/19 -10/17/16
AMOUNT
$99
$59 $65
$19
$19
$28
$35
" First Nat1bnal Title Company
415 N. McKinley Street
Suite 1200
Little Rock, AR 72205
File No. JSC-150578-01
lllltllllllllUilllfllllUJHl HHJI 2015069269
PRESENTED: 11--03-2015 03:20:29 PM RECORDED: 11-03-2015 03:28:42 PM
In Official Records of Larry Crane Circuit/County Clerk
PULASKI CO, AR FEE $25.00
WARRANTY DEED
UNMARRIED PERSON
KNOW ALL MEN BY THESE PRESENTS:
THAT Tonya R. Robinson, an unmarried person, hereinafter called "GRANTOR," for and in
consideration of the sum of One Dollar ($1.00) and otber good and valuable consideration in hand paid by
Terry Kent and Brenda Kent, husband and wife, hereinafter called "GRANTEES", the receipt of
which is hereby acknowledged, does hereby grant, bargain, sell and convey unto the said "GRANTEES,"
and unto their heirs and assigns forever, the following lands lying in the County of Pulaski, State of
Arkansas, to wit:
Lot 1, Block 4, Johnson's Addition to the City of Little Rock, Pulaski County,
Arkansas, being 85 feet front on East Seventh Street by 150 feet in depth, and more
particularly described as: Beginning where the line of said Lot on East Seventh
Street meets the Quapaw line and run South on the Quapaw line 150 feet; thence
East along the North line of the 50 foot Lot known as the Olivia C. Denison Lot, and
35 feet along the North line of the Lot known as the Wildberger Lot; thence North
to East Seventh Street; thence West along the line of Seventh Street to the point of
beginning. EXCEPT the South 44 feet of the above described land.
TO HA VE AND TO HOLD the same unto the said GRANTEES and unto their heirs and assigns
forever, with all appurtenances thereunto belonging.
AND GRANTOR hereby covenants with said GRANTEES that she will forever warrant and
defend the title to said lands against all lawful claims whatever, subject to existing easements, building
lines, restrictions and assessments of record, if any. No warra ty or representation is made as to any
mineral interest on the aforementioned property.
File No. JSC-150578-01
Prepared under the supervision of
Pender Law Firm
Attorney at Law
415 N. McKinley Street, Suite 1200
Little Rock, AR 72205
Page 1 of2
WITNESS my hand and sea on this 29th day of October, 2015.
Tanya R. Robinson
I certify under penalty of false swearing that the legally correct
amount of documentary stamps have been placed on this
instrument. Exempt or no consideration paid if none shown.
GRANTEES: Terry Kent and Brenda Kent
ADDRESS: 501 East 7th Street
Little Rock, AR 72202
STATE OF ARKANSAS
COUNTY OF PULASKI
ACKNOWLEDGEMENT
BE IT REMEMBERED that on this day came before the undersigned, a Notary Public within and
for the County aforesaid, duly commissioned and acting, Tonya R. Robinson, to me well known as the
Grantor in the foregoing Deed, and stated that she had executed the same for the consideration and
purposes therein mentioned and set forth.
WITNESS my hand and seal as such Notary Public this 29th day of October, 2015.
File No. JSC·l50578-0l
JANIC ·ci.'.AYTON
PULASKI COUNTY
NOTARY PUBLIC. ARKANSAS
c-1rea s-14-2021 My corr.mission....... 382677 commission# 12
Jan
N --My commission expires: June 14, 2021
JANICE. CLAYTON PULASKI COUNTY
MN OTA RY PUBLIC. ARKANSAS Y Comm1ss1011 Ul>lres 6-14·2021 Comm1ss1011 # 12382677
Page2 of2