Loading...
HomeMy WebLinkAboutZ-4743-D Map 6Phone PI Power 24" CIPR \SANITARY SEWER a\ /moo Light Inlet #5 Rebar Dumpster Front to be Screened P P S With Metal Doors, 6' High i 0 \ / Light Pale cal ? iox /sem„ TO RELOCATED Sewer Ma of = S' L 2�, Q 2GV metro Bus Bench Concrete Area SIDEWALK a T B.L.A. / 6 24" CIPR SANITARY SEWER 6"CMP 4 6" CMP 18" RCP 18" RCPPP��CMP \ P12" RCP ,--Found / 4 I / #5 ar Sewer Manhole Light Pole -,\ /--Power Pole w/Underground / EXISTING UTILITY EASEMENT (TBR) v Concrete Area 13 Light Pol -' ! Q 0 No Proposed Fencing Along (`Q EXISTING UTILITY Thls Property Line EASEMENT (TBR) Q j Drain Mannol�� / Rim = 166.18 \ Invert= 157.35 0 Com' �� e Concrete Ar a 13� 08 I. / Concrete Area e ewer Manhole / Concrete Area 0 03 Concrete Area I Iell,D1 / 6k 1,880ILA 03 / O6 �qF4� 05 / .10 12 01 03 / Approxima— 45' SET -BACK LINE Road Centerline � Water Line Concrete 4-9,/ I M Wight Pol oncretBAPro n pPS all Y Water Mete FXISTIWG pRIVf 6,-9'pFIS11 Drain Inlet - r Power Pol Fire Hydran NOTE. EXISTING CONCRETE CURB,GUTTER V _ AND SIDEWALK TO BE MOVED BACK Strom Drain APPROXIMATELY 4' TO ALLOW FOR A 256'-3, Curb Inlet WIDENED RIGHT TURN LANE THATWILL BE APPROXIMATELY 250' LONG n / l�Water Meter N=L Rad n Power Pole SIGN INFO SIGN INFO - SIGN INFO SIGN INFO - \ � Light Pole SITE LEGEND MARK OTY. SUPPLIER/ INSTALLER DESCRIPTION 01 4 FEC GILBARCO MPD AS PER EXXON I.D. SPECIFICATIONS. 02 2 FEC GILBARCO 3 + 1 MPD AS PER EXXON I.D. SPECIFICATIONS. 03 6 FEC 4'x 12' RAISED CONCRETE FILLED PUMP ISLAND. PAINT AS PER EXXON SPECIFICATIONS. 04 1 FEC 48" X 84' EXXON CANOPY WITH ILLUMINATED FASCIA AS PER EXXON SPECIFICATIONS. ONE COLUMN PER MPD. 05 1 FEC 15,000 GALLON 3 COMPARTMENT U.G. FUEL STORAGE TANK ( UNL ) 06 1 FEC 12,000 GALLON 2 COMPARTMENT U.G. FUEL STORAGE TANK ( PREM & DSL) —0 ---4— GC 12'X 23'X & HIGH CMU DUMPSTER ENCLOSURE WITH METAL GATE SCREENING. ( FOR TWO & X 6'X 6' DUMPSTER BINS ) 08 1 GC ADA RAMP 09 1 EXISTING EXISTING EXXON TWO POST I.D. & PRICE SIGN WITH READER BOARD(S); VERIFY SPECS WITH OWNER. PAINT POSTAS PER EXXON SPECIFICATIONS. 184 SQUARE FEET AREA OF SIGNAGE; EACH SIDE. TOTAL HEIGHT ABOVE GROUND: 26'. 0 1 0 / GC / SC EXXON SINGLE POST I.D. & PRICE SIGN WITH READER BOARD(S); VERIFY SPECS WITH OWNER, PAINT POST AS PER EXXON SPECIFICATIONS, 199 SQUARE AREA OF SIGNAGE; EACH SIDE. TOTAL HEIGHT ABOVE GROUND: 34'-3". 11 1 0 / GC "DOUBLEBEE'S" BUILDING I.D. SIGN ABOVE ENTRANCE DOOR; 60 SQUARE FEET 12 2 CC "EXXON" CANOPY LOGO SIGN; 30" HIGH X 8' LONG, 20 SQ. FT, EACH SIGN. (15% OF TOTAL CANOPY PERIMETER FASCIA). 13 1 0 /GC PRE -ORDER MENU VIEWING BOARD; PROVIDE SCREENING AS SHOWN 14 1 0 /GC MENU BOARD WITH SPEAKER; PROVIDE SCREENING AS SHOWN GENERAL NOTES: A. ALL SITE LIGHTING TO BE LOW-LEVEL AND DIRECTIONAL, AIMED DOWNWARD AND INTO THE SITE, B. MAXIMUM BUILDING HEIGHT TO BE 22-1-1/2". C. NO FENCING IS PROPOSED. D. FRONT OF DUMPSTER AREA TO BE SCREENED WITH METAL DOORS. E. DRIVE-THRU MENU BOARD(S) TO BE SCREENED AS PER SECTION 36-2298(1) (a) F. AN 8' VARIANCE IS TO BE REQUESTED FROM THE REQUIRED 1T BUFFER ON RIVERFRONT DRIVE ( T PERIMETER PLANTING STRIP IS SHOWN). G. RELOCATED STORMWATER EASEMENTS SKETCH GRADING AND DRAINAGE PLAN, AND 100 YEAR OVERFLOW PATH ARE ATTACHED AS PRELIMINARY STORMWATER PLAN SHEET C1.0. SITE LEGEND SCHEDULE ABBREVIATIONS O OWNER CC CANOPY CONTRACTOR FEC FUEL EQUIPMENT CONTRACTOR GC GENERAL CONTRACTOR SC SIGN CONTRACTOR LV LOCALVENDOR VWO VERIFY WITH OWNER VEHICULAR USE AREA C -STORE PARKING REQUIREMENTS: 33,014SO. FT. 4 + 1 PER 300 S F OF BLDG AREA X 8% = 2,641SOFT. REQUIRED 3726 S.F. BLDG / 300=13 PLUS 4 = FOR INTERIOR LANDSCAPE AREA 17 PARKING SPACES REQUIRED 2,890 SQ. FT. SHOWN 18 PARKING SPACES SHOWN LANDSCAPE ABBREVIATIONS BEA BUILDING LANDSCAPE AREA ILA INTERIOR LANDSCAPE AREA PPS PERIMETER PLANTING STRIP (BUFFER). LANDSCAPE NOTES: A. ALL LANDSCAPE AREAS TO COMPLY WITH TREE AND SHRUB REQUIREMENTS AS PER ORDINANCE. B. ALL LANDSCAPE AREAS TO HAVE IRRIGATION SYSTEM. NOT FOR CONSTRUCTION AT THE TIME OF THIS DRAWING, THE DESIGNER HAD NOT RECEIVED A CURRENT BOUNDARY SURVEY OF THIS PROPERTY. \ THEREFORE THIS DRAWING IS FOR PRELIMINARY SITE LAYOUT PURPOSES ONLY AND IS NOT FOR CONSTRUCTION. Light Pole AS ower Pole w/Underground Concrete Area 1,0101LA —Light Pole _ Light Pol / \ v 61-91,pPS \ \ \ EXISTING \ �� Landscape Area 3� DRIVE v _ " \ \ SiQSwalk. \ Strom Drain Curb Inlet 1 SITE LAYOUT Sale: 1" = 20'-0" Pole V/ et, Pole iA / \ MAR U 12011 CLEMENTS & ASSOCIATES ARCHITECTURE, INC. 507 MAIN STREET N LITTLE ROCK, AR. 72114 501.375.3380 501.375.8231 fax PROJECT MGR. DEAN TAYLOR 501.837.1099 101, General Notes 1. THIS DOCUMENT MAY NOT BE COPIED OR USED FOR CONSTRUCTION WITHOUT THE EXPRESSED WRITTEN CONSENT OF CLEMENTS AND ASSOCIATES, INC. Remodel Nates A. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS, AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF THE WORK, THE SUBMISSION OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE LATER CLAIMS FOR LABOR EQUIPMENT OR MATERIALS REQUIRED OR FOR ANY DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORSEEN HAD AN EXAMINATION BEEN MADE WILL NOT BE ALLOWED B. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS AND SPECIFICATIONS INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, CIVIL, STRUCTURAL MECHANICAL, PLUMBING, LIGHTING ELECTRICAL FUEL CANOPY AND FUEL SYSTEM INSTALLATION PRIOR TO SUBMITTING A BID. REPORT ANY DISCREPANCIES TO DESIGNER PRIOR TO BID C. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER, OWNER OR TENANT OF ANY DISCREPANCIES ENCOUNTERED ON THE PLANS OR IN EXISTING SITE CONDITIONS PRIOR TO SUBMISION OF BID. D. CONTRACTOR. DURING PRE-BID VISIT, SHALL TAKE NOTICE OF ANY VISUALLY APPARENT CODE VIOLATIONS AND ALLOW IN HIS/HER BiD FOR CORRECTION OF SUCH VIOLATIONS. E. CONTRACTORS ARE CAUTIONED TO COORDINATE ITEMS IN THEIR SCOPE OF WORK WITH OTHER TRADES. F. PRIOR TO BIDDING, CONTRACTOR TO VISIT WITH OWNER OR OWNER'S REPRESENTATIVE AND DETERMINE ITEMS WHICH WILL BE FURNISHED AND INSTALLED By OWNER. (EXAMPLE: ALL FOODSERVICE & REFRIGERATING EQUIPMENT WILL BE FURNISHED AND INSTALLED BY OWNER, LESS ELECTRICAL AND PLUMBING). CONTRACTOR TO MAKE FINAL CONNECTIONS INCLUDING ELECTRICAL AND PLUMBING, FOR A COMPLETE AND WORKABLE SYSTEM, OR AS DETERMINED BY OWNER OR OWNER'S REPRESENTATIVE. G. THESE NOTES APPLY TO ALL SHEETS. H. TBR (TO BE REMOVED) No. I Revision/Issue I Date Project Name and Address DOUBLEBEE'S EXXON 2402 CANTRELL ROAD LITTLE ROCK, AR. File Sheet DBCR17 PRELIMINARY SITE PLAN Date 03-01-2017 A 1.0 Scale AS SHOWN