HomeMy WebLinkAboutZ-4743-D Map 6Phone PI
Power
24" CIPR
\SANITARY SEWER
a\
/moo
Light
Inlet
#5 Rebar
Dumpster Front to be Screened
P P S With Metal Doors, 6' High
i
0 \ / Light Pale
cal ?
iox
/sem„
TO
RELOCATED
Sewer Ma of = S'
L 2�,
Q
2GV metro Bus
Bench
Concrete Area
SIDEWALK a
T B.L.A. /
6
24" CIPR
SANITARY SEWER
6"CMP 4
6" CMP
18" RCP
18" RCPPP��CMP
\ P12" RCP
,--Found
/ 4 I
/ #5 ar
Sewer Manhole
Light Pole
-,\ /--Power Pole w/Underground
/ EXISTING UTILITY
EASEMENT (TBR) v
Concrete Area 13
Light Pol -' ! Q
0 No Proposed Fencing Along
(`Q EXISTING UTILITY
Thls Property Line
EASEMENT (TBR)
Q
j
Drain Mannol��
/
Rim = 166.18 \
Invert= 157.35 0
Com' ��
e
Concrete Ar a
13� 08
I.
/
Concrete Area
e
ewer Manhole
/ Concrete Area
0 03
Concrete Area I Iell,D1 / 6k
1,880ILA 03 / O6 �qF4� 05
/
.10 12
01 03 /
Approxima— 45' SET -BACK LINE
Road Centerline �
Water Line Concrete
4-9,/ I M
Wight Pol oncretBAPro n pPS all
Y Water Mete FXISTIWG pRIVf
6,-9'pFIS11
Drain Inlet -
r
Power Pol
Fire Hydran
NOTE. EXISTING CONCRETE CURB,GUTTER V _
AND SIDEWALK TO BE MOVED BACK Strom Drain
APPROXIMATELY 4' TO ALLOW FOR A 256'-3, Curb Inlet
WIDENED RIGHT TURN LANE THATWILL BE
APPROXIMATELY 250' LONG n /
l�Water Meter
N=L Rad n
Power Pole
SIGN INFO
SIGN INFO -
SIGN INFO
SIGN INFO -
\ � Light Pole
SITE LEGEND
MARK
OTY.
SUPPLIER/
INSTALLER
DESCRIPTION
01
4
FEC
GILBARCO MPD AS PER EXXON I.D. SPECIFICATIONS.
02
2
FEC
GILBARCO 3 + 1 MPD AS PER EXXON I.D. SPECIFICATIONS.
03
6
FEC
4'x 12' RAISED CONCRETE FILLED PUMP ISLAND. PAINT AS PER EXXON SPECIFICATIONS.
04
1
FEC
48" X 84' EXXON CANOPY WITH ILLUMINATED FASCIA AS PER EXXON SPECIFICATIONS. ONE COLUMN PER MPD.
05
1
FEC
15,000 GALLON 3 COMPARTMENT U.G. FUEL STORAGE TANK ( UNL )
06
1
FEC
12,000 GALLON 2 COMPARTMENT U.G. FUEL STORAGE TANK ( PREM & DSL)
—0
---4—
GC
12'X 23'X & HIGH CMU DUMPSTER ENCLOSURE WITH METAL GATE SCREENING. ( FOR TWO & X 6'X 6' DUMPSTER BINS )
08
1
GC
ADA RAMP
09
1
EXISTING
EXISTING EXXON TWO POST I.D. & PRICE SIGN WITH READER BOARD(S); VERIFY SPECS WITH OWNER. PAINT POSTAS PER
EXXON SPECIFICATIONS. 184 SQUARE FEET AREA OF SIGNAGE; EACH SIDE. TOTAL HEIGHT ABOVE GROUND: 26'.
0
1
0 / GC / SC
EXXON SINGLE POST I.D. & PRICE SIGN WITH READER BOARD(S); VERIFY SPECS WITH OWNER, PAINT POST AS PER EXXON
SPECIFICATIONS, 199 SQUARE AREA OF SIGNAGE; EACH SIDE. TOTAL HEIGHT ABOVE GROUND: 34'-3".
11
1
0 / GC
"DOUBLEBEE'S" BUILDING I.D. SIGN ABOVE ENTRANCE DOOR; 60 SQUARE FEET
12
2
CC
"EXXON" CANOPY LOGO SIGN; 30" HIGH X 8' LONG, 20 SQ. FT, EACH SIGN. (15% OF TOTAL CANOPY PERIMETER FASCIA).
13
1
0 /GC
PRE -ORDER MENU VIEWING BOARD; PROVIDE SCREENING AS SHOWN
14
1
0 /GC
MENU BOARD WITH SPEAKER; PROVIDE SCREENING AS SHOWN
GENERAL NOTES:
A. ALL SITE LIGHTING TO BE LOW-LEVEL AND DIRECTIONAL, AIMED
DOWNWARD AND INTO THE SITE,
B. MAXIMUM BUILDING HEIGHT TO BE 22-1-1/2".
C. NO FENCING IS PROPOSED.
D. FRONT OF DUMPSTER AREA TO BE SCREENED WITH METAL DOORS.
E. DRIVE-THRU MENU BOARD(S) TO BE SCREENED AS PER SECTION
36-2298(1) (a)
F. AN 8' VARIANCE IS TO BE REQUESTED FROM THE REQUIRED 1T BUFFER
ON RIVERFRONT DRIVE ( T PERIMETER PLANTING STRIP IS SHOWN).
G. RELOCATED STORMWATER EASEMENTS SKETCH GRADING AND
DRAINAGE PLAN, AND 100 YEAR OVERFLOW PATH ARE ATTACHED AS
PRELIMINARY STORMWATER PLAN SHEET C1.0.
SITE
LEGEND SCHEDULE ABBREVIATIONS
O
OWNER
CC
CANOPY CONTRACTOR
FEC
FUEL EQUIPMENT CONTRACTOR
GC
GENERAL CONTRACTOR
SC
SIGN CONTRACTOR
LV
LOCALVENDOR
VWO
VERIFY WITH OWNER
VEHICULAR USE AREA
C -STORE PARKING REQUIREMENTS:
33,014SO. FT.
4 + 1 PER 300 S F OF BLDG AREA
X 8% = 2,641SOFT. REQUIRED
3726 S.F. BLDG / 300=13 PLUS 4 =
FOR INTERIOR LANDSCAPE AREA
17 PARKING SPACES REQUIRED
2,890 SQ. FT. SHOWN
18 PARKING SPACES SHOWN
LANDSCAPE ABBREVIATIONS
BEA BUILDING LANDSCAPE AREA
ILA INTERIOR LANDSCAPE AREA
PPS PERIMETER PLANTING STRIP (BUFFER).
LANDSCAPE NOTES:
A. ALL LANDSCAPE AREAS TO COMPLY WITH TREE AND SHRUB
REQUIREMENTS AS PER ORDINANCE.
B. ALL LANDSCAPE AREAS TO HAVE IRRIGATION SYSTEM.
NOT FOR CONSTRUCTION
AT THE TIME OF THIS DRAWING, THE DESIGNER HAD NOT
RECEIVED A CURRENT BOUNDARY SURVEY OF THIS PROPERTY.
\ THEREFORE THIS DRAWING IS FOR PRELIMINARY SITE LAYOUT
PURPOSES ONLY AND IS NOT FOR CONSTRUCTION.
Light Pole
AS ower Pole w/Underground
Concrete Area
1,0101LA
—Light Pole _ Light Pol / \
v 61-91,pPS
\ \ \
EXISTING \
�� Landscape Area 3�
DRIVE v _ "
\
\
SiQSwalk. \
Strom Drain
Curb Inlet
1 SITE LAYOUT
Sale: 1" = 20'-0"
Pole
V/
et, Pole iA
/
\
MAR U 12011
CLEMENTS & ASSOCIATES
ARCHITECTURE, INC.
507 MAIN STREET
N LITTLE ROCK, AR. 72114
501.375.3380 501.375.8231 fax
PROJECT MGR.
DEAN TAYLOR
501.837.1099
101,
General Notes
1. THIS DOCUMENT MAY NOT BE COPIED OR USED
FOR CONSTRUCTION WITHOUT THE EXPRESSED
WRITTEN CONSENT OF CLEMENTS AND
ASSOCIATES, INC.
Remodel Nates
A. BIDDERS ARE TO VISIT THE SITE AND
FAMILIARIZE THEMSELVES WITH EXISTING
CONDITIONS, AND SATISFY THEMSELVES
AS TO THE NATURE AND SCOPE OF THE
WORK, THE SUBMISSION OF A BID WILL BE
EVIDENCE THAT SUCH AN EXAMINATION
HAS BEEN MADE LATER CLAIMS FOR
LABOR EQUIPMENT OR MATERIALS
REQUIRED OR FOR ANY DIFFICULTIES
ENCOUNTERED WHICH COULD HAVE BEEN
FORSEEN HAD AN EXAMINATION BEEN
MADE WILL NOT BE ALLOWED
B. IT IS THE CONTRACTORS RESPONSIBILITY
TO REVIEW ALL DRAWINGS AND
SPECIFICATIONS INCLUDING BUT NOT
LIMITED TO ARCHITECTURAL, CIVIL,
STRUCTURAL MECHANICAL, PLUMBING,
LIGHTING ELECTRICAL FUEL CANOPY AND
FUEL SYSTEM INSTALLATION PRIOR TO
SUBMITTING A BID. REPORT ANY
DISCREPANCIES TO DESIGNER PRIOR TO
BID
C. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO NOTIFY THE DESIGNER,
OWNER OR TENANT OF ANY
DISCREPANCIES ENCOUNTERED ON THE
PLANS OR IN EXISTING SITE CONDITIONS
PRIOR TO SUBMISION OF BID.
D. CONTRACTOR. DURING PRE-BID VISIT,
SHALL TAKE NOTICE OF ANY VISUALLY
APPARENT CODE VIOLATIONS AND ALLOW
IN HIS/HER BiD FOR CORRECTION OF SUCH
VIOLATIONS.
E. CONTRACTORS ARE CAUTIONED TO
COORDINATE ITEMS IN THEIR SCOPE OF
WORK WITH OTHER TRADES.
F. PRIOR TO BIDDING, CONTRACTOR TO VISIT
WITH OWNER OR OWNER'S
REPRESENTATIVE AND DETERMINE ITEMS
WHICH WILL BE FURNISHED AND
INSTALLED By OWNER. (EXAMPLE: ALL
FOODSERVICE & REFRIGERATING
EQUIPMENT WILL BE FURNISHED AND
INSTALLED BY OWNER, LESS ELECTRICAL
AND PLUMBING). CONTRACTOR TO MAKE
FINAL CONNECTIONS INCLUDING
ELECTRICAL AND PLUMBING, FOR A
COMPLETE AND WORKABLE SYSTEM, OR
AS DETERMINED BY OWNER OR OWNER'S
REPRESENTATIVE.
G. THESE NOTES APPLY TO ALL SHEETS.
H. TBR (TO BE REMOVED)
No. I Revision/Issue I Date
Project Name and Address
DOUBLEBEE'S EXXON
2402 CANTRELL ROAD
LITTLE ROCK, AR.
File
Sheet
DBCR17
PRELIMINARY
SITE PLAN
Date
03-01-2017
A 1.0
Scale
AS SHOWN