Loading...
HomeMy WebLinkAboutZ-4743-D Map 4O 1/ v ro ^O 6g • PROPOSED STORMWATER \ \ INLET TO DRAIN TO DITCH — — + / EXISTING BOX CULVERT UVDER EXISTING UTILITY RAILROAD (NOT SHOWN) EXISTING UTILITY EASEMENT } v EASEMENT TO REMAIN ��� PROPOSED UTILITY EASEMENT 187 EXISTING MINOR CONTOUR 165 EXISTING MAJOR CONTOUR LO / �• \ ' \\ ' —> PRIMARY FLOW DIRECTION ALONG SWALE EXISTING UTILITY 9 / *PROPOSED 10' EASEMENT TO BE RELOCATED E— STORMWATER RUNOFF FLOW DIRECTION p UTILITY EASEMENT WWW PROPOSED STORMWATER INLET TO DRAIN TO DITCH / / • • / / �/ \ \ . GENERAL NOTES: A. ALL SITE LIGHTING TO BE LOW-LEVEL AND DIRECTIONAL, AIMED / DOWNWARD AND INTO THE SITE. B. MAXIMUM BUILDING HEIGHT TO BE 22'-1-1/2'. C. NO FENCING IS PROPOSED. r D. FRONT OF DUMPSTER AREA TO BE SCREENED WITH METAL DOORS. E. DRIVE-THRU MENU BOARD(S) TO BE SCREENED AS PER SECTION , \ 36-2298(1) (a). ,1 fi F. AN 8' VARIANCE IS TO BE REQUESTED FROM THE REQUIRED 17' BUFFER ON RIVERFRONT DRIVE. ( 9' PERIMETER PLANTING STRIP IS SHOWN). G. RELOCATED STORMWATER EASEMENTS, SKETCH GRADING AND DRAINAGE PLAN, AND 100 YEAR OVERFLOW PATH ARE ATTACHED AS / PRELIMINARY STORMWATER PLAN SHEET C1 0 n / CONNECT EXISTING STORMWATER DRAIN INTO PROPOSED CULVERT /\ . CONNECT EXISTING STORMWATER DRAIN INTO PROPOSED BOX CULVERT AND REROUTE TO NORTH / PROPOSED 10' / UTILITY EASEMENT [ EXTENSION / [ORM DRAIN MANHOLE RIM = 166.18 INVERT = 157.35 r� v _v _v STORM DRAIN INLET TO REMAIN J EXISyNG UTILITY / �J EAQEMENTTO REMAIN67 / \ \ PROPOSED STORMWATER INLET TO DRAIN TO DITCH /EXISTING UTILI EASEMENT TO BE ELOCATED \ --- ti I, V_ v_ Y 1 V v i V PROPOSED 10' ' UTILITY EASEMENT ^ jl CONNECT EXISTING STORMWATER DRAIN INTO PROPOS® CULVERT AND REROUTE TO NORTHEAST v NOT FOR CONSTRUCTION EXISTING UTILITY EASEMENT TO REMAIN 67 �� Landscape Area 168 ` \ �6s \ J� \ \ EXISTING UTILITY / EASEMENTTTOOREMAIN \ s \ 2 SITE STORMWATER PLAN Sc�e: I- =29 (r CLEMENTS & ASSOCIATES ARCHITECTURE, INC. 507 MAIN STREET N LITTLE ROCK, AR. 72114 501.375.3380 501.375.8231 fax PROJECT MGR. DEAN TAYLOR 501.837.1099 Sea! General Notes 1. THIS DOCUMENT MAY NOT BE COPIED OR USED FOR CONSTRUCTION WITHOUT THE EXPRESSED WRITTEN CONSENT OF CLEMENTS AND ASSOCIATES, INC. Remodel Notes A. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS, AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF THE WORK. THE SUBMISSION OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED, OR FOR ANY DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORSEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED. B. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL DRAWINGS AND SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, LIGHTING, ELECTRICAL, FUEL CANOPY AND FUEL SYSTEM INSTALLATION PRIOR TO SUBMITTING A BID. REPORT ANY DISCREPANCIES TO DESIGNER PRIOR TO BID. C. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER, OWNER, OR TENANT OF ANY DISCREPANCIES ENCOUNTERED ON THE PLANS OR IN EXISTING SITE CONDITIONS PRIOR TO SUBMISION OF BID. D. CONTRACTOR, DURING PRE-BID VISIT, SHALL TAKE NOTICE OF ANY VISUALLY APPARENT CODE VIOLATIONS AND ALLOW IN HIS/HER BID FOR CORRECTION OF SUCH VIOLATIONS, E. CONTRACTORS ARE CAUTIONED TO COORDINATE ITEMS IN THEIR SCOPE OF WORK WITH OTHER TRADES. F. PRIOR TO BIDDING, CONTRACTOR TO VISIT WITH OWNER OR OWNER'S REPRESENTATIVE AND DETERMINE ITEMS WHICH WILL BE FURNISHED AND INSTALLED BY OWNER. (EXAMPLE: ALL FOODSERVICE 8 REFRIGERATING EQUIPMENT WILL BE FURNISHED AND INSTALLED BY OWNER, LESS ELECTRICAL AND PLUMBING). CONTRACTOR TO MAKE FINAL CONNECTIONS INCLUDING ELECTRICAL AND PLUMBING, FOR A COMPLETE AND WORKABLE SYSTEM, OR AS DETERMINED BY OWNER OR OWNER'S REPRESENTATIVE. G. THESE NOTES APPLY TO ALL SHEETS. H. TBR (TO BE REMOVED) No. I Revision/Issue I Date Project Name and Address DOUBLEBEE'S EXXON 2402 CANTRELL ROAD LITTLE ROCK, AR. File Sheet DBCR17 PRELIMINARY STOMWATER Date 03-01-2017 PLAN C 1 0 Soule AS SHOWN .