Loading...
HomeMy WebLinkAboutZ-4662-A Staff AnalysisDecember 12, 1995 1 FILE NO.: Z -4662-A NAME: BOEN ADDITION, LOT 1 -- ZONING SITE PLAN REVIEW LOCATION: On the north side of Col. Glenn Road, approximately 0.1 mile west of Shackleford Road DEVELOPER: ENGINEER: Pat McGetrick LEONARD BOEN MCGETRICR ENGINEERING 11600 Otter Creek South 11225 Huron Ln., Suite 200 Little Rock, AR 72103 Little Rock, AR 72211 455-0004 223-9900 AREA: 4.81 ACRES NUMBER OF LOTS: 1 FT. NEW STREET: 0 ZONING: I-1 PROPOSED USES: Mini -Warehouse; Office Warehouse; Manager's Office and Residence PLANNING DISTRICT: 11 CENSUS TRACT: 24.05 VARIANCES REQUE$TED: None STATEMENT OF PROPOSAL: Review of a site plan is proposed for development of a 4.81 acre tract to include 18,900 square feet of office warehouse area and 56,725 square feet of mini -storage facilities, including a manager's office and residence. The office warehouse use area is the 285 foot long by 60 foot deep building across the front of the lot, plus a 30 foot wide by 60 foot deep portion of the west front building. The remainder of the west building, plus the south and east boundary building, and five interior buildings, are mini -storage uses. A manager's office and residence are to be provided. Parking for 61 vehicles is provide. Dedication of the required right-of-way and construction of half -street improvements to Col. Glenn Rd. are proposed to be provided. No variances are requested. A. PROPOSAL/REOUBST: Review and approval by the Planning Commission is requested for a site plan. December 12, 1995 SUBDIVISION ITEM NO.: 15 (Continued) FILE NO.: Z -4662-A B. EXISTING, -CONDITIONS: The site is undeveloped and wooded. The site rises in topography from an elevation of 336 feet, MSL (Mean Sea Level) at the southeast corner of the tract, to 360 feet, MSL, at the northwest corner, a 24 foot differential within 650 feet, or a 4% average grade across the site. Grades range, however, up to 9%, with a 6% grade being the median grade on the site. The site is zoned I-1. There is a C-2 site immediately to the west, and is the location of the Sam's Club building. Lot 2 of the development, zoned I-1, lies to the east. The property to the south and north is zoned R-2. C. ENGINEERING/UTILITY COMMENT Public Works comments: Proper grading plans and erosion control plans are required prior to construction. Col. Glenn Rd. is a Principal Arterial. Dedication of right -o -way to 55 feet from centerline must be dedicated, and construction of one-half street improvements, in including a sidewalk, on Col. Glenn Rd. is required. The four-way crossing drive may not be closer to the new curb line on Col. Glenn Rd. than 50 feet. Stormwater detention analysis is required. Open ditches are generally not permitted by the Stormwater Management and Drainage Manual. If ditches are planned, they must be shown on the preliminary plat and must be approved by the City Engineer prior to Planning Commission approval of the plat [Ref. Sec. 311-89(9)]. Show water courses entering the plat area, and the planned exit points for drainage. Little Rock Water Works comments that on-site fire protection will be required. Little Rock Wastewater Utility comments that sewer main extensions, with easements, will be required. Arkansas Power and Light Co. did not provide comments. Arkansas Louisiana Gas Co. approved the submittal, with the stipulation that ARKLA has no objection to the layout, provided that no ARKLA facilities are disturbed. 2 December 12, 1995 HDIVI IO ITEM NO.: 15 (Continued) FILE NO.: Z-46 2-A Southwestern Hell Telephone Co. approved the submittal. The Little Rock Fire Department approved the submittal. D. ISSUES/LEGAL/TECHNICAL/DE I Sec. 36-127 requires that, among other zoning districts, sites in I-1 zoned areas are subject to site plan review by the Planning Commission. Sec. 36-319 requires that the front building setback line on I-1 zoned lots be set at least 70 feet off the right-of-way; that the side yards are to be at least 30 feet in width; and that the rear yard setback be at least 40 feet from the lot line. The site plan shows the front building to be 40 feet. The buildings are well behind this line, but the shown line needs to be corrected. The west side setback is shown to be 29.8 feet; 30 feet is required. The applicant can request, and the Commission can approve, a variance from this requirement in the site plan review approval. The Site Plan Review Specialist notes: The full ordinance requirement for the front landscape buffer is 25 1/2 feet (or, 17 feet minimum with transfer to another area of the site). The site plan appears to meet this requirement. A 6' high opaque screen, either a wood fence with its face directed outward, or dense evergreen plantings, are required along the east property line not screened by the proposed structure. E. ANALYSIS• There are only minimal deficiencies in the submittal, and these can be addressed subsequent to the Commission approval of the site plan. Staff can support the minor west side yard variance (0.2 feet!), if the applicant wishes to add this request to the item. F. STAFF RECOMMENDATIONS: Staff recommends approval of the site plan. 3 December 12, 1995 -SUBDIVISION ITEM N0. 15 (Continued _ FILE N0. Z -4562=A UBDIVISION COMMITTEE �-QdBMENT: (NOVEMBER 22, 1995) Mr. Pat McGetrick, the project engineer, was present. Staff outlined the nature of the project and reviewed with Mr. McGetrick and the Committee members the concerns in the discussion outline. It was noted that the site plan, as presented, had shown Col. Glenn Rd. to be a Minor Arterial, and that there was inadequate right-of-way and improvements shown to meet the requirement of the Principal Arterial, which it is. Mr. McGetrick responded that the appropriate right-of-way and improvements would be shown on the drawing. He also indicated that all Public Works and Neighborhoods and Planing issues would be addressed. The Committee forwarded the item to the full Commission for approval of the site plan. PLANNING COMMISSION ACTION: (DECEMBER 12, 1995) Staff reported that the applicant had submitted a revised site plan which addresses the issues raised at the Subdivision Committee meeting and in the agenda "write-up". Staff reported that the deficiencies in the front landscaping requirement would be required to be addressed, and that approval of the preliminary plat, being addressed as Item 4 in the agenda being considered, would be required. The item was included on the Consent Agenda for approval, and the site plan was approved with the vote of 10 ayes, 0 nays, 0 abstentions, and 1 absent, subject to the preliminary plat being approved. 4