Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Z-4644-C Map 2
I _ , I I I I I r I I I I0. , �y� tri , ' I > : 1 } I �- i I I R t „ I I I I I t ; L I II I I _ IUI IC � I — 1 j r _ Ir rn I I I i i a I � I L I I i ; yr n TELEPHONE NOTE COORDINATE NTH OWNER AND PHONE COMPANY. PROVIDE 4" CONDUITS AS REQUIRED FOR PHONE SERVICE. /-HORi1/STROBE I _ I I I I I I I I0. �y� tri J I -.. -----0' ---------------------- -.._ I... __. 10'UTILIIYEASEM—ENT----------------- � 15' UTILITY EASEM NT I— - — -- — — — _— — — __ — — — -- -- — — — -- — -- 25' BUILDING LINE — — — WPW 975 WPW 990 STROBE (WIRING IN CONDUIT) PULL STATION 120V I-IFS1 FLOW SWITCH FAP TS TAMPER SWITCH FIRE ALARM RISER INI c:: IGI 7_,a- --- —_—_ O IMI 40OW MH, 208V POLE MTD LIGHT FIXTURES (SELECTED BY OWNER, TYPICAL) a ELECTRICAL SITE PLAN SCALE- '" = 30' 1`C- TO PANEL H. PROVIDE CIRCUIT AS REQUIRED MONUMENT SIGN - VERIFY LOCATION e GF AUT LUCAS, yO�'y MERRIOTT 8 U ASSOCIATES Z y No. 227\ ,z BASIC ELECTRICAL RE91201 1. The Electrical Subcontractor is completely responsible for how all of his work is performed; safety, in, on, or about the job site; methods of performance; and timelines In such performance. In the event he is unsatisfied with the performance of other trades, he shall set forth such complaints in writing for the Owners review. in no event shall this subcontractor expect to be specifically directed in the protection of personnel or material by the Owner, Architect, or Engineer. 2. Maintain clearances in front of electrical equipment as required by code. Report discrepuacies to AA PRIOR TO ROUCH-IN. 3. Before ordering equipment and proceeding with Work, verify with the utility company existing or available voltages shown on drawings. if voltage differs from that noted on the Drawings and in the Specifications; notify the Engineer immediately. 4. Run conduits concealed in chases, attics or cable trenches unless indicated otherwise. Run conduit exposed to view in mechanical rooms and electrical equipment rooms. Run conduit parallel or perpendicular to building lines. 5. Provide No, 12 AWGe conduit, except ulsulat d conductor or suitable pull string in empty con , ept sleeves and u nipples. 6. Building wire and cable. All conductors shall be copper (y12 minimum). 7. Install disconnect switches where indicated on Drawings and as required by code, Install a disconnecting means within sight of all motors (whether shown or not). Disconnects may be omitted where the breaker is in site and meets the code requirements 8. Provide a separate, insulated equipment grounding conductor in feeder and branch circuits. Terminate each end on a grounding lug, bus, or bushing. 9. Provide typed circuit directory under plastic for each branch circuit ponelboard. 10. Provide conduit and outlet boxes for complete telephone raceway system. ii. Telephone boxes shall be 40 mounted at standard receptacle height unless shown otherwise with single gang mud ring and blank plate. 12. Run 16 wire from telephone board to main electrical panel ground. KEY NOTES tO SPARE 3/4"C. TO ELECTRICAL ROOM U i 1 LE ROCK PLANNING COMR'ISS v1 APPr Q`e FD cUBJEGT TO THE COND 110r1S AS NOTED Lel f -PIE PVtf' EN !il0 CC" '1'0.0'N MiNUTEOID n'T D . BY: ELECTRICAL LEGEND WALL OUTLET CEILING OUTLET IQ Q f� E? •a z-ckad_<� OUTLET (NO, REFERS TO FIXT. SCHED.) LAMP HOLDER AND 100W. LAMP W/GUARD 'J' BOX AND CONNECT EQUIPMENT AS REQ'D. EXIT LIGHT - SINGLE FACE W/ BATTERY - FIXTURE TYPE 1 EXIT LIGHT - DOUBLE FACE W/ BATTERY - FIXTURE TYPE 2 FLUORESCENT FIXTURE - SHADING OR AN 'E' INDICATES EMERGENCY BODINE BALLAST ---------CONVENIENCE OUTLET AC= ABOVE COUNTER W P =WEATHERPROOF 4P ----TVSS RECPTACLE ® ------------FLOOR TELEPHONE OUTLET - WALKERBOX - VERIFY FLOOR PLATE TYPE PROVIDE TWO V C'S TO ABOVE ACCESSIBLE CEILING OR AS INDICATED O ----FLOOR CONVENIENCE OUTLET- WALKERBOX- VERIFY FLOOR PLATE TYPE 0 ------------SPECIAL PURPOSE OUTLET -020/208V) OR AS NOTED ® ----3/4' COUPLING FLUSH WITH FLOOR, THEN CONNECT WITH EQUIPMENT AS REQUIRED, OR RECEPTACLE. -W -----PUSH BUTTON 'iD HELL -0 -------------TELEVISION OUTLET -PROVIDE RACEWAYS SAME AS FOR TELEPHONE 4 ----TELEPHONE UUTLET-4X4 BOX W/ SINGLE GANG MUDRING, PLATE AND 11C TO ABOVE ACCESSIBLE CEILING, PROVIDE WIRING IF INDICATED, ® ------------VIDEO DiSPLAY TERMINAL -SAME AS TELEPHONE ® ----FIRE ALARM HORN/STROBE BO' A.F.F. ®------------FIRE ALARM SPEAKER/STROBE 80' A.F.F. © ----FIRE ALARM PULL STATION 48' A.F.F. ------------FIRE ALARM VISUAL (STROBE ONLY) 80' A.F.F. ® ----SMOKE DETECTOR D=DUCT MOUNTED Q ------------HEAT DETECTOR FAP----- FIRE ALARM PANEL E= -----PANELS LT ---------- MOTOR CONNECTION -PROVIDE DISCONNECTING MEANS Q -----TRANSFORMER ----------- CONDUIT a CEILING OR WALL (CONCEALED)- NEUTRAL, HOT L SWITCH LEG CONDUCTORS NOT SHOWN WHERE OBVIOUS. PROVIDE GROUND WIRE IN ALL COND. - - - - ---CONDUIT w UNDER FLOOR D -----DISCONNECT SWITCH F=FUSED N=NONFUSED ® ------------CONTROLLER OR STARTER (C) -----CLOCK OUTLET 6' BELOW CEILING T.C,-----------TIME CONTROL - PROVIDE 7 DAY T/C P.C------ PHOTOELECTRIC CELL N.L,-------------NIGHT LIGHT TWO LAMPS ONLY SM -----SQ. 'D' MANUAL STARTER TYPE FG -I OR FG-2,CLASS 2510 S -------------SINGLE POLE SWITCH -SWITCH EACH ROOM INDEPENDENTLY OF OTHERS UNLESS SHOWN OTHERWISE -TYPICAL FOR ALL SWITCHES S4 ------------FOUR-WAY SWITCH S2 -----DOUBLE POLE SWITCH SK -----KEYED OPERATED SWITCH SP ------------PILOT LIGHT / LIGHTED TOGGLE SWITCH - REFER TO SPECIFICATIONS FOR TYPE. S3 -----THREE-WAY SWITCH SV------------ VOLUME CONTROL SWITCH OR INTERCOM CALL BUTTON - SEE RISERS. Si -----15 MINUTE WIND UP TIMER 20 A (MARK TIME) SD ------------DIMMER PRESCOLITE REVISIONS ✓" AR' IZANSAti { ELECTRICAL SITE PLAN RRC- " RBRD jl PftI 'V0NAL .r MERRIOTT ,Q & ASSOCIATE r..,...." 2225 W. 7th LITTLE ROCK, ARKANSAS 72201 SOUTH UNIVERSITY SHOPPING CENTER LITTLE ROCK, ARKANSAS PROJECT. 2003-01 DATE: 4/4/03 F SHEET OF E1 of 1