Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Z-4644-C Map 1
II TELEPHONE NOTE COORDINATE WITH OWNER AND PHONE COMPANY. PROVIDE 4" CONDUITS AS REQUIRED FOR PHONE SERVICE. WPW 975 WPW 990 --- (WIRING IN CONDUIT) 120V : I I j,4 t'i I fry. , r.. �..... .•.•. „, :.y ...f...� q�n !««•.. �:m, RAI, p • p...�, 4 %" yp .(,j:.N3•ry Y',{...�:ry 1 C Y M'i.� 'r ! v <�. yi6y� i� � : , i? @ & 1x...i l 4...i Q:•;y iw... 3 :•. Y,..a rt x. Y F• .tel ,_,,.. r 1 S { 7 j + ql • i. i i I t`; I L.-------- i..i.._10' UTILITY EASEMENT — — — — — -- — — — — I I 15' UTILITY EASEM -NT _ 25' BUILDING LINE — — -� • I � I II I 1 1 I O I Iu ' H-15-17 ICI Z W i IC I CI i� ,G) ° � �► I F - ___ O IMI • � I� 1 I mi �- rIt Z Z ,krTi H-19- 1 1T /8-1� fl I O r i C ------ 1 M I \ TI 11101, ,m FAP HORN/STROBE s TROBC\ �--PULL STATION FLOW SWITCH TAMPER SWITCH FIRE ALARM RISER SCALE: 1" = 30' a MENT i I I I I I I I I I J 40OW MH, 208V POLE MTD LIGHT FIXTURES (SELECTED BY OWNER, TYPICAL) 17C. TO PANEL H. PROVIDE CIRCUIT AS REQUIRED MONUMENT SIGN - VERIFY LOCATION ......... ... • "'G OF U LUCAS, yO�� NIERRIOTT & U ASSOCIATES - Z a ' y No. 227 ,s BASIC ELECTRICAL REQUIREMENTS 1. The Electrical Subcontractor Is completely responsible for how all of his work is performed; safely, in, on, or about the job site; methods of performance; and timellnes in such performance. In the event he is unsatisfied with the performance of other trades, he shall set forth such complaints in writing for the Owner's review. in no event shall this subcontractor expect to be specifically directed in the protection of personnel or material by the Owner, Architect, or Engineer. 2. Maintain clearances in front of electrical equipment as required by code. Report discrepancies to A/E PRIOR TO ROUGH -IN. J. Before ordering equipment and proceeding with Work, verify with the utility company existing or available voltages shown on drawings. if voltage differs from that noted on the Drawings and in the Specifications; notify the Engineer immediately. 4. Run conduits concealed in chases, attics or cable trenches unless indicated otherwise. Ruu conduit exposed to view In mechanical rooms and electrical equipment rooms. Run conduit poralici or perpendicular to budding lines. 5, Provide No. 12 AWG insulated conductor or suitable pull string in empty conduit, except sleeves and nipples. 6. Building wire and cable. All conductors shall be copper (/12 minimum). 7. Install disconnect switches where indicated on Drawings and as required by code. Install a disconnecting means within sight of all motors (whether shown or not). Disconnects may be omitted where the breaker is in site and meets the code requirements B. Provide a separate, insulated equipment grounding conductor In feeder and branch circuits. Terminate each end on a grounding lug, bus, or bushing. 9. Provide typed circuit directory under plastic for each branch circuit ponelboard. 10. Provide conduit and outlet boxes for complete telephone raceway system. it. Telephone boxes shall be 4x4 mounted at standard receptacle height unless shown otherwise with single gang mud ring and blank plate. 12, Run #6 wire from telephone board to main electrical panel ground. rf/11\Tr 0- AII AS ItBGi H8ED Pit 1y 5,tD Y A L 4-3-03 KEY NOTES lO SPARE 3/4'C. TO ELECTRICAL ROOM ELECTRICAL LEGEND WALL OUTLET CEILING OUTLET 0 ►© o i' OUTLET (NO, REFERS TO FIXT. SCHED,) LAMP HOLDER AND 100W. LAMP W/GUARD 'J' BOX AND CONNECT EQUIPMENT AS REQ'D, EXIT LIGHT - SINGLE FACE W/ BATTERY - FIXTURE TYPE I EXIT LIGHT - DOUBLE FACE W/ BATTERY - FIXTURE TYPE 2 FLUORESCENT FIXTURE - SHADING OR AN 'E' INDICATES EMERGENCY BODINE BALLAST or ---------CONVENIENCE OUTLET AC= ABOVE COUNTER W.P. =WEATHERPROOF ft----TVSS RECPTACLE ®------------FLOOR TELEPHONE OUTLET - WALKERBOX - VERIFY FLUOR PLATE TYPE PROVIDE TWO V C'S TO ABOVE ACCESSIBLE CEILING OR AS INDICATED O ----FLOOR CONVENIENCE OUTLET- WALKERBOX- VERIFY FLOOR PLATE TYPE ®------------SPECIAL PURPOSE OUTLET -(120/208V) OR AS NOTED ® ----3/4' COUPLING FLUSH WITH FLOOR, THEN CONNECT WITH EQUIPMENT AS REQUIRED, OR RECEPTACLE, -IB -----PUSH BUTTON -19D HELL 6 -------------TELEVISION OUTLET -PROVIDE RACEWAYS SAME AS FOR TELEPHONE 4 ----TELEPHONE OUTLET -04 BOX W/ SINGLE GANG MUDRING, PLATE AND 1'C TO ABOVE ACCESSIBLE CEILING. PROVIDE WiRING IF INDICATED. ® ------------VIDEO DISPLAY TERMINAL -SAME AS TELEPHONE ® ----FIRE ALARM HORN/STROBE 80' A.F.F. ®------------FIRE ALARM SPEAKER/STROBE 80' A.F.F. © ----FIRE ALARM PULL STATION 48' A.F.F. Q ------------FIRE ALARM VISUAL (STROBE ONLY) 80' A.F.F. Qs ----SMOKE DETECTOR D=DUCT MOUNTED NQ ------------HEAT DETECTOR FAP----- FIRE ALARM PANEL Q -----PANELS �}---------- MOTOR CONNECTION -PROVIDE DISCONNECTING MEANS Q ------TRANSFORMER }'-----------CONDUIT w CEILING OR WALL (CONCEALED)- NEUTRAL, HOT L SWITCH LEG CONDUCTORS NOT SHOWN WHERE OBVIOUS. PROVIDE GROUND WIRE IN ALL COND, - - - - ---CONDUIT r UNDER FLOOR ❑ -----DISCONNECT SWITCH F=FUSED N=NONFUSED ® ------ _----- CONTROLLER OR STARTER m -----CLOCK OUTLET 6' BELOW CEILING T,C,-----------TIME CONTROL - PROVIDE 7 DAY T/C P•C------ PHOTOELECTRIC CELL N.L.-------------NIGHT LIGHT TWO LAMPS ONLY SM -----SQ, 'D' MANUAL STARTER TYPE FG -1 OR FG-2,CLASS 2510 S -------------SINGLE POLE SWITCH -SWITCH EACH ROOM iNDEPENpENTLY 11 OTHERS UNLESS SHOWN OTHERWISE -TYPICAL FUR ALL SWITCHES S4 ------------- FOUR-WAY SWITCH S2 --__-DOUBLE POLE SWITCH SK -----KEYED OPERATED SWITCH SP ------------PILOT LIGHT / LIGHTED TOGGLE SWITCH - REFER TO SPECIFICATIONS FOR TYPE. S3 -----THREE-WAY SWITCH SV ------------VOLUME CONTROL SWITCH OR INTERCOM CALL BUTTON - SEE RISERS. Si -----15 MINUTE WIND UP TIMER 20 A (MARK TIME) SD ------------DIMMER PRESCOLITE LITTLE fTOC{< PLANNiNG COMMICTO,( A� NO ,ClI T I ' 1 I I : I , .......... p 1 � iy} i E F j x • I I , - 5 {,, • i-. i I I I i � I I II TELEPHONE NOTE COORDINATE WITH OWNER AND PHONE COMPANY. PROVIDE 4" CONDUITS AS REQUIRED FOR PHONE SERVICE. WPW 975 WPW 990 --- (WIRING IN CONDUIT) 120V : I I j,4 t'i I fry. , r.. �..... .•.•. „, :.y ...f...� q�n !««•.. �:m, RAI, p • p...�, 4 %" yp .(,j:.N3•ry Y',{...�:ry 1 C Y M'i.� 'r ! v <�. yi6y� i� � : , i? @ & 1x...i l 4...i Q:•;y iw... 3 :•. Y,..a rt x. Y F• .tel ,_,,.. r 1 S { 7 j + ql • i. i i I t`; I L.-------- i..i.._10' UTILITY EASEMENT — — — — — -- — — — — I I 15' UTILITY EASEM -NT _ 25' BUILDING LINE — — -� • I � I II I 1 1 I O I Iu ' H-15-17 ICI Z W i IC I CI i� ,G) ° � �► I F - ___ O IMI • � I� 1 I mi �- rIt Z Z ,krTi H-19- 1 1T /8-1� fl I O r i C ------ 1 M I \ TI 11101, ,m FAP HORN/STROBE s TROBC\ �--PULL STATION FLOW SWITCH TAMPER SWITCH FIRE ALARM RISER SCALE: 1" = 30' a MENT i I I I I I I I I I J 40OW MH, 208V POLE MTD LIGHT FIXTURES (SELECTED BY OWNER, TYPICAL) 17C. TO PANEL H. PROVIDE CIRCUIT AS REQUIRED MONUMENT SIGN - VERIFY LOCATION ......... ... • "'G OF U LUCAS, yO�� NIERRIOTT & U ASSOCIATES - Z a ' y No. 227 ,s BASIC ELECTRICAL REQUIREMENTS 1. The Electrical Subcontractor Is completely responsible for how all of his work is performed; safely, in, on, or about the job site; methods of performance; and timellnes in such performance. In the event he is unsatisfied with the performance of other trades, he shall set forth such complaints in writing for the Owner's review. in no event shall this subcontractor expect to be specifically directed in the protection of personnel or material by the Owner, Architect, or Engineer. 2. Maintain clearances in front of electrical equipment as required by code. Report discrepancies to A/E PRIOR TO ROUGH -IN. J. Before ordering equipment and proceeding with Work, verify with the utility company existing or available voltages shown on drawings. if voltage differs from that noted on the Drawings and in the Specifications; notify the Engineer immediately. 4. Run conduits concealed in chases, attics or cable trenches unless indicated otherwise. Ruu conduit exposed to view In mechanical rooms and electrical equipment rooms. Run conduit poralici or perpendicular to budding lines. 5, Provide No. 12 AWG insulated conductor or suitable pull string in empty conduit, except sleeves and nipples. 6. Building wire and cable. All conductors shall be copper (/12 minimum). 7. Install disconnect switches where indicated on Drawings and as required by code. Install a disconnecting means within sight of all motors (whether shown or not). Disconnects may be omitted where the breaker is in site and meets the code requirements B. Provide a separate, insulated equipment grounding conductor In feeder and branch circuits. Terminate each end on a grounding lug, bus, or bushing. 9. Provide typed circuit directory under plastic for each branch circuit ponelboard. 10. Provide conduit and outlet boxes for complete telephone raceway system. it. Telephone boxes shall be 4x4 mounted at standard receptacle height unless shown otherwise with single gang mud ring and blank plate. 12, Run #6 wire from telephone board to main electrical panel ground. rf/11\Tr 0- AII AS ItBGi H8ED Pit 1y 5,tD Y A L 4-3-03 KEY NOTES lO SPARE 3/4'C. TO ELECTRICAL ROOM ELECTRICAL LEGEND WALL OUTLET CEILING OUTLET 0 ►© o i' OUTLET (NO, REFERS TO FIXT. SCHED,) LAMP HOLDER AND 100W. LAMP W/GUARD 'J' BOX AND CONNECT EQUIPMENT AS REQ'D, EXIT LIGHT - SINGLE FACE W/ BATTERY - FIXTURE TYPE I EXIT LIGHT - DOUBLE FACE W/ BATTERY - FIXTURE TYPE 2 FLUORESCENT FIXTURE - SHADING OR AN 'E' INDICATES EMERGENCY BODINE BALLAST or ---------CONVENIENCE OUTLET AC= ABOVE COUNTER W.P. =WEATHERPROOF ft----TVSS RECPTACLE ®------------FLOOR TELEPHONE OUTLET - WALKERBOX - VERIFY FLUOR PLATE TYPE PROVIDE TWO V C'S TO ABOVE ACCESSIBLE CEILING OR AS INDICATED O ----FLOOR CONVENIENCE OUTLET- WALKERBOX- VERIFY FLOOR PLATE TYPE ®------------SPECIAL PURPOSE OUTLET -(120/208V) OR AS NOTED ® ----3/4' COUPLING FLUSH WITH FLOOR, THEN CONNECT WITH EQUIPMENT AS REQUIRED, OR RECEPTACLE, -IB -----PUSH BUTTON -19D HELL 6 -------------TELEVISION OUTLET -PROVIDE RACEWAYS SAME AS FOR TELEPHONE 4 ----TELEPHONE OUTLET -04 BOX W/ SINGLE GANG MUDRING, PLATE AND 1'C TO ABOVE ACCESSIBLE CEILING. PROVIDE WiRING IF INDICATED. ® ------------VIDEO DISPLAY TERMINAL -SAME AS TELEPHONE ® ----FIRE ALARM HORN/STROBE 80' A.F.F. ®------------FIRE ALARM SPEAKER/STROBE 80' A.F.F. © ----FIRE ALARM PULL STATION 48' A.F.F. Q ------------FIRE ALARM VISUAL (STROBE ONLY) 80' A.F.F. Qs ----SMOKE DETECTOR D=DUCT MOUNTED NQ ------------HEAT DETECTOR FAP----- FIRE ALARM PANEL Q -----PANELS �}---------- MOTOR CONNECTION -PROVIDE DISCONNECTING MEANS Q ------TRANSFORMER }'-----------CONDUIT w CEILING OR WALL (CONCEALED)- NEUTRAL, HOT L SWITCH LEG CONDUCTORS NOT SHOWN WHERE OBVIOUS. PROVIDE GROUND WIRE IN ALL COND, - - - - ---CONDUIT r UNDER FLOOR ❑ -----DISCONNECT SWITCH F=FUSED N=NONFUSED ® ------ _----- CONTROLLER OR STARTER m -----CLOCK OUTLET 6' BELOW CEILING T,C,-----------TIME CONTROL - PROVIDE 7 DAY T/C P•C------ PHOTOELECTRIC CELL N.L.-------------NIGHT LIGHT TWO LAMPS ONLY SM -----SQ, 'D' MANUAL STARTER TYPE FG -1 OR FG-2,CLASS 2510 S -------------SINGLE POLE SWITCH -SWITCH EACH ROOM iNDEPENpENTLY 11 OTHERS UNLESS SHOWN OTHERWISE -TYPICAL FUR ALL SWITCHES S4 ------------- FOUR-WAY SWITCH S2 --__-DOUBLE POLE SWITCH SK -----KEYED OPERATED SWITCH SP ------------PILOT LIGHT / LIGHTED TOGGLE SWITCH - REFER TO SPECIFICATIONS FOR TYPE. S3 -----THREE-WAY SWITCH SV ------------VOLUME CONTROL SWITCH OR INTERCOM CALL BUTTON - SEE RISERS. Si -----15 MINUTE WIND UP TIMER 20 A (MARK TIME) SD ------------DIMMER PRESCOLITE LITTLE fTOC{< PLANNiNG COMMICTO,( A� NO ,ClI T C, t V: 1