HomeMy WebLinkAboutZ-4635-C ApplicationC3
® CUP
/Li
dl IN
EP p
c 17 ryyl
PCD ❑
fQEgg
LU a
� PD C7
®q �. R ° THIS SITE FQ
BASELINE Rrk 0. o
_ ❑, � a m o BASEUNE Rt),
Q�
CJS
" 57DN CT �c
�1
UJ
E►Fz� a
G
p`O-f-F
C3 C3
C] o 0 0 0 0 0 0 0 0
6004 vA 9vvv�,
DAVMAR=DR
RICHSMrgy
f A a PD4t 0�
FIj O
o � I 5 G7 � �7
Area Zoning
In
Case: Z -4635-C
Location: 10600 1-30
Ward: 7
PD: 15
CT: 41.03
TRS: T1 S R13W3
7
ea A
R2
010000 400 Feet
PCD
I4 a
I'so ccu,p
01.
THIS SITE 0 0 0
C3 C3
CD CD ED Cm CD 0 cD
- — — — — — — — — — —
j ffi
�j
NOW
M
Land Use Plan
Case: Z -4635-C
Location: 10600 1-30
Ward: 7
PD: 15
CT. 41.03
TRS: T1 R13W3
R.
J
C3
UP
R2
0100,00 400 Feet
R-2
1
R-2
R-2
-3
-3
I Z-4635-0 00600 INTERS ATE 30 Y P.
C.
1111111111011111111111111111111111111 2016006536
PRESENTED: 02-03.2016 01:23 40 PM RECORDED: 02-03-2016 01:31 04 PM
In Official Records of Larry Crane Circuit/County Clerk
ORDINANCE NPj194, AR FEE $20.00
"4' , UlA5K1 c !ffA 'E' ORDINANCE TO APPROVE A PLANNED ZONING DEVELOPMENT
4 AND ESTABLISH A PLANNED COMMERCIAL DISTRICT TITLED
5 HUFFSTUTLAR PROPERTY LONG -FORM PCD, LOCATED AT 10600
6 INTERSTATE 30 (Z -4635-C), LITTLE ROCK, ARKANSAS, AMENDING
7 THE OFFICIAL ZONING MAP OF THE CITY OF LITTLE ROCK,
8 ARKANSAS; AND FOR OTHER PURPOSES.
9
10 BE IT ORDAINED BY THE BOARD OF DIRECTORS OF THE CITY OF LITTLE ROCK,
11 ARKANSAS.
12 SECTION 1. That the zoning classification of the following described property be changed from C-
13 3, General Commercial District, to PCD, Planned Commercial District:
14 Z -4635-C: Part of the fractional Northwest Quarter of the northeast quarter of
15 Section 3, Township 1 South, Range 13 West, Pulaski County, Arkansas, more
16 particularly described as follows: Commencing at the northwest corner of said
17 fractional northwest quarter of the northeast quarter; thence south 01'24'18" west
18 thirty (30) feet along the west line of said fractional northwest quarter of the northeast
19 quarter to the south right-of-way line of Baseline Road; thence south 87°57'10" east
20 along said south right-of-way line thirty (30) feet to a point on the east right-of-way
21 line of Childers Road and the point of beginning; thence continuing along the south
22 right-of-way line of Baseline Road, south 87050'34" east 483.02 feet; thence leaving
23 said south right-of-way line, south 01°26'29" west 838.96 feet to a point on the north
24 right-of-way line of Interstate Route No. 30; thence along said north right-of-way line,
25 south 66125122" west 532.25 feet to a point on the east right-of-way line of Childers
26 Road; thence along said east right-of-way line north 01124'18" east 1,070.09 feet to
27 the point of beginning containing 10.58 acres, more or less.
28 SECTION 2. That the preliminary site development plan/plat be approved as recommended by the
29 Little Rock Planning Commission.
30 SECTION 3. That the change in zoning classification contemplated for Huffstutlar Property Long -
31 Form PCD, located at 10600 Interstate 30 (Z -4635-C), is conditioned upon obtaining final plan approval
32 within the time specified by Chapter 36, Article VII, Section 36-454 (e) of the Code of Ordinances.
33
[Page 1 of 21
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
SECTION 4. That this ordinance shall not take effect and be in full force until the final plan approval.
SECTION 5. That the map referred to in Chapter 36 of the Code of Ordinances of the City of Little
Rock, Arkansas, and designated district map be and is hereby amended to the extent and in the respects
necessary to affect and designate the change provided for in Section I hereof.
SECTION 6. Severability. In the event any title, section, paragraph, item, sentence, clause, phrase,
or word of this ordinance is declared or adjudged to be invalid or unconstitutional, such declaration or
adjudication shall not affect the remaining portions of the ordinance which shall remain in full force and
effect as if the portion so declared or adjudged invalid or unconstitutional was not originally a part of the
ordinance.
SECTION 7. Repealer. All laws, ordinances, resolutions, or parts of the same that are inconsistent
with the provisions of this ordinance are hereby repealed to the extent of such inconsistency.
PASSED: February 2, 2016
IR
APPROVED-
n ley, City Clerk Mark Stodola, Mayor
D AS TO LEGAL FORM:
Thomas M. Carpenter, City Attorne
//
911
//
//
//
//
[Page 2 of 21
OHM
Case:
Case: Z -4635-C
Location: 10600 1-30
Ward: 7
PD: 15 010000 400 Feet
CT 41.03
TRS: T1S R13W3
C3
CUP
PCD
0
50
d oa OQ
Q
0
o °
El
O .1
d� Qat`
a 0 w El d 0� PID O
w
�0 x. zE 1 0 0
o�� THIS SITE E s
ELRp
v
MA
S. N:
t
o
C3
p o 0 0 0 0 0 0 0 0
000aApv-ea��
i2' ❑
3,
:r:
, : t
4L+OAZR-DR
7
_ RICHSMITH-DR
°'P p pock
Land Use Plan.
C3
C3
UP
00
R2 1
Case: Z -4635-C
Location: 10600 1-30
Ward: 7
PD: 15 010000 400 Feet
CT. 41.03
TRS: T1 S R1 3W3
R-2
R-2
R-2
Z -4635-C 0 a60�
INTERSTATE 30 Y 0 P. C. D H
Board follow-up
Re: Z -4635-C, Huffstutlar Property Long -form PCD located at 10600 1-30
Staff was asked to provide additional information regarding fencing proposed along the Baseline Road
frontage in conjunction with the proposed Huffstutlar Property Long -form PCD located at 10600
Interstate 30.
The applicant is proposing to enclose the entirety of the property with a six (6) foot tall, vinyl coated
chain link fence with barbed wire placed on top of the fence in accordance with the fence regulations of
Section 36-516 of the City Code. No razor wire is proposed.
Along the Baseline Road perimeter, the fence will be set back at the twenty-five (25) foot setback line,
not on the property line. Landscaping to comply with Chapter 15, the Landscape Ordinance, will be
placed between the fence and the Baseline Road property line. Required landscaping will consist of trees
and shrubbery.
If additional information is needed, please advise.
OFFICE OF THE CITY MANAGER
LITTLE ROCK, ARKANSAS
BOARD OF DIRECTORS COMMUNICATION
FEBRUARY 2, 2016 AGENDA
Subject
An Ordinance establishing
a Planned Zoning District
titled Huffstutlar Property
Long -form PCD, located at
10600I-30. (Z -4635-C)
Submitted by:
Department of Planning
and Development
SYNOPSIS
FISCAL IMPACT
RECOMMENDATION
CITIZEN
PARTICIPATION
Action Required
Ordinance
Resolution
Approval
Information Report
Approved By
Bruce T. Moore
The applicant is requesting a rezoning of this site from C-3,
General Commercial District, to Planned Commercial
Development, PCD, to add equipment sales and service as
an allowable use for the site.
None.
Staff recommends approval of the requested PCD zoning.
The Planning Commission voted to recommend approval
of the PCD zoning by a vote of 10 ayes, 0 noes and
1 absent.
The Planning Commission reviewed the proposed PCD
request at its January 7, 2016, meeting and there was one
interested party present. All property owners located
within 200 -feet of the site along with Southwest United for
Progress were notified of the Public Hearing.
BACKGROUND
The applicant is requesting to rezone the site from C-3,
General Commercial District to Planned Commercial
Development, PCD, to add equipment sales and service as
an allowable use for the site. The site plan includes areas
for outdoor display of equipment which will be placed on a
limestone surface within the 45 -foot building setback.
Two (2) new buildings are proposed with a total of 40,785
square feet of floor area. The maximum building height
proposed is 35 -feet. The buildings will be constructed with
metal siding. All site lighting is to be low level and
directional, directed downward and into the site. The site
contains 10.58 -acres. The proposed building coverage is
ten (10) percent, the paved areas will cover thirty (30)
percent and the landscaped area includes sixty (60) percent
of the site.
The days and hours of operation are from 6:00 am to 7:00
pm Monday through Saturday. There may be an occasion
when the business elects to open on Sunday as well. The
hours for Sunday will be 12:00 noon to 7:00 pm.
Please see the attached Planning Commission minute
record and site plan for the applicant's specific
development proposal and the staff analysis and
recommendation.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
ORDINANCE NO.
AN ORDINANCE APPROVING A PLANNED ZONING
DEVELOPMENT AND ESTABLISHING A PLANNED
COMMERCIAL DISTRICT TITLED HUFFSTUTLAR
PROPERTY LONG -FORM PCD, LOCATED AT 10600 I-30
(Z -4635-C), LITTLE ROCK, ARKANSAS, AMENDING THE
OFFICIAL ZONING MAP OF THE CITY OF LITTLE ROCK;
AND FOR OTHER PURPOSES.
BE IT ORDAINED BY THE BOARD OF DIRECTORS OF THE CITY OF LITTLE
ROCK, ARKANSAS.
SECTION 1. That the zoning classification of the following described property
be changed from C-3, General Commercial District to PCD, Planned Commercial District:
Z -4635-C - Part of the fractional Northwest Quarter of the Northeast
Quarter of Section 3, Township 1 South, Range 13 West, Pulaski
County, Arkansas, more particularly described as follows:
Commencing at the Northwest corner of said fractional Northwest
Quarter of the Northeast Quarter; thence South 01024'18" West
30.0 feet along the west line of said fractional Northwest Quarter of
the Northeast Quarter to the south right of way line of Baseline Road;
thence South 87057'10" East along said south right of way line
30.0 feet to a point on the east right of way line of Childers Road and
the point of beginning; thence continuing along the south right of way
line of Baseline Road, South 87150'34" East 483.02 feet; thence
leaving said south right of way line, South 01°26129" West 838.96 feet
to a point on the North right of way line of Interstate Route No. 30;
thence along said north right of way line, South 66125'22" West
532.25 feet to a point on the east right of way line of Childers Road;
Page 1 of 3
I thence along said east right of way line North 01°24'18" East
2 1070.09 feet to the point of beginning containing 10.58 acres more
3 or less.
4
5 SECTION 2. That the preliminary site development plan/plat be approved as
6 recommended by the Little Rock Planning Commission.
7
8 SECTION 3. That the change in zoning classification contemplated for
9 Huffstutlar Property Long -form PCD, located at 10600 I-30 (Z -4635-C) is conditioned upon
10 obtaining final plan approval within the time specified by Chapter 36, Article VII, Section
11 36-454 (e) of the Code of Ordinances.
12
13 SECTION 4. That this Ordinance shall not take effect and be in full force until
14 the final plan approval.
15
16 SECTION 5. That the map referred to in Chapter 36 of the Code of Ordinances
17 of the City of Little Rock, Arkansas, and designated district map be and is hereby amended to
18 the extent and in the respects necessary to affect and designate the change provided for in
19 Section 1 hereof.
20
21 SECTION 6. Severability. In the event any title, section, paragraph, item,
22 sentence, clause, phrase, or word of this ordinance is declared or adjudged to be invalid or
23 unconstitutional, such declaration or adjudication shall not affect the remaining portions of
24 the ordinance which shall remain in full force and effect as if the portion so declared or
25 adjudged invalid or unconstitutional was not originally a part of the ordinance.
26
27 SECTION 7. Repealer. All laws, ordinances, resolutions, or parts of the same
28 that are inconsistent with the provisions of this ordinance are hereby repealed to the extent of
29 such inconsistency.
30
31
Page 2 of 3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
PASSED:
ATTEST:
City Clerk
APPROVED AS TO FORM:
City Attorney
APPROVED:
Mayor
Page 3 of 3
F-. •
Area
mooning
Case: Z -4635-C
Location: 10600 1-30
Ward: 7
PD: 15 0100.00 400 Feet
CT. 41.03
TRS: TIS R13W3
Land Use Plan
Case: Z -4635-C
Location: 10600 1-30
Ward: 7
PD: 15 010000 400 Feet
v
CT: 41.03
TRS: T1 S R13W3
R-2
R-2
R-2
-3
-3
Z-4635-0 0 0600 INTERSTATE 30 Y 0 P.C. "vI
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
February 16, 2016
McGetrick and McGetrick Engineering
P.O. Box 30441
Little Rock, AR 72210
Re- Z -4635-C — Huffstutlar Property Long -form PCD, located at 10600 1-30
Dear Sir or Madam:
Enclosed please find a copy of an Ordinance adopted by the Board of Directors at their
February'1, 2016, Public Hearing approving the above referenced development.
If you have any questions concerning this ordinance, please feel free to call me at 371-
6821.
Sincerely,
Donna James, AICP
Subdivision Administrator
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
January 8, 2016
McGetrick and McGetrick Engineering
P.O. Box 30441
Little Rock, AR 72210
Re: Z -4635-C — Huffstutlar Property Long -form PCD, located at 10600 1-30
Dear Sirs:
This is to advise you that in connection with your request concerning the above referenced
file number the following action was taken by the Planning Commission at its meeting on
January 7, 2016:
Approved with conditions.
X Recommended approval with conditions.
Recommended approval as submitted.
Denied your request as submitted.
Deferred to the
Other:
Meeting.
This item will be forwarded to the Little Rock Board of Directors for final action. You or your
representative will need to be present at the Board of Directors meeting to address any
questions which may arise. The meeting date has tentatively been set for February 2,
2016. The meeting begins at 6:00 pm and is held in the Board of Directors Chambers, 500
West Markham Street, 2nd floor. If you have any questions please do not hesitate to contact
me at 371-6821.
Respectfully,
Donna James, AICP
Subdivision Administrator
sfpzd.doc
APPLICATION FOR
PLANNED ZONING DEVELOPMENT - SHORT FORM
CASE FILE NO. - b IDS
03/01/10
PI G COMMISSION MEETING DOCKETED FOR -I AVI 7
at r & m. %
Application is hereby made to the Board of Directors of Little Rock, Arkansas through the Planning
Commission pursuant to Arkansas law on City planning, Act 186 of 1957, Acts of Arkansas, and Section
36 of the Little Rock Code of Ordinances as amended, petitioning for classification of the following
described area as a Short Form Planned Zoning Development.
Legal Description:.IZ
Title to this property is vested in:rUIG�,�
If an individual other than the title holder files this application, attachment of a letter is required
authorizing this person to act on behalf of the title holder.
It is desired that the boundaries shown on the District Map be amended and that this area be amended
and that this area be reclassified from the present District
to _ C 2 District.
Present Use of Property:_ 1y
Desired Use of Pronertv:
It is understood that notice of the public hearing hereon before the Little Rock Planning Commission
will be published at least .Fifteen (15) days prior to said hearing in a daily newspaper as required by Act
186 of the 1957 Acts of Arkansas and Section 23 of said Ordinance, and that notice of preliminary
hearing before the Commission must be circulated by the applicant to all other parties in interest,
including owners of land within 200 feet of the boundary of the area under consideration as required by
the rules of the Commission, an that the cost of these not es hall be borne by the applicantPO 170�.
(OWNERADDRESS: P? f
L. �rrz AA 77-2/ d
or [AGENT}T �� HOME PHONE:
BUSINESS PHONE:��
FILING FEE: P.C. APPROVED: `
Collectors P.C. DENIED:
$� paid stamp BD. OF DIR. APPROVED: ,Ji �i L
here ORDIN NCE NO. I
Signa ecretary of Commission or
Authorized Agent
sfpzd.doc
ITEM
FILE ]
LOCATION:
INFORMATION SHEET FOR
SUBDIVISION, PZD's ZONING
OR SUBDIVISION SITE PLAN REVIEWS
DATE _/J / X? 1 2 D l g*
DEVELOPER: ty\ i
STREET ADDRESS �f
CITY/STATE/ZIP 1 U
TELEPHONE NO.
ENGINEER:c'G �T►�� Cie r
STREET ADDRESS��po lI �ip� piL�l� Ly �d
CITY/STATE/ZIP 4 / TT r q��c
TELEPHONE NO. O �Slr�
AREA SNUMBER OF LOTS I
FT. NEW STREET
ZONING _ r- PROPOSED USES IC
PLANNING DISTRICT CENSUS TRACT
VARIANCES REQUESTED
1.)
2.)
3.)
4.)
03/01/10
lLp4q W,
sfpzd.doc 03/01/10
STREET RIGHT-OF-WAY
AGREEMENT
CASE NO. Z- LOCATION/ADDRESS
DATE 2P I
DOCKETED FOR MEETING ON -Tp* "& `/ y �n
/ I, u h R r41 do hereby agree/diagrwto dedicate to the public
any needed right-of-way as required by the Master Street Plan for a public street abutting property on
which I am requesting Planned Zoning District.
X I, RuA%k agreef wt to provide at my expense an
easement deed and/or other documents as necessary conveying such right-of-way to the public.
�APPLiCANT10WNER (?LK
�y STv�'� h� It ("� DATE
(IF THE ABOVE SIGNATURE REPRESENTS AN APPLICANT OTHER THAN THE TITLE
HOLDER, ATTACHMENT OF A LETTER IS REQUIRED AUTHORIZING THIS PERSON TO ACT
IN BEHALF OF THE TITLE-HOLDER.)
sfpzd.doc
AFFIDAVIT
03/01/10
ZA IA l -j v F F $+,4 (A IL , ,5-1ee I SSOA iZ vc-f f '6 'hti (AJ' 1 A ,4 f , ►+�t=F=c��1.��
L J& JOC A A,k L TUS T i A Od l 54-1"5 certify by my signature below that I hereby
authorize ,Ag22e/G&,:: , rrrf° y,Bl�lcto act as my agent regarding the
e- > _ of the below described property.
Property described as:
e 911 -17th
Z-1 Z
ignature of Title Hold Date
Subscribed and sworn to me a Notary Public on this
o 0t
:a,s
,,�►►►11111 11111111ll►
v H EIV "rfrrr
�� ,-�° ��� y Notary Public
o
,.. _
My Commission Expires: pL��' '
day of
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF
LAND
November 25, 2015
Southwest Little Rock United for Progress
Ms. Patricia W. Gee
8409 Dowan Drive
Little Rock, AR 72209
REQUEST: Huffstutlar Property Long -form PCD Z -4635-C a request to rezone the
site from C-3 General Commercial District to Planned Development Commercial to
allow the construction of a new building to be used as heavy a ui ment sales and
service.
GENERAL LOCATION OR ADDRESS: 10600 1 -
OWNED BY/APPLICANT: Pat McGetrick — McGetrick Engineering Agent
501.455.889
NOTICE IS HEREBY GIVEN THAT an application for a Planned Zoning Develo ment of
the above property has been filed with the Department of Planning and Development. A
public hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on January 7,
2016 at 4:00 P.M. This notice is provided in order to assure that neighborhood
associations are aware of issues that may affect their neighborhood. Information
requests should be directed to the Planning staff at 371-4790.
Tony Bozynski
Director of Planning and Development
sfpzd.doc
NOTICE OF PUBLIC HEARING BEFORE
THE LITTLE ROCK PLANNING COMMISSION
ON AN APPLICATION TO ESTABLISH A
SHORT -FORM PLANNED ZONING DEVELOPMENT
To ALL owners of land lying within 200 feet of the boundary of the property located at:
Address:
03/01/10
General Location: 4%r " % Pe W5 r RI
plip
rI I` / r 11! a
NOTICE IS HEREBY GIVEN THAT an application for a Planned Zoning Development of the above
property requesting a change of classification from G w_3 District to et
has been filed with the Department of Planning and Development. A public
hearing on said application will be held by the Little Rock Planning Commission in the Board of
Directors Chamber, Second Floor, City Hall, on J' & i Z1016 --at 4-6 D
p.m.
ALL PARTIES IN INTEREST MAY APPEAR and be heard at said time and place, or may notify the
Planning Commission of their views on this matter by letter. All persons interested in this request are
invited to call or visit the Department of Planning and Development, 723 W. Markham, 3714790, and
to review the application and discuss same with the Planning staff.
AFFIDAVIT
I hereby certify that I have notified all the property owners of record within 200 feet of the above
property that subject property is being considered for rezoning and that a Public Hearing will be held by
the Little Rock Planning Commission at the time and place described above.
rn
Applicant (owner or authorized agent) �
�vae l / l W 2 ��
(Date)
M
Ln
ru
Ln
M
Ln
ru
.n
0
I=
r3
0
zr
-a
r3
Ln
a
0
r_
Temple Missionary Baptist Church Addition
10710 Interstate 30
Little Rock, AR 72209
r%_
0
M
Ln
M
Ln
ru
0
C3
0
0
.A
O
Ln
a
C3
r -
North Little Rock, AR 72117
a
n-
Domestic
RECEIPT
M
Domestic Mail Only
1ABOT, AR 7202
Ln
AUSTIN P AR 72007
--fir
M
• WALDRON., Alt 729x8.
-
Ln
.090edMail Foeru
�
O
0
5 tro Sarwiom 8 Fees "opt bm 001V
❑ Receipt eipt t S
0
.
E� 18 20157
O
11Rahrn Recut ci ti
Postmark!
0
❑ CedllNd Ma Realdad Dtd.ary $ r
Here
C3
L] Adult Sltinata RegMed
0---
rd
0
❑MW Si9naaaa ReMrlaled DQvW C
_
g Zp15
S° $0.49
Po,tage ,,yy_
49
�
2 2
OT*W
To�F1_,."o and Fax.
i
121211
$3.94
Ln
S
F
a
"'Arnold Pearson
54 Jennie Leigh Drive
, 64 Ridgefield Drive
rr-
r%_
Austin, AR 72207
Ward, AR 72176
Postal
MAILD
RECEIPT
Co
DomesticCERTIFIED
ti
•LITTLE
Ln
WFY ,��71?0
G-
tn
C-otttaedMimi Fee i3.45
0
ru
s
1.
ra crs Frest�c xle
L
❑ ROM RBeeWt QtmdwW 3
0
0 �r
181
0
❑Adult RequYed S
❑Adt*SWsbm ReWlct dD*W Y$
0
$0.49
'�
ToW3 Posinga and Fear
f 712112 5
C3
$3.94
rLn
' Erwin and Diana Huggler
Ir
9900 W. Baseline Road
`
Little Rock, AR 72209-5809
r%_
0
M
Ln
M
Ln
ru
0
C3
0
0
.A
O
Ln
a
C3
r -
North Little Rock, AR 72117
a
n-
CERTIFIED F 9
RECEIPT
rLi
Domestic Mail Only
1ABOT, AR 7202
rn
,
Ln
corlsnea Mad Fea $3.46
• WALDRON., Alt 729x8.
U S E
m
LnCertified
Mall Fog $3.46
�
0033
tri 07
O
0
Ex" - a oa9 k+@c* t lc add
0
❑ Adult Slaw" Raquhed
{] Aa" s&7u we ReaMead Du*a
C3
:I -s
❑ReeanR.atlptt�W fr
as
C3
❑ Roam RecW W—onic)
s
C3
❑ Cetuaed Mail RMM&Ad Deawry
0---
rd
0
❑Mft
C] 54uhua cid
_
g Zp15
C3
Po,tage ,,yy_
49
OT*W
Poam9a and FOM
i
121211
$3.94
Ln
s
Atkinson Properties, LLC
F
a
0
, 64 Ridgefield Drive
r%_
Ward, AR 72176
r%_
0
M
Ln
M
Ln
ru
0
C3
0
0
.A
O
Ln
a
C3
r -
North Little Rock, AR 72117
a
n-
.. -
ru
..
Ln
1ABOT, AR 7202
Ln
corlsnea Mad Fea $3.46
ru
�
$pt4IC0S aestauaxeeoc
�
❑ Return Reagpt p.�dmpt9
❑Cwt.ntMallR9 eehWQ"
O
0
❑pwtllbd Md ReeMtded
0
❑ Adult Slaw" Raquhed
{] Aa" s&7u we ReaMead Du*a
C3
:I -s
PQetaga
$0.49
-
"n
C3
Toto Postage and Fans
$3.94
s
"'r.q
`Centennial Bank
0
c/o P.O. Box 1028
N
Cabot, AR 72023
j
�o
Domestic
RECEIPT
CERTIFIED MAILO
For d0very information.
Domestic
ru
at jy�V�VUSpS,CCM4
m
For deii[VM information- visit
ALIT �_ AEi 72022
our viebsite at www. usps.cop]O�.
9 A L
Ln ru
cert sped nsna Fce $3.45
Ln
ru
° s�
$
tri Aft
Bib Fan kp o bac dI-
❑Pa.eent s
r
p
C3
o❑
❑ — )
c.ae.d M.e R tM d oarrvery
z o
�� P°e7merk
Fi "a
C3
❑—SignatureRwp*W s
❑ 40a-3�me rtss"&Ced Oe6very
❑Aduk PA**W $
B �0�
3r
C3
a° $0.49
[`
C3
C3
v
/21/2{115/
Total Poarago sin elF�r� g4
7f5.
jS
�
$ $3.94
r
{iD�
_
Mark Carter
I o3
2311 Interstate 30
�
Bryant, AR 72202
t�.tit7r�rm:��r_mr��e�-rw�. ��..s,�.:�--�.�..:_.:....x.n•a..�ri��a..•��u.,.e.�
9906 W. Baseline Road
Domestic
rU
For d0very information.
visit our website
at jy�V�VUSpS,CCM4
RACK+ AR 72209
MLITTLE
Ln
ru
QIMEell MMI Fea
$3.45
S
Icm & revs "*:—*b= f.o
❑ Kamm RoWM S-dooDiA 6
Oo
❑ I -cow ( s
Post nark
z o
❑ CeN6.d Mal Pa*kted DWKwy _
C3
❑Aduk PA**W $
❑Ad- NWOU a R.efi6.led UdN.y S
[`
C3
Posta,"
$0.49
v
12/21 /2)5
Fetal Postage anti Fee"
$ $3.94
,
Ln
- Letitia and John Huggler
7— p4
0
9906 W. Baseline Road
--
r`
Little Rock, AR 72009
James, Donna
From:
Floriani, Vince
Sent:
Wednesday, January 6, 2016 11:15 AM
To:
'Headley, Mark'
Cc:
Henry, Bill; Banihatti, Nat; James, Donna
Subject:
RE: Huffstutlar Property @ Baseline Rd and Childers Dr
Mark,
The applicant's engineer chose to not prepare a plan to show what you requested or address your questions.
With that being the case, CLR staff did agree to condition approval of the proposed development application and the
driveway locations contingent on the developer obtaining a permit from AHTD for the driveways. If AHTD denies the
driveway locations, the item may be required to return to the CLR Planning Commission for a 2nd approval or if the
change is not major, staff may approve the change.
Thanks for your help with this item. I apologize for not getting this response to you earlier.
I am looking forward to obtaining your response on the Mills High School later today.
Thanks again,
Vince Floriani, P.E.
Little Rock Public Works -Civil Engineering
701 W. Markham St.
Little Rock, Arkansas 72201
501-371-4817
From: Headley, Mark [mailto:Mark.Headley@ahtd.ar.gov]
Sent: Wednesday, January 06, 2016 9:22 AM
To: Floriani, Vince
Cc: Henry, Bill
Subject: RE: Huffstutlar Property @ Baseline Rd and Childers Dr
Vince,
Any progress on obtaining this requested information so we can proceed with our review of the
proposal?
Mark Headley, P.E.
District 6 Engineer
From: Headley, Mark
Sent: Wednesday, December 16, 2015 5:11 PM
To: Floriani, Vince (VFloriani(—alittlerock.org)
Cc: 'bhenry@littlerock.org'
Subject: FW: Huffstutlar Property @ Baseline Rd and Childers Dr
Vince,
Our designers noted the following:
The consultant needs to submit a layout of the frontage that shows the exact location of
the proposed drive and the distance it is located from projected gore of the 1-30 on
ramp before the Department can provide comments. Based on the proposed site layout
and parking accommodations it is assumed the trip generation is not
significant. However, the consultant should provide a short description of the site
impact to frontage road traffic operations.
Mark Headley, P.E.
District 6 Engineer
From: Headley, Mark
Sent: Monday, December 14, 2015 4:48 PM
To: Smith, Trinity D.
Cc: Phillips, Eric; Ivy, Daniel E.
Subject: FW: Huffstutlar Property @ Baseline Rd and Childers Dr
Based on the recent decision in Benton, this access drive on the frontage road near the entrance
ramp to I-30 may be fine. However, please review the attached layout for the aces on the
frontage road and Baseline and advise whether it is acceptable. Thanks!
Mark Headley, P.E.
District 6 Engineer
From: Ivy, Daniel E.
Sent: Friday, December 11, 2015 2:42 PM
To: Floriani, Vince
Cc: Headley, Mark
Subject: RE: Huffstutlar Property @ Baseline Rd and Childers Dr
Vince
The driveway on the frontage road is very close to the westbound on ramp. We may send this to Traffic for review, Mark
or myself will contact you next week.
Dan
From: Floriani, Vince [mailto:VFloriani littlerock.or ]
Sent: Thursday, December 10, 2015 4:59 PM
To: Ivy, Daniel E.
Subject: FW: Huffstutlar Property @ Baseline Rd and Childers Dr
Mr. Ivy,
Have you had an opportunity to look at this email?
Thanks,
Vince Floriani, P.E.
Little Rock Public Works -Civil Engineering
701 W. Markham St.
2
Little Rock, Arkansas 72201
501-371-4817
From: Floriani, Vince
Sent: Monday, December 07, 2015 10:39 AM
To: Ivy, Daniel E. (Dan iel.Iyy aCa� htd.ar.gov)
Subject: Huffstutlar Property @ Baseline Rd and Childers Dr
Mr. Ivy,
Will AHTD permit the widening of Baseline Rd adjacent to the property shown on the attachment. CLR requests an
additional 1.5 lanes (about 29.5 ft from centerline) to be provided with curb and gutter and sidewalk. The widening will
provide a right turn lane for now and half of a future 5 lane section when Baseline Rd is widened in the future.
In addition, the plan shows 2 driveways (1-30 and Baseline Rd). Will AHTD permit those 2 driveways in the locations and
widths as shown.
An answer by noon on Wednesday, December 9 is appreciated.
Thanks for your help,
Vince Floriani, P.E.
Little Rock Public Works -Civil Engineering
701 W. Markham St.
Little Rock, Arkansas 72201
501-371-4817
James, Donna
From: Floriani, Vince
Sent: Thursday, December 17, 2015 8:23 AM
To: MCGETRICK MCGETRICK <mcgetrick2@sbcglobal.net> (mcgetrick2@sbcglobal.net)
Cc: James, Donna
Subject: FW: Huffstutlar Property @ Baseline Rd and Childers Dr
Attachments: HufstuttlerPropBaselineRd .pdf, Hufstuttler Property.docx
CLR staff will follow the lead of AHTD and recommend approval based on their findings and permitting. I do not suspect
a decision will be made before January Planning Commission meeting.
Vince Floriani, P.E.
Little Rock Public Works -Civil Engineering
701 W. Markham St.
Little Rock, Arkansas 72201
501-371-4817
From: Headley, Mark [mailto:Mark.Headley@ahtd.ar.gov]
Sent: Wednesday, December 16, 2015 5:11 PM
To: Floriani, Vince
Cc: Henry, Bill
Subject: FW: Huffstutlar Property @ Baseline Rd and Childers Dr
Vince,
Our designers noted the following:
The consultant needs to submit a layout of the frontage that shows the exact location of
the proposed drive and the distance it is located from projected gore of the 1-30 on
ramp before the Department can provide comments. Based on the proposed site layout
and parking accommodations it is assumed the trip generation is not
significant. However, the consultant should provide a short description of the site
impact to frontage road traffic operations.
Mark Headley, P.E.
District 6 Engineer
From: Headley, Mark
Sent: Monday, December 14, 2015 4:48 PM
To: Smith, Trinity D.
Cc: Phillips, Eric; Ivy, Daniel E.
Subject: FW: Huffstutlar Property @ Baseline Rd and Childers Dr
Based on the recent decision in Benton, this access drive on the frontage road near the entrance
ramp to I-30 may be fine. However, please review the attached layout for the aces on the
frontage road and Baseline and advise whether it is acceptable. Thanks!
1
Mark Headley, P.E.
District 6 Engineer
From: Ivy, Daniel E.
Sent: Friday, December 11, 2015 2:42 PM
To: Floriani, Vince
Cc: Headley, Mark
Subject: RE: Huffstutlar Property @ Baseline Rd and Childers Dr
Vince
The driveway on the frontage road is very close to the westbound on ramp. We may send this to Traffic for review, Mark
or myself will contact you next week.
Dan
From: Floriani, Vince [ma !Ito:VFloriani littlerock.or ]
Sent: Thursday, December 10, 2015 4:59 PM
To: Ivy, Daniel E.
Subject: FW: Huffstutlar Property @ Baseline Rd and Childers Dr
Mr. Ivy,
Have you had an opportunity to look at this email?
Thanks,
Vince Floriani, P.E.
Little Rock Public Works -Civil Engineering
701 W. Markham St.
Little Rock, Arkansas 72201
501-371-4817
From: Floriani, Vince
Sent: Monday, December 07, 2015 10:39 AM
To: Ivy, Daniel E. (Daniel.Iv ahtd.ar. ov)
Subject: Huffstutlar Property @ Baseline Rd and Childers Dr
Mr. Ivy,
Will AHTD permit the widening of Baseline Rd adjacent to the property shown on the attachment. CLR requests an
additional 1.5 lanes (about 29.5 ft from centerline) to be provided with curb and gutter and sidewalk. The widening will
provide a right turn lane for now and half of a future 5 lane section when Baseline Rd is widened in the future.
In addition, the plan shows 2 driveways (1-30 and Baseline Rd). Will AHTD permit those 2 driveways in the locations and
widths as shown.
An answer by noon on Wednesday, December 9 is appreciated.
Thanks for your help,
Vince Floriani, P.E.
Little Rock Public Works -Civil Engineering
701 W. Markham St.
Little Rock, Arkansas 72201
501-371-4817
McGetrick & McGetrick, Inc.
Civil Engineering
December 12, 2015
Donna James, Subdivision Administrator
City of Little Rock, Arkansas
Planning and Development
723 West Markham
Little Rock, AR 72201-1334
Re: Response to Huffstutlar Property Z -4635-C
Dear Ms. James:
In regards to the staff comments from the Subdivision Committee hearing we have the following
responses.
Planning Staff Comments
Days of operation are Monday through Saturday 6:00a.m. to 7:00p.m.
The dumpster location is shown on the plan.
The hours of operation pick-up will be between 7:00a.m. and 6:00p.m. Monday through Saturday.
Machinery will be repaired on-site primarily inside the building. There will be outdoor salvage
of parts and repairs located on the site.
Signage will be a pylon sign as shown on the plan and will meet City requirements. There will be a
building sign also meeting City requirements facing the access road.
Outdoor equipment will be displayed in the gravel area shown along the access road. All other areas will
be paved.
The property will be fenced with a six foot black chain link fence around the entire boundary with a
barbed wire top.
The building will be a metal building with a metal roof. We will submit a rendering of the front as
quickly as I receive it.
The building height will be a maximum of 35 feet with only one story.
Public Works Comments
We would ask for a variance on the driveway locations. The one on the access road is the only location
we can place a drive with Highway Department approval due to the location of the on-ramp. We have
ask for a variance for the width of the drive off of the access road due to the large equipment hauled in
on trailers.
11419 Stagecoach )goad
Little Rock, AR 72210
501455-8899
501-455-0525
mcgetrick2@sbcglobal.net
McGetrick & McGetrick, Inc.
Civil Engineering
Landscape Comments
We have shown on the plan, areas that will have mature trees remaining and have natural vegetation.
This is approximately 60% of the site. We would ask for a variance to allow us to only have a 30 foot
landscape area along the access road.
If you have any questions regarding the information provided, please feel free to contact me.
Sincerely,
McG ick &McGetrick, Inc.
Patrick M. McGetrick, P.E.
PM:cmc
11419 Stagecoach Road
Little Rock, AR 72210
501455-8899
501-455-0525
mcgetrick2@sbcglobal.net
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
DATE: November 24, 2015
Entergy
Center Point - ARKLA
:AT & T
Central Arkansas Water
Little Rock Wastewater
Pulaski County Planning
Little Rock Fire Department
NAME: Huffstutlar Property Long -form PCD
TYPE OF ISSUE: Planned Commercial Development — New
Construction — Equipment Sales
FILE NUMBER: Z -4635-C
LOCATION: 10600 I-30
Public Works: Engineering, Traffic (2)
Parks and Recreation Department
Planning and Development — Site Plan Review
Planning and Development Graphics
Planning and Development — Building Codes
CATA
TO WHO IT MAY CONCERN:
On January 7, 2016 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on December 4, 201.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on December 9. 2015.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or recommendations
will be appreciated.
Sincerely,
Donna James, AICP
Subdivision Administrator
(Please respond below and return this letter with your comments for our records.)
Approved as Submitted.
PLEASE RETURN COMMENTS BY December 7 2015.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the easement
or the request will not be included in the Planning Commission agenda.
Comments:
Enclosure
Little Rock wastewater Comments
Project Number S -1150-B
Project Name Project Type Comment Made
CALS Subdivision Replat Replat 4 lots Sewer Available to this site. Sewer Easement Must be
retained in alley.
Project Number S -1502-A
Project Name
Project Type
Comment Made
Kathleen Inmon
Prelim Plat
Sewer Available to this site.
Prelim/Final Plat
Project Number S-1764
Project Name
Project Type
Comment Made
PCSSD Dixon Road
Remove, remodel, and construct new
Outside Service Boundary - No Comment.
Replacement High School
buildings
Project Number S-1765
Project Name
Project Type
Comment Made
Heritage Place
Preliminary Plat
Outside Service Boundary- No Comment.
Project Number S-1766
Project Name
Project Type
Comment Made
Village at the Gateway
Prelim Plat - Townhouses
Sewer main extension required with easements if new
Townhouse Community
sewer service is required for this project.
Project Number S-1767
Project Name Project Type Comment Made
Vincent View Preliminary Plat Sewer main extension required with easements if new
sewer service is required for this project.
Project Number S -641-M
Project Name Project Type
Markham West Shopping New Construction Commercial
Center
Project Number Z -2496-A
Project Name Project Type
Fletcher Library PD -0 Planned Development - Office
Comment Made
Sewer Available. Sewer Main Relocation Required to
construct project as shown.
Comment Made
Sewer Available to this site.
Thursday, December 03, 2015 Page 1 of 2
Project Number Z -3726-B
Project Name Project Type Comment Made
Packett House PD -C Planned Development - Commercial Grease Trap Review Required. Sewer main does not
appear to be on site. Need Construction Plans if new
sewer service is required.
Project Number Z -4635-C
Project Name Project Type
HufFstutlar Property PD -C Planned Development Commercial
Project Number Z -6526-C
Project Name Project Type
Parker Lexus PD -C Planned Development Commercial
Project Number Z -7626-B
Project Name Project Type
Joe T. Robinson PD -0 Planned Development Office
Project Number Z -8095-A
Project Name
Project Type
Garden Home Addition PD -I
Planned Development Industrial
Project Number Z -8605-B
Project Name
Project Type
SRVC on Kanis PD -C
Planned Development Commercial
Project Number Z-9097
Project Name
Project Type
O'Reilly Auto Parts PD -C
Planned Development Commercial
Comment Made
Sewer main extension required with easements if new
sewer service is required for this project.
Comment Made
Sewer Available to this site. EAD Review Required.
Comment Made
Sewer Available to this site, but appears outside Service
Bdy.
Comment Made
Sewer Available to this site.
Comment Made
Sewer Available to this site.
Comment Made
Sewer Available to this site. Sewer Easement Must be
retained for existing main.
Thursday, December 03, 2015 Page 2 of 2
Memo
Rock Region
METRO
Rock Region METRO Planning and Subdivision Review
To: City of Little Rock Planning and Development, Monte Moore
From: Kathleen Lambert, Sr. Transit Planner
Date: November 30, 2015
Re: Subdivision Reviews January 7, 2-oi5 hearing
3-) Z -6526-C PCD- Parker Lexus Shackleford West
a) Location is currently served on Route 5 West Markham by Rock Region METRO. The
future service plans for this area are inclusive of the business along Shackleford Rd. to
serve employees getting to work. Maintaining pedestrian access is important. We
would also like to request curb cut consolidation for the Phase IV showroom. We would
like a clear area from the intersection, to allow the bus to make a right hand turn and
serve that location. Consolidating the curb cuts into one 36' wide cut would be
beneficial. The bus needs 3-3-o' after making the turn to pull over and stop.
2) S-3-765 Heritage Place Preliminary Plat
a) Location is currently served on express route 25 Pinnacle Mountain by Rock Region
METRO. We have no comments on this proposed development at this time.
3) S-3-764 Pulaski County Special School District
a) Location is not currently served by Rock Region METRO. School service is in our future
plans. The plans for the driveways as drawn do not illustrate drop-off areas for each
school building. Connecting sidewalks for drop-off areas are essential for ADA access,
parking area crossing and bus service. Please clarify how vehicle loading would be
facilitated for all essential site plan elements, ball -fields and buildings.
4) Z -8095-A Garden Home Addition -1800 E -17th St
a) Location is currently served on Boyce St at -17th on route 3-2 by Rock Region METRO.
The proposed lot and curb cut provides adequate space for bus operations.
5) Z -7626-B Joe T Robinson School, 21003.-21501 AR Hwy 10 -Cantrell Rd.
a) Location is currently served near express route 25 Pinnacle Mountain by Rock Region
METRO. The development indicates bus drop-off and loading area for each school
building and site plan element. Sidewalk access is indicated from each drop-off area;
this will allow for future bus service. The turning radius on the drop-off forthe proposed
Freshman Academy building should be min 45.5' outside for a 40' bus. Please verify bus
access radii.
6) 5-3.767 Vincent View- Beckenham Drive
a) Location is currently served on express route 25 Pinnacle Mountain by Rock Region
METRO. We have no comments on this proposed development at this time.
7) Z -2496-A Fletcher Library- 823 North Buchanan St.
a) Location is currently served on route 8 Rodney Parnham by Rock region METRO. The
plan as shown indicated two curb cut closures and sidewalk additions which will
improve stop options at this location. We have no objections to the plan.
8) Z -86o5 -B SRVC on Kanis- 3.3.063. Kanis Rd.
a) Location is currently served on route 5, West Markham by Rock Region METRO. We
feel the one element missing from the plan is a pedestrian path through the parking
area from the sidewalk to give access to the bus route for shopping and jobs. We would
request to consolidate curb cuts. We have no objections to the development proposal.
9) 5-3.766 Village at the Gateway Townhouse Community -12500 Vimy Ridge Road
a) Location is not currently served by Rock Region METRO. However future plans indicate
service via Flex -transit. We have no objections to the plans as drawn. The developer has
treated the street network with care by completing the streets without dead ends. The
pedestrian network is extensive; commendable.
3.o) Z -4635-C Huffstutlar Property- 3.06001-30
a) Location is served on routes 23 at Baseline Rd and Childers Dr. by Rock Region METRO.
The property as shown on the plan does not indicate pedestrian access from the bus
route to the business. The plan the perimeter is fenced. Would the owner/ developer
3
please clarify where pedestrian access would be located? We have no objections to the
proposal.
11) S -115o -B River Market District SWC President Clinton Ave.
a) Location is currently served on the METRO Streetcar line and Rock Region METRO bus,
multiple routes via the River City Travel Center. We have no objections to the plan as
shown.
12) Z-9097 O'Reilly Automotive- East Roosevelt Rd.
a) Location is served on routes 2 & 9 by Rock Region METRO. We have two concerns
regarding this plan. One, a through driveway between Roosevelt Rd. and 26th St.
encourages cut -through and speeding, detrimental for transit operations. Second the
sidewalk is located io feet behind the curb with a large grassy verge. The corner
crossing curb cuts should align with the existing sidewalk network. It is difficult to load
passengers and wheel chairs across a large verge, 3-5' wide provides an adequate clear
zone for pedestrians.
13) Z -3726-B Packett House -1404 Cantrell Road
a) Location is served on route 21, University Ave by Rock Region METRO. Provide a
pedestrian way from the sidewalk bus route to the entrance. We have no objections to
the plan as shown.
14) S-1764 Kathleen Inmon Asher Ave & Anna Street
a) Location is served on route 14 Rosedale Rock Region METRO. We have no objections to
the plan as shown.
To: Donna James Subdivision Administrator
From: Captain Tony Rhodes / Captain John Hogue: Fire Marshal
Comment for the following Locations:
S-1767
Maintain Access:
Fire Hydrants.
Date: December 4, 2015
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess
of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access
roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and replaces or
repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire department personnel
for emergency access. Emergency opening devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are
capable of being opened by means of forcible entry tools or when a key box containing the keys
to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and installed to comply
with requirements of ASTM F 2200.
One- or Two-Familv Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family
dwelling residential developments. Developments of one- or two-family dwellings where the number of
dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access
roads, and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or private fire apparatus
access road and al dwelling units are equipped throughout with an approved automatic
sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall not be increased
unless fire apparatus access roads will connect with future development, as determined by
the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
Z -7626-B
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
Z -8095-A
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
S-1764
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
Z -6526-C
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
i�oading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section 13102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments— 2 means of access. - Maintain fire apparatus access roads
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30
feet or three stories in height shall have at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross
building area of more than 62,000 square feet shall be provide with two separate and approved fire
apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a
distance apart equal to not less than one half of the length of the maximum overall diagonal dimension
of the lot or area to be served, measured in a straight line between accesses.
30' Tali Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D105.1— D105.4
D105.1 Where Required. Where the vertical distance between the grade plane and the highest
roof surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes
of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched
roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
13105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of
26', exclusive of shoulders, in the immediate vicinity of the building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting this condition
shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the building on which the aerial fire
apparatus access road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire
apparatus access road or between the aerial fire apparatus road and the building. Other obstructions
shall be permitted to be places with the approval of the fire code official.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess
of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access
roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and replaces or
repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire department personnel
for emergency access. Emergency opening devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are
capable of being opened by means of forcible entry tools or when a key box containing the keys
to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and installed to comply
with requirements of ASTM F 2200.
Multi-Familv Residential Developments
As per Appendix D, Section D106.1 of the 2012 Arkansas Fire Prevention Code Vol. 1. Projects having
more than 100 dwelling units. Multiple -family residential projects having more than 100 dwelling units
shall be equipped throughout with two separate and approved fire apparatus access roads.
Exception: Projects having up to 200 dwelling units may have a single approved fire apparatus
access road when all building, including nonresidential occupancies are equipped throughout with
approved automatic sprinkler systems installed in accordance with Section 903.3.1.1 or 903.3.1.2
As per Appendix D, Section D106.2 of the 2012 Arkansas Fire prevention Code Vol. 1. Projects having
more than 200 dwelling units. Multiple -family residential projects having more than 200 dwelling units
shall be provided with two separate and approved fire apparatus access roads regardless of whether
they are equipped with an approved automatic sprinkler system.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
Z -2496-A
No Comments
Z -5608-B
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access
roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and replaces or
repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire department personnel
for emergency access. Emergency opening devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are
capable of being opened by means of forcible entry tools or when a key box containing the keys
to the lock is installed at the gate location.
Locking device specifications shall be submitted for approval \by the fire code official
Electric gate operators, where provided, shall be listed in accordance with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and installed to comply
with requirements of ASTM F 2200.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
S-1766
Maintain Access:
Fire Hvdrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol -
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
f-oading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D105.1— D105.4
D105.1 Where Required. Where the vertical distance between the grade plane and the highest
roof surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes
of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched
roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of
26', exclusive of shoulders, in the immediate vicinity of the building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting this condition
shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the building on which the aerial fire
apparatus access road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire
apparatus access road or between the aerial fire apparatus road and the building. Other obstructions
shall be permitted to be places with the approval of the fire code official.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess
of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access
roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and replaces or
repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire department personnel
for emergency access. Emergency opening devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are
capable of being opened by means of forcible entry tools or when a key box containing the keys
to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
Gates, intended for automatic operation shall be designed, constructed and installed to comply
with requirements of ASTM F 2200.
Multi -Family Residential Developments
As per Appendix D, Section D106.1 of the 2012 Arkansas Fire Prevention Code Vol. 1. Projects having
more than 100 dwelling units. Multiple -family residential projects having more than 100 dwelling units
shall be equipped throughout with two separate and approved fire apparatus access roads.
Exception: Projects having up to 200 dwelling units may have a single approved fire apparatus
access road when all building, including nonresidential occupancies are equipped throughout with
approved automatic sprinkler systems installed in accordance with Section 903.3.1.1 or 903.3.1.2
As per Appendix D, Section D106.2 of the 2012 Arkansas Fire prevention Code Vol. 1. Projects having
more than 200 dwelling units. Multiple -family residential projects having more than 200 dwelling units
shall be provided with two separate and approved fire apparatus access roads regardless of whether
they are equipped with an approved automatic sprinkler system.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
5-641-M
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol -
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
Loadin
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus byway of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30
feet or three stories in height shall have at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross
building area of more than 62,000 square feet shall be provide with two separate and approved fire
apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a
distance apart equal to not less than one half of the length of the maximum overall diagonal dimension
of the lot or area to be served, measured in a straight line between accesses.
30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D105.1— D105.4
D105.1 Where Required. Where the vertical distance between the grade plane and the highest
roof surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes
of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched
roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of
26', exclusive of shoulders, in the immediate vicinity of the building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting this condition
shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the building on which the aerial fire
apparatus access road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire
apparatus access road or between the aerial fire apparatus road and the building. Other obstructions
shall be permitted to be places with the approval of the fire code official.
nonri Fnric_
Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess
of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access
roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and replaces or
repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire department personnel
for emergency access. Emergency opening devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are
capable of being opened by means of forcible entry tools or when a key box containing the keys
to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and installed to comply
with requirements of ASTM F 2200.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
Z -4635-C
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30
feet or three stories in height shall have at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross
building area of more than 62,000 square feet shall be provide with two separate and approved fire
apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a
distance apart equal to not less than one half of the length of the maximum overall diagonal dimension
of the lot or area to be served, measured in a straight line between accesses.
30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D105.1— D105.4
D105.1 Where Required. Where the vertical distance between the grade plane and the highest
roof surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes
of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched
roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of
26', exclusive of shoulders, in the immediate vicinity of the building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting this condition
shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the building on which the aerial fire
apparatus access road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire
apparatus access road or between the aerial fire apparatus road and the building. Other obstructions
shall be permitted to be places with the approval of the fire code official.
Dead Fnds-
Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess
of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access
roads shall comply with all of the following criteria:
I. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and replaces or
repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire department personnel
for emergency access. Emergency opening devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are
capable of being opened by means of forcible entry tools or when a key box containing the keys
to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and installed to comply
with requirements of ASTM F 2200.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
S -1150-B
No Comment
Z-9097
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess
of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
Z -3726-B
Full plan review
S-1764
No Comment
S-1765
Maintain Access:
Fire Hydrants,
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
Regards, Captain Rhodes and Captain Hogue
Office: 918-3710
Ak
'`Entei
November 30, 2015
City of Little Rock
Department of Planning and Development
ATTN: Ms. Donna James, AICP
723 West Markham Street
Little Rock, AR 72201-1334
Entergy Arkansas Inc.
#9 Entergy Court
Little Rock, AR 72211
RE: Entergy comments related to Planning and Zoning items for the January 7" Meeting
Ms. James,
Please find below Entergy's comments related to the items received from the Department of Planning
and Development last week. The request letter said to have the comments back to you by December
7th, 2015.
• Parker Lexus — NWC Shackelford & Shackelford West Blvd: Z -6526-C
Entergy does not object to this proposal. A three phase power line exists along the west
side of South Shackelford Road and along the north side of Shackelford West Blvd up to
approximately the western boundary of Phase I at this location. There do not appear to
be any conflicts with existing Entergy facilities although care should be used in installing
the pylon sign at the corner of Shackelford and Shackelford West as overhead power
lines are in the vicinity. Contact Entergy in advance regarding future service
requirements to the development and future facilities locations as this project proceeds.
A distribution line will need to be extended to serve the site.
• Heritage Place Prelim Plat— 7510 Hwy 300: S-1765
Entergy does not object to this proposal. A three phase power line exists along the east
side of Hwy 300 at this location. There do not appear to be any conflicts with existing
Entergy facilities. These lines should not impact the platting of these lots. Contact
Entergy in advance regarding future service requirements to the development and future
facilities locations as this project proceeds.
• Pulaski County Spec. School District Subdiv Site plan — 925 E Dixon Rd: S-1764
Entergy does not object to this proposal. Three phase power line exists around and
throughout the existing property. Some of them appear to be in conflict with future plans
and will need to be adjusted and/or relocated to accommodate those plans. Relocation
costs may be incurred for facilities adjustments. Contact Entergy well in advance to
discuss future service requirements, new facilities locations and adjustments to existing
facilities as this project proceeds.
+ Garden Home Addition Revised Short Form —1800 East 17' St.: Z -8095-A
Entergy does not object to this proposal. There are no conflicts with existing Entergy
facilities as there are no electrical lines along the western edge of this property. Contact
Entergy should the service requirements or location of electrical service facilities change
due to this proposal.
Joe T Robinson School — 21001 — 21501 AR St Hwy 10: Z -7626-B
Entergy does not object to this proposal. Three phase power line exists around and
throughout the existing property. Some of them may be in conflict with future plans and
will need to be adjusted and/or relocated to accommodate those plans. Relocation costs
may be incurred for facilities adjustments. Contact Entergy well in advance to discuss
future service requirements, new facilities locations and adjustments to existing facilities
as this project proceeds.
Vincent View Prelim Plat — So of Pebble Beach & West of Garrett Glen Subdiv: S-1767
Entergy does not object to this proposal. A single phase, underground power line
currently extends along the north side of Beckenham Dr to the beginning of this platted
area, but there are no other Entergy facilities in the area which are in conflict with the
proposal. Contact Entergy in advance regarding future service requirements to the
development, desired line extensions, and future facilities locations as this project
proceeds.
Fletcher Library — 823 N Buchanan St: Z -2496-A
Entergy does not object to this proposal. Electrical service is already being provided to
the existing structure. Service can be provided to the new proposed community meeting
space on the property from an existing power line located across H Street. Contact
Entergy in advance regarding future service requirements to the development, desired
line extensions, and future facilities locations as this project proceeds.
SRVC on Kanis —11601 Kanis Rd: Z -8605-B
Entergy does not object to this proposal. A single phase power line exists along the west
side of this proposed development. There do not appear to be any conflicts with existing
Entergy facilities. Contact Entergy in advance regarding future service requirements to
the development, desired line extensions, and future facilities locations as this project
proceeds.
Village at the Gateway Townhouse Community —12500 Vimy Ridge Rd: S-1766
Entergy does not object to this proposal. A three phase power line exists along Vimy
Ridge Road to the east of this proposed development. There do not appear to be any
conflicts with existing Entergy facilities. Contact Entergy in advance regarding future
service requirements to the development and future facilities locations as this project
proceeds. Note that Entergy does require subdivision lots to be served by power lines
located along the front property lines of the development.
Markham West Shopping Center Subdiv site plan —11414 W Markham St: S -641-M
Entergy does not object to this proposal. Electrical service is already provided to the
existing building from the north side of the property. There do not appear to be any
conflicts with existing Entergy facilities. Contact Entergy in advance if electrical service
needs change as a result of the demolition and construction of a new building. As a
minimum, a disconnection from the existing service will be required as work progresses.
Huffstutlar Property —10600 I-30: Z -4635-C
Entergy does not object to this proposal. A three phase power line exists along the north
side of the frontage road on the south side of this proposed development. A single phase
line extends a short distance up the eastern boundary. There do not appear to be any
conflicts with existing Entergy facilities. Contact Entergy in advance regarding future
service requirements to the development and future facilities locations as this project
proceeds. Care should be used in installing the limestone equipment display if it is near
the overhead power lines on the front of the property.
CAL's Subdiv Replat — River Market Dist— SWC Pres Clinton Ave & Rock: 5-1150-B
Entergy does not object to this proposal. A three phase, underground power line exists
along the east -west access easement as described on the subdivision replat drawing.
These facilities must remain accessible 24 hours a day for maintenance and future
upgrades as required.
O'Reilly Automotive Store — E Roosevelt btwn Rock and Commerce: Z-9097
Entergy does not object to this proposal. A three phase power line exists along the south
side of the property along 26th Street. Street lights and associated secondary wires exist
along the front of the property on Roosevelt. There do not appear to be any conflicts with
existing Entergy facilities. Contact Entergy in advance regarding future service
requirements to the development and future facilities locations as this project proceeds.
• Packett House —1404 Cantrell Rd.: Z -3726-B
Entergy does not object to this proposal. Electrical service is already provided to the
existing building. There do not appear to be any conflicts with existing Entergy facilities.
However, care should be exercised when performing any work near the overhead and
underground power lines along Cantrell Road. Contact Entergy in advance if electrical
service needs change as a result of the building's use after rezoning.
• Kathleen Inmon Prelim/Final Plat — NWC Asher and Anna St: 5-1764
Entergy does not object to this proposal. Electrical service is already provided to the
existing buildings from the north side of the property. There do not appear to be any
conflicts with existing Entergy facilities. Contact Entergy in advance if electrical service
needs change as a result of this replat.
If you need further assistance you may call me at 501-954-5158 or e-mail me at
bneumei@entergy.com.
Sincerely,
,q-q�r�a � c�rr�Ze L
Bernard Neumeier
Region Engineering Supervisor
Entergy Arkansas, Inc.
MEMORANDUM
TO: DONNA JAMES, SUBDIVISION ADMINISTRATOR
FROM: TRACY SPILLMAN, PLANS DEVELOPMENT ADMINISTRATOR
SUBJECT: REVIEW OF THE BUFFER AND LANDSCAPE REQUIREMENTS OF
THE DECEMBER 09, 2015, SUBDIVISION COMMITTEE MEETING
CC: DANA CARNEY, ZONING & SUBDIVISION MANAGER
DATE: DECEMBER 04, 2015
1. River Market District— SWC President Clinton Avenue and Rock Street S -1150-B
No Comments
2. 5300 — 5304 Asher Avenue S -1502-A.
No Comments
3. 7510 HWY 300 S-1765
No Comments
4. 12500 Vimy Ridge Road (S-1766
No Comments
5. South of Pebble Beach Estates and West of Garrett Glen Subdivision S-1767
No Comments
6. 11414 West Markham Street (S -641-M)
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30)
linear feet of perimeter planting strip.
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). For
developments with more than one hundred fifty (15 0) parking spaces the minimum size
of an interior landscape area shall be three hundred (300) square feet. Interior islands
must be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in
the interior landscape areas at the rate of one (1) tree for every twelve (12) parking
spaces.
Building landscape areas shall be provided between the vehicular use area used for public
parking and the general vicinity of the building. These shall be provided at the rate
equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree
and four (4) shrubs shall be planted in the building landscape areas for each forty (40)
linear feet of vehicular use area abutting the building.
An irrigation system shall be required for developments of one (1) acre or larger.
For developments of less than one (1) acre a there shall be a water source within seventy-
five (75) feet of the plants to be irrigated.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
7. 925 East Dixon Road S-17.64)
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30)
linear feet of perimeter planting strip.
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). For
developments with more than one hundred fifty (15 0) parking spaces the minimum size
of an interior landscape area shall be three hundred (300) square feet. Interior islands
must be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in
the interior landscape areas at the rate of one (1) tree for every twelve (12) parking
spaces.
Building landscape areas shall be provided between the vehicular use area used for public
parking and the general vicinity of the building. These shall be provided at the rate
equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree
and four (4) shrubs shall be planted in the building landscape areas for each forty (40)
linear feet of vehicular use area abutting the building.
An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
8. 823 North Buchanan (Z -2496-A
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements and the Hillcrest Overlay District.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30)
linear feet of perimeter planting strip.
Trees and shrubs are required to be placed between the proposed building and the "H"
Street right-of-way. Plant material is to be provided at the rate of one (1) tree and three
(3) shrubs for every 30 linear feet.
The southwest properties are zoned R-3. As a component of all land use buffer
requirements, opaque screening, whether a fence or other device, a minimum of six (6)
feet in height shall be required along these perimeters of the site.
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The minimum
size of an interior landscape area shall be one hundred fifty (150) square feet for
developments with one hundred fifty (150) or fewer parking spaces. Interior islands must
be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in the
interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces.
An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
9. 1404 Cantrell Road (Z -3726-B)
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
If building rehabilitation exceeds fifty percent (50%) of the replacement cost then the
landscaping and buffer must also come into compliancy accordingly.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
10. 10600I-30 (Z -4635-C)
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half ('/2) the full width requirement but in no case less
than nine (9) feet. The maximum dimension required shall be fifty (50) feet.
A minimum fifty (50) foot street buffer will be required along the I-30 Frontage Road
and Baseline Road.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30)
linear feet of perimeter planting strip. -
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The minimum
size of an interior landscape area shall be one hundred fifty (150) square feet for
developments with one hundred fifty (15 0) or fewer parking spaces. Interior islands must
be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in the
interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces.
Building landscape areas shall be provided between the vehicular use area used for public
parking and the general vicinity of the building. These shall be provided at the rate
equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree
and four (4) shrubs shall be planted in the building landscape areas for each forty (40)
linear feet of vehicular use area abutting the building.
An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
11. 12208 West Markham Z -5258-F
No Comments
12. Southwest corner of Kirby and Kanis Roads (Z -5503-E
No Comments
13. NWC Shackleford Road and Shackleford West -(Z-6526-C
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30)
linear feet of perimeter planting strip.
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The minimum
size of an interior landscape area shall be one hundred fifty (150) square feet for
developments with one hundred fifty (15 0) or fewer parking spaces. Interior islands must
be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in the
interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces.
Building landscape areas shall be provided between the vehicular use area used for public
parking and the general vicinity of the building. These shall be provided at the rate
equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree
and four (4) shrubs shall be planted in the building landscape areas for each forty (40)
linear feet of vehicular use area abutting the building.
An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
14. 21001 - 21501 Arkansas State HWY 10 (Z -7626-B
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). For
developments with more than one hundred fifty (15 0) parking spaces the minimum size
of an interior landscape area shall be three hundred (300) square feet. Interior islands
must be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in
the interior landscape areas at the rate of one (1) tree for every twelve (12) parking
spaces.
An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
15. 1800 East 17th Street Z -8095-A
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half ('/2) the full width requirement but in no case less
than nine (9) feet. The property is located in the City's designated mature area. A twenty-
five (25%) percent reduction of the buffer requirements is acceptable. The minimum
dimension of the buffer shall be six (6) feet nine (9) inches. A street buffer is not
provided adjacent to Boyce Street and the proposed parking area. A variance will be
required from the City Beautiful Commission.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
16. Rawls PCD Z -8193-B
No Comments
17. 11601 Kanis Road (Z -8605-B)
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half (%Z) the full width requirement but in no case less
than nine (9) feet. The maximum dimension required shall be fifty (50) feet.
Trees and shrubs are required planed adjacent to street right-of-way. Plant material is to
be provided at 1 tree and 3 shrubs for every 30 linear feet. Existing trees and vegetation
can be used to satisfy landscape requirements. A fifty (50) foot street buffer will be
required along Kanis Road.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30)
linear feet of perimeter planting strip.
An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
18. East Roosevelt Road between Rock Street and Commerce Street (Z-9097)
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
Trees and shrubs are required to be placed between the proposed building and the
Roosevelt Road, Commerce Street and 26h Street right-of-ways. Plant material is to be
provided at the rate of one (1) tree and three (3) shrubs for every 30 linear feet.
One (1) tree and four (4) shrubs shall be will be required for each forty (40) linear feet of
vehicular use area provided between the vehicular use area used for public parking and
the general vicinity of the building.
Trees shall be included in the interior landscape areas at the rate of one (1) tree for every
twelve (12) parking spaces.
An irrigation system shall be required for developments of one (1) acre or larger.
For developments of less than one (1) acre a there shall be a water source within seventy-
five (75) feet of the plants to be irrigated.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
PLANNING COMMISSION REVIEW
CENTRAL ARKANSAS WATER
07 January 2016
NAME TYPE ISSUE COMMENTS
PARKER LEXUS SHACKLEFORD Z -6526-C All Central Arkansas Water requirements in
WEST LONG effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
Z-9097 East Roosevelt Road between Rock Street and Commerce Street
Project is subject to full commercial plan review and approval prior to issuance of a building permit. For
information on submittal requirements and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichev@littlerock.oM or
Mark Alderfer at 501.371.4875; malderfer@littlerock.00rrg.
Z -3726-B 1404 Cantrell Road
Due to change in occupancy the facility must comply with all 2012 Arkansas Fire Prevention Codes.
Contact Building Codes for an on-site inspection to review conditions and requirements.
Curtis Richey at 501.371.4724; crichev@Iittlerock. or or
Mark Alderfer at 501.371.4875; malderfer@littlerock.or.
S-1764 S -1502A
No Comment
Regards, Curtis Richey
Commercial Plans Examiner
NAME TYPE ISSUE
COMMENTS
PULASKI COUNTY SPECIAL S-1764
All Central Arkansas Water requirements in
SCHOOL DISTRICT SPECIAL
effect at the time of request for water service
SCHOOL DISTRICT
must be met.
SUBDIVISION SITE PLAN
REVIEW
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
3
NAME
TYPEISSUE
HERITAGE PLACE PRELIMINARY S-1765
PLAT
COMMENTS
discuss backflow prevention requirements
for this project.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
A water main extension will be needed to
provide water service to this property.
Please submit plans for water facilities to
Central Arkansas Water for review. Plan
revisions may be required after additional
review. Contact Central Arkansas Water
regarding procedures for installation of water
facilities. Approval of plans by Central
Arkansas Water, the Arkansas Department
of Health Engineering Division and Little
Rock Fire Department is required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to
obtain information regarding the required
placement of the hydrant(s) and contact
Central Arkansas Water regarding
procedures for installation of the hydrant(s).
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges.
2
NAME TYPE ISSUE COMMENTS
GARDEN HOUSE ADDITION Z -8095-A All Central Arkansas Water requirements in
REVISED SHORT -FORM PD -I effect at the time of request for water service
must be met.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
F
NAME TYPE ISSUE COMMENTS
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
NAME TYPE ISSUE
JOE T ROBINSON SCHOOL Z -7626-B
REVISED LONG -FORM POD
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
NAME TYPE ISSUE COMMENTS
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
0
NAME
FLETCHER LIBRARY SHORT -
FORM PD -0
TYPE ISSUE _ COMMENTS
Z -2496-A All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
NAME
VINCENT VIEW PRELIMINARY
PLAT
TYPE ISSUE COMMENTS
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
S-1767 All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Please submit plans for water facilities to
Central Arkansas Water for review. Plan
revisions may be required after additional
review. Contact Central Arkansas Water
regarding procedures for installation of water
facilities. Approval of plans by Central
Arkansas Water, the Arkansas Department
of Health Engineering Division and Little
Rock Fire Department is required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to
obtain information regarding the required
placement of the hydrant(s) and contact
Central Arkansas Water regarding
procedures for installation of the hydrant(s)
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges.
t -J
NAME TYPE ISSUE ^� COMMENTS
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
VILLAGE AT THE GATE WAY S-1766 All Central Arkansas Water requirements in
TOWNHOUSE COMMUNITY effect at the time of request for water service
PRELIMINARY PLAT must be met.
Please submit plans for water facilities to
Central Arkansas Water for review. Plan
revisions may be required after additional
review. Contact Central Arkansas Water
regarding procedures for installation of water
facilities. Approval of plans by Central
Arkansas Water, the Arkansas Department
of Health Engineering Division and Little
Rock Fire Department is required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to
obtain information regarding the required
placement of the hydrant(s) and contact
Central Arkansas Water regarding
procedures for installation of the hydrant(s).
11
NAME
TYPE ISSUE COMMENTS
SRVC ON KANIS SHORT -FORM Z -8605-B All Central Arkansas Water requirements in
PD -C effect at the time of request for water service
must be met.
A water main extension will be needed to
provide water service to this property.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
10
NAME TYPE ISSUE COMMENTS
pressure zone backflow preventer shall be
required.
13
NAME TYPEISSUE
MARKHAM WEST SHOPPING S-641 -M
CENTER SUBDIVISION SITE
PLAN REVIEW
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (R PZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
12
NAME TYPE ISSUE COMMENTS
of Customer Owned Line Agreement is
required.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required
CAL'S SUBDIVISION REPLAT S-1 150-B NO OBJECTIONS; All Central Arkansas
Water requirements in effect at the time of
request for water service must be met.
O'RILLY AUTOMOTIVE STORE Z-9097 All Central Arkansas Water requirements in
SHORT -FORM PD -C effect at the time of request for water service
must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
15
NAME
HUFFSTUTLAR PROPERTY
LONG -FORM PCD
TYPE ISSUE COMMENTS
Z -4635-C All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
14
To: Dana Carney, Zoning & Subdivision Manager Date: 12-08-15
Donna James, Zoning
Monte Moore, Subdivision
From: Curtis Richey / Mark Alderfer: Building Codes
Building Code Comments:
Z -6526-C NWC Shackleford road and Shackle€ord Road West Blvd.
Project is subject to full commercial plan review and approval prior to issuance of a building permit. For
information on submittal requirements and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; criche littlerock.or or
Mark Alderfer at 501.371.4875; malderfer littlerock.or .
S-1765 7510 Hwy 300
No Comment
S-1764 925 East Dixon Road
Project is subject to full commercial plan review and approval prior to issuance of a building permit. For
information on submittal requirements and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; criche littlerock.orcr or
Mark Alderfer at 501.371.4875; malderfer@littlerock.org.
Z -8095-A 1800 East 171" Street
No Comment
Z -7626-B 21001-2101 Arkansas State Hwy 10
Project is subject to full commercial plan review and approval prior to issuance of a building permit. For
information on submittal requirements and the review process, contact a commercial plans examiner:
Project may require separation of building occupancies and/or ambulatory care requirements to be met.
Curtis Richey at 501.371.4724; crichey@littlerock.oEg or
Mark Alderfer at 501.371.4875; malderfer@tittlerock.org.
Fire Review for access is required.
S-1767 South of Pebble Beach Estates and West of Garrett Glenn Subdivision
No Comment by Building codes
Fire Review for access is required.
NAME TYPE ISSUE COMMENTS
PACKETT HOUSE PD -C Z -3726-B All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on-site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
Fire sprinkler systems which do not contain
additives such as antifreeze shall be isolated
with a double detector check valve
assembly. If additives are used, a reduced
pressure zone backflow preventer shall be
required.
LATHLEEN INMON S -1502-A NO OBJECTIONS; All Central Arkansas
PRELIMINARY/FINAL PLAT Water requirements in effect at the time of
request for water service must be met.
16
Z -2496-A 823 North Buchanan Street
Project is subject to full commercial plan review and approval prior to issuance of a building permit. For
information on submittal requirements and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichey@littlerock.org or
Mark Alderfer at 501.371.4875; malderfer@llttlerock.org.
Z -8605-B 11601 Kanis Road
Project is subject to full commercial plan review and approval prior to issuance of a building permit. For
information on submittal requirements and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichev@iittlerock.org or
Mark Alderfer at 501.371.4875; malderfer littlerock.or .
S-1766 12500 Vim Ride Road
Fire Separation of Townhouses must comply with 2012 Arkansas Fire Protection Code.
Club and Pool
Project is subject to full commercial plan review and approval prior to issuance of a building permit. For
information on submittal requirements and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichev@little rock.or9 or
Mark Alderfer at 501.371.4875; malderfer@littlerock.org.
Fire Marshall Review for Access is required. Property should be accessed from the West as well as access
shown from the east.
S -641-M 11414 West Markham Street
Project is subject to full commercial plan review and approval prior to issuance of a building permit. For
information on submittal requirements and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichev@littlerock.orp, or
Mark Alderfer at 501.371.4875; malderfer@littlerock.ore.
Z -4635-C 106001-30
Project is subject to full commercial plan review and approval prior to issuance of a building permit. For
information on submittal requirements and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichev@littlerock.org or
Mark Alderfer at 501.371.4875; maiderfer@litt;erock.org.
S -1150-B River Market District -SWC President Clinton Avenue and Rock
No Comment
Public Works Review Comments
Planning Commission Board of Adjustment
Agenda Date: 1-7-16
Z File Number 5-1150-B
CAL's Subdivision Replat SWC Pres Clinton Ave & Rock St.
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
Z File Number S -1502-A
Kathleen Inmon Pre/Final Plat
5300 Asher Ave
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
2 Per PAGIS the Anna Street ROW has been abandoned.
Z File Number 5-1764
PCSSD Subdivision Site Plan Review 925 E Dixon Rd
1 Dixon Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45
feet from centerline will be required.
2 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
3 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
4 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
5 With site development, provide design of street conforming to the Master Street Plan. Provide
widening sufficient for construction of a left turn lane with sufficient stack and tapers to comply with
AASHTO standards. AHTD is being contacted about the permitting the construction of a center left
turn lane.
6 All new driveways shall be constructed with concrete aprons per City Ordinance.
7 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
8 Street Improvement plans shall include signage and striping. Public Works must approve completed
plans prior to construction.
9 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. The driveways should be located at least 150 ft from the side property lines.
Variances must be requested for these driveway locations.
10 Submit a Traffic Impact Study for the proposed project. Study should address trip generation and trip
distribution for the development and also should take into account existing and projected traffic
growth. The study should include the on-site traffic and circulation plan with vehicle stack and
delays. The study should be provided to staff by December 16, 2015.
Monday, December 07, 2015 Page I of 10
2 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to these streets including 5 -foot sidewalks with planned development.
The proposed back of curb should be located 29.5 ft from centerline. If a permit is pulled prior to the
bidding of the CLR Kanis Rd project, the applicant will be responsible to construct the widening to
Kanis Rd. If so, a payment in -lieu of construction should be made to CLR.
3 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction. Is a variance
requested to advance grade the future grooming facilty with construction of the proposed vet clinic?
4 All driveways shall be concrete aprons per City Ordinance.
5 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
6 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
7 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
8 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. The current driveway location will cause vehicle waiting to make left turns into
the site to block the Autumn Rd/Kanis Rd intersection. The subject property must share a driveway
access with the property to the east. The width of the driveway must not exceed 36 ft. The CLR
Kanis Rd Project will construct 1 driveway at the property line for both properties to share.
9 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
Z File Number Z-9097
O'Reilly Automotive Store PD -C Roosevelt Rd at Rock Street
1 Roosevelt Rd is classified on the Master Street Plan as a principal arterial with special design
standards. Dedication of right-of-way to 35 feet from centerline will be required.
2 A 20 feet radial dedication of right-of-way is required at the intersection of Roosevelt Rd and
Commerce St.
3 A 20 feet radial dedication of right-of-way is required at the intersection of Commerce St and 26th St.
4 A 20 feet radial dedication of right-of-way is required at the intersection of Rock St. and 26th St.
5 A 20 feet radial dedication of right-of-way is required at the intersection of Roosevelt Rd and Rock St.
6 Sidewalks with appropriate handicap ramps are required in accordance with Sec. 31-175 of the Little
Rock Code and the Master Street Plan adjacent to all boundary streets.
7 All driveways shall be concrete aprons per City Ordinance.
8 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
9 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI.
Monday, December 07, 2015 Page 9 of 10
12 Traffic calming devices are required for long straight streets to discourage speeding. Traffic circles or
round -a -bouts are suggested at regular intervals and at main intersections. Contact Travis Herbner,
Traffic Eng. At 379-1805 for additional info.
13 Due to the # of proposed lots accessing Francis Ave from this property and the property to the west,
Francis Ave should be constructed to a residential collector standard of 31 ft wide.
14 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the
intersection(s) comply with 2004 AASHTO Green Book standards.
15 No residential waste collection service will be provided on private streets unless the property owners
association provides a waiver of damage claims for operations on private property. All street radiuses
both public and private must be sufficient for access by a collection truck for collection service to be
provided.
16 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
17 Vegetation must be established on disturbed area within 21 days of completion of harvest activities.
18 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
19 Provide detail of each lot layout showing structure and driveway.
20 Will the pedestrian paths behind homes be within tract land or easement?
Z File Number 5-1767
Vincent View Pre Plat Beckenham DrIve
1 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction. Is the applicant
requesting an advanced grading permit to grade the lots or beyond the lots at the time the ROW and
easements are graded?
2 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
3 Storm water detention ordinance applies to this property.
4 Show the proposed unobstructed access to the detention pond.
5 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
6 With site development, provide design of street conforming to the Master Street Plan. Construct
street improvement to this street including 5 -foot sidewalks with planned development.
7 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
8 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Greg Simmons) for more info.
9 All public drainage easements must be unobstructed and access provided to the public right-of-way by
constructed infrastructure and/or documented on the final plat.
Monday, December 07, 2015 Page 3 of 10
Monday, December 07, 2015 Page 7 of 10
Z File Number Z -3726-B
Packett House PD -C 1404 Cantrell Rd
1 Cantrell Rd is classified on the Master Street Plan as a principal arterial with special design
standards. Dedication of right-of-way to 45 feet from centerline will be required.
2 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
3 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI.
4 The west driveway should be restriped as one-way exit only.
Z File Number Z -4635-C
Huffstutlar Property PCD 106001-30
1 Baseline Rd is classified on the Master Street Plan as a principal arterial. Dedication of right-of-way
to 55 feet from centerline will be required.
2 A 20 feet radial dedication of right-of-way is required at the intersection of Baseline Rd and Childers
Drive.
3 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Childers Drive including 5 -foot sidewalks with planned development.
The new back of curb should be 18 ft from centerline.
4 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Baseline Rd including 5 -foot sidewalks with planned development.
The new back of curb should be located 29.5 ft from centerline. AHTD is being contacted for permit
approval. If denied, a payment in -lieu of construction will be required.
5 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI.
6 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction. Will the entire
property being graded with construction of the development?
7 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
8 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. The proposed driveway on Baseline Rd is proposed to be located 40 ft from the
side property line. CLR code requires a driveway on Baseline Rd to be located at least 150 ft from
the side property line. A variance must be requested for the driveway location.
9 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. The driveway is proposed to be located 60 ft from the side property line. CLR
code requires driveways on the I-30 to be at least 125 ft from the side property line. A variance must
be requested for the driveway location.
10 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. The proposed driveway on Baseline Rd is proposed to be located 40 ft from the
side property line. CLR code requires a driveway to be located at least 150 ft from the side property
line. A variance must be requested for the driveway location.
Monday, December 07, 2015 Page 5 of 10
I 1 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Greg Simmons) for more info.
12 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. The I-30 driveway is proposed to be located 60 ft from the side property line.
Driveways on the I-30 to be at least 125 ft from the side property line. A variance must be requested
for the driveway location.
13 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
14 No right-of-way dedication or radial right-of-way dedication is required adjacent to I-30
15 Access to detention ponds must be provided to the public right-of-way and/or access easement for
future maintenance by the developer and/or local property owners' association.
Z File Number Z -5258-F
Service King Rev PCD
0 No Comments
Z File Number Z -5503-E
Panther Branch Lot 2 Rev PD -R, Add. Sign
0 No comments
Z File Number Z -6526-C
Parker Lexus Shackleford West PCD
12208 W. Markham St.
SW corner Kanis & Cooper Orbit Rd
NWC Shackleford Rd & Shackleford West
1 Kanis Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45
feet from centerline will be required.
2 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction. An advanced
grading pemit is being requested.
3 Per Sec. 29-197(5), an undisturbed of at least 80 ft wide should be maintained adjacent to Kanis Rd.
An undisturbed buffer of at least 50 ft should be maintained adjacent to private properties on the
north, east, and west where advance grading is being requested.
Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
5 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
6 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
7 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
8 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the
intersection(s) comply with 2004 AASHTO Green Book standards.
Monday, December 07, 2015 Page 6 of 10
9 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
10 Prior to construction of retaining walls, a engineer's certification of design and plans must be
submitted to Public Works for approval. After construction, an as -built certification is required for
construction of the retaining wall.
11 Retaining walls designed to exceed 15 ft in height are required to seek a variance for construction.
Provide proposed wall elevations.
12 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Kanis Rd including 5 -foot sidewalks with planned development. The
new back of curb should be placed 29.5 ft from centerline. The Kanis Rd Street Widening project is
expected to begin in the spring of 2016.
13 Show the Kanis Rd driveway location.
14 Per Sec. 29-197(2), the grading shall be expeditously completed in a time frame not to exceed one
(1) year in duration from the time work commences to installation of all
final erosion control
measures and vegetation.
15 Per Sec. 29-197(11), a permanent vegetative cover of suitable perennial grass shall be established
over all disturbed areas. Where indicated by soil tests, pH adjustments and
addition of
fertilizer
may be required.
16 Per Sec. 29-197(12), all erosion and stabilization controls, including permanent vegetation and
plantings and stormwater detention systems are to be
maintained by the responsible part for
a period of 2 years following completion of site grading.
17 Per Sec. 29-197(12), periodic mowing, generally 2 times per year or more often if required by CLR
shall be provided to encourage perennial grass growth.
18 Per Sec. 29-197(13), maintenance for the 2 year period shall be guaranteed through posting of cash,
surety bond or letter of credit as referenced in Sec. 31-431(2)
at the time of final inspection
of the
grading activities.
19 Per Sec. 29-197(14), all required federal, state, and local permits and approvals shall be obtained prior
to commencement of land alteration activities.
20 Staked orange fencing must be installed along the open space undisturbed buffer areas during
construction to prevent access to these buffer areas.
21 Access to detention ponds must be provided to the public right-of-way and/or access easement for
future maintenance by the developer and/or local property owners' association.
22 Visual screening of the completed area can be accomplished by provided undisturbed buffer strips or
earthen berms. Per Sec. 29-197(3) provide line of sight illustrations from adjacent
street(s) and
properties
Z File Number Z -7626-B
Joe T. Robinson School Rev POD
for review by the Planning Commission.
21001 - 21501 Ark Hwy 10
1 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan. Maintenance of the detention pond and all private drainage
improvements is the responsibility of the developer and/or local property owners' association and
detailed in the bill of assurance.
10 100 year overflow swales must be constructed and placed within public drainage easements.
11 Access to detention ponds must be provided to the public right-of-way and/or access easement for
future maintenance by the developer and/or local property owners' association.
Z File Number 5-641-M
Markham West Shopping Center Subdivision Site 11414 W. Markham St.
I Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
2 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
3 Pedestrian access is suggested to be provided to within the development from the W. Markham St
sidewalk.
Z File Number Z -2496-A
Fletcher Library PD -O 823 N. Buchanan St.
1 Due to the proposed use of the property, the Master Street Plan specifies that Buchanan Street for the
frontage of this property must meet commercial street standards. Dedicate right-of-way to 30 feet from
centerline.
2 Due to the proposed use of the property, the Master Street Plan specifies that G Street for the frontage
of this property must meet commercial street standards. Dedicate right-of-way to 30 feet from
centerline.
3 A 20 feet radial dedication of right-of-way is required at the intersection of Buchanan St. and H St.
4 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to G St. including 5 -foot sidewalks with planned development.
5 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
6 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan. Maintenance of the detention pond and all private drainage
improvements is the responsibility of the developer and/or local property owners' association and
detailed in the bill of assurance.
7 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
Per Sec. 29-102 an evaluation should be conducted on the basis of existing downstream development
and any analysis of stormwater runoff with and without the proposed development. If the proposed
development will cause or increase downstream flooding conditions, provisions to minimize such
flooding conditions should be included in the design of the stormwater management improvements.
Such provisions may include downstream improvements and/or detention of stormwater runoff and it
regulated discharge to the downstream storm drainage system.
9 Additional traffic is being added to G St which is 10 ft wide.
10 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
Monday, December 07, 2015 Page 4 of 10
2 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Hwy 10 including 5 -foot sidewalks with planned development.
AHTD denied permitting the street improvements.
3 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI.
4 Submit a Trak Impact Study for the proposed project. Study should address trip generation and trip
distribution for the development, the onsite traffic plan and also should take into account existing and
projected traffic growth. The study should be submitted by December 16, 2015 for this item to
remain on the current agenda.
5 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
6 On site striping and signage plans should be forwarded to Public Works, Traffic Engineering for
approval with the site development package.
7 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. A driveway variance must be requested for the width of driveway to exceed 36 feet.
Z File Number Z -8095-A
Garden Home Addition Rev PD -I 1800 E. 17th St.
1 Due to the proposed use of the property, the Master Street Plan specifies that Boyce St. Street for the
frontage of this property must meet commercial street standards. Dedicate right-of-way to 30 feet from
centerline.
2 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Fletcher St. adjacent to lot 2 with planned development.
3 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan. Maintenance of the detention pond and all private drainage
improvements is the responsibility of the developer and/or local property owners' association and
detailed in the bill of assurance.
4 A 20 feet radial dedication of right-of-way is required at the intersection of Fletcher St. and E. 17th St.
5 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
6 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
7 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Greg Simmons) for more info.
8 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
Z File Plumber Z -8605-B
SRVC on Kanis PD -C 11601 Kanis Rd
1 Kanis Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45
feet from centerline will be required.
Monday, December 07, 2015 Page 8 of 10
11 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
Z File Number S-1765
Heritage Place Preliminary Plat 7510 Hwy 300
1 Hwy 300 is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45
feet from centerline will be required.
2 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Hwy 300 including 5 -foot sidewalks with planned development.
AHTD denied street improvements to be made to Hwy 300.
3 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI.
4 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the
intersection of Hwy 300 and the access easement comply with 2004 AASHTO Green Book standards.
Z File Number 5-1766
Village at Gateway Townhouse Community Pre Plat 12500 Vimy Ridge Rd
1 Vimy Ridge Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of-
way 45 feet from centerline will be required.
2 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction. A variance is being
requested to advance grade the entire property with construction of Phase 1.
3 Storm water detention ordinance applies to this property. Maintenance of the detention pond and all
private drainage improvements is the responsibility of the developer and/or local property owners'
association and detailed in the bill of assurance.
4 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
5 All public drainage easements must be unobstructed and access provided to the public right-of-way by
constructed infrastructure and/or documented on the final plat.
6 All public drainage easements must contain drainage infrastructure approved by the City of Little
Rock Public Works Department.
7 100 year overflow swales must be constructed and placed within public drainage easements.
8 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Vimy Ridge Rd including 5 -foot sidewalks with planned
development. The new back of curb should be located 29.5 ft from centerline. What is the proposed
phased construction plan?
9 The downstream property at 12423 Vimy Ridge Rd has been flooded in the past from this
development. The construction of the project should consider this downstream condition.
10 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Greg Simmons) for more info.
11 Street names and street naming conventions must be approved by Public Works. York Drive and
Gateway Drive are already used. Contact Glenn Haley at (501) 371-4537 for more information.
Monday, December 07, 2015 Page 2 of 10
10 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to 26th St including 5 -foot sidewalks with planned development. The
new back of curb should be located 15.5 ft from centerline.
11 The proposed access ramps at the intersections do not comply with City standards. The ramps direct
pedestrians into the center of the intersections. The ramps on Roosevelt Rd should be type 3 ramps
and direct pedestrians east and west. The ramps on the north side of 26th St. should be type 2 ramps
and direct pedestrians to the north -south and the east -west.
12 The bottom of the proposed sign must be at an elevation high enough to not obstruct the sight
distance.
13 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
Monday, December 07, 2015 Page 10 of 10