HomeMy WebLinkAboutZ-4565-B Staff AnalysisFILE NO.: Z -4565-B
NAME: Lot 2 Kanis/Shackleford Subdivision Short -form PCD
LOCATION: Located West of Kaufman Road in the 10700 Block of Kanis Road
EVELOPER:
Kana Hotel Group — Alpesh Patel
308 North Peters Road, Suite 110
Knoxville, TN 37922
FNC;INFFR-
White-Daters and Associates
24 Rahling Circle
Little Rock, AR 72223
AREA: 1.6 acres
CURRENT ZONING
ALLOWED USES
NUMBER OF LOTS: 1
0-3, General Office District
General Office
PROPOSED ZONING: PCD
PROPOSED USE: Hotel
VARIAN CESNVAIVERS REQU
A. PROPOSALIREQUEST:
TED: None requested.
FT. NEW STREET: 0 LF
The developers are proposing a rezoning of this 1.63 acre lot from 0-3, General
Office District to PCD to allow construction of a new hotel. Fairfield Inn and Suite
Hotel which is a division of Marriot Hotels is proposing a three story 80 room
facility just east of the intersection of Kanis and South Shackleford Roads. The
hotel is proposed with a covered canopy facing to the west and a two story
parking deck adjacent to Kanis Road. With the two story deck and parking to the
south of the canopy, the total parking provided is 94 parking spaces which
exceeds the City requirement.
Access will be from the existing private driveway off Kanis Road. The northern
driveway will access the lower parking deck. The southern driveway will access
the upper parking deck and the hotel entrance. Patrons will go to the hotel
FILE NO.: Z-4565-8 {Cont.
C
entrance for check in and then proceed to the parking deck. This will eliminate
cars that would stop to turn left into the lower parking deck. An additional access
point will be the common access easement that extends out to South
Shackleford Road across the existing bank parking lot. This will add circulation
within the hotel development and also provide two access points for emergency
vehicles.
The development is proposing the placement of two (2) signs. A pylon sign is
proposed on Kanis Road at the driveway entrance. The sign is proposed
thirty-six (36) feet high and one hundred and sixty (160) square feet in area. The
request includes the option of an electronic reader board sign. The second sign
is proposed within a sign easement located on the adjacent lot near South
Shackleford Road. The sign is proposed with a maximum height of six (6) feet
and a maximum sign area of sixty-four (64) square feet.
EXISTING CONDITIONS:
Kanis Road adjacent to the site has been constructed to Master Street Plan
standard. The sidewalk is in place along the property frontage. The site is tree
covered with a single-family residence located to the east of the site fronting
Kaufman Road. There are other single-family homes located along Kaufman
Road. There are a number of zoning classifications within the area. This site is
zoned 0-3, General Office District as is the Bancorp South Bank property. The
property to the west, Mamma Bea's Big Burger is zoned 0-2, Office and
Institutional District as is property located to the south, fronting South
Shackleford Road, containing hotels, restaurant uses and the Heart Hospital.
Across South Shackleford Road is property zoned PCD, 0-3, General Office
District, C-2, Shopping Center District and C-3, General Commercial District
which has developed with a number of uses including a convenience store,
hotels, automobile dealerships and general office uses. North of the site is a
large insurance company office complex, Arkansas Farm Bureau, and a daycare
facility, Kidco.
NEIGHBORHOOD COMMENTS:
As of this writing, staff has received a few informational phone calls from the area
property .owners. All property owners located within 200 -feet of the site, all
residents who could be identified located within 300 feet of the site and the John
Barrow Neighborhood Association were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Kanis Road is classified on the Master Street Plan as a minor arterial. A
dedication of right-of-way 45 feet from centerline will be required.
2
FILE Na.: Z -4565-B (Cont.
2. With site development, provide the design of the street conforming to the
Master Street Plan. An in -lieu contribution must be made for one half street
improvements on Kanis Road for future dual left turn lanes with the planned
development.
3. Sidewalks with appropriate handicap ramps are required along the 30 foot
common access easement in accordance with Section 31-175 of the Little
Rock Code and the Master Street Plan.
4. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
5. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other than
residential subdivisions, site grading and drainage plans must be submitted
and approved prior to the start of construction.
6. Stormwater detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan.
7. Provide proposed elevations for the top and bottom of the proposed retaining
wall. if wall height is greater than 15 feet a variance must be requested from
the Land Alteration Regulations.
8. Plans of all work in right-of-way shall be submitted for approval prior to start of
work. Obtain barricade permit prior to doing any work in the right-of-way from
Traffic Engineering at (501) 379-1805 (Travis Herbner).
9. If disturbed area is one (1) or more acres, obtain a NPDES storm water
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Existing private sewer main on the site must be relocated prior to
construction. Contact Little Rock Wastewater Utility for additional information.
Enter : No comment received.
Center -Point Enerav: No comment received
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. Additional fire hydrant(s) will
be required. Contact the Little Rock Fire Department to obtain information
regarding the required placement of the hydrant(s) and contact Central Arkansas
Water regarding procedures for installation of the hydrant(s). The facilities
on-site will be private. When meters are planned off private lines, private facilities
shall be installed to Central Arkansas Water's material and construction
specifications and installation will be inspected by an engineer, licensed to
3
FILE NO.: Z -4565-B (Cont.
practice in the State of Arkansas. Execution of Customer Owned Line
Agreement is required. Please submit plans for water facilities and/or fire
protection system to Central Arkansas Water for review. Plan revisions may be
required after additional review. Contact Central Arkansas Water regarding
procedures for installation of water facilities and/or fire service. Approval of plans
by the Arkansas Department of Health Engineering Division and Little Rock Fire
Department is required. Fire sprinkler systems which do not contain additives
such as antifreeze shall be isolated with a double detector check valve assembly.
If additives are used, a reduced pressure zone backflow preventer shall be
required.
Fire Department: Drive canopy must be constructed with a 13 '/2 foot clearance.
Install fire hydrants per code. Contact the Little Rock Fire Department for
additional information.
County Planning: No comment.
CATA: The site is located on CATA Bus Route #3 the Baptist Medical Center
Route.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division: This request is located in the 1-430 Planning District. The
Land Use Plan shows Office for this property. The applicant has applied for a
rezoning for a PCD.
Because this PCD request is for a hotel, which is considered an office use, the
request does not require a change to the Land Use Plan.
Master Street Plan: Kanis Road is a Minor Arterial. A Minor Arterial provides
connections to and through an urban area and their primary function is to provide
short distance travel within the urbanized area. Entrances and exits should be
limited to minimize negative effects of traffic and pedestrians on Kanis Road
since it is a Minor Arterial. This street may require dedication of right-of-way and
may require street improvements for entrances and exits to the site.
Bicycle Plan: There are no bike routes in this. immediate vicinity.
Neiahborhood Action Plan: This area is covered by the John Barrow
Neighborhood Action Plan. Their Business and Commercial Goal states:
"enhance the climate directed towards encouraging new businesses and
commercial establishments to located in the area as well as retention of existing
businesses."
0
FILE NO.: Z -4565-B Cont.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements.
2. The zoning buffer ordinance requires a fifteen foot (15') wide land use buffer
along the eastern property line. The property to the east is being used as
single family residential. Seventy percent (70%) of these buffers are to
remain undisturbed.
3. The landscape ordinance requires a minimum of eight percent (8%) of the
paved surface areas to be allocated as green space. These islands are to be
evenly distributed throughout the site.
4. The property to the east is residential; therefore, a six (6) foot high opaque
screen, either a wooden fence with its face side directed outward, a wall, or
dense evergreen plantings, is required along the eastern perimeter of the site.
5. An automatic irrigation system to water landscaped areas will be required.
6. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this tree covered site. Credit toward fulfilling Landscape
Ordinance requirements can be given when preserving trees of six (6) inch
caliper or larger.
G. SUBDIVISION COMMITTEE COMMENT: (September 24, 2009)
Mr. Joe White was present representing the applicant. Staff presented an
overview of the request stating there were a few outstanding technical issues in
need of addressing prior to the item being forwarded to the Commission for final
action. Staff requested the site plan include details concerning the total height
and total area for the ground mounted signs indicated on the site plan.
Public Works comments were addressed. Staff stated Kanis Road was classified
on the Master Street Plan as a minor arterial which would required right of way
dedication and street construction per the Boundary Street Ordinance and
Master Street Plan. Staff also stated a grading permit would be required prior to
any clearing or grading on the site. Staff stated the stormwater detention
ordinance would apply to the future development of the site. Staff requested
Mr. White provide the location of the stormwater detention facilities on the plan.
Staff stated all plans for work in the right of way would require proper permits and
approval prior to the start of construction.
Landscaping comments were addressed. Staff stated screening was required
along the eastern perimeter of the site since the adjacent property was currently
being used as a residences. Staff stated the parking areas would require
landscaping per the City's Landscape Ordinance requirements. Staff also stated
at the time of development a small amount of building landscaping would be
required.
5
FILE NO.: Z -4565-B (Cont.
Staff noted comments from the other reporting departments and agencies
suggesting the applicant contact them individually for additional clarification.
There was no further discussion of the item. The Committee then forwarded the
item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised cover letter to staff addressing the issues
raised at the September 24, 2009, Subdivision Committee meeting. The
applicant has removed the request for building signage along the eastern and
southern facades.
The request is to allow the rezoning of this site from 0-3, General Office District
to PCD to allow the construction of a new hotel on the site. The hotel is
proposed with three stories and a maximum building height of 60 -feet. The site
plan indicates the placement of a two story parking deck with the first level at
grade with Kanis Road in front of the hotel.
The site plan indicates an existing utility easement located along the eastern
perimeter. The property to the east is zoned office but is currently being used as
a single-family home. The zoning buffer ordinance requires buffering and/or
screening for property zoned or used with a lesser intense use. Typically utility
easements cannot count as a part of the buffering requirement. For this site the
zoning buffer ordinance requires a fifteen foot (15) wide land use buffer along
the eastern property line. Seventy percent (70%) of the buffer is remain
undisturbed. The buffer area was previously cleared with the installation of the
sewer line located within the utility easement. Also the development will require
the placement of a retaining wall within the required buffer area. The request
includes the allowance of the utility easement as the required buffer. According
to the applicant the easement will be relocated and abandoned in the future but
most likely not at the time of development. The site plan indicates the
reestablishment of screening by the placement of an evergreen screen along the
eastern perimeter at the time of development. Staff is supportive of the
applicant's request.
Signs are proposed along Kanis Road and along Shackleford Road. The sign
proposed on Shackleford Road is located within a signage easement on the
adjacent bank lot. The signage along Kanis Road is proposed as a pylon sign as
typically allowed in the commercial zoning district or a maximum height of
thirty-six feet and a maximum sign area of one -hundred sixty square feet. The
signage proposed on Shackleford Road is proposed as typically allowed in office
zones or a maximum of six feet in height and sixty-four square feet in area. Staff
is not supportive of the pylon sign located on Kanis Road. The property is
currently zoned office. Staff feels signage complying with the office zoning
district is more appropriate for this area.
C
FILE NO.: Z-4565-6 Cont.)
The sign plan includes building signage at the third level along the northern and
western facades. The signage is proposed with a maximum of ten percent of the
facade area on which the sign is to be located. The signage along the western
fagade does not have public street frontage. Staff is supportive of allowing the
signage as proposed on the western facade. Staff feels the location of the hotel
and the visibility this additional signage will offer will eliminate the need for a
pylon sign along Kanis Road.
86 parking spaces are proposed within the parking deck and eight (8) surface
spaces are proposed for a total of 94 parking spaces. Hotel developments
typically require the placement of one parking space per guestroom, plus an
additional ten percent of the total of all parking spaces required for developments
larger than twenty rooms for employees and non -guest users patronizing meeting
rooms, restaurants and other facilities. The hotel is proposed with
80 guestrooms, no restaurant and a small meeting room. Based on the number
of rooms the ordinance would typically require the placement of 88 parking
spaces.
The site development composition includes a total of 43,500 square feet of
building (20.0%) and a 31,500 square foot two story parking deck (14.6%). The
area proposed with paving is 10,400 square feet (14.5%) and 31,224 square feet
(50.9%) is proposed as landscape area.
The dumpster hours of service have been limited to 7 am to 10 pm Monday
through Saturday. The applicant has indicated when the property to the east and
south are redeveloped and no longer used as residential the limits on the hours
of dumpster service be removed. Staff is supportive of the request.
Staff is generally supportive of the development as a hotel but staff is not
supportive of the signage plan as proposed. The area has developed with a
mixture of uses including a variety of retail uses, hotels, a hospital, an automobile
dealership and office uses. Staff feels the use of the property as a hotel is
appropriate but does not feel the placement of a 36 -foot tall 160-suqare foot in
area sign along Kanis Road is needed. The area on the east side of South
Shackleford Road is zoned and has developed with the general development
criteria of the office zoning district including signage. The underlying zoning of
this property is office as is the adjacent parcels. Staff feels a ground sign is
adequate to identify the business from customers traveling west bound on Kanis
Road and with the placement of the wall sign on the third level of the building
facing west this provide the desired visibility for customers entering from South
Shackleford Road.
STAFF RECOMMENDATION:
Staff recommends denial of the request as filed.
7
FILE NO.: Z -4565-B (Cont.
PLANNING COMMISSION ACTION: (OCTOBER 15, 2009)
The applicant was present. There were registered objectors present. Staff presented
the item stating the applicant had amended the request to limit the signage along Kanis
Road to a ground mounted monument sign with a maximum height of six (6) feet and a
maximum sign area of sixty-four (64) square feet as recommended by staff in the
agenda write-up. Staff stated to their knowledge there were no remaining outstanding
technical issues associated with the request. Staff stated they were now supportive of
the request and presented a recommendation of approval of the request subject to
compliance with the comment and conditions as outlined in paragraphs D, E and F of
the agenda staff report. Staff also presented a recommendation of approval of the
applicant's request to allow the placement of a wall sign on the western fagade as
presented on the site plan.
Mr. Joe White stated there were two issues raised by the adjoining property owner
which they desired to be read into the record. One was that all water would be directed
to the northwest and no water would drain across Ms. Pearson's property which was
located to the east. He stated the second was the adjoining property owners were filing
a Future Land Use Plan Amendment for several properties in the area. Mr. White
stated his client would support the neighbors in their efforts.
Mr. John McKay stated these two commitments addressed his and Ms. Parson's
concerns.
There was no further discussion of the item. The chair entertained a motion for
approval of the item as presented by staff and amended by the applicant. The motion
carried by a vote of 8 ayes, 0 noes and 3 absent.
E•
ITEM NO.: 6,
NAME: Lot 2 Kanis/Shackleford Subdivision Short -form PCD
Z -4565-B
LOCATION: located West of Kaufman Road in the 10700 Block of Kanis Road
Planning Staff Comments:
1. Provide notification of all property owners located within 200 -feet of the site,
complete with the certified abstract list, notice form with affidavit executed and proof
of mailing. The notice must be mailed no later than September 30, 2009. The Office
of Planning and Development must receive the proof of notice no later than October
9, 2009.
2. The site plan indicates the placement of signage on all four facades of the building.
Provide justification for allowance of signage on the facades without public street
frontage.
3. Provide details of the proposed ground sign. The commercial district of the zoning
ordinance would typically allow a maximum sign height of 36 feet and a maximum
sign area of 160 square feet. The office zone allows for a maximum sign height of 6
feet and a maximum sign area of 64 square feet. The property is currently zoned 0-
3.
4. The area to the south and east of the site is currently being used as residential
property. Provide the days and hours of dumpster service in the general notes
section of the site plan.
5. Provide the location of any proposed fencing on the site plan.
Variance/Waivers:
None requested.
Public Works Conditions:
2.
3.
4.
5.
Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication
of right-of-way 45 feet from centerline will be required. An additional 10 feet of right-
of-way, measured from the centerline of the right-of-way, for a future right turn lane
must be dedicated.
With site development, provide the design of the street conforming to the Master
Street Plan. An in -lieu contribution must be made for one half street improvements
on Kanis Road for future dual left turn lanes with the planned development.
Sidewalks with appropriate handicap ramps are required along the 30 foot common
access easement in accordance with Section 31-175 of the Little Rock Code and the
Master Street Plan.
Repair or replace any curb and gutter or sidewalk that is damaged in the public right-
of-way prior to occupancy.
A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction.
Storm water detention ordinance applies to this property. Show the proposed
Item # 6.
location for storm water detention facilities on the plan.
7. Provide proposed elevations for the top and bottom of the proposed retaining wall. If
wall height is greater than 15 feet a variance must be requested from the Land
Alteration Regulations.
8. Plans of all work in right-of-way shall be submitted for approval prior to start of work.
Obtain barricade permit prior to doing any work in the right-of-way from Traffic
Engineering at (501) 379-1805 (Travis Herbner).
9. If disturbed area is one (1) or more acres, obtain a NPDES storm water permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
Utilities and Fire Department/County Planning:
Wastewater: Existing private sewer main on the site must be relocated prior to
construction. Contact Little Rock Wastewater Utility for additional information.
Entergy: No comment received.
Center -Point Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at the
time of request for water service must be met. Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to obtain information regarding the required
placement of the hydrant(s) and contact Central Arkansas Water regarding procedures
for installation of the hydrant(s). The facilities on-site will be private. When meters are
planned off private lines, private facilities shall be installed to Central Arkansas Water's
material and construction specifications and installation will be inspected by an
engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned
Line Agreement is required. Please submit plans for water facilities and/or fire
protection system to Central Arkansas Water for review. Plan revisions may be
required after additional review. Contact Central Arkansas Water regarding procedures
for installation of water facilities and/or fire service. Approval of plans by the Arkansas
Department of Health Engineering Division and Little Rock Fire Department is required.
Fire sprinkler systems which do not contain additives such as antifreeze shall be
isolated with a double detector check valve assembly. If additives are used, a reduced
pressure zone backflow preventer shall be required.
Fire Department: Drive canopy must be constructed with a 13 1/2 foot clearance. Install
fire hydrants per code. Contact the Little Rock Fire Department for additional
information.
County Planning: No comment.
CATA: The site is located on CATA Bus Route #3 the Baptist Medical Center Route.
Planning Division: This request is located in the 1-430 Planning District. The Land Use
Plan shows Office for this property. The applicant has applied for a rezoning for a PCD.
Item # 6.
Because this PCD request is for a hotel, which is considered an office use, the request
does not require a change to the Land Use Plan.
Master Street Plan: Kanis Road is a Minor Arterial. A Minor Arterial provides
connections to and through an urban area and their primary function is to provide short
distance travel within the urbanized area. Entrances and exits should be limited to
minimize negative effects of traffic and pedestrians on Kanis Road since it is a Minor
Arterial. This street may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
Bicycle Plan: There are no bike routes in this immediate vicinity.
Neighborhood Action Plan: This area is covered by the John Barrow Neighborhood
Action Plan. Their Business and Commercial Goal states: "enhance the climate
directed towards encouraging new businesses and commercial establishments to
located in the area as well as retention of existing businesses."
Landscape:
1. Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
2. The zoning buffer ordinance requires a fifteen foot (16) wide land use buffer along
the eastern property line. The property to the east is being used as single family
residential. Seventy percent (70%) of these buffers are to remain undisturbed.
3. The landscape ordinance requires a minimum of eight percent (8%) of the paved
surface areas to be allocated as green space. These islands are to be evenly
distributed throughout the site.
4. The property to the east is residential; therefore, a six (6) foot high opaque screen,
either a wooden fence with its face side directed outward, a wall, or dense evergreen
plantings, is required along the eastern perimeter of the site.
5. An automatic irrigation system to water landscaped areas will be required.
6. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this tree covered site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or larger.
Revised plat/plan Submit four (4) copies of a revised preliminary plat/plan (to include
the additional information as noted above) to staff on Wednesday, September 30, 2009.
Item # 6.