HomeMy WebLinkAboutZ-4478-E Map 2STRUCTURAL NOTES A. GENERAL 1) DESIGNS OF ANTENNA, COAX -CABLE, EQUIPMENT INSTALLATIONS SHALL COMPLY WITH TIA/EIA-222-F-1996 STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWERS AND ANTENNA SUPPORT STRUCTURES. THE BASIC WIND SPEED FOR DESIGN IS 70 MPH. ICE THICKNESS IS 1/2 INCH. 2) THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS & EXISTING CONDITIONS AND NOTIFY THE OWNER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIALS OR PROCEEDING WITH CONSTRUCTION. ENGINEER/ ARCHITECT'S APPROVAL IS REQUIRED FOR ANY CHANGES TO THE DESIGN. 3) THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH OSHA SAFETY REQUIREMENTS. B. STEEL 1) STRUCTURAL STEEL FABRICATION, ERECTION AND CONNECTION DESIGN SHALL CONFORM TO THE LATEST EDITION OF THE AISC ASD SPECIFICATION. 2) STRUCTURAL STEEL PLATES AND SHAPES SHALL CONFORM TO ASTM A36. ALL STRUCTURAL STEEL PIPES SHALL CONFORM TO ASTM A53 GRADE B. ALL STRUCTURAL STEEL COMPONENTS AND FABRICATED ASSEMBLIES SHALL BE HOT DIP GALVANIZED AFTER FABRICATION. 3) ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA SUPPORT ASSEMBLIES SHALL CONFORM TO ASTM A307 OR ASTM A36, U.N.O. ALL EXPOSED FASTENERS, NUTS AND WASHERS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. CONCRETE EXPANSION ANCHORS SHALL BE HILTI KWIK BOLTS UNLESS OTHERWISE NOTED. 4) WELDING SHALL BE IN ACCORDANCE WITH AMERICAN WELDING SOCIETY (AWS) D.1.1-92. STRUCTURAL WELDING CODE -STEEL WELD ELECTRONICS SHALL BE E70XX. C. CONCRETE 1) ALL CONCRETE CONSTRUCTION SHALL BE PER ACI 318 AND ACI 301 LATEST EDITIONS. 2) ALL CONCRETE SHALL ATTAIN THE FOLLOWING 28 DAY COMPRESSIVE STRENGTHS OF MINIMUM 3,000 PSI. 3) REINFORCING STEEL SHALL CONFORM TO A615-GR60. 4) REINFORCEMENT PROTECTION TYPICAL U.N.O.: CONCRETE PLACED AGAINST EARTH 3" CONCRETE PLACED IN FORMS BUT EXPOSED TO WEATHER OR EARTH: (a) QRS #5 AND SMALLER 1 1/2" (b) BAPS-�LARGER THAN 5 2" 5) NO SPLICES OF REINFORCEMENT -PERMITTED EXCEPT AS DETAILED OR AUTHORIZED. DETAIL BARS IN ACCORDANCE, WITH "ACI DETAILING MANUAL - 19947, PUBLICATION SP -66 AND "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", ACI 318-95. D. FOUNDATION AND EARTHWORK 1) FOUNDATIONS ARE DESIGNED TO BEAR ON ENGINEERED FILL OR NATURA WITH A CAPACITY OF 2,000 PSF. THIS VALUE IS TO BE VERIFIED IN THE BY A QUALIFIED INSPECTOR OR TESTING AGENCY. 2) ALL EXCAVATION ON WHICH CONCRETE IS TO BE PLACED SHALL BE SUBSTANTIALLY HORIZONTAL OR UNDISTURBED AND UNFROZEN SOIL AND FREE FROM LOOSE MATERIAL AND EXCESS GROUNDWATER. DEWATERING EXCESS GROUNDWATER SHALL BE PROVIDED IF REQUIRED. 3) CONCRETE FOUNDATIONS SHALL NOT BE PLACED ON ORGANIC MATERIAL. SOUND SOIL IS NOT REACHED AT THE DESIGNATED EXCAVATION DEPTH. UNSATISFACTORY SOIL SHALL BE EXCAVATED TO ITS FULL DEPTH AND E REPLACED MECHANICALLY COMPACTED GRANULAR MATERIAL OR THE EXCAVATION BE FILLED WITH CONCRETE OF THE SAME QUALITY SPECIFIE THE FOUNDATION. - -8" CONCRETE SLAB W/ #4®12 O.C. EA WAY --8" #57 STONE OR CR -1 BROOM FINISH COMPACTED SOIL TO MIN. 95% MODIFIED MAX. DENSITY PER ASTM D1557 METHOD D) NOTE: CONTRACTOR TO VERIFY LOCAL CODES FOR REBAR AND CONCRETE AND TO VERIFY WITH TELECORP THIS INSTALLATION AS IT DIFFERS FROM LUCENT TECHNOLOGIES SPECIFICATIONS. FOUNDATION SECTION NOT TO SCALE FUTURE GROWTH CABINET L — — GROWTH CABINET PRIMARY RADIO CABINET POWER CABINET 2'-4" _! 2'-4" 2'-4"__� 11 131-0" NOTES: 1. CONCRETE FOR SLAB ON GRADE SHALL BE AIR ENTRAINED, fc' = 3000 PSI AT 28 DAYS. 2. ALL EXPOSED CONCRETE CORNERS SHALL HAVE A 3/4" CHAMFER, 3. REINFORCING BARS SHALL BE ASTM A615 GR 60. 4. MINIMUM CONCRETE COVER REINFORCING STEEL SHALL BE 2" IF CONCRETE IS PLACED IN FORM, 3" IF CONCRETE IS PLACED AGAINST EARTH. FOUNDATION PLAN NOT TO SCALE HILTI HIT C-100-, (OR [QUAL) 1/2"0 W/ 4 1/2" EMBED. MIN. (TYP. 4 PLACES) TS 3 1/2" OR - 3 1/2"0 STD PIPE PIPE, & BOLT PATTERN 3/16 - 8" x8" x3/8" ICE BRIDGE BASE PLATE DETAIL 3 NinT Tn crAI c S-1 10'-0" (TYP)------� A - C-2 GALVAN I Z E D PLATFORM W/ HANDRAIL GB #4 ICE BRIDGE SECTION NOT TO SCALE IVA GB #3 NOTE: 1. MONOPOLE AND PLATFORM ARE DESIGNED BY OTHERS. 2. SEE ELECTRICAL DRAWING FOR GROUNDING DETAILS. ANTENNA ORIENTATION � NOT TO SCALE ANTENNA -SEE SCHEDULE ON SHEET A-1. SEE ELEVATION ON SHT A-2 ANTENNA MOUNTING BRACKET DOWNTILT BRACKET ANTENNA MOUNT AND HANDRAIL 2 1/2"0 PIPE GALVANIZED - PIPE TO PIPE CLAMP SEE NOTE 1 SEE NOTE 2 PIPE INLET- GRATING MONOPOLE PORT ON MONOPOLE NOTES: 1. SECURE CABLES TO GRATING W/ TIE WRAPS 3'-0" O.0 2. PROVIDE KELLOMS GRIP AROUND CABLES AND FASTEN TO (E) J -HOOKS INSIDE MONOPOLE SECTION MICROFLECT - B509 PIPE HEAD f-- 0 .I NOT TO SCALE WIDE GALV GA BENT 11/16"0 HOLES F TO SUIT MICROFLECT 81190 HALFSTRAP W/ 1/4!'0 STAINLESS STEEL SCREW (OR EQUAL) MICROFLECT B1752 SNAP -IN HANGER BRACKET, BOLTED TO CHANNEL (12) 3/4" HOLES FOR SNAP -IN HANGERS COAX CABLE W/ SST SNAP -IN CABLE HANGER 5 O.D. PIPE LECT B130) ivv i E: ALL STEEL IS GALVANIZED. ALL BOLTS TO BE FURNISHED W/ WASHERS AND NUTS. ICE BRIDGE PIER r 3000 PSI CONCRETE PILE NOT TO SCALE TELECORP REALTY, LLC 900 S. SHACKLEFORD SUITE 600 LITTLE ROCK, AR 72211 OFFICE, (501) 312-2455 &Al GEM ENGINEERING COMPANY 10970 Stancliff Houston, Texas 77099-4206 Phone 281 561-9225 Fax 281 561-9399 PROJECT NO- LTR0188 DRAWN BY- GVS1 CHECKED BY- TAlHM SUBMITTALS (V. DESCRIPTION REV. FINAL - 1 _I 00 -_--__ - -8" CONCRETE SLAB W/ #4®12 O.C. EA WAY --8" #57 STONE OR CR -1 BROOM FINISH COMPACTED SOIL TO MIN. 95% MODIFIED MAX. DENSITY PER ASTM D1557 METHOD D) NOTE: CONTRACTOR TO VERIFY LOCAL CODES FOR REBAR AND CONCRETE AND TO VERIFY WITH TELECORP THIS INSTALLATION AS IT DIFFERS FROM LUCENT TECHNOLOGIES SPECIFICATIONS. FOUNDATION SECTION NOT TO SCALE FUTURE GROWTH CABINET L — — GROWTH CABINET PRIMARY RADIO CABINET POWER CABINET 2'-4" _! 2'-4" 2'-4"__� 11 131-0" NOTES: 1. CONCRETE FOR SLAB ON GRADE SHALL BE AIR ENTRAINED, fc' = 3000 PSI AT 28 DAYS. 2. ALL EXPOSED CONCRETE CORNERS SHALL HAVE A 3/4" CHAMFER, 3. REINFORCING BARS SHALL BE ASTM A615 GR 60. 4. MINIMUM CONCRETE COVER REINFORCING STEEL SHALL BE 2" IF CONCRETE IS PLACED IN FORM, 3" IF CONCRETE IS PLACED AGAINST EARTH. FOUNDATION PLAN NOT TO SCALE HILTI HIT C-100-, (OR [QUAL) 1/2"0 W/ 4 1/2" EMBED. MIN. (TYP. 4 PLACES) TS 3 1/2" OR - 3 1/2"0 STD PIPE PIPE, & BOLT PATTERN 3/16 - 8" x8" x3/8" ICE BRIDGE BASE PLATE DETAIL 3 NinT Tn crAI c S-1 10'-0" (TYP)------� A - C-2 GALVAN I Z E D PLATFORM W/ HANDRAIL GB #4 ICE BRIDGE SECTION NOT TO SCALE IVA GB #3 NOTE: 1. MONOPOLE AND PLATFORM ARE DESIGNED BY OTHERS. 2. SEE ELECTRICAL DRAWING FOR GROUNDING DETAILS. ANTENNA ORIENTATION � NOT TO SCALE ANTENNA -SEE SCHEDULE ON SHEET A-1. SEE ELEVATION ON SHT A-2 ANTENNA MOUNTING BRACKET DOWNTILT BRACKET ANTENNA MOUNT AND HANDRAIL 2 1/2"0 PIPE GALVANIZED - PIPE TO PIPE CLAMP SEE NOTE 1 SEE NOTE 2 PIPE INLET- GRATING MONOPOLE PORT ON MONOPOLE NOTES: 1. SECURE CABLES TO GRATING W/ TIE WRAPS 3'-0" O.0 2. PROVIDE KELLOMS GRIP AROUND CABLES AND FASTEN TO (E) J -HOOKS INSIDE MONOPOLE SECTION MICROFLECT - B509 PIPE HEAD f-- 0 .I NOT TO SCALE WIDE GALV GA BENT 11/16"0 HOLES F TO SUIT MICROFLECT 81190 HALFSTRAP W/ 1/4!'0 STAINLESS STEEL SCREW (OR EQUAL) MICROFLECT B1752 SNAP -IN HANGER BRACKET, BOLTED TO CHANNEL (12) 3/4" HOLES FOR SNAP -IN HANGERS COAX CABLE W/ SST SNAP -IN CABLE HANGER 5 O.D. PIPE LECT B130) ivv i E: ALL STEEL IS GALVANIZED. ALL BOLTS TO BE FURNISHED W/ WASHERS AND NUTS. ICE BRIDGE PIER r 3000 PSI CONCRETE PILE NOT TO SCALE TELECORP REALTY, LLC 900 S. SHACKLEFORD SUITE 600 LITTLE ROCK, AR 72211 OFFICE, (501) 312-2455 &Al GEM ENGINEERING COMPANY 10970 Stancliff Houston, Texas 77099-4206 Phone 281 561-9225 Fax 281 561-9399 PROJECT NO- LTR0188 DRAWN BY- GVS1 CHECKED BY- TAlHM SUBMITTALS DATE 101-27-991CONSTRUCTION DESCRIPTION REV. FINAL - 1 _I 1�P�Op A www f/,No. 6796 SCALE - 0 1/2 1 2 I - - I I I GRAPHIC SCALE IN INCHES LTRO16B MORRISON RD. TANK *16 13602 MORRISON RD. LITTLE ROCK ARKANSAS 72212 SHEET TITLE STRUCTURAL NOTE SECTIONS AND ELEVATIONS SHEET NUMBER S-1 SHEET 4 OF 8 SHEETS