HomeMy WebLinkAboutZ-4470-K Staff AnalysisJune 28, 2018
ITEM NO.: 7
NAME: Lots 3 and 4 Chenal Park Centre Zoning Site Plan Review
LOCATION, Located at 15112 and 15104 Chenal Parkway
DEVELOPER.
LLEJ Lots 9 and 10 LLC
P.O. Box 22407
Little Rock, AR 72204
OWNER/AUTHORIZED AGENT:
LLEJ Lots 9 and 10 LLC — Leonard Bowen
Grafton Tull and Associates - Agent
Rl1RVFYnR-
Global Surveying Consultants, Inc.
6511 Heilman Court
North Little Rock, AR 72118
ENGINEER:
Crafton Tull and Associates
10825 Financial Centre Parkway, Suite 300
Little Rock, AR 72211
AREA: 1.90 -acres NUMBER OF LOTS: 2
WARD: 5 PLANNING DISTRICT: 19 - Chenal
CURRENT ZONING: C-2, Shopping Center District
VARIANCE/WAIVERS: None requested.
BACKGROUND:
I L E NO.: Z-447
FT. NEW STREET: 0 LF
CENSUS TRACT: 42.16
The property located in the 15000 Block of Chenal Parkway was zoned C-2, Shopping
Center District by the adoption of Ordinance No. 15,530 on August 16, 1988. On
November 19, 2015, the Little Rock Planning Commission approved a preliminary plat
request to allow the subdivision of 6.21 -acres into four (4) commercial lots. On August 31,
2017, the Little Rock Planning Commission approved a Zoning Site Plan Review request
June 28, 2018
SUBDIVISION
ITEM NO.: 7 (Cont.
FILE NO.: Z -4470-K
for the western most lot (Lot 2). A final plat for Lot 2 was recorded in January 2018. The
site is being developed with a single building as approved.
On November 30, 2017, the Little Rock Planning Commission approved a revision to the
previously approved preliminary plat to allow the creation of five (5) lots; four (4) lots with
frontage along Chenal Parkway and the fifth lot located to the north of these lots. The
fifth lot was to be served via an access and utility easement.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The applicant is now requesting site plan review as per Section 36-126 of the Little
Rock Code of Ordinances. The applicant is requesting site plan approval for
two (2) lots located in the Chenal Park Center Subdivision. Lot 3 is proposed
containing a one (1) story retail building with 6,710 square feet. A drive-through
window at each end of the building is proposed. The plan indicates 42 parking
spaces and a service drive behind the building. The site plan also provides for an
enclosed dumpster area at the rear of the lot. Cross access with Lot 4 is proposed.
Lot 4 is proposed containing a one (1) story building with 7,836 square feet and a
drive-through window at each end of the building. The site plan indicates
45 parking spaces. An enclosed dumpster area and service drive are indicated
behind the building. Cross access with Lot 3 is proposed.
Each lot is proposed with a ground mounted monument sign located within the
front landscaped area. The signs are proposed with a maximum sign height of
eight (8) feet and a maximum sign area of 100 square feet.
B. EXISTING CONDITIONS:
The property is located on the north side of Chenal Parkway near the intersection
with Wellington Hills Road. Adjacent to the site the Parkway is westbound only.
The site has been cleared and the building located on the western most lot is
currently under construction. North of this site is an apartment development which
shares an access drive with this development.
South of the site, across the Chenal Parkway median, is an apartment complex
currently under development. At the intersection of Chenal Parkway and
Wellington Hills Road (southeast corner) a convenience store is currently under
construction.
C. NEIGHBORHOOD COMMENTS:
All property owners located within 200 -feet of the site along with the Wellington
Hills Property Owners Association were notified of the public hearing.
2
June 28, 2018
SUBDIVISION
ITEM NO.: 7 (Cont.) FILE NO.: Z -4470-K
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. All comments from the previous approved zoning site plan review application
(Z -4470-J) apply to this application.
2. Show locations of order boards.
3. What are the proposed uses for the drive through(s)?
4. With the one-way rear drive aisle creates difficult access to the drive thru on
the west side of Lot 3.
5. Sidewalks with appropriate handicap ramps should be constructed along the
west side of the east access easement to the lot to the north in accordance
with Section 31-175 of the Little Rock Code of Ordinances and the Master
Street Plan.
6. With drive through proposed at the southeast driveway which can back vehicles
into the intersection and cause vehicles to angle across the intersection, the
southeast driveway should be removed.
E. Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authority: Sewer main extension required, with
easements, if new sewer service is required for this project. Grease trap analysis
required if food service on site. Contact Little Rock Water Reclamation Authority
for additional information.
Entergy: Entergy does not object to this proposal. There do not appear to be any
conflicts with existing electrical utilities at this location. There is an existing three
phase, overhead power line on the south side of Chenal Parkway near this
location. There is also a three phase, overhead power line running on the east
side of Wellington Hills to the west of this location. Contact Entergy in advance to
discuss electrical service requirements, or adjustments to existing facilities (if any)
as this project proceeds.
Center oint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
3
June 28, 2018
SUBDIVISION
ITEM NO.: 7
FILE NO.: Z -4470-K
2. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional
review. Contact Central Arkansas Water regarding procedures for installation
of water facilities and/or fire service. Approval of plans by the Arkansas
Department of Health Engineering Division and the Little Rock Fire Department
is required.
3. This development will have minor impact on the existing water distribution
system. Proposed water facilities will be sized to provide adequate pressure
and fire protection.
4. If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
5. Additional fire hydrant(s) will be required. Contact the Little Rock Fire
Department to obtain information regarding the required placement of the
hydrant(s) and contact Central Arkansas Water regarding procedures for
installation of the hydrant(s).
6. A Capital Investment Charge based on the size of meter connection(s) will
apply to this project in addition to normal charges. This fee will apply to all
connections including metered connections off the private fire system.
Fire Department,
1. Full Plan Review — Maintain Access
2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is located on a
fire apparatus access road, the minimum road width shall be 26 feet, exclusive
of shoulders.
3. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus
access roads shall not exceed 10 percent in grade except as approved by the
fire chief.
4. Loading. Maintain fire apparatus access road design as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and
loading. Facilities, buildings or portions of buildings hereafter constructed shall
be accessible to fire department apparatus by way of an approved fire
apparatus access road with an asphalt, concrete or other approved driving
surface capable of supporting the imposed load of fire apparatus weighing at
least 75,000 pounds.
5. Commercial and Industrial Developments — 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1.
4
June 28, 2018
SUBDIVISION
EM NO.: 7 (Cont.) FILE NO.: Z -4470-K
a. Section D104.1 Buildings exceeding three stories or 30 feet in height.
Building or facilities exceeding 30 feet or three stories in height shall
have at least two means of fire apparatus access for each structure.
b. Section D104.2 Building exceeding 62,000 square feet in area.
Buildings or facilities having a gross building area of more than
62,000 square feet shall be provide with two separate and approved
fire apparatus access roads.
c. Exception: Projects having a gross building area of up to
124,000 square feet that have a single approved fire apparatus
access road when all building are equipped throughout with
approved automatic sprinkler systems.
d. D104.3 Remoteness. Where two fire apparatus access roads are
required, they shall be placed a distance apart equal to not less than
one half of the length of the maximum overall diagonal dimension of
the lot or area to be served, measured in a straight line between
accesses.
6. 30' Tall Buildings -Maintain aerial fire apparatus access roads as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1 — D105.4
a. D105.1 Where Required. Where the vertical distance between the
grade plane and the highest roof surface exceed 30', approved aerial
fire apparatus access roads shall be provided. For the purposes of
this section the highest roof surfaces shall be determined by
measurement to the eave of a pitched roof, the intersection of a roof
to the exterior wall, or the top of the parapet walls, whichever is
greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a
minimum unobstructed with of 26', exclusive of shoulders, in the
immediate vicinity of the building or portion thereof.
c. D105.3 Proximity to building. At least one of the required access
routes meeting this condition shall be located within a minimum of
15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the
building on which the aerial fire apparatus access road is positioned
shall be approved by the fire code official.
d. D105.4 Obstructions. Overhead utility and power lines shall not be
located over the aerial fire apparatus access road or between the
aerial fire apparatus road and the building. Other obstructions shall
be permitted to be places with the approval of the fire code official.
7. Dead Ends. Maintain fire apparatus access roads at dead end locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4
June 28, 2018
SUBDIVISION
ITEM NO.: 7 (Cont.) FILE NO.: Z -4470-K
Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall
be provided with width and turnaround provisions in accordance with Table
D103.4. Requirements for Dead-end fire apparatus access roads.
8. Gates. Maintain fire apparatus access road gates as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus
access road gates. Gates securing the fire apparatus access roads shall
comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation
by one person.
4. Gate components shall be maintained in an operable condition at all
times and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by
fire department personnel for emergency access. Emergency
opening devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain
and padlock unless they are capable of being opened by means of
forcible entry tools or when a key box containing the keys to the lock
is installed at the gate location.
7. Locking device specifications shall be submitted for approval by the
fire code official
8. Electric gate operators, where provided, shall be listed in accordance
with UL 325.
9. Gates, intended for automatic operation shall be designed,
constructed and installed to comply with requirements of ASTM F
2200.
9. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas
Fire Prevention Code. Section C101 — C105, in conjunction with Central
Arkansas Water (Jason Lowder 501.377.1245) and the Little Rock Fire
Marshal's Office (Capt. Tony Rhodes 501.918.3757 or Capt. John Hogue
501.918.3754). Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comment received.
County Plannin : No comment.
0
June 28, 2018
SUBDIVISION
ITEM NO.: 7 Cont. FILE NO.: 2-4470-K
F. Building Codes/Landscape:
Building Code: Project is subject to full commercial plan review and approval
prior to issuance of a building permit. For information on submittal requirements
and the review process. This project will require fully developed Architectural,
Structural, Civil and MEP Plans. Contact a commercial plans examiner:
Curtis Richey at 501.371.4724; cricheyCa-),littlerock.gov.
Landsca e:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements and the Chenal Overlay District.
2. Street buffers will be required at six (6) percent of the average depth of the lot.
The minimum dimension shall be one-half ('/2) the full width requirement but in
no case less than nine (9) feet. The average depth of the lot is approximately
180 linear feet. A minimum of eleven (11) foot street buffer is required between
the property line and the Chenal Parkway right-of-way.
3. Screening requirements will need to be met for the vehicular use areas
adjacent to street right-of-ways. Provide screening shrubs with an average
linear spacing of not less at three (3) feet within the required landscape area.
Provide trees with an average linear spacing of not less than thirty (30) feet.
4. A perimeter planting strip is required along any side of a vehicular use area that
abuts adjoining property, or the right-of-way of any street. This strip shall be at
least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be
planted for every thirty (30) linear feet of perimeter planting strip. Perimeter
planting strips are required adjacent to the parking areas of Lots 3 and 4.
5. Landscape areas shall be provided between the vehicular use area used for
public parking and the general vicinity of the building, excluding truck loading
or service areas not open to public parking. These areas shall be equal to an
equivalent planter strip three (3) feet wide along the vehicular use area.
6. Eight percent (8%) of the vehicular use area must be designated for green
space; this green space needs to be evenly distributed throughout the parking
area(s). The minimum size of an interior landscape area shall be one hundred
fifty (150) square feet for developments with one hundred fifty (150) or fewer
parking spaces. Interior islands must be a minimum seven and one half
(7 1/2) feet in width. Trees shall be included in the interior landscape areas at
the rate of one (1) tree for every twelve (12) parking spaces.
7. An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
8. The development of two (2) acres or more requires the landscape plan to be
stamped with the seal of a Registered Landscape Architect.
7
June 28, 2018
SUBDIVISION
ITEM NO.: 7 (Cont.
FILE NO.: Z -4470-K
9. The City Beautiful Commission recommends preserving as many existing trees
as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
G. Trans ortation/Plannin :
Rock Region Metro: The site is not located on a dedicated Rock Region Metro
route.
Planning Division: No comment.
H. SUBDIVISION COMMITTEE COMMENT: (June 6, 2018)
Mr. Frank Riggins was present representing the request. Staff presented an
overview of the item stating there were additional items necessary to complete the
review process. Staff questioned the location of menu order boards and noted
they were required to be screened. Staff also questioned if there would be areas
of outdoor dining. Staff questioned the maximum building height and requested
Mr. Riggins include the height in the general notes section of the site plan.
Public Works comments were addressed. Staff stated all comments from the
previous approved site plan review request would continue to apply to the
development of these lots. Staff questioned the purpose of the drive-through uses
and questioned the reasoning for the one-way drive within the rear of the buildings.
Staff stated the drive-through at the southeast driveway could cause vehicles to
stack into the access drive. Staff requested the driveway be removed.
Landscaping comments were addressed. Staff stated the street buffer did not
appear to be adequate to meet the typical standards of the buffer ordinance. Staff
stated a landscape strip between Lots 3 and 4 was required. Mr. Riggins
questioned if the area was indicated as a cross access and cross parking if the
landscape strip was still required. Staff stated if the area was indicated as cross
access and cross parking the landscape strip was not required.
Staff noted the comments from the various other departments and agencies. Staff
suggested the applicant contact the departments or agencies directly with any
questions or concerns. There were no more issues for discussion. The Committee
then forwarded the item to the full Commission for final action.
ANALYSIS:
The applicant submitted a revised cover letter and site plan to staff addressing
some of the technical issues associated with the request raised at the June 6,
June 28, 2018
SUBDIVISION
ITEM NO.: 7 (Cont.
FILE NO.: Z -4470-K
2018, Subdivision Committee meeting. The applicant has indicated the order
board for the restaurant users and is requesting a waiver of the order board
screening requirement. The applicant has also indicated the maximum building
height of 30 -feet.
The request is for site plan review as per Section 36-126 of the Little Rock Code
of Ordinances. The site plan review request is for two (2) lots located in the Chenal
Park Center Subdivision. The property is zoned C-2, Shopping Center District
which requires site plan review prior to development.
Lot 3 is proposed containing a one (1) story retail building with 6,710 square feet.
A drive-through window at each end of the building is proposed. The plan indicates
42 parking spaces and a one-way service drive behind the building.
The uses for the lot have not been identified but the plan indicates two (2)
drive -through -windows which could potentially include two (2) restaurant spaces.
Parking for a restaurant is based on one (1) parking space per 100 gross square
feet of floor area. This would result in the need for 67 parking spaces. Parking for
a mixed use development is typically based on one (1) parking space per
225 gross square feet of floor area. Based on this calculation a total of 29 parking
spaces would be required to serve the development.
Lot 4 is proposed containing a one (1) story building with 7,836 square feet and a
drive-through window at each end of the building. The applicant has stated the
drive-through on the east end of the building will not be a restaurant use. The site
plan indicates 45 parking spaces.
Once again the uses have not been identified. Parking based on the site
developing as a mixed use development (one space per 225 gross square feet of
floor area) would result in the need for 34 parking spaces.
Each lot is proposed with a ground mounted monument sign located within the
front landscaped area. The signs are proposed with a maximum sign height of
eight (8) feet and a maximum sign area of 100 square feet. Building signage is
proposed on the southern fagade which is located with public street frontage.
Directional signage will be placed in compliance with the typical ordinance
standards.
Each lot is indicated with dumpster pads behind the buildings. A note indicates
the dumpster will be screened per typical ordinance standards. The applicant has
also indicated the hours of dumpster service will be limited to 7 am to 6 pm Monday
through Friday.
June 28, 2018
SUBDIVISION
NO.: 7 (Cont.) FILE NO.: Z -4470-K
As previously noted the site plan includes the placement of a drive-through window
on the east end of the building located on Lot 4. The revised cover letter indicates
the use as a bank. The applicant is requesting this drive-through be approved for
a maximum of eight (8) cars at any given time. The applicant states should the
total number of cars in queue exceed eight (8) then the developer would be
required to submit an alternate plan to the City to alleviate the issue. Staff is not
supportive of the placement of the drive-through on the east end of the building.
There is potential for cars stacking in the drive-through lanes to exceed the
maximum queue and stacking out into the main access drive. In addition to serving
this five (5) lot commercial development this access drive serves an adjacent
apartment complex. Staff does not feel the drive-through on the east end of the
building should be allowed.
STAFF RECOMMENDATION:
Staff recommends denial of the request as filed.
PLANNING COMMISSION ACTION: (JUNE 28, 2018)
The applicant was present. There were no registered objectors present. Staff presented
the item stating the applicant had agreed to limit the stacking at the easternmost
drive-through on Lot 4 to six (6) cars and to the channelization of the southeast driveway
and entrance. Staff stated they were now in support of the request. Staff presented a
recommendation of approval of the request subject to compliance with the comments and
conditions as outlined in paragraphs D, E and F of the agenda staff report. There was no
further discussion. The item was placed on the consent agenda and approved as
recommended by staff by a vote of 9 ayes, 0 noes, 1 absent and 1 recusal (Commissioner
Laha).
10