HomeMy WebLinkAboutZ-4470-D Map 3EXISTING SANITARY
SEWER
PROPOSED
CONCRETE
DRIVEWAY
PROPOSED
MONUMENT
SIGN
ORNAMENTAt-
y GATE
CpNC�ESE
>> i:� PAvjnc
=clip
PROPERTY LINE
` \ 25' BUILDING
SETBACK
/ o \ CHAIN-LINK FENCE
*10 ` \
J
15
22
I\ o
22AM
I ��
12 ` 21 25 0
Ank/ / VW
METAL ORNAMENTAL
��
\ GATES,
6
30" RCP
PROPOSED
MONUMENT
SIGN
TR�Ck ROpTE
�\ l
0PPICES
PROPOSED CONCRETE DRIVEWAY
APRON -RIGHT TURN IN, RIGHT TURN
OUT ONLY
/37/}
6J
BAR
W`�S$
USED
C`�RS
8
PROPOSED NEW
TURN LANE
45' BUILDING
SETBACK
CHENAL PARK APARTMENTS
LOT 5
CHENAL COMMERCIAL PARK
ZONED MF -18
RECORDED IN BOOK E, PAGE 425
15' BUILDING
SETBACK
PPROPERTY
-LINE
VING (TYP.j
OA
Pinnacle Ford
Chenal Parkway
Little Rock, Arkansas
PROJECT INFORMATION
Building heights: The height of the Sales and Parts building is approximately 34 feet, the service building is 22
feet and the used car building is 20 feet.
• Number of Employees: There will be a maximum of 70 employees.
• Hours of Operation: Parts and Service: 7:00 am to 6:00 pm Monday thru Friday
8:00 am to 4:00 pm Saturday
Sales: 8:00 am to 8:00 pm Monday thru Friday
9:00 am to 7:00 pm Saturday
12:00 am to 5:00 pm Sunday
• Site Lighting: All exterior lighting will be focused inward to minimize or eliminate ambient light into adjacent
neighborhoods or developments; maximum heights of poles will be 40 feet and footcandles will be reduced after
hours of operation.
6' WOODEN FENCE • There will not be aand aint body
( FACE SIDE DIRECTED P y sho p, general maintenance and repairs will be done on site.
OUTWARD) . There will be no outside paging allowed at dealership.
• The dealers will not allow test drives through the adjacent residential neighborhood
Total Parking Spaces 536
Stockpile Area: Excess earth material that is excavated from lot
1 will be stockpiled in this area designated by crosshatching
The existing drainage channel will not be impeded during construction
Stock pile area will be seeded and mulched upon completion
-
`i I' Ij jl 9
TYPICAL PARKING
100' Undisturbed Buffer
All trees and vegetation within this 100' undisturbed buffer
will remain undisturbed as a condition for advanced clearing
and grading of lots 2 through 6. The buffer will remain in
place until each lot is developed at which time the buffer will
be reduced to that width required by the city regulation and
permitted,
MONUMENT SIGN NOT TO
EXCEED 100 S.F.
50
%%%"?!!!I
0 50 100 FEET
SCALE 1 "=50'-0"
The Mehlburger Firm, Inc.
Civil Engineers (;� Environmental Engineers
Landscape Architects (;t Surveyors