Loading...
HomeMy WebLinkAboutZ-4470-L Map 2C� SCREENED DUMPSTER 1 1 1 I I r, yUI f NEW CURB AND ON CONCRETE PAD •IlTucr�� GUTTER (TYP.) -� �� 11; -- WHITE DIRECTIONAL �— !) ; ARROWS (TYP) vw—_ c4r�-� I %. --UCT�— � TRANSFORMER PAD - :•.. 1.:, �- --`. 10' UTILITY EASEMENT 10' UTILITY EASEMENT I ..1'il �_ 1/u1-1` ��o REGULAR DUTY - ---- -------------------- _ 'C :.';.;,:''�`:.. II 1 "/ H TY - 4'gp ASPHALT .. CONCRETE (TVP.) 1-3 i; /� ; • HEAVY DUTY 24 'LEFT TURN ONLY' SIGN A�Y� Y Y�Q I i 1 j NEW WHEEL STOPS 6, HEAVY DUTY DO NOT ENTER' I (TYP.) j; 12' ASPHALT (TYP.) 4" DASHED YELLOW LINES SIGN R18 11 (TYP.) / i 'fir ti �i l s A I I SIDEWALK RAMP 12' 2614.85' 11.68' 16' WITH TACTILE PANEL REGUL-AR DUTY 1 1I I (TYP.) LOT 3 CHENAL ( ASPHALT (TVP.) I 'I 1i i 1 PARK CENTRE I F, it �I ;;; 1- H NEW CONCRETE NEW BUILDING ACCESSIBLE SIDEWALK (TYP.)BUILT j UP if PLANTER (TYP.)ING SIGN ACCESSIBLE r (TVP.) RAMP (TYP.) ; II rr 1 �9 1 h it �' /)20' 'STOP' SIGN pCROSSWALK I E� -----� ---� ----- --- -- ---� I CROSSWALK & n �\ /\ , 'DO NOT ENTER' R20' R20 R5, R7 STOP BAR 1 0' I� I SIGN REGULAR DUTY ASPHALT 00© 9' - _ _ � (TYPo_- 1 11 1-2 Et5 - Py �__ _9 -- - RS RS• ----(TYP-)-RS" (TYPJ 1 - __W ao r155' 11' 1155' LABOR EASEMENT ( N (TYP.) HEAVY DUTY MONUMENT i{ 11 __ _ _ ASPHALT/(TYPJ _- SIGN If - - -- - -W- r1------=---1 - �__ PROPOSE COMMERCIAL - PS' �� (TYP.)_--W_- REGULAR DUTY W REGULAR DUTY (TYP•) -W / II ` SUBDIVISION SIGN ASPHALT (TYP.)- ss- �_ _ -- �- -� - 10 -_ ASPHALT (TYP.) 2-1 vg� /ll Tt N �� • / '� ;r__ P�.�,/%r�l��l x192.55' _ __ ---uc, as —gym--- 86' ��, sh \ NEW CURB AND 17.3 ------ a4r--- _-------- _ 7' ---- - +_ _ GUTTER (TYP.) y� -----"------------------------- - -y-very=�acr-'== ucr -i-`\ I/ "�--roWr'.��--�ucr��_-- - - ucr--= —_UGr--- /' ATT Sign -vn= -'k-- >���-___��aac-.-o/ n— _ — � ' ' ucr —,—�� _ 4" WHITE —u4r— �CL.ev.`>— ucr -- �U4T� �3Z uor '----- -1 — —ucr--.-- _-- —gun= STRIPE (TYP) ucr--- -„�.r --ucr -_- N Chenal Parkway ,---.________Principal Arterial—One Way West - ---lRigfiu of Way (50') 2 Lanes 24' Asphalt (40 GENERAL NOTES © 1. THE DESIGN, INSPECTION, AND CERTIFICATION OF ANY RETAINING WALL SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT LIMITED TO, SEGMENTAL RETAINING WALLS, MASS GRAVITY WALLS, GABION WALLS, ETC., GREATER THAN FORTY-EIGHT INCHES IN HEIGHT, GRAPHIC SCALE IN FEET SHALL BE BY OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN SHALL BE ONLY FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS. 2. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES 20' 0 20' SHOWN ON THESE DRAWINGS IS BASED ON A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS. GRAFTON TULL ASSUMES NO RESPONSIBILITY REGARDING THE ACCURACY OF THE DEPICTED LOCATION(S) OF THE UNDERGROUND FACILITIES ON THESE DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ANY OTHER FACILITIES NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL VERIFY LOCATION OF ALL FACILITIES BEFORE BEGINNING WORK. 3. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN OR NEAR THE CONSTRUCTION SITE. 4. THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIGNAL SERVICES, IS THE PROPERTY OF GRAFTON, TULL & ASSOCIATES, INC. AND IS NOT TO BE USED IN WHOLE OR PART FOR ANY OTHER PROJECTOU WITHOUT THE WRITTEN AUTHORIZATION OF GRAFTON TULL & ASSOCIATES, INC. 5. CONTRACTOR SHALL NOT CAUSE ANY LONG-TERM INCONVENIENCE TO THE PUBLIC, ADJACENT PROPERTY OWNERS, PEDESTRIANS, ETC. DURING CONSTRUCTION OF THIS PROJECT. CONTRACTOR SHALL PROVIDE ACCESS TO ALL ADJACENT PROPERTIES AT ALL TIMES DURING CONSTRUCTION. 6. CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY IS IDENTIFIED IN THE PLANS OR SPECIFICATIONS. 7. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT WHICH ARE NECESSARY TO CONFORM TO OSHA, FEDERAL, STATE AND LOCAL REGULATIONS. 8, GRAFTON TULL & ASSOCIATES, INC. (CTA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES FOR THE WORK INDICATED ON THESE DRAWINGS. THEREFORE, CTA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT GRAFTON, TULL & ASSOCIATES, INC. ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION, OR ADMINISTRATION OF THESE DOCUMENTS AND/OR DEVIATIONS THEREOF. FURTHERMORE, GRAFTON, TULL & ASSOCIATES, INC. WILL NOT BE RESPONSIBLE FOP. ANY EFFECTS THAT ANY CHANGES TO THESE DOCUMENTS MAY HAVE ON ANY RELATED TRADES, CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT EXCEPT AS SPECIFICALLY NOTED IN THE AGREEMENT BETWEEN GRAFTON, TULL & ASSOCIATES AND THE OWNER. SITE NOTES 1. THE DESIGN, INSPECTION, AND CERTIFICATION OF ANY RETAINING WALL SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT LIMITED TO, SEGMENTAL RETAINING WALLS, MASS GRAVITY WALLS, GABION WALLS, ETC., GREATER THAN FORTY-EIGHT INCHES IN HEIGHT, SHALL BE BY OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN SHALL BE FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS ONLY. 2. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA STANDARDS. 3. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. 4. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 5. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 6. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE. 7. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. B. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. 9. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM THE SITE - LEGEND (CONSTRUCT) SbIBVSLINEWORK ------------- • SET IRON PIN EASEMENT •> LIGHT POLE k POWER POLE CURB ■ TELEPHONE PEDESTAL i2m IN TVPEDESTAL INTERMEDIATE CONTOUR Arkansas One Call Know what's below, Call before YOU dig MANHOLE—I�- -- INDEX CONTOUR o SANITARY SEWER CLEANCUT s ♦ GAS METER SANITARY SEWER LINE N GAS VALVE W O STORM SEWER PIPE GAS LINE STRUCTURE NUMBER N WATER VALVE WATER LINE +N- FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE IBI AIR RELEASE VALVE uc 1 A FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC • WATER METER °�- ■ BACK FLOW PREVENTER OVERHEAD ELECTRIC • REDUCERn FIBER OPTIC RECTANGULAR DROP INLET, GRATED INLET OR JUNCTION holy BOX (SPECIFY ON PLAN UNDERGROUND TELEVISION SHEER —41N -am —MN— OVERHEAD TELEVISION CIRCULAR DROP INLET, GRATED INLET OR ,UNCTION CHAIN LINK FENCE BOX (SPECIFY ON PLAN SHEER (--T N90D FENCE iCONCRETE smEwAU( BARBED WIRE FENCE HEAVY DUTY ASPHALT BURRING SET BACK HEAVY CONCRETE PAVEMENT RIGHT OF WAY - PROPMTY LINE REGULAR DUTY ASPHALT ROAD ROAD CENTERLINE to LEGEND (EXISTING SYMBOLS) $VII m LINEWORK ------------------ 0 FOUND IRON PIN EASEMENT Il LIGHT POLE R POWER POLE CURB m TELEPHONE PEDESTAL .. _..__ ... _.._ 0 TVPEDESTAL INTERMEDIATE CONTOUR O MANHOLE INDEX CONTOUR c SANITARY SEWER CLEANOUT GAS METER SANITARY SEWER LINE D4 GAS VALVE GAS LINE STORM SEWER PIPE W DOW1 GUY WATER LINE (SPECIFY SIZE & TWO C`< WATER VALVE -V FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE + L81 AIR RELEASE VALVE u4 — t --ucE { UNDERGROUND ELECTRIC Za FIRE DEPARTMENT CONNECTION O WATER METER OVERHEAD ELECTRIC ® SPRINKLER HEAD-ucN---u.---um— ELECTRIC . umELECTRIC PEDESTAL UNDERGROUND IELEVISION —ONN --pNN OHry 1 GRATED INLET OVERHEAD TELEVISION - _ CHAIN LINK FENCE . . . DROP INLET I. WOOD FENCE _ o P BARBED WIRE FENCE TREE b .,. FIBER DPtrc `c �x''f� RIGHT OF WAY TREE TO BE REMOVED - - _ ROAD CENTERLINE RETAINING WALL DESIGN, INSPECTION, AND CERTIFICATION BY OTHERS Z mLj v J U o¢ Q �O ¢m O Yv ¢ of Z LLJ L) w 0 z k> o. cc r� vJ Cc W ^/ w YZ�Z ~In o LL O N Q � J ~ tj w� Owww 53M cr a- 0- C mo XH 8101 ” d3S 03 cC n, Lli W < U� O O J cz_cz n � ■i � d (LS C BBBBBBBB� 4) cz � N C T Ll7 T U 10825F anc aI C— P R y \ 1. 2" L ;I, Rock k Crafton Tull 501 66452451 501 664A/U4I n Imp,:. OF AUTti CRAFTON, TULL& >I'. =r ASSOCIATES, INC. cy- No. 109 p= J ' q�rAN ,AS EN�PNE�� SITE PLAN 1 MONUMENT SIGN 09/20/18 REVISIONS I DATE ISSUED FOR BID G gTATE Op ARK, AS REGISTERED PROFESSIONAL ENGINEER o. * * * 217 Y q 3PE'\���o� OR REFERENCED HEREIN, SI INCLUDINGCTIONBUT NOTDLIMITED TO, SEGMENTAL RETAINING WALLS,CERTIFICATION OF ANY RETAINING WALLSHOMASS GRAVITY WALLS, 6-6-18 1621 GABION WALLS, ETC., GREATER THAN FORTY-EIGHT INCHES IN HEIGHT, SHALL BE BY OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN SHALL BE FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS ONLY. DATE JOB NO. THE OWNER/CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR OBTAINING AND PROVIDING SEPARATE AND WALLBY A REGISTERED PROFESS ONALENT ENGINEERINING SIGNS OTHER THAN EGRAFTONI TULL NSPECnTTH S SHALL ALSO ONS, ANDIAPPLOYNTO ANY ASSOCIATED C-101 13 AND NECESSARY PUBLIC SAFETY DEVICES INCLUDING, BUT NOT LIMITED TO, PEDESTRIAN SAFETY RAILS. SHEET OF