Loading...
HomeMy WebLinkAboutZ-4432-C Map�f PROJECT INFORMATION SCOPE OF WORK: UNMANNED TELECOMMUNICATIONS FACILITY MODIFICATIONS 1 3000 OZARK POINT SITE ADDRESS: LITTLE ROCK, ARKANSAS 72205 LATITUDE: 34' 45' 26.23' N LONGITUDE: SIT 18' 32.77" W JURISDICTION: PULASKI COUNTY, ARKANSAS CURRENT USE: TELECOMMUNICATIONS FACILITY PROPOSED USE' TELECOMMUNICATIONS FACILITY A/E DOCUMENT REVIEW STATUS St+tm1 Code 1 Lwaptsd - TITh minar or no comments, o bcucftort — raaoed E Not Iaaapted - PLeue rejobe oomments and rombudt Loeeptaan dare nat mnstnata approTar or de@Un detallr. ealevtatlms, ans1�*, test methods or matariela deralapad or aabsdfsd by the enboonteactor and dare apt rattsrn suboontmator tram to.0 aampnt ao v1th mutswetual obltiatlaos. &erl ewnd i' BY Data 0 COKSTRUMON F' r CDfGiII,AR f E• DRAWING INDEX S REV 24782 -LTR -065-01 TITLE SHEET � - 0 24782 -LTR -065-02 SITE PLAN 0 24782 -LTR -065-03 ELEVATION VIEW AND RF NOTES 0 24782 -LTR -065-04 SLAB DETAILS Q 0 24782 -LTR -065-05 CONSTRUCTION NOTES P� i LL. 0 24782 -LTR -065-06 GPS MOUNTING DETAILS > 0 24782 -LTR -065-07 CONSTRUCTION DETAILS 0 24782 -LTR -065-08 ELECTRICAL NOTES AND DETAILS 0 24782 -LTR -065-09 GROUNDING DETAILS 0 24782 -LTR -065-10 GROUNDING DETAILS 0 24782 -LTR -065-11 GROUNDING PLAN 0 24782 -LTR -065-12 COAX COLOR CODING 0 24782 -LTR -065-13 RISER DIAGRAM a 24782 -LTR -065-14 TELCO CONNECTION DIAGRAM 0 24782 -LTR -065-15 RF AUTOMATIC DOWNTILT SCHEMATIC 0 24782 -LTR -065-16 SHELTER LAYOUT AND CABINET DETAILS 0 NOTES 1. SEE THE FOLLOWING NOTES. SYMBOLS AND DETAILS, BECHTEL DOCUMENT NUMBER 24782 -000 -A3 -EF -00001 FOR THE IMPLEMENTATION OF THIS SITE DESIGN PACKAGE: CONCRETE AND REINFORCING STEEL NOTES DETAIL 102 DETAIL 103 APPLICABLE BUILDING CODES AND STANDARDS RF NOTES SITE WORK GENERAL NOTES DETAIL 116 DETAIL 619 STRUCTURAL STEEL NOTES ELECTRICAL INSTALLATION NOTES DETAIL 570 DETAIL 622 GENERAL NOTESDETAIL ICE BRIDGE DETAIL 623 DETAIL 155 DIRECT BURIED CONDUIT ANTENNA CABLE GROUNDING GUYED TOWER IDETAL 105 DETAIL 632 GROUND ROD INSTALLATION OF GROUND WIRE TO GROUND BAR DETAIL 114 DETAIL 118 REFERENCE GROUND BAR (RGB) DETAIL DETAIL 119 DETAIL 122 CONNECTION OF GROUND WIRE TO GROUNDING BAR DETAIL 644 GROUND ROD WITH ACCESS AREA COAX COLOR CODING AND ID DETAIL FOR GREENFIELDS DETAIL 636 ABBREVIATIONS AND SYYBOL.S CONNECTION OF CABLE GROUND KIT TO ANTENNA CABLE DETAIL 112 DETAIL 121 ANTENNA CABLE GROUNDING. dr SURGE ARRESTORS AT SHELTER DETAIL 129 Wair��ac La'E_Ic� CROUP 3775 Villa Creek De, Suite ISO, Dallas, Texas 75234 !'hone (972)414.6855 Fax: (972) 484-6830 WDG VRC)JECT #0500496 fi 5 Ar-pnoy� - AEVI+I . R 'Tiv - - Z— Wions 3 a-- _ 14: Di_VlAfl.0-M FR&AAPPROVED • Sil_" PLAN, V00S TH IS PERMIT. AS -BUILT REDLINE THE MARK-UP ON THIS DRAWING REFLECTS THE AS -BUILT INSTALLA71N. Subcontractor Date ■ cingular WIRELESS 41S_&Z ` ARKANSAS INTEGRATION Field Coordinator Coate Market Engineer shall review redline drawings to ensue, changes du not alter the original designintent and/or are code cont 11' tit tarkct Lead En,incet DoT VICINITY MAP EH rca S Q '•tin � - r-' :. M1•1� ILUE1'Pi0a11'�f i3j�' �� Q LU P� i LL. dar�VOr Ls > SITE NUMBER:-.AR1555 SITE NAME: KAVANAUGH (L-055) APPLICABLE BUILDING CODES AND STANDARDS C DIRECTIONS: FROM 1-630 AND S WOODROW ST. TAKE S WOODROW ST NORTH FOR HALF A MILE, TURN SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPUCA13LE NATIONAL, STATE, AND LOCAL CODES LEFTONTO W MARKHAM ST. TURN SLIGHT RIGHT ONTO KAVANAUGH BLVD. TURN RIGHT ONTO LEE AVE. AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE TURN LEFT ONTO FAIRFAX TERRACE. TURN RIGHT ONTO OZARK STREET AND FOLLOW TO THE SITE. EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. BUILDING CODE/FRE PREVENnOt4/SAFETY/ACCESSIBILTY CODE: ARKANSAS FIRE PREVENTION CODE (20DO IBC AND 2000 IFC WITH STATE SUPPLEMENTS) 1r11r)-babxa da , r ` AWOW P_ K T V(f°fldlayspQ ir Azq 5r4 :. ,f11 41tth-'St. `:i w ai ILL_ �ynfb KAVANAUGH (L-065) SITE NO. AR1565 3000 OZARK POINT LITTLE ROCK, ARKANSAS 72205 4 _ S '•tin � - r-' :. M1•1� ILUE1'Pi0a11'�f i3j�' f i �,y► :i dar�VOr Ls > r rL4 MECHANICAL CODE: CODE (IMC 1997 WITH STATE AMENDMENTS) Xcingular WIRELESS 3 ARKANSAS MEC �; ELECTRICAL CODE. 2002 NATIONAL ELECTRICAL CODE (NEC) GAS CODE: ARKANSAS STATE GAS CODE (1995 SGC WITH STATE AMENDMENTS) - SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS. AMERICAN CONCRETE INSTITUTE (ACt) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE i AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, = NINTH EDITION c TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TTA) 222-F, STRUCTURAL STANDARDS FOR STEEL B ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES: TIA 607, COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS - INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH RESISTNfTY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC EQUIPMENT IEEE C62.41. RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION CATEGORY -C3- AND -HIGH SYSTEM EXPOSURE-) TELCORDIA GR -1275, GENERAL INSTALLATION REQUIREMENTS TELCORDIA GR -1503. COAXIAL CABLE CONNECTIONS ql ANSI T1.311, FOR TELECOM - DC POWER SYSTEMS - TELECOM, ENVIRONMENTAL PROTECTION FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION. OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. ...._- DETAIL103 A 0a �..-..`/ uTC p 102/0$/%1 ISSUED FOR CONSTRUCTION *. DATE I REVISIONS CAL AS SHOWN DESIGNED BY". NMB CINGULAR WIRELESS TITLE SHEET be NUYBFR sRe NW BER ocwnNa 7sr 24782 LTR -065 24782 -LTR -065-01 10 ?Sr- 1:1 KAVANAUGH (L-065) FCC SITE #1204238 NOTE: OPTIONAL POWER AND T1 — PLACEMENT OF H—FRAME STAND—OFF FROM POWER SOURCE AND UNDERGROUND CONOUITING FROM TRANSFORMER POLE FOR POWER AND TI. CONDUITING FROM H—FRAME TO EQUIPMENT FOR POWER AND T1. (RE DETAILS 1/13 AND 1/14) (E) EQUII'!AENT TO BE - 38'-0. 1. REMOVE: S" OTHERS �.r -- f-- -- (E) POWER PANEL (E) ICE BRIDGE(POINT OF CONNECTION TO BE REMOVED 5 f FOR GNGULAR POWER) _ �X-i—X-- x---X—X— X—X—X—X—X—X- �- ,,-(E) TELCO PANEL X (N) (2) 3' PVC SCHEDULE 40 CONDUIT FOR U.G. TELCO 11 (POINT OF CONNECTION WITH 1800 LB MULE TAPE, 1 �N X FOR CINGULAR TELCO) I PULL STRINGS AND CAPS r 1 l (RE: 1/14 & 105/08) +� ' l f r j RACK X X 3 (E) TELCO•-. 1'•ti 1 f PEDESTAL 1: ` X -- F_X —X --� XX—X !F (3) ,#.3/0 AND (1) #6 GROUND - x IN 2' PVC SCHEDULE 40 PIPE . -- I i (E) BUNKER lX FOR (N) U.G. POWER , 1 (RE: I & 2/13 & 105/08) I �• i r a� (E) POWER POLE" , �� I (E) ICE BRIDGE X ,l AND TRANSFORMER F\4 PLACE (N) 11'-5' X 20'-0" ^" �j+ A ! -- _� COAX CABLES J CONCRETE SLAB FOR i (N) SHELTER (RE: SHT 04) tk 30,-Q, d X—Xx� t X —X —X —X (E) GATE WAEL CE Dj51G-% c Ra-ui' 2775 Villa Creek Dr. Suite L50, Dallas, Texas 75234 Phone: (972) 494.6655 Fax: (972) 484-6836 WDG PROJECT #0500496 4 6 6 KAVANAUGH (L-065) SITE NO. AR1565 3000 OZARK POINT LITTLE ROCK, ARKANSAS 72205 BLOCK HOUSE X X yf (E) 300'-0" GUYED TOWER --(N) ICE BRIDGE (RE: 155/08) X OF (E) (12) 1 -5/8 - COAX CABLES TO BE REUSED X X —X —X —X —X —X —XX —X Xl -•• --T---MOUNT (E) GPS ANTENNA TO (N) ICE BRIDGE (RE: 1&2/06) (E) FENCE 4 Xcingular WIRELESS S ITE P LAN L 1 SCALE: 1/8" -l' -O' () 2 !O2/OS�OGj ISSUED FOR CONSMICf1ON I CEC I r,Oq NO. DATE REVISIONS I BY I cog AS SHOWN DESIGNED BY: NWB D-Ift" BY: NMB 3 2 GENERAL NOTE SCALE NOTED APPLIES TO 22'x34' SHEET SIZE IF PRINT SIZE IS 11'07', THEN ACTUAL SCALE IS ONE HALF OF SCALE NOTED. EXAMPLE: 1/2' z 1'-0' BECOMES 1/4' - 1'-0' ON 1 T'x17' SHEET SIZE). THIS NOTE APPLIES TO ALL DRAWING SHEETS. LEGEND EXISTING EQUIPMENT NEW EQUIPMENT r , FUTURE EQUIPMENT EXISTING CABLE TRAY/ BRIDGE NEW CABLE TRAY/ BRIDGE CONDUCTORS AND RACEWAY TO BE FURNISHED & INSTALLED BY SUBCONTRACTOR NORTH ARROW SCALE: NONE CINGULAR WIRELESS SITE PLAN LTR -0651 24782 -LTR -065-02 0 C B A �i TOP OF TOWER ELEV t 300'-O" ANTENNAS -----{E) LINGULAR ANTENNAS ALLGON MODEL UXC-1900-65-17.5-A6-D (2) ANTENNAS PER SECTOR ((E) ANTENNAS TO BE REUSED) ANTENNA RAD CENTER ELEV t 140'-0" NOTE; \--(I,) MICROWAVE (E) )I ) TO BE REPLACED DISH ANTENNA MODEL KRY11271/2 TMAs /-(E) MICROWAVE DISH ANTENNA --'(E) 300'-0- GUYED TOWER (GUY WIRES NOT SHOWN FOR CLARITY) v'COAX CABLES 8" t� N0 =: S UCTU AL ANALYSIS /-(N) 11'-5" X 20'-0' OF TOWER PROVIDED BY OTHERS. I. / SHELTER EPLACE (E) SURGE -•-(N) ICE BRIDGE RRESTORS WITH HUGER- (RW_ 155/08) UHNER HS3409-41-0044 WAC DEIGN GROUP 2775 Villa Creek Dr, Suite 150, Dallas,Texas 75234 Phone: (972) 44-6835 Fax: (972) 484-6830 WDG PRIOJECT 90500496 6 1 5 FINISHED-, GRADE ELEV t O' -O' Ix Irfz x� D �Ib — a STABILIZER ARM (TYP.) 0 i (E) GUYED TOWER -r ---(E) (6) CINGULAR ANTENNAS, ALLGON UXC-1900-65-17.5-A6-D (2) ANTENNAS PER SECTOR TWO ANTENNA CONEIOURATI()N TOWER MOUNTING PLAN VI W RF NOTES: 1. ACTUAL LENGTHS SHALL BE DETERMINED PER SITE CONDITION BY SUBCONTRACTOR. 2. THE DESIGN IS BASED ON RF DATA SHEETS, SIGNED AND APPROVED. 3. RADIO SIGNAL CABLE AND RACEWAY SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC. NFPA 70). CHAPTER 8. 4. ALL SPECIFIED MATERIAL FOR EACH LOCATION (E.G.. OUTDOORS, NDOORS-OCCUPIED, INDOORS -UNOCCUPIED, PLENUMS, RISER SHAFTS, ETC.) SHALL BE APPROVED, LISTED, OR LABELED AS REQUIRED BY THE NEC_ S. RADIO SIGNAL CABLE SHALL BE SUPPORTED AT MINIMUM OF EVERY THREE (3) FEET EXCEPT INSIDE MONOPOLES OR LATTACE TOWERS WHERE CABLE AND CONNECTOR MANUFACTURERS SUPPORT RECOMMENDATIONS SHALL BE FOLLOWED. MANUFACTURER RECOMMENDED CABLE SUPPORT ACCESSORIES SHALL BE USED. 6. THE OUTDOOR CABLE SUPPORT SYSTEM SHALL BE PROVIDED WITH AN ICE SHIELD TO SUPPORT AND PROTECT ANTENNA CABLE RUNS. 7. DRIP LOOPS SHALL BE REQUIRED ON ALL OUTSIDE CABLES. CABLES SHALL BE SLOPED AWAY FROM THE BUILDING OR OUTDOOR BTS CABINETS TO PREVENT WATER FROM ENTERING THROUGH THE COAXIAL CABLE PORT. B. ALL FEEDER UNE AND JUMPER CONNECTORS FOR CINGULAR GSM SHALL BE CINGULAR APPROVED 7/16 DIN CABLE CONNECTORS THAT MEET IP68 STANDARDS. 9. DELETED 10. 7/16 DIN CONNECTORS REQUIRE NO ADDITIONAL WEATHER PROOFING IN INDOOR APPLICATIONS IF INSTALLED AND TORQUED PROPERLY. IN OUTDOOR APPLICATIONS WEATHER PROOFING IS REQUIRED AND THE FOLLOWING PROCEDURE SHOULD BE FOLLOWED: APPLY A 'COURTESY" WRAP OF ONE LAYER OF 7MIL THICK VINYL ELECTRICAL TAPE EXTENDING APPROXIMATELY ONE (1) INCH ON EACH SIDE OF THE COAX CABLE/ CONNECTOR JUNCTURE. USING WEATHERPROOFING KIT APPROVED BY CABLE MANUFACTURE AND CONTRACTOR. START TAPE APPROXIMATELY 5 INCHES FROM THE CONNECTOR AND WRAP 2 INCHES TOWARD THE CONNECTOR, THEN REVERSE THE TAPE SO THAT THE STIM SIDE IS UP. DETAIL TAPE OVER THE CONNECTOR OR SURGE ARRESTOR UNTIL THREE (3) TO FOUR (4) NTS INCHES BEYOND THE CONNECTOR AND REVERSE AGAIN WTTFI THE STICKY SIDE DOWN FOR ANOTHER INCH OR TWO. ADD THE BUTYL RUBBER AND FINISH WITH A FINAL LAYER OF TAPE. 11. DELETED 12. ANTENNAS SHALL BE PAINTED, WHEN REQUIRED, BY THE LANDLORD OR AUTHORITY HAVING JURISDICTION IN ACCORDANCE WITH ANTENNA MANUFACTURERS' SURFACE PREPARATION AND PAINTING REQUIREMENTS. 13. CABLE SHIELDS, AND TOWER CONDUITS SHALL BE GROUNDED AT THE TOP OF THE TOWER. WITHIN 10 FEET OF THEIR CONNECTORS, AND AT THE BOTTOM OF THE TOWER ABOUT 6 INCHES BEFORE THEY TURN TOWARD THE FACILITY. THEY SHALL BE GROUNDED AT THE MIDPOINT OF TOWERS THAT ARE BETWEEN 100 FEET AND 200 FEET HIGH, AND AT INTERVALS OF IOD FEET OR LESS ON TOWERS THAT ARE HIGHER THAN 200 FEET. 14. APPROVED GROUNDING KITS. WHICH INCLUDE GROUNDING STRAPS, SHALL BE USED TO GROVNO THE COAXIAL CABLE SHIELDS. AND CONDUIT'S. THE GROUND CONDUCTORS FOR THE KITS AT THE TOP OF THE TOWER, AND IN THE MIDDLE SECTION OF THE TOWER, ARE BONDED DIRECTLY TO TOWER STEEL USING EXOTHERMIC, BOLTED, OR APPROVED CLAMP CONNECTIONS. 15. ALL RADIO SIGNAL CABLE SHALL BE LABELED PER MARKET REQUIREMENTS 16. DELETED 17. DELETED 1B. MHA/TMA'S TO BE (NSTAI.LED AT TOWER TOP, SHALL BE SUPPLIED TO THE SUBCONTRACTOR (WHERE REQUIRED) AND INSTALLED BY THE SUBCONTRACTOR. THE GROUND CONDUCTORS OF THE TMA MAY BE BONDED DIRECTLY TO THE TOWER STEEL USING EXOTHERMIC, BOLTED, OR APPROVED CLAMP CONNECTIONS. 19. ANTENNA FEED UNE SYSTEM SWEEP TESTING SHALL BE PERFORMED AND REPORTED IN ACCORDANCE WTTH THE REQUIREMENTS OF CINGULAR-GSM SERVICES PROJECT DOCUMENT NO. 24782-000-3PS-EFYO-00001. CONTRACTOR WILL NOT ACCEPT A RADIO SIGNAL CABLE INSTALLATION WITH UNSATISFACTORY SWEEP TEST RESULTS. TOWER ELEVATION G3 I QE SCALE: 1/8'=1'-O" 1 Nom/ Yf KAVANAUGH (L-065) SITE NO. AR1565 3000 OZARK POINT LITTLE ROCK, ARKANSAS 72205 4 Xcingular WIRELESS 3 '[, `<,\ LINGULAR WIRELESS ELEVATION VIEW AND RF NOTES r t. L� 24782 LTR -965 24782 -LTR -065-03 0 C EN 19 A r/ i 0 02/01/08 ISSUED FOR CONSTRUCTION CEC 40. DATE REMSIONS BY CHK AS SHOWN DESIGNED BY: NUB DRAWN BY; NUB 2 '[, `<,\ LINGULAR WIRELESS ELEVATION VIEW AND RF NOTES r t. L� 24782 LTR -965 24782 -LTR -065-03 0 C EN 19 A