Loading...
HomeMy WebLinkAboutZ-4243-D Elevations 111522REMOVE EXISTING STOREFRONT DOOR. REPLACE OPENING WITH ALUMINUM MULION AND GLASS TO MATCH ADJACENT PANELS3' - 0"VERIFY8' - 0"REMOVE EXISTING STOREFRONT DOOR. REPLACE OPENING WITH ALUMINUM MULION AND GLASS TO MATCH ADJACENT PANELSREMOVE EXISTING STOREFRONT DOOR. REPLACE OPENING WITH ALUMINUM MULION AND GLASS TO MATCH ADJACENT PANELSREPLACE EXISTING CONCEALED FASTENER METAL PANELS W/ CAP TRIM AT EXISTING SIGNAGE BANDREPLACE EXISTING CONCEALED FASTENER METAL PANELS W/ CAP TRIM AT EXISTING SIGNAGE BANDREPLACE EXISTING CONCEALED FASTENER METAL PANELS W/ CAP TRIM AT EXISTING SIGNAGE BANDREMOVE EXISITNG DAMAGED GLAZING RUBBER AND RE-RUBBER EACH PANEL AT STOREFRONT FRAMES. PAINT ALL EXISTING STOREFRONT ALUMINUM MULLIONS PROPOSED NEW WALL28' - 4"16' - 0"PRE-FINISHED METAL PARAPET CAPEIFS WALL -PAINT13' - 0"14' - 0"13' - 0"A4.15REPLACE EXISTING CONCEALED FASTENER METAL PANELS W/ CAP TRIM AT EXISTING SIGNAGE BANDREPLACE EXISTING CONCEALED FASTENER METAL PANELS W/ CAP TRIM AT EXISTING SIGNAGE BANDREPLACE EXISTING CONCEALED FASTENER METAL PANELS W/ CAP TRIM AT EXISTING SIGNAGE BAND13' - 0"REMOVE EXISTING STOREFRONT DOOR. REPLACE OPENING WITH ALUMINUM MULION AND GLASS TO MATCH ADJACENT PANELSREMOVE EXISTING STOREFRONT DOOR. REPLACE OPENING WITH ALUMINUM MULION AND GLASS TO MATCH ADJACENT PANELSREMOVE EXISTING STOREFRONT DOOR. REPLACE OPENING WITH ALUMINUM MULION AND GLASS TO MATCH ADJACENT PANELSREPLACE EXISTING CONCEALED FASTENER METAL PANELS W/ CAP TRIM AT EXISTING SIGNAGE BANDREPLACE EXISTING CONCEALED FASTENER METAL PANELS W/ CAP TRIM AT EXISTING SIGNAGE BANDREPLACE EXISTING CONCEALED FASTENER METAL PANELS W/ CAP TRIM AT EXISTING SIGNAGE BANDREMOVE EXISITNG DAMAGED GLAZING RUBBER AND RE-RUBBER EACH PANEL AT STOREFRONT FRAMES.13' - 0"14' - 0"13' - 0"EXISTING OPENING10' - 0"COILING DOOR4' - 0"VERIFY2' - 0"COILING DOOR4' - 0"2' - 0"HORIZONTAL PRE-FINISHED METAL WALL PANEL OVER METAL STUDS AT 16" O.C.PRE-FINISHED METAL WALL PANEL OVER METAL STUDS AT 16" O.C. -VERIFY DOOR WIDTH WITH DOOR SUPPLIEREXISTING OPENING10' - 0"COILING DOOR8' - 0"PAINT EXISTING CONCRETE BUILDING -TYPICALA4.15Sim13' - 0"COPYRIGHTC2022 Sowell Architects, IncA4.111-14-2222133EXTERIORELEVATIONSU STORAGE LITTLE ROCK1200 JOHN BARROWREMODEL1" = 10'-0"1FRONT ELEVATION -BUILDING 11" = 10'-0"4TYPCIAL ELEVATION -BUILDINGS 3-41" = 10'-0"2FRONT ELEVATIONS -BUILDING 21/2" = 1'-0"5TYPCIAL OVERHEAD DOOR INFILL1" = 10'-0"3REAR ELEVATION BUILDING 2REVISION SCHEDULENo. Description Date