HomeMy WebLinkAboutZ-4343-GG Staff AnalysisFILE NO.: Z -4343 -GG
NAME: The Ranch Long -form PCD and Right of Way Abandonment for Patrick
Country Road
LOCATION: Located at 18020 Cantrell Road
DEVELOPER:
Bank of the Ozarks
P.O. Box 8811
Little Rock, AR 72231
SURVEYOR:
White-Daters and Associates
24 Rahling Circle
Little Rock, AR 72223
AREA: 33.5 acres
WARD: 5
CURRENT ZONING:
ALLOWED USES
PROPOSED ZONING
NUMBER OF LOTS: 1
PLANNING DISTRICT: 20
FT. NEW STREET: 0 LF
CENSUS TRACT: 42.05
R-2, Single-family, 0-3, General Office and C-3,
General Commercial
Commercial, Office, Single-family, Church
PCD
PROPOSED USE: Bank of the Ozarks Headquarters — Office and Commercial -
O-3, General Office District uses and C-3, General Commercial District uses
VARIANCE/WAIVERS: A variance from the City's Land Alteration Ordinance to allow
grading of future phases with the grading of the first phase.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The applicant is requesting a rezoning of 33.5 -acres from R-2, Single-family, 0-3,
General Office and C-3, General Commercial to allow the development of this
site as the Bank of the Ozarks corporate headquarters and campus. The project
is proposed in multiple phases (7 -phases total). The first phase includes the
construction of a five (5) level office building and underground parking. The total
FILE NO.: Z -4343 -GG (Cont_
building spare footage for Phase 1 is 180,000 square feet of office space. The
plan includes 290 parking spaces within the parking deck and 275 surface
spaces for a total of 565 parking spaces.
Phase 2 is proposed with a bank containing 2,800 square feet. The building is a
one-story building. 34 parking spaces will be constructed with the bank. The
bank is to be located on the western side of the development near the existing
Patrick Country Road. Also in Phase 2 an office/retail building containing
60,000 square feet of floor area will be constructed. The building is proposed
with three (3) levels. Two (2) levels of office and one (1) level of retail. With this
construction 155 parking spaces will be provided.
Phase 3 includes the construction of an office building with four (4) levels of
office and one (1) level of underground parking. The office spaces totals
56,000 square feet with 36 parking spaces within the deck and 127 surface
parking spaces.
Phase 4 is proposed with a four (4) level office building and an area for
underground parking. The building is proposed containing 66,000 square feet of
office space. The plan includes 36 parking spaces within the deck and
142 surface parking spaces.
Phase 5 is proposed with a four (4) level office building and one (1) level of
underground parking. The office building is proposed with 74,000 square feet of
floor area. The plan indicates 46 parking spaces within the underground parking
deck and 126 surface spaces.
Phase 6 is proposed with a four (4) level office building and an area for
underground parking. The building is proposed containing 66,000 square feet of
office space. The plan includes 46 parking spaces within the deck and
138 surface parking spaces.
Phase 7 is proposed with 56,000 square feet of office space within a four
(4) story building. There are 137 surface parking spaces proposed with
this phase.
Also included in the request is the abandonment of Patrick Country Road
extending north from Cantrell Road to the "bridge". The area north of the bridge
was previously abandoned. The abandonment request is a 50 -foot wide right of
way extending from Cantrell Road north approximately 1,050 linear feet. The
right of way is located west of Tract E, The Ranch Subdivision, in the City of Little
Rock, Pulaski County, Arkansas. The area will be retained as a utility and
drainage easement.
E
FILE NO.: Z -4343 -GG (Cont.
B. EXISTING CONDITIONS:
The site is located within the Ranch Development, north of Cantrell
Road/Highway 10. The eastern portion of the development site is grass covered
with few trees. The western portion of the development site, across Patrick
Country Road, contains a church. The area north of the church is wooded.
There is a creek running along the northern boundary of the site. North of the
creek on the eastern portion of the development is a multi -family development
and north of the western portion of the development is a single-family
subdivision. Across Cantrell Road are single-family homes built on acreage.
East of the site there are two (2) single-family subdivisions accessed from
Cantrell Road, the Johnson Ranch Subdivision and the Chevaux Court
Subdivision. Other uses in the area include commercial and office businesses
located east of this site within the Ranch Development and on the southeast
corner of Chenonceau Boulevard and Cantrell Road.
Cantrell Road is a four (4) lane State Highway with a continuous center turn
lane. There are no sidewalks in place along the frontage of the proposed
development area.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received an informational phone call from an area
property owner. All property owners located within 200 -feet of the site along with
the Aberdeen Court POA, the Bayonne Place POA, the Chevaux POA, the
Duquesne Place POA, the Johnson Ranch Neighborhood Association and the
Maywood Manor Neighborhood Association were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Cantrell Road is classified on the Master Street Plan as a principal arterial.
Dedication of right-of-way to 55 feet from centerline will be required.
2. Sidewalks with appropriate handicap ramps are required adjacent to
Chenonceau Boulevard and Cantrell Road in accordance with Section
31-175 of the Little Rock Code and the Master Street Plan.
3. Damage to public and private property due to hauling operations or
operation of construction related equipment from a nearby construction site
shall be repaired by the responsible party prior to issuance of a certificate of
occupancy.
4 Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
3
FELE NO.: Z -4343 -GG Cant.
5. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other
than residential subdivisions, site grading and drainage plans must be
submitted and approved prior to the start of construction. Will an advance
grading permit be requested to clear and grade future phases with
construction of phase 1?
6. Provide a Sketch Grading and Drainage Plan per Section 29-186 (e).
7. Stormwater detention ordinance applies to this property. How will detention
be provided?
8. If disturbed area is one (1) or more acres, obtain a NPDES stormwater
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
9. A special Grading Permit for Flood Hazard Areas will be required per
Section 8-283 prior to construction.
10. Provide existing topographic information at maximum five-foot contour
interval. Show the limits of the 100 -year floodway and floodplain.
11.. The minimum Finish Floor elevation of at least one (1) foot above the base
flood elevation is required to be shown on plat and grading plans.
12. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25 foot
wide drainage and access easement is required adjacent to the floodway
boundary.
13. Alteration of the water course will require approval from the Little Rock
District of the US Army Corps of Engineers prior to start of work.
14. The proposed alteration of the floodway will require flood map revisions.
Obtain a conditional letter of map revision and no rise certification approval
from Public Works and the Federal Emergency Management Agency prior
to issuance of a grading permit and/or a building permit. An approved letter
of map revision must be obtained prior to issuance of a certificate of
occupancy.
15. Obtain permits for improvements within State Highway right-of-way from
AHTD, District VI.
16. The end of the proposed island in the driveway at the Cantrell Road
intersection should be located 22 feet from the back of curb on Cantrell
Road.
17. On plan show driveway locations on the south side of Cantrell Road in
relation to the proposed driveways on the north.
18. At the time the development is constructed and signal warrants are believed
to be met, submit a Traffic Study for the proposed signal. Study should
address trip generation, turn movements, and trip distribution for the
development and also should take into account existing and projected traffic
growth and future phases of development.
12
FILE NO.: Z -4343-G9 Cont
19. Hauling of fill material on or off site over municipal streets and roads
requires approval prior to a grading permit being issued, Contact Public
Works Traffic Engineering, 621 South Broadway, Travis Herbner,
the rbner@a I_ittlerock .orp or 501.379,1805 for more information.
20. Streetlights are required by Section 31-403 of the Little Rock code. Provide
pians for approval to Traffic Engineering. Streetlights must be installed prior
to platting/certificate of occupancy. Contact Traffic Engineering, Greg
Simmons, gsimmons iittlerock.or or 501.379,1813 for more information.
21. Provide a letter prepared by a registered engineer certifying the intersection
sight distance at the intersection(s) comply with 2004 AASHTO Green Book
standards.
22. A minimum undisturbed strip 25 feet wide except for reasonable access
shall be provided along each side of streams having a 10 -year storm X150
cfs. The undisturbed strip should be measured from the top of the bank.
23. Easements are required for stormwater drainage within the abandoned
right-of-way.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available to this site. Contact Little Rock Wastewater if
additional information is required.
Entergy: Entergy is aware of this project already and is currently working with
the developer regarding line locations and service requirements. Any ROW
abandonment and location of new easements will be coordinated with the
developer as the project progresses.
Center Dint Ener : No comment received.
AT & T: No comment received.
Central Arkansas Water: Central Arkansas Water approves the abandonment
of the right of way with a utility easement remaining in the described area.
Fire Department:
1. Maintain Access:
2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is located on a
fire apparatus access road, the minimum road width shall be 26 feet,
exclusive of shoulders.
I:
FILE NO.: Z-4343-GG(Cont.)
3. Grade. Maintain fire apparatus access roads as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire
apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
4. Loading. Maintain fire apparatus access road design as per Appendix D of
the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and
loading. Facilities, buildings or portions of buildings hereafter constructed
shall be accessible to fire department apparatus by way of an approved fire
apparatus access road with an asphalt, concrete or other approved driving
surface capable of supporting the imposed load of fire apparatus weighing at
least 75,000 pounds.
5. Commercial and Industrial Developments — 2 means of access. - Maintain
fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1.
a. Section D104.1 Buildings exceeding three stories or 30 feet in height.
Building or facilities exceeding 30 feet or three stories in height shall
have at least two means of fire apparatus access for each structure.
b. Section D104.2 Building exceeding 62,000 square feet in area.
Buildings or facilities having a gross building area of more than
62,000 square feet shall be provide with two separate and approved
fire apparatus access roads.
i. Exception: Projects having a gross building area of up to
124,000 square feet that have a single approved fire apparatus
access road when all building are equipped throughout with
approved automatic sprinkler systems.
c. D104.3 Remoteness. Where two fire apparatus access roads are
required, they shall be placed a distance apart equal to not less than
one half of the length of the maximum overall diagonal dimension of
the lot or area to be served, measured in a straight line between
accesses.
6. 30' Tall Buildings - Maintain aerial fire aggaratus access roads as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D105.1 — D105.4
a. D105.1 Where Required. Where the vertical distance between the
grade plane and the highest roof surface exceed 30', approved
aerial fire apparatus access roads shall be provided. For the
purposes of this section the highest roof surfaces shall be
determined by measurement to the eave of a pitched roof, the
[.1
FILE NO.: Z -4343 -GG (Co
intersection of a roof to the exterior wall, or the top of the parapet
walls, whichever is greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a
minimum unobstructed with of 26', exclusive of shoulders, in the
immediate vicinity of the building or portion thereof.
C. D105.3 Proximity to building. At least one of the required access
routes meeting this condition shall be located within a minimum of
15 feet and a maximum of 30 feet from the building, and shall be
Positioned parallel to one entire side of the building. The side of the
building on which the aerial fire apparatus access road is positioned
shall be approved by the fire code official.
d. D105.4 Obstructions. Overhead utility and power lines shall not be
located over the aerial fire apparatus access road or between the
aerial fire apparatus road and the building. Other obstructions shall
be permitted to be places with the approval of the fire code official.
7 Dead. Maintain fire apparatus access roads at dead end locations
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D103.4 Dead Ends. Dead-end fire apparatus access roads in
excess of 150 feet shall be provided with width and turnaround provisions
in accordance with Table D103.4. Requirements for Dead-end fire
apparatus access roads.
8. Gates. Maintain fire apparatus access road gates as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire
apparatus access road gates. Gates securing the fire apparatus access
roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation
by one person.
4. Gate components shall be maintained in an operable condition at all
times and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by
fire department personnel for emergency access. Emergency opening
devices shall be approved by the fire code ofFicieil.
6. Manual opening gates shall not be locked with a padlock or chain and
padlock unless they are capable of being opened by means of forcible
entry tools or when a key box containing the keys to the lock is
installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the
fire code official
7
FILE NO.: Z -4343 -GG (Cont.
8. Electric gate operators, where provided, shall be listed in accordance
with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed
and installed to comply with requirements of ASTM F 2200.
9. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the
2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction
with Central Arkansas Water (Jason Lowder 501.377.1245) and the
Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501.918.3757 or
Capt. John Hogue 501.918.3754). Number and Distribution of Fire Hydrants
as per Table C105.1.
Parks and Recreation: No comment received.
County Planning: No comment.
Rock Region Metro: Location is served by METRO on Express Route 25 at
Cantrell Road and Patrick Country Road. The area is an important location for
future transit plans. We request that the pedestrian walk along Cantrell Road be
located as close to the road as is allowed by code in order to reduce the grassy
area between the sidewalk the access to a transit stop. The grassy verge
becomes difficult to negotiate for ADA passengers in frequently muddy and wet
conditions. We would like to commend the designers for pedestrian paths to each
building for access to jobs by persons with disabilities and transit users.
F. ISSUES/TECHNICAL/DESIGN.
Building Code: Project is subject to full commercial plan review and approval
prior to issuance of a building permit. For information on submittal requirements
and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; cricheyplittlerock.org or
Mark Alderfer at 501.371.4875; ma Iderfer(r_Dlittlerock. orq.
Building will be limited by height requirements of building construction type as per
2012 Arkansas Fire Protection Code.
Planning Division: This request is located in the Pinnacle Planning District. The
Land Use Plan shows Public Institution (PI) and Commercial (C) for this property.
The Public/Institution category includes public and quasi -public facilities that
provide a variety of services to the community such as schools, libraries, fire
stations, churches, utility substations, and hospitals. The Commercial category
includes a broad range of retail and wholesale sales of products, personal and
professional services, and general business activities. Commercial activities vary
in type and scale, depending on the trade area that they serve. The applicant has
applied for a rezoning from R-2 (Single Family District) and C-3, General
0
FILE NO.: Z -4343 -GG (Cont.)
Commercial District to PCD (Planned Commercial District) to build seven (7) new
buildings for a banking -campus. The request is within the Highway 10 Design
Overlay District.
Master Street Plan: The south side of the property is Cantrell Road and it is a
Principal Arterial, within the development area is Patrick Country Road and it is a
Local street on the Master Street Plan. A Principal Arterial is to serve through
traffic and to connect major traffic generators or activity centers within the
urbanized area. Entrances and exits should be limited to minimize negative
effects of traffic and pedestrians on Cantrell Road. The primary function of a
Local Street is to provide access to adjacent properties. Local Streets that are
abutted by non-residential zoning/use or more intensive zoning than duplexes
are considered as "Commercial Streets". A Collector design standard is used for
Commercial Streets. These streets may require dedication of right-of-way and
may require street improvements for entrances and exits to the site.
Bicycle Plan: A Class I Bike Path is shown along Cantrell Road. A Bike Path
is to be a paved path physically separate for the use of bicycles. Additional
right-of-way or an easement is recommended. Nine -foot paths are
recommended to allow for pedestrian use as well (replacing the sidewalk).
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements and the Highway 10 Design Overlay District.
2. The Highway 10 frontage (front yard) shall consist of a minimum of
forty (40) feet of landscaped area exclusive of right-of-way. The landscaped
area shall contain organic and/or combined man-made/organic features
such as berms, brick walls and dense plantings such that vehicular use
areas are screened when viewed from an elevation of forty-two (42) inches
above the elevation of the adjacent street. Trees shall be planted or
be existing at least every twenty (20) feet and have a minimum of
two (2) inches in diameter when measured twelve (12) inches from the
ground at time of planting. Provide screening shrubs no less than thirty
(30) inches in height at installation with an average linear spacing of not
less at three (3) feet within the required landscape area
3. Screening requirements will need to be met for the vehicular use areas
adjacent to street right-of-ways. Provide screening shrubs with an average
linear spacing of not less at three (3) feet within the required landscape
area. Provide trees with an average linear spacing of not less than
thirty (30) feet.
4. A land use buffer six (6) percent of the average width / depth of the lot will
be required when an adjacent property has a dissimilar use of a more
restrictive nature. The property to the north is zoned MF -18. The maximum
dimension shall be fifty (50) feet. As a component of all land use buffer
requirements, opaque screening, whether a fence or other device, a
9
FILE NO.: Z -4343 -GG (Cont.
minimum of six (6) feet in height shall be required upon the property line
side of the buffer. A minimum of seventy (70) percent of the land use buffer
shall be undisturbed. Easements cannot count toward fulfilling this
requirement. The plantings, existing and purposed, shall be provided within
the landscape ordinance of the City, Section 15-81.
5. A perimeter planting strip is required along any side of a vehicular use area
that abuts adjoining property or the right-of-way of any street. This strip shall
be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines
shall be planted for every thirty (30) linear feet of perimeter planting strip.
6. Building landscape areas shall be provided at the rate equivalent to planter
strip three (3) feet wide along the vehicular use area. One (1) tree and four
(4) shrubs shall be planted in the building landscape areas for each
forty (40) linear feet of vehicular use area abutting the building.
7. Eight percent (8%) of the vehicular use area must be designated for green
space; this green space needs to be evenly distributed throughout
the parking area(s). For developments with more than one hundred fifty
(150) parking spaces the minimum size of an interior landscape area shall
be three hundred (300) square feet. Interior islands must be a minimum of
seven and one half (7 1/2) feet in width. Trees shall be included in the
interior landscape areas at the rate of one (1) tree for every twelve
(12) parking spaces.
8. A landscape irrigation system shall be required as per Highway 10 Site
Design and Development Standards.
9. The development of two (2) acres or more requires the landscape plan to be
stamped with the seal of a Registered Landscape Architect.
10. The City Beautiful Commission recommends preserving as many existing
trees as feasible on sites. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper
or larger.
G. SUBDIVISION COMMITTEE COMMENT; (February 3, 2016)
The applicants were present representing the request. Staff presented an
overview of the item stating there were a number of outstanding technical issues
associated with the request. Staff stated the site was located within the Highway
10 Design Overlay District which had specific development criteria related to
setbacks, landscaped areas and signage. Staff requested the applicant provide
the proposed development schedule for the new construction indicating the
approximate dates for completion of the various phases.
Public Works comments were addressed. Staff stated a grading permit was
required prior to any clearing or grading activities on the site. Staff stated the
City's Stormwater Detention Ordinance would apply to the development of the
site. Staff noted the request included the abandonment of Patrick Country Road.
Staff stated the area should be retained as a utility and drainage easement. Staff
10
FILE NO.: Z -4343 -GG (Cont.
stated streetlights were required to be installed prior to final platting or the
issuance of a certificate of occupancy. Staff requested the applicant provide the
existing topographic information at a maximum five (5) foot contour intervals.
Staff also requested the applicant provide the limits of the floodway and the
floodplain.
Landscaping comments were addressed. Staff stated the Highway 10 Design
Overlay District required the placement of a 40 -foot landscape strip along the
Cantrell Road/Highway 10 frontage. Staff stated in addition the Overlay required
the placement of a 25 -foot landscape strip along the sides and rear perimeters.
Staff stated building landscaping and parking lot landscaping would be required
at the time of development. Staff stated a screening mechanism such as a
fence, wall or dense evergreen plantings was required along the perimeters
which abutted residential uses. Staff noted the development of the site would
require an automatic irrigation system to water landscaped areas. Staff stated
with the submission of the building permit request a landscape plan, stamped
with the seal of a registered landscape architect would be required.
Staff noted the comments from the various other departments and agencies.
Staff suggested the applicant contact the departments or agencies directly with
any questions or concerns. There were no more issues for discussion. The
Committee then forwarded the item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to staff addressing most of the
technical issues associated with the request. The applicant has provided the
proposed development schedule for the new construction. The applicant has
also indicated screening will be provided along the northern perimeter where
adjacent to residentially zoned and/or used property either with plantings or with
a screening fence or wall. The site work will begin in the spring -summer of 2016
with building construction beginning in the fall 2016 extending into the spring
2017. The remaining buildings will come on line as market demands.
The request is to rezone 33.5 -acres from R-2, Single-family, 0-3, General Office
and C-3, General Commercial to Planned Commercial Development, PCD, to
allow the development of this site as the Bank of the Ozarks corporate
headquarters and campus. The project is proposed in multiple phases (7 -phases
total). The applicant has indicated there are no lots proposed, only phase lines
within the development area. The first phase includes the construction of a five
(5) level office building and underground parking. The total building space
footage for Phase 1 is 180,000 square feet of office space. The plan includes
290 parking spaces within the parking deck and 275 surface spaces for a total of
565 parking spaces.
11
FILE NO.: Z -4343 -GG
Phase 2 is proposed with a bank containing 2,800 square feet. The building is a
one-story building. 34 parking spaces will be constructed with the bank. The
bank is to be located on the western side of the development near the existing
Patrick Country Road. Also in Phase 2 an office/retail building containing
60,000 square feet of floor area will be constructed. The building is proposed
with three (3) levels. Two (2) levels of office and one (1) level of retail. With this
construction 155 parking spaces will be provided.
Phase 3 includes the construction of an office building with four (4) levels of
office and one (1) level of underground parking. The office spaces totals
56,000 square feet with 36 parking spaces within the deck and 127 surface
parking spaces.
Phase 4 is proposed with a four (4) level office building and an area for
underground parking. The building is proposed containing 66,000 square feet of
office space. The plan includes 36 parking spaces within the deck and
142 surface parking spaces.
Phase 5 is proposed with a four (4) level office building and one (1) level of
underground parking. The office building is proposed with 74,000 square feet of
floor area. The plan indicates 46 parking spaces within the underground parking
deck and 126 surface spaces.
Phase 6 is proposed with a four (4) level office building and an area for
underground parking. The building is proposed containing 66,000 square feet of
office space. The plan includes 46 parking spaces within the deck and
138 surface parking spaces.
Phase 7 is proposed with 66,000 square feet of office space within a
four (4) story building. There are 46 parking spaces within the underground
parking deck 138 surface parking spaces proposed with this phase.
The parking within each of the phase is more than adequate to meet the typical
parking demand for the site. The site plan indicates the placement of walks to
connect each of the buildings on the campus.
The plan indicates the placement of three (3) monument style signs one (1) with
a maximum height of ten (10) feet and a maximum sign area of 100 square feet
and two (2) with a maximum height of six (6) feet and a maximum sign area of
72 square feet along Cantrell Road. Two (2) sign locations are proposed on
Chenonceau Boulevard. The signs are proposed as a monument style sign with
a maximum height of six (6) feet and a maximum sign area of 72 square feet.
Building signage will be allowed as per Section 36-557, (all on -premises wall
signs must face required street frontage except in complexes where a sign
without street frontage would be the only means of identification for a tenant) and
as allowed per Section 36-555 or on the wall facades which have public street
frontage.
12
FILE NO.: Z -4343 -GG (Cont.
Also included in the request is the abandonment of Patrick Country Road
extending north from Cantrell Road to the "bridge". The area north of the bridge
was previously abandoned. The abandonment request is a 50 -foot wide right of
way extending from Cantrell Road north approximately 1,050 linear feet. The
right of way is located west of Tract E, The Ranch Subdivision, in the City of Little
Rock, Pulaski County, Arkansas. The area will be retained as a utility and
drainage easement. The applicant has secured approvals from the various
utility companies and from Public Works indicating there is not an issue with the
abandonment as long as the area is retained as a utility and drainage easement.
All setbacks are indicated more than adequate to meet the minimum standards of
the Highway 10 Design Overlay District. The buildings have more than the
minimum 100 -foot setback from the Cantrell Road frontage, more than the 40—
foot setback from the rear property line and well over the 30 -foot setback from
the side property lines. The plan indicates more than adequate landscape strips
for the front (40 -feet is required along the Cantrell Road frontage) and side and
rear yard buffer areas (side and rear is to average 25 -feet).
The Highway 10 Design Overlay District states berming is encouraged along the
Cantrell Road frontage. The applicant has indicated landscaping will be provided
along the Cantrell Road frontage with a combination of berming and plant
materials. Within the landscape area trees with a minimum of two (2) inch caliper
diameter will be planted at least every 20 -feet on center or as required per the
Overlay and the City's Landscape Ordinances.
The Overlay limits curb cuts to a maximum of one (1) curb cut per 300 linear feet
of street frontage and no curb cut is allowed closer to an intersection than
100 feet. The curb cuts as indicated comply with the typical ordinance
standards. The applicant has indicated on the site plan the placement of a traffic
signal. As noted in Public Works comments at the time the development is
constructed and the signal warrants are believed to be met, the applicant is to
submit a traffic study for the development and the proposed signal. The traffic
study should address trip generation, turn movements, and trip distribution for the
development and also should take into account existing and projected traffic
growth and future phases of development. The applicant will work with the City
and the Arkansas State Highway and Transportation Department for the timing of
the installation of the traffic signal.
The Overlay states parking lot lighting is to be designed and located in such a
manner so as not to disturb the scenic appearance preserved along the Highway
10 corridor. Lighting must be directed to the parking area and not reflected into
the adjacent neighborhoods. The applicant has indicated all site lighting will be
shoebox LED down lighting directed into the site to limit the over spilling of light.
The applicant has indicated the maximum pole height for the parking lot lighting
will be 25 -feet.
13
FILE NO.: Z -4343 -GG (Cont.
The applicant tis requesting approval of a variance from the City's Land
Alteration Ordinance to allow grading of future phases with the initial grading
request. The applicant has indicated site work will take place on the entire
development site with the first phase of grading to allow the cuts and fills to
balance on the site.
Staff is supportive of the applicant's request. Staff feels the request to rezone
the site from the various zoning district to a PCD to allow the development of the
future campus for the Bank of the Ozarks Headquarters is appropriate.
Staff does not feel the abandonment request for Patrick Country Road will have
any adverse impact since this development is incorporating the lands on each
side of the abandonment request and the northern portion of the right of way was
abandoned a number of years ago. To staff's knowledge there are no remaining
outstanding technical issues associated with the request.
STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda
staff report.
Staff recommends approval of the abandonment request for Patrick Country
Road provided the area be retained as a utility and drainage easement.
Staff recommends approval of the variance requests from the City's Land
Alteration Ordinance to allow grading of future phases with the
construction/grading of the first phase.
PLANNING COMMISSION ACTION: (FEBRUARY 25, 2016)
The applicant was present. There were no registered objectors present. Staff
presented the item with a recommendation of approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E and F of
the agenda staff report. Staff presented a recommendation of approval of the
abandonment request for Patrick Country Road provided the area be retained as a
utility and drainage easement. Staff presented a recommendation of approval of the
variance requests from the City's Land Alteration Ordinance to allow grading of future
phases with the construction/grading of the first phase. There was no further
discussion. The item was placed on the consent agenda and approved as
recommended by staff by a vote of 10 ayes, 0 noes and 1 absent.
14
ITEM NO.:
Z -4343 -GG
NAME: The Ranch Long -form PCD and Right of Way Abandonment for Patrick County
Road
LOCATION: located at 18020 Cantrell Road
Planning Staff Comments:
1. Provide notification of the property owners located within 200 -feet of the
development including the certified abstract list, notice form with affidavit executed
and proof of mailing. The notice must be mailed no later than February 10, 2016.
The Office of Planning and Development must receive the proof of notice no later
than February 19, 2016.
2. Provide the quantitative data including the parcel size, types and number of
permitted uses and floor areas according for each of the uses proposed.
3. Will the development be constructed on a single lot or are multiple lots proposed?
4. Provide the proposed pedestrian circulation system. Are the lines indicated on the
plan above ground walkways or underground tunnels?
5. Provide details of any proposed fencing, walls the purpose of these elements.
Provide the construction materials, total height and location.
6. Indicate any private and common open spaces including open space buffers.
7. Provide the location, dimensions, nature of all existing and proposed easements,
utility and streets, and public improvements, drainage, sewer, water.
8. Indicate the location of structures and structure dimensions, dimensioned distances
between buildings and distances from structure to property line.
9. Provide a development schedule indicating the approximately date when
construction of the planned unit development or stages of the planned unit
development can be expected to begin and be completed.
10. Provide a statement of the applicant's intentions with regard to the future selling or
leasing of all or portions of the planned unit development, including land areas.
11. Note on the site plan any permanent undisturbed buffers to be located on the site
and note the measures that will be taken to protect the undisturbed buffers.
12. The site is located in the Highway 10 Design Overlay District. The Overlay has
specific development criteria related to signage, building placement, landscaping
treatment.
a. Setbacks are to be a minimum of 100 -feet from the Cantrell Road
frontage, 40—feet from the rear property line and 30 -feet from the side
property lines.
b. A minimum landscape strip of 40 -feet is required along the Cantrell Road
frontage, a side and rear yard buffer averaging 25 -feet. Where the yards
abut a street right of way a 15 -foot buffer is required adjacent to land
zoned office and residentially. A seven (7) foot buffer is required adjacent
to lands zoned commercial.
c. Berming is encouraged along the Cantrell Road frontage. Provide the
proposed treatment of the front yard area. Within the landscape area
trees are to be planted or be existing at least every 20 -feet and have a
ITEM NO.: 2. Z -4343 -GG
minimum of two (2) inches in diameter when measured 12 -inches above
the ground when planted.
d. A single commercial development sign is allowed with a maximum height
of ten (10) feet and a maximum sign area of 100 square feet. — the plan
indicates three (3) sign locations.
e. Curb cuts are limited to a maximum of one (1) curb cut per 300 linear feet
of street frontage and no curb cut is allowed closer to an intersection than
100 feet.
f. Parking lot lighting is to be designed and located in such a manner so as
not to disturb the scenic appearance preserved along the Highway 10
corridor. Lighting must be directed to the parking area and not reflected
into the adjacent neighborhoods. Provide the maximum pole height for
the parking lot lighting.
Variance/Waivers: None requested.
Public Works Conditions:
1. Cantrell Road is classified on the Master Street Plan as a principal arterial.
Dedication of right-of-way to 55 feet from centerline will be required.
2. Sidewalks with appropriate handicap ramps are required adjacent to Chenonceau
Boulevard and Cantrell Road in accordance with Section 31-175 of the Little Rock
Code and the Master Street Plan.
3. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by
the responsible party prior to issuance of a certificate of occupancy.
4. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-
of-way prior to occupancy.
5. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction. Will an advance grading permit be requested to clear
and grade future phases with construction of phase 1?
6. Provide a Sketch Grading and Drainage Plan per Section 29-186 (e).
7. Stormwater detention ordinance applies to this property. How will detention be
provided?
8. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
9. A special Grading Permit for Flood Hazard Areas will be required per Section 8-283
prior to construction.
10. Provide existing topographic information at maximum five-foot contour interval.
Show the limits of the 100 -year floodway and floodplain.
11. The minimum Finish Floor elevation of at least one (1) foot above the base flood
elevation is required to be shown on plat and grading plans.
12. In accordance with Section 31-176, floodway areas must be shown as floodway
easements or be dedicated to the public. In addition, a 25 foot wide drainage and
access easement is required adjacent to the floodway boundary.
N
ITEM NO.- 2. Z-434
13.Alteration of the water course will require approval from the Little Rock District of the
US Army Corps of Engineers prior to start of work.
14. The proposed alteration of the floodway will require flood map revisions. Obtain a
conditional letter of map revision and no rise certification approval from Public Works
and the Federal Emergency Management Agency prior to issuance of a grading
permit and/or a building permit. An approved letter of map revision must be
obtained prior to issuance of a certificate of occupancy.
15. Obtain permits for improvements within State Highway right-of-way from AHTD,
District VI.
16. The end of the proposed island in the driveway at the Cantrell Road intersection
should be located 22 feet from the back of curb on Cantrell Road.
17. On plan show driveway locations on the south side of Cantrell Road in relation to the
proposed driveways on the north.
18.At the time the development is constructed and signal warrants are believed to be
met, submit a Traffic Study for the proposed signal. Study should address trip
generation, turn movements, and trip distribution for the development and also
should take into account existing and projected traffic growth and future phases of
development.
19. Hauling of fill material on or off site over municipal streets and roads requires
approval prior to a grading permit being issued. Contact Public Works Traffic
Engineering, 621 South Broadway, Travis Herbner, therbner(DIittlerock.org or
501.379.1805 for more information.
20. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans
for approval to Traffic Engineering. Streetlights must be installed prior to
platting/certificate of occupancy. Contact Traffic Engineering, Greg Simmons,
gsimmons@littlerock.org or 501.379.1813 for more information.
21. Provide a letter prepared by a registered engineer certifying the intersection sight
distance at the intersection(s) comply with 2004 AASHTO Green Book standards.
22.A minimum undisturbed strip 25 feet wide except for reasonable access shall be
provided along each side of streams having a 10 year storm >150 cfs. The
undisturbed strip should be measured from the top of the bank.
23. Easements are required for stormwater drainage within the abandoned right-of-way.
Utilities and Fire Department/County Planning:
Wastewater: Sewer available to this site. Contact Little Rock Wastewater if additional
information is required.
Entergy: Entergy is aware of this project already and is currently working with the
developer regarding line locations and service requirements. Any ROW abandonment
and location of new easements will be coordinated with the developer as the project
progresses.
Centerpoint Energy: No comment received.
AT & T: No comment received.
3
ITEM NO.: 2, Z -4343 -GG
Central Arkansas Water: Central Arkansas Water approves the abandonment of the
right of way with a utility easement remaining in the described area.
Fire Department:
1. Maintain Access:
2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as
3
4
5
per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1
Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus
access road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade. Maintain fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access
roads shall not exceed 10 percent in grade except as approved by the fire chief.
Loading. Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be accessible
to fire department apparatus by way of an approved fire apparatus access road with
an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments — 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1.
a. Section D104.1 Buildings exceeding three stories or 30 feet in height. Building
or facilities exceeding 30 feet or three stories in height shall have at least two
means of fire apparatus access for each structure.
b. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall
be provide with two separate and approved fire apparatus access roads.
i. Exception: Projects having a gross building area of up to 124,000
square feet that have a single approved fire apparatus access road
when all building are equipped throughout with approved automatic
sprinkler systems.
c. D104.3 Remoteness. Where two fire apparatus access roads are required,
they shall be placed a distance apart equal to not less than one half of the
length of the maximum overall diagonal dimension of the lot or area to be
served, measured in a straight line between accesses.
6. 30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1 — D105.4
a. D105.1 Where Required. Where the vertical distance between the grade
plane and the highest roof surface exceed 30', approved aerial fire
apparatus access roads shall be provided. For the purposes of this section
the highest roof surfaces shall be determined by measurement to the eave
Iv
ITEM NO.:
7
Z -4343 -GG
of a pitched roof, the intersection of a roof to the exterior wall, or the top of
the parapet walls, whichever is greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26', exclusive of shoulders, in the immediate vicinity
of the building or portion thereof.
c. D105.3 Proximity to building. At least one of the required access routes
meeting this condition shall be located within a minimum of 15 feet and a
maximum of 30 feet from the building, and shall be positioned parallel to
one entire side of the building. The side of the building on which the aerial
fire apparatus access road is positioned shall be approved by the fire code
official.
d. D105.4 Obstructions. Overhead utility and power lines shall not be located
over the aerial fire apparatus access road or between the aerial fire
apparatus road and the building. Other obstructions shall be permitted to
be places with the approval of the fire code official.
Dead Ends. Maintain fire apparatus access roads at dead end locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4
Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates.Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply with all
of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times
and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and
padlock unless they are capable of being opened by means of forcible entry
tools or when a key box containing the keys to the lock is installed at the gate
location.
7. Locking device specifications shall be submitted for approval \by the fire code
official
8. Electric gate operators, where provided, shall be listed in accordance with UL
325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
5
ITEM NO.: 2. Z -4343 -GG
9. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water
(Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony
Rhodes 501.918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution
of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comment received.
County Planning No comment.
Rock Region Metro: Location is served by METRO on Express route 25 at Cantrell
Road and Patrick Country Road. The area is an important location for future transit
plans. We request that the pedestrian walk along Cantrell Road be located as close to
the road as is allowed by code in order to reduce the grassy area between the sidewalk
the access to a transit stop. The grassy verge becomes difficult to negotiate for ADA
passengers in frequently muddy and wet conditions. We would like to commend the
designers for pedestrian paths to each building for access to jobs by persons with
disabilities and transit users.
Building Code: Project is subject to full commercial plan review and approval prior to
issuance of a building permit. For information on submittal requirements and the review
process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichey@littlerock.org or
Mark Alderfer at 501.371.4875; malderfer littlerock.or .
Building will be limited by height requirements of building construction type as per 2012
Arkansas Fire Protection Code.
Planning Division: This request is located in the Pinnacle Planning District. The Land
Use Plan shows Public Institution (PI) for this property and Commercial (C). The
Public/Institution category includes public and quasi -public facilities that provide a
variety of services to the community such as schools, libraries, fire stations, churches,
utility substations, and hospitals. The Commercial category includes a broad range of
retail and wholesale sales of products, personal and professional services, and general
business activities. Commercial activities vary in type and scale, depending on the trade
area that they serve. The applicant has applied for a rezoning from R-2 (Single Family
District) and C-3, General Commercial District to PCD (Planned Commercial District) to
build seven (7) new buildings for a banking -campus. The request is within the Highway
10 Design Overlay District.
Master Street Plan: The south side of the property is Cantrell Road and it is a Principal
Arterial, within the development area is Patrick Country Road and it is a Local street on
Gel
ITEM NO.: 2. Z -4343 -GG
the Master Street Plan. A Principal Arterial is to serve through traffic and to connect
major traffic generators or activity centers within the urbanized area. Entrances and
exits should be limited to minimize negative effects of traffic and pedestrians on Cantrell
Road. The primary function of a Local Street is to provide access to adjacent properties.
Local Streets that are abutted by non-residential zoning/use or more intensive zoning
than duplexes are considered as "Commercial Streets". A Collector design standard is
used for Commercial Streets. These streets may require dedication of right-of-way and
may require street improvements for entrances and exits to the site.
Bicycle Plan: A Class I Bike Path is shown along Cantrell Road. A Bike Path is to be a
paved path physically separate for the use of bicycles. Additional right-of-way or an
easement is recommended. Nine -foot paths are recommended to allow for pedestrian
use as well (replacing the sidewalk).
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance requirements
and the Highway 10 Scenic Corridor Design Overlay District.
2. The Highway 10 frontage (front yard) shall consist of a minimum of forty (40) feet of
landscaped area exclusive of right-of-way. The landscaped area shall contain
organic and/or combined man-made/organic features such as berms, brick walls and
dense plantings such that vehicular use areas are screened when viewed from an
elevation of forty-two (42) inches above the elevation of the adjacent street. Trees
shall be planted or be existing at least every twenty (20) feet and have a minimum of
two (2) inches in diameter when measured twelve (12) inches from the ground at
time of planting. Provide screening shrubs no less than thirty (30) inches in height at
installation with an average linear spacing of not less at three (3) feet within the
required landscape area
3. Screening requirements will need to be met for the vehicular use areas adjacent to
street right-of-ways. Provide screening shrubs with an average linear spacing of not
less at three (3) feet within the required landscape area. Provide trees with an
average linear spacing of not less than thirty (30) feet.
4. A land use buffer six (6) percent of the average width / depth of the lot will be
required when an adjacent property has a dissimilar use of a more restrictive nature.
The property to the north is zoned MF -18. The maximum dimension shall be fifty
(50) feet. As a component of all land use buffer requirements, opaque screening,
whether a fence or other device, a minimum of six (6) feet in height shall be required
upon the property line side of the buffer. A minimum of seventy (70) percent of the
land use buffer shall be undisturbed. Easements cannot count toward fulfilling this
requirement. The plantings, existing and purposed, shall be provided within the
landscape ordinance of the City, Section 15-81.
5. A perimeter planting strip is required along any side of a vehicular use area that
abuts adjoining property or the right-of-way of any street. This strip shall be at least
nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for
every thirty (30) linear feet of perimeter planting strip.
ITEM NO.: 2, Z -4343 -GG
6. Building landscape areas shall be provided at the rate equivalent to planter strip
three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs
shall be planted in the building landscape areas for each forty (40) linear feet of
vehicular use area abutting the building.
7. Eight percent (8%) of the vehicular use area must be designated for green space;
this green space needs to be evenly distributed throughout the parking area(s). For
developments with more than one hundred fifty (150) parking spaces the minimum
size of an interior landscape area shall be three hundred (300) square feet. Interior
islands must be a minimum of seven and one half (7 1/2) feet in width. Trees shall
be included in the interior landscape areas at the rate of one (1) tree for every twelve
(12) parking spaces.
8. A landscape irrigation system shall be required as per Highway 10 Site Design and
Development Standards,
9. The development of two (2) acres or more requires the landscape plan to be
stamped with the seal of a Registered Landscape Architect.
10.The City Beautiful Commission recommends preserving as many existing trees as
feasible on sites. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include