HomeMy WebLinkAboutZ-4328-B Staff AnalysisAugust 3, 2000
ITEM NO.: 9 FILE NO.: Z-4328-B
NAME: Lusk -Dearborn Office Warehouse - Conditional
Use Permit
LOCATION: 1200/1202 Rose Street
OWNER/APPLICANT: Ray Lusk & John Dearborn
PROPOSAL: To obtain a conditional use permit to build
a two -building office/warehouse complex in
two phases on property zoned C-3, General
Commercial located at 1200, 1202 Rose
Street.
ORDINANCE DESIGN STANDARDS:
1. SITE LOCATION:
This 2 acre site is located on the north side of Kanis
Road, between John Barrow Road and Michael Street.
2. COMPATIBILITY WITH NEIGHBORHOOD:
This site is zoned C-3, General Commercial. The property to
the east is MF-12, but is currently vacant and tree
covered. The properties to the south and west are zoned
C-3. There is currently a commercial facility to the south,
but the property to the west is vacant. To the north the
vacant, tree covered property is zoned 0-3, General Office.
Staff believes the proposed use would be compatible with
the neighborhood.
The Brownwood Terrace and John Barrow Neighborhood
Associations, all property owners within 200 feet, and all
residents within 300 feet that could be identified, were
notified of the public hearing.
3. ON SITE DRIVES AND PARKING:
The proposal includes extending a private drive off the
end of the existing Rose Street, which ends at the edge of
this property. There would be a parking area on the north
and south sides of the two-story building to be completed
in Phase 2. Phase 1 would consist of the southern -most
August 3, 2000
SUBDIVISION
ITEM NO.: 9 (Cont.)
FILE NO.: Z-4328-B
one-story building with a parking lot on the north side
of it.
The proposal includes 32 parking spaces in Phase 1 and 20
additional spaces in Phase 2. Using the breakdown provided
of approximately 80% warehouse and 20% office, the minimum
required parking would be 19 spaces total per floor, (8 for
office & 11 warehouse). That would result in a grand total
of 57 spaces required for the entire project versus 52
shown. There would be room to add spaces as parallel
parking spaces along the north side of the proposed north
parking area to meet the require minimum.
4. SCREENING AND BUFFERS:
A total of six percent of the on -site vehicular use area
must be landscaped with interior islands. Loading and
unloading areas are excluded from this requirement.
A three foot wide building landscape area between public
parking areas and the building are required. Some
flexibility with this requirement is allowed.
S. PUBLIC WORKS COMMENTS:
a. Right-of-way dedication required per the "MSP".
b. Easements shown for proposed storm drainage are required.
c. Easements for proposed stormwater detention facilities
are required.
d. Proposed design of streets conforming to "MSP" is
required.
e. Street profiles showing existing and proposed centerline
is required.
f. Driveways shall conform to Sec. 31-210 or Ordinance
18,031.
g. Stormwater Detention per Ordinance 14,787 and the
"Drainage Manual" is required.
h. Prepare a letter for streetlights as required by
Sec. 31-403.
i. Plans of all work in right-of-way shall be submitted for
approval prior to start of work.
j. New Cul-de-sac Street shall be public right-of-way or
petition to have complete length revert to private.
k.Existing topographic information at maximum five foot,
contour interval 100-year base flood elevation is
required.
K
August 3, 2000
SUBDIVISION
ITEM NO.: 9 (Cont.
FILE NO.: Z-4328-B
1. A Sketch Grading and Drainage plan per Sec. 29-186 (e) is
required.
m. A Grading Permit per Secs. 29-186 (c ) & (d) is required.
n. Parking areas need back out space for end spaces.
o.Name of Rose Street needs to be changed to avoid conflict
with other Rose Street.
6. UTILITY, FIRE DEPT. AND CATA COMMENTS:
Water: A water main extension will be required. Also,
on site fire protection or a private fire hydrant will be
required. An acreage charge of $150 per acre applies in
addition to normal charges.
Wastewater: Sewer main extension required with easements
to serve this property.
Southwestern Bell: No comments received.
ARKLA: No comments received.
Entergy: Approved as submitted.
Fire Department: Private fire hydrant may be required.
CATA: Site is near bus route #3 and the proposed
development should be designed to allow bus/transit access.
7. STAFF ANALYSIS:
The applicant has requested a conditional use permit to
build a two -building office/warehouse complex in two phases
on just under 2 acres of property zoned C-3, General
Commercial.
This site is nestled in a developing area of mixed
commercial and office zoning. Currently only the south side
of this site has developed. The applicant has proposed an
office/warehouse development with space for approximately
12 occupants in two buildings, allowing 4200 square feet
each, and operating generally between 7 a.m. and 6 p.m.
Monday through Friday. The use mix would be approximately
80% warehouse 20% office. The proposed layout does not meet
ordinance requirements with respect to the rear setback, 10
feet proposed versus 25 feet required. In addition about
half of the one-story building has only a 14 foot setback
3
August 3, 2000
SUBDIVISION
ITEM NO.: 9 (Cont.) FILE NO.: Z-4328-B
after right-of-way is dedicated for the hammerhead turn
around. However, Staff believes that would not cause an
adverse impact for future surrounding development, and
supports a variance for the reduced setbacks. The proposed
landscaping would be satisfactory.
Parking requirements for the mix of office and warehouse
would be 57 spaces. That number could be met by adding five
Parallel spaces on the north side of the north parking
area. Otherwise the driveway and parking would be
satisfactory. The proposed landscaping would be
satisfactory.
Staff believes the proposed use would be compatible with
the area.
8. STAFF RECOMMENDATION:
Staff recommends approval of the conditional use permit
subject to compliance with the following conditions:
a. Comply with the City's Landscape and Buffer Ordinances.
b. Comply with Public Works Comments.
c. Comply with Fire Department Comment.
d. Provide 57 parking spaces total.
e. All exterior lighting must be low intensity and directed
downward and inward to the property and not towards any
residential zoned area.
f. The applicant must petition to change the name of Rose
Street to a name not repeated elsewhere in the City.
Staff also recommends approval of a variance for the
reduced setback to the rear for both buildings and for the
front of the one-story building.
SUBDIVISION COMMITTEE COMMENTS: (JULY 13, 2000)
Ray Lusk, John Dearborn and Sam Davis were present representing
the application. Staff gave a brief description of the proposal.
Public Works comments and the Screening and Buffer comments were
the primary areas reviewed. The applicant was also asked to
provide additional information regarding the proposed exterior
features of the buildings including height and access doors, the
i
4
August 3, 2000
SUBDIVISION
ITEM NO.: 9 (Cont.)
FILE NO.: Z-4328-B
square footage mix of office and warehouse, and proposed hours
of operation. Changing the name of Rose Street was also
discussed.
There being no further issues, the Committee accepted the
Proposal and forwarded the item to the full Commission for final
action.
PLANNING COMMISSION ACTION:
(AUGUST 3, 2000)
Ray Lusk and John Dearborn were present representing the
application. There were no registered objectors present. Staff
Presented the item with a recommendation for approval subject to
compliance with the conditions .listed under "Staff
Recommendation," paragraph 8 above.
The item was placed on the Consent Agenda and approved as
submitted to include staff comments and recommendations. The
vote was 8 ayes, 0 nays and 3 absent.