Loading...
HomeMy WebLinkAboutZ-4029-C Map 30 0 a2 F3 2 I III 1 II I III , 3:: r 12" CIP --_• WATER _ PIPE \\\ \\\ -,`„ a he al Ok `\ \\ \ \ 30" RCP IN V=458.93' I I l II 'RIGHT TURN ONLY SIGN ROW ---------------------- - -------- - — — — — —— —EXISTING �= �SAWCUT MATCH EXISTING CONCRETE EXISTING CURB --------- -`i "- CURB _m �lDIRECTIONAL ISLAND AND MATCH NEW CONCRETE APRON EXISTING GUTTER — —�--- III --(2 E E N STREET o CROSSWALK EXISTING j• I III I III _ LA — ASPHALT 60' ROW) CURBH — POWER POLE III SDI QD CROSSWALK IS TING TELEPHONE PEDESTAL III III RIM 464.98' �Qv�` SIDEWALK O III -- SIDEWALK—__= ... ... ............ ....... ��'....�.. /--CONCRETE SIDEWALK SS SS III —i�----- ACCESSIBLE• --_ .. .. __ _ �__—'Z------ GAS VALVE /e� RAMP X7'5418 E 134.85— —_ �� '?1 ---—�__—__—_ �. tX ✓ /rMATCH W :r SIDEWALK SIDEWALK — — — — R 0 W — — _ W —Vy� —W�� EXISTING SIDEWALK — II III i II ACCESSIBLE— P 1 inwwocuri-• III 3 AND III I I /rel �' // DHE— W W WRAW — - ll. — OHEN_ vV -- j• I III I III III EXISTING GUTTER — _ 550'ROw III TI — . I — 5 � I I C4 .. — --OHE— W W POWER POLE III POWER POLE III III N _RCP � II / / V 459.34' I Or FF 10 FF w TELEPHONE PEDESTAL III III �0 JJ III III I II II III II I / PULL BOXTIL 8" CIP II 22.(' —I 25 BUILD NG MENT WATER O III INDEX CONTOUR III III III II I 3' FF PIPE II / SS SS III 6' HT. PRIVATE III / I ACCESSIBLE AMP _ I — 'STOP' SIGN GAS VALVE 'STOP' SIGN C---=-� STORM SEWER PIPE TYP.) ROW I W II III I II IACCESSIBLE SIGN DIRECTIONAL WATER LINE (SPECIFY SIZE & TYPE) III II i �' i ill ii'1 II III i II II I P LLY (TYP.) _— 18 24' 18' g' ARROW FIRE HYDRANT ASSEMBLY I III UNDERGROUND TELEPHONE III it II I BOX rn 6' HT. PRIVATE x I III 33 �I I II I� I ! WOOD FENCE P 1 inwwocuri-• III 3 AND I I I RAMP TOTAL PARKING SPACES j• FOUND IRON PIN III EXISTING GUTTER II LIGHT POLE POWER POLE CURB POWER POLE CURB I III TELEPHONE PEDESTAL — �0 JJ TV PEDESTAL INTERMEDIATE CONTOUR O I III II INDEX CONTOUR D SANITARY SEWER CLEANOUT SS SS 6' HT. PRIVATE III �DIRECA R�5 GAS VALVE 'STOP' SIGN C---=-� STORM SEWER PIPE WOOD FENCE ROW W — �'o.— DOWN GUY WATER LINE (SPECIFY SIZE & TYPE) D4 i �' i ill ii'1 UGT FIRE HYDRANT ASSEMBLY I UNDERGROUND TELEPHONE IBI I III I III NEW CONCRETE x AIR RELEASE VALVE 33 A FIRE DEPARTMENT CONNECTION SSMH I III APRON ■ OHE Yy 0 WATER METER OVERHEAD ELECTRIC ® a III 'BIGHT TURN UGTV m UNDERGROUND TELEVISION I III -- I I GRATED INLET OVERHEAD TELEVISION OH TV :ONLY SIGN CHAIN LINK FENCE LollL DROP INLET WOOD --J FENCE- X - TREE I II I I WOOD FENCE "' RIGHT OF WAY III III III I III NEW CONCRETE..:. TREE TO BE REMOVED ' 1 ROAD CENTERLINE SSMH I III DIRECTIONAL ISLAND RIM -462.25' I $'NI I III I DIRECTIONAL I CESS ARROW I EASEMENT I III � 1P n I LII III I 0`1— III I MATCH EXISTING I III SIDEWALK I ,. CROSSWALK III I I III 1 I O R 2 5 III III III SIDEWALK ACCEI SSIBLE III III III II I j RAMP I III '� I � II I II III I I X iii i ii I iii I y i i � sem: z MATCH EXISTING CURB 4W& GRAPHIC SCALE IN FEET 20' 0 20' SITE NOTES 1. THE DESIGN, INSPECTION, AND CERTIFICATION OF ANY RETAINING WALL SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT LIMITED TO, SEGMENTAL RETAINING WALLS, MASS GRAVITY WALLS, GABION WALLS, ETC., GREATER THAN FORTY-EIGHT INCHES IN HEIGHT, SHALL BE BY OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN SHALL BE FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS ONLY. 2. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA STANDARDS. 3. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. 4. ALL CURB DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 5. ALL PAVEMENT MARKINGS DIMENSIONS BACK OF CURB UNLESS OTHERWISE NOTED. 6. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 7. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE. 8. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. 9. CONTRACTOR SHALL MATCH NEW CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. 10. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM THE SITE. STANDARD PARKING SPACES 14 ACCESSIBLE PARKING SPACES 1 TOTAL PARKING SPACES 15 GENERAL NOTES 1. THE DESIGN, INSPECTION, AND CERTIFICATION OF ANY RETAINING WALL SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT LIMITED TO, SEGMENTAL RETAINING WALLS, MASS GRAVITY WALLS, GABION WALLS, ETC., GREATER THAN FORTY-EIGHT INCHES IN HEIGHT, SHALL BE BY OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN SHALL BE ONLY FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS. 2. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS IS BASED ON A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS, CRAFTON TULL ASSUMES NO RESPONSIBILITY REGARDING THE ACCURACY OF THE DEPICTED LOCATIONS) OF THE UNDERGROUND FACILITIES ON THESE DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ANY OTHER FACILITIES NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL VERIFY LOCATION OF ALL FACILITIES BEFORE BEGINNING WORK. 3. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS Or THE JOB SITE INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN OR NEAR THE CONSTRUCTION SITE. 4. THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL & ASSOCIATES, INC. AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL & ASSOCIATES, INC. 5. CONTRACTOR SHALL NOT CAUSE ANY LONG-TERM INCONVENIENCE TO THE PUBLIC, ADJACENT PROPERTY OWNERS, PEDESTRIANS, ETC. DURING CONSTRUCTION OF THIS PROJECT. CONTRACTOR SHALL PROVIDE ACCESS TO ALL ADJACENT PROPERTIES AT ALL TIMES DURING CONSTRUCTION. Ce LEGEND (EXISTING SYMBOLS) LINEWORK SYMBOLS LINEWORK o FOUND IRON PIN EASEMENT LIGHT POLE POWER POLE CURB POWER POLE CURB m TELEPHONE PEDESTAL — INTERMEDIATE CONTOUR TV PEDESTAL INTERMEDIATE CONTOUR O MANHOLE INDEX CONTOUR D SANITARY SEWER CLEANOUT SS SS ZS GAS METER SANITARY SEWER LINE D4 GAS VALVE LINE ---G---G— GAS C---=-� STORM SEWER PIPE STORM SEWER PIPE GAS LINE W DOWN GUY WATER LINE (SPECIFY SIZE & TYPE) D4 WATER VALVE UGT FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE UNDERGROUND TELEPHONE IBI UGE x AIR RELEASE VALVE UNDERGROUND ELECTRIC A FIRE DEPARTMENT CONNECTION ) ■ OHE Yy 0 WATER METER OVERHEAD ELECTRIC ® SPRINKLER HEAD UGTV m ELECTRIC PEDESTAL UNDERGROUND TELEVISION OHTV -- I I GRATED INLET OVERHEAD TELEVISION OH TV r--� CHAIN LINK FENCE LollL DROP INLET WOOD --J FENCE- X - TREE -X ---BARBED WIRE FENCE WOOD FENCE FIBER OPTIC RIGHT OF WAY TREE TO BE REMOVED — — ROAD CENTERLINE 00 LEGEND (CONSTRUCT) DCONCRETE SIDEWALK HEAVY DUTY ASPHALT CONCRETE PAVEMENT DREGULAR DUTY ASPHALT x x BARBED WIRE FENCE BUILDING SET BACK RIGHT OF WAY ROAD CENTERLINE 6. CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY IS IDENTIFIED IN THE PLANS OR SPECIFICATIONS. 7. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT WHICH ARE NECESSARY TO CONFORM TO OSHA, FEDERAL, STATE AND LOCAL REGULATIONS. B. CRAFTON TULL & ASSOCIATES, INC. (CTA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES FOR THE WORK INDICATED ON THESE DRAWINGS THEREFORE, CTA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT GRAFTON, TULL & ASSOCIATES INC. ASSUMES NO RESPONSIBILITY ON IBILITY F OR THE INTERPRETATION, COORDINATION, OR ADMINISTRATION OF THESE DOCUMENTS AND/OR DEVIATIONS THEREOF. FURTHERMORE, GRAFTON, TULL & ASSOCIATES, INC. WILL NOT BE RESPONSIBLE FOR ANY EFFECTS THAT ANY CHANGES TO THESE DOCUMENTS MAY HAVE ON ANY RELATED TRADES, CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT EXCEPT AS SPECIFICALLY NOTED IN THE AGREEMENT BETWEEN CRAFTON, TULL & ASSOCIATES AND THE OWNER. 9. ENERGIZED ELECTRICAL LINE SAFETY. WARNINGS, AND ADVANCED NOTICE$ ALL OWNERS, GENERAL CONTRACTORS, AND SUBCONTRACTORS ASSOCIATED WITH THIS PROJECT SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH, COMPLYING WITH, AND THE ENFORCEMENT OF ARKANSAS CODES AR ST § 11-5-307 AND § AR ST 11-5-308 AND ANY OTHER CURRENT STATE CODES PERTAINING TO ADVANCE NOTICE REQUIREMENTS AND FOR SAFETY OF ALL PERSONNEL, INCLUDING THE GENERAL PUBLIC, PERTAINING TO ANY WORK, MOVEMENT, AND ACTIVITY IN CLOSE PROXIMITY TO ANY ENERGIZED ELECTRICAL LINE. Arkansas One Call Know what's below. Call before you dig. 10825 Financial Centre Parkway, Suite 300 Little Rock, Arkansas 72211 Crafton Tull ® engineering I surveying 501.664.3245 t 501.664.6704 f www.craftontull.com CERTIFICATE OF AUTHORIZATION: � oF CRAFTON, TULL & =,_ ASSOCIATES, INC _ No. 109 =y O 'zJ Zs �PTAN3as EN6tNE6T- ORION FCU MIDTOWN LITTLE ROCK LITTLE ROCK, ARKANSAS Key Plan No. Description Date ;40 - This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. 't µUCTlOry PROJECT NO: GO�gORF ISSUE DATE: mm/dd/yy SOP THIS CONTACT: B.PETERSON DOCUMENT IS N CHECKED BY: s PRELIMINARY INANDIS PRELIMINARY ED N ATFINAL, S GNED T o PLANS AND SEALED DOCUMENT a� ©2019 Crafton, Tull &Associates, Inc. fid' p0 c; Nollonb>5� SITE PLAN APR 1 0 2019 IBY:.. ....... C 101 SYMBOLS LINEWORK • SET IRON PIN EASEMENT LIGHT POLE Y� POWER POLE CURB ■ TELEPHONE PEDESTAL 1206 IN TV PEDESTAL INTERMEDIATE CONTOUR QQ MANHOLE 1205 INDEX CONTOUR o SANITARY SEWER CLEANOUT A GAS METER SANITARY SEWER LINE H GAS VALVE O STORM SEWER PIPE GAS LINE STRUCTURE NUMBER WATER UNE 04 WATER VALVE FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE IBI AIR RELEASE VALVE 4 FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC • WATER METER ■ BACK FLOW PREVENTER OVERHEAD ELECTRIC • REDUCER FIBER OPTIC RECTANGULAR DROP INLET, GRATED INLET OR JUNCTION BOX (SPECIFY ON PLAN UNDERGROUND TELEVISION SHEET) OH TV OVERHEAD TELEVISION CIRCULAR DROP INLET, GRATED INLET OR JUNCTION CHAIN LINK FENCES 0 BOX (SPECIFY ON PLAN SHEET) WOOD FENCE DCONCRETE SIDEWALK HEAVY DUTY ASPHALT CONCRETE PAVEMENT DREGULAR DUTY ASPHALT x x BARBED WIRE FENCE BUILDING SET BACK RIGHT OF WAY ROAD CENTERLINE 6. CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY IS IDENTIFIED IN THE PLANS OR SPECIFICATIONS. 7. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT WHICH ARE NECESSARY TO CONFORM TO OSHA, FEDERAL, STATE AND LOCAL REGULATIONS. B. CRAFTON TULL & ASSOCIATES, INC. (CTA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES FOR THE WORK INDICATED ON THESE DRAWINGS THEREFORE, CTA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT GRAFTON, TULL & ASSOCIATES INC. ASSUMES NO RESPONSIBILITY ON IBILITY F OR THE INTERPRETATION, COORDINATION, OR ADMINISTRATION OF THESE DOCUMENTS AND/OR DEVIATIONS THEREOF. FURTHERMORE, GRAFTON, TULL & ASSOCIATES, INC. WILL NOT BE RESPONSIBLE FOR ANY EFFECTS THAT ANY CHANGES TO THESE DOCUMENTS MAY HAVE ON ANY RELATED TRADES, CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT EXCEPT AS SPECIFICALLY NOTED IN THE AGREEMENT BETWEEN CRAFTON, TULL & ASSOCIATES AND THE OWNER. 9. ENERGIZED ELECTRICAL LINE SAFETY. WARNINGS, AND ADVANCED NOTICE$ ALL OWNERS, GENERAL CONTRACTORS, AND SUBCONTRACTORS ASSOCIATED WITH THIS PROJECT SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH, COMPLYING WITH, AND THE ENFORCEMENT OF ARKANSAS CODES AR ST § 11-5-307 AND § AR ST 11-5-308 AND ANY OTHER CURRENT STATE CODES PERTAINING TO ADVANCE NOTICE REQUIREMENTS AND FOR SAFETY OF ALL PERSONNEL, INCLUDING THE GENERAL PUBLIC, PERTAINING TO ANY WORK, MOVEMENT, AND ACTIVITY IN CLOSE PROXIMITY TO ANY ENERGIZED ELECTRICAL LINE. Arkansas One Call Know what's below. Call before you dig. 10825 Financial Centre Parkway, Suite 300 Little Rock, Arkansas 72211 Crafton Tull ® engineering I surveying 501.664.3245 t 501.664.6704 f www.craftontull.com CERTIFICATE OF AUTHORIZATION: � oF CRAFTON, TULL & =,_ ASSOCIATES, INC _ No. 109 =y O 'zJ Zs �PTAN3as EN6tNE6T- ORION FCU MIDTOWN LITTLE ROCK LITTLE ROCK, ARKANSAS Key Plan No. Description Date ;40 - This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. 't µUCTlOry PROJECT NO: GO�gORF ISSUE DATE: mm/dd/yy SOP THIS CONTACT: B.PETERSON DOCUMENT IS N CHECKED BY: s PRELIMINARY INANDIS PRELIMINARY ED N ATFINAL, S GNED T o PLANS AND SEALED DOCUMENT a� ©2019 Crafton, Tull &Associates, Inc. fid' p0 c; Nollonb>5� SITE PLAN APR 1 0 2019 IBY:.. ....... C 101