HomeMy WebLinkAboutZ-4029-C Map 1�LLe
0—
e ='
I III � III III III I
III III III III I
III � III III I I I
III � a � III III III I
III I ! ; III III III I
III � � € III III I
IIII I
I IIII III 3G" RCP
INV=458.93'
'RIGHT TURN
ONLY SIGN
ROW
—.
F- ----------------- _
—rl---------------- —--------------
�I i i---------�- -SAWCUT EXISTING=====-___ _
MATCH EXISTING CONCRETE EXISTING CURB
CURB..
- DIRECTIONAL ISLAND AND MATCH NEW CONCRETE APRON
EXISTING GUTTER
EVER EEN STREET �I _ _
MATCH EXISTING
�- - o CROSSWALK CURB
12" CIP (2 LA ASPHALT 60' ROW) -
��
WATER SDMH CROSSWALK �Po� I TING
PIPE �� --+-i RIM -464.98'
- SIDEWALK
- - SIDEWALK _ -
_ �—CONCRETE SIDEWALK
ACCESSIBLE -----
vv RAMP
tI07'54187E :�j��FF �r----�----
---�
\ MATCH EXISTING — — SIDEWALK — — —5 R O W
W -i`— s — W W — ACCESSIBLE �—
SIDEWALK — OHE—W W — RAMP
I III III rtl 5505;ROW— 11 "RCP h C14I — H1 —OHEW w
—
II I III III II I / INV=459.34' 10' FF 10' FIE TIL
III III III ! II / 1PULL BOX MENT 8„ CIP
I III II II III 22.0 25 ILD NG
II t ' BUWATER
III I III III II / 3' FF PIPE
I III III III I 1 / ACCESSIBLE AMP _
I III II III I II 1 I 25' TYP.) — 'STOP' SIGN
III II SII
II IIIIIIIII IIIII IIIII III II PYACCES�S�IBLE SIGN
DIRECT
IONAL
24 9 ARROW
B LL (TYP.)
X rn 6' HT. PRIVATE
III IIII + N II I
�WOOD FENCE
II II I
III i' � II III � 3 :
I III I IIII ; ! II I I5'
I III I I II III 6 I I 25 — 45'6
I III I II III II I / ACCESSIBLE STRIPING
I III II III II' NEW, ISLAND
I III II III CONSTRUCT I I _ O
III I III MODULAR BLOCK UILDING -
III III III RETAINING WALL II II I ih 6' 6ACCESSIBLE
IIII III PARKING (TYP.)
I III 3
I III III III O ; II
I II IIII II 9 I
I III �I III Lib II I I
--ROWI III I III III II 25.0' :.}..
I III I III � I II I --- � o .. ..f::;:�� NEW CURB AND
GUTTER
I III IIII I I LLi w II I 5 ....::... ..::.:..::{.: :'•'.::::1::.:::::
III IIII III> II :•...� .. }:..o:::.::..::'f::':;::'' •
I
I III �I III Q Hi II ° E7: o24" RCP
I III I I III II ` :io: ••.:..:..:.:... .::.':.:
I III I I III }-' J t II I i,: ;:.- { .•..-...• •..•. � ' •: • �:. � IN V-458.49
III I I III f— Q
I III I I III —. a II � w ...�:..':: �'.'::':.';:':'.'::.-.'::._•.':.•'.'::• �'::.-'.'::.••�,'..:...':
I III I I III V3IV) II N.. •.................
CONSTRUCT
I III I I I III wI .:. .:. _ .;.:..........:.... • MODULAR BLOCK
III I I III > 0 IIII LLA • RETAINING WALL
I III I I III — _5 PULL II I IR1o'
II I I IIIz o BOXUJ
I III II I III I ~
III I III �Z I
II III EXISTING III I24 v
I III MATCH EXISTING POWER POLE IIII I 5 .1�
I III SIDEWALK TO REMAIN IIIw I �a
SSMH
I III ' "' IIIo1 RIM-46,3.18'III � MATCH EXISTING III I I � � e�
CURB - o
III Iy 111 19, (M
III SAWCUT EXISTING II I
c""�
EXISTING CURB SIDEWALK �
III AND MATCH I I}� �I ACCESSIBLE •
I III EXISTING GUTTER II RAMP e
6' HT. PRIVATE
III I DIRECARROW R 'STOP' SIGN WOOD FENCE
15
III ,I III
I III � IIII ,II , �' I
I III NEW CONCRETE 33SSMH
I III
APRON
III RIGHT TURN III IIIcF
I
o :R
I III
ONLY SIGN III III �2 0'
I III � i it ii II •: �`�'.•:: e�..:e•'' : � ,.
I III NEW CONCRETE GF .' 1 I SSMH
I III DIRECTIONAL ISLAND I FP.:.•::.'.:: I N RIM=462.25'
I III I i .I I '�� I �"' ,` o:.'••: _ , � o
I III I DIRECTIONAL C
r ESS
III ARROW I • EASEMENT
I
III MATCH EXISTING — —
I III SIDEWALK I " CROSSWALK
III I o I
/� III II III I R25
I II III SIDEWALK
III III III I ACCESSIBLE
I III I III III III I I RAMP s�
I III IIII III III I I I A
I III IIII III
ly III /I I I s
III z l I� III -
MATCH EXISTING
CURB
GRAPHIC SCALE IN FEET
20' 0 20'
ce SITE NOTES
1. THE DESIGN, INSPECTION, AND CERTIFICATION OF ANY RETAINING WALL
SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT LIMITED TO,
SEGMENTAL RETAINING WALLS, MASS GRAVITY WALLS, GABION WALLS,
ETC., GREATER THAN FORTY-EIGHT INCHES IN HEIGHT, SHALL BE BY
OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN
SHALL BE FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS
ONLY.
2. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL
CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA
STANDARDS.
3. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT
LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING,
SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING
DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS.
4. ALL CURB DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS
OTHERWISE NOTED.
5. ALL PAVEMENT MARKINGS DIMENSIONS BACK OF CURB UNLESS
OTHERWISE NOTED.
6. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT
SPECIFICATIONS.
7. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO
ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE
RESTRICTIVE.
8. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED
PF',IOR TO CONSTRUCTION START.
9. CONTRACTOR SHALL MATCH NEW CURB AND GUTTER, CONCRETE, AND
PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT.
1C. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS,
DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY
AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND
VEHICULAR TRAFFIC TO AND FROM THE SITE.
STANDARD PARKING SPACES 114
ACCESSIBLE PARKING SPACES 1
TOTAL PARKING SPACES
15
Ce GENERAL NOTES
1. THE DESIGN, INSPECTION, AND CERTIFICATION OF ANY RETAINING WALL
SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT LIMITED TO,
SEGMENTAL RETAINING WALLS, MASS GRAVITY WALLS, GABION WALLS,
ETC., GREATER THAN FORTY-EIGHT INCHES IN HEIGHT, SHALL BE BY
OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN
SHALL BE ONLY FOR COORDINATION OF THE WALL LOCATION AND
ELEVATIONS,
2. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR
STRUCTURES SHOWN ON THESE DRAWINGS IS BASED ON A SEARCH OF
THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE
NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS.
CRAFTON TULL ASSUMES NO RESPONSIBILITY REGARDING THE ACCURACY
OF THE DEPICTED LOCATION(S) OF THE UNDERGROUND FACILITIES ON
THESE DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND
PROTECTION OF ANY OTHER FACILITIES NOT SHOWN ON THESE
DRAWINGS. CONTRACTOR SHALL VERIFY LOCATION OF ALL FACILITIES
BEFORE BEGINNING WORK.
;k IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR
CONDITIONS OF THE JOB SITE INCLUDING SAFETY OF ALL PERSONS AND
PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING
HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO
INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY
MEASURES IN OR NEAR THE CONSTRUCTION SITE.
4. THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN,
AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF
GRAFTON, TULL & ASSOCIATES, INC. AND IS NOT TO BE USED, IN WHOLE
OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN
AUTHORIZATION OF GRAFTON, TULL & ASSOCIATES, INC.
5. CONTRACTOR SHALL NOT CAUSE ANY LONG-TERM INCONVENIENCE TO
THE PUBLIC, ADJACENT PROPERTY OWNERS, PEDESTRIANS, ETC. DURING
CONSTRUCRON OF THIS PROJECT. CONTRACTOR SHALL PROVIDE ACCESS
TO ALL ADJACENT PROPERTIES M ALL TIMES DURING CONSTRUCTION.
01 LEGEND (EXISTING SYMBOLS)
SYMBOLS LINEWORK
0
FOUND IRON PIN
EASEMENT
LIGHT POLE
lq
PF
LIGHT POLE
= —
0
TV PEDESTAL
)Sk
POWER POLE
CURB
SANITARY SEWER CLEANOUT
A
m
TELEPHONE PEDESTAL
GAS VALVE
O
STORM SEWER PIPE
TV PEDESTAL
INTERMEDIATE CONTOUR
WATER VALVE
♦N-
O
MANHOLE
INDEX CONTOUR
14
FIRE DEPARTMENT CONNECTION
D
SANITARY SEWER CLEANOUT
IN
BACK FLOW PREVENTER
SS
SS
GAS METER
SANITARY SEWER LINE
GRATED INLET OR JUNCTION
D4
GAS VALVE
G
GAS LINE
G
STORM SEWER PIPE
BOX (SPECIFY ON PLAN
W
C
DOWN GUY
WATER LINE (SPECIFY SIZE & TYPE)
D4
WATER VALVE
UGT
�J
FIRE HYDRANT ASSEMBLY
UNDERGROUND TELEPHONE
l
AIR RELEASE VALVE
UGE
UNDERGROUND ELECTRIC
Z.
FIRE DEPARTMENT CONNECTION
OH E
"Y
O
WATER METER
OVERHEAD ELECTRIC
®
SPRINKLER HEAD
UGTV
m
ELECTRIC PEDESTAL
UNDERGROUND TELEVISION
OHTV
OVERHEAD TELEVISION
GRATED INLET
L
--J
rr=,�
CHAIN LINK FENCE
DROP INLET
„?
LL•�'I
WOOD FENCE
x -
BARBED WIRE FENCE
TREE
FIBER OPTIC
RIGHT OF WAY
TREE TO BE REMOVED
—
—
ROAD CENTERLINE
LEGEND (CONSTRUCT)
SYMBOLS LINEWORK
•
SET IRON PIN
�}E
LIGHT POLE
lq
POWER POLE
■
TELEPHONE PEDESTAL
0
TV PEDESTAL
Q
MANHOLE
o
SANITARY SEWER CLEANOUT
A
GAS METER
►t
GAS VALVE
O
STORM SEWER PIPE
STRUCTURE NUMBER
04
WATER VALVE
♦N-
FIRE HYDRANT ASSEMBLY
IN
AIR RELEASE VALVE
14
FIRE DEPARTMENT CONNECTION
•
WATER METER
IN
BACK FLOW PREVENTER
•
REDUCER
RECTANGULAR DROP INLET,
FRI
GRATED INLET OR JUNCTION
BOX (SPECIFY ON PLAN
SHEET)
CIRCULAR DROP INLET,
GRATED INLET OR JUNCTION
BOX (SPECIFY ON PLAN
SHEET)
DCONCRETE SIDEWALK
HEAVY DUTY ASPHALT
'•�� CONCRETE PAVEMENT
DREGULAR DUTY ASPHALT
EASEMENT —
CURB
1206
INTERMEDIATE CONTOUR
INDEX CONTOUR
SANITARY SEWER LINE
GAS LINE
WATER LINE
UNDERGROUND TELEPHONE
UNDERGROUND ELECTRIC
OVERHEAD ELECTRIC
FIBER OPTIC
UNDERGROUND TELEVISION
OVERHEAD TELEVISION OHTV
CHAIN LINK FENCE
,20111 a , o
BARBED WIRE FENCE X
BUILDING SET BACK
RIGHT OF WAY
PROPERTY LINE
ROAD CENTERLINE
6. CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF A
DISCREPANCY OR INCOINSISTENCY IS IDENTIFIED IN THE PLANS OR
SPECIFICATIONS.
7. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF
ALL SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES
REQUIRED ON THE PROJECT WHICH ARE NECESSARY TO CONFORM TO
OSHA, FEDERAL, STATE AND LOCAL REGULATIONS,
B. CRAFTON TULL & ASSOCIATES, INC. (CTA) HAS NOT BEEN RETAINED BY
THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION
SERVICES FOR THE WORK INDICATED ON THESE DRAWINGS. THEREFORE,
CTA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT CRAFTON, TULL &
ASSOCIATES, INC. ASSUMES NO RESPONSIBILITY FOR THE
INTERPRETATION, COORDINATION, OR ADMINISTRATION OF THESE
DOCUMENTS AND/OR DEVIATIONS THEREOF. FURTHERMORE, CRAFTON,
TULL &ASSOCIATE INC. WILL NOT BE RESPONSIBLE NSIBLE FOR ANY EFFECTS
THAT ANY CHANGES TO THESE DOCUMENTS MAY HAVE ON ANY RELATED
TRADES, CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED
PROJECT EXCEPT AS SPECIFICALLY NOTED IN THE AGREEMENT BETWEEN
CRAFTON, TULL & ASSOCIATES AND THE OWNER.
9. ENERGIZE) ELECTRICAL LINE SAFETY, WARNINGS, AND ADVANCED
NOTE ALL OWNERS, GENERAL CONTRACTORS, AND SUBCONTRACTORS
ASSOCIATED WITH THIS PROJECT SHALL BE RESPONSIBLE FOR
FAMILIARIZING THEMSELVES WITH, COMPLYING WITH, AND THE
ENFORCEMENT OF ARKANSAS CODES AR ST § 11-5-307 AND § AR ST
11-5-308 AND ANY OTHER CURRENT STATE CODES PERTAINING TO
ADVANCE NOTICE REQUIREMENTS AND FOR SAFETY OF ALL PERSONNEL,
INCLUDING THE GENERAL PUBLIC, PERTAINING TO ANY WORK, MOVEMENT,
AND ACTIVITY IN CLOSE PROXIMITY TO ANY ENERGIZED ELECTRICAL
LINE.
Arkansas One Call
Know what's below.
Call before you dig.
10825 Financial Centre Parkway, Suite 300
Little Rock, Arkansas 72211
VGrafton Tull
engineering I surveying
501.664.3245 t 501.664.6704 f
www.craftontull.com
CERT I FI CATE OF AUTHORIZATION:
OF A( ry01
CRAFTON, TULL a
-,_ ASSOCIATES, INC D.
No. 109
�TTAA�AS ENGI�F��
lu
ORION FCU
MIDTOWN LITTLE ROCK
LITTLE ROCK, ARKANSAS
Key Plan
No. Description Date
VV
This document, and the ideas and designs incorporated herein,
as an instrument of professional service, is the property of
Crafton, Tull & Associates, Inc., and is not to be used, in whole
or in part, for any other project, without the written
authorization of Crafton, Tull & Associates, Inc.
SSI V,UCTION °
PROJECT NO:°RFL
155UF DATE: mm/dd/yy 4c, THIS
CONTACT: BYETERSONo DOCUMENT IS
CHECKED BY: z PRELIMINARY IN
NATURE AND IS NOT
PRELIMINARY N A FINAL, SIGNED o
PLANS z, AND SEALED
DOCUMENT RP'
2019 C,afton, Tull &Associates, Inc. fid' p0
`° rvoJionx�is�
n:
SITE PLAN APR 1. 0 2019
-By! ........
C-101-�t�a�'c'