HomeMy WebLinkAboutResponse to Comments 081522City of Little Rock Planning and Development
Planning Commission Hearing/September 8, 2022
Applicant Comments for Proposed Development
Applicant Responses are due no later than Wednesday. August 10, 2022. Please submit
revised site plans, if applicable, along with any written responses. All documents should be
submitted to this email address for review.
RE: Powell Short -Term Rental — PD-C (Z-9717)
3 Dove Circle
Development_ Comments:
1. Provide the maximum rental time (number of days).
2. Will any meals be provided to guests? 410
3. All signage must comply with Secti n 36-551 of the City's Zoning Ordinance (signs allowed
in single-family zones). 4J4 T
4. Any new sight lighting must be low-level and directed away from adjacent properties.40-
5. Will standard City of Little Rock garbage collection be utilized? �S
5.4 Obstructions. Overhead utility and power lines shall a located over the aerial fire
apparatus access between the aerial fire apparatus r nd the building. Other obstructions
shall be permitted to be places a praval of ire code official.
Fire Hvdrants
Locate Fire Hydrants as ppendix C of the 2012 Arkansas Fire Preven e. Section C101—
C105, in conjunc ' ith Central Arkansas Water (Daniel Tull 501-377-1245) and the Rock Fire
Marshals a (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3
Nu r and Distribution of Fire Hydrants as per Table C105.1.
Z-9717 Powell Short -Term Rental — PD-C 3 Dove Circle
Maintain Access: l C
06 fYI�J p
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in
grade except as approved by the fire chief. If the grade exceeds 10 percent,
approval will be denied and the applicant must submit request to be reviewed
by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30
feet or three stories in height shall have at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross
building area of more than 62,000 square feet shall be provide with two separate and approved fire
apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a
distance apart equal to not less than one half of the length of the maximum overall diagonal dimension
of the lot or area to be served, measured in a straight line between accesses.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C105.1.